Comparison of calibration methods for atomic-force microscopy cantilevers
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The scientific community needs a rapid and reliable way of accurately determining the stiffness of atomic-force microscopy cantilevers. We have compared the experimentally determined values of stiffness for ten cantilever probes using four different methods. For rectangular silicon cantilever beams of well defined geometry, the approaches all yield values within 17% of the manufacturer’s nominal stiffness. One of the methods is new, based on the acquisition and analysis of thermal distribution functions of the oscillator’s amplitude fluctuations. We evaluate this method in comparison to the three others and recommend it for its ease of use and broad applicability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Similarly, the force F was determined by recording the AFM cantilever deflection during sample deformation and knowing the spring constant of the AFM cantilever, calibrated using the thermal noise method [25]. The error in force measurements using this calibration method has been shown to be lower than 5% [26].”
From Extreme strength observed in limpet teeth (2015) · cites this paper as [26]
Citations
Cites
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Biological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Research works printed but not linked: 1
- Hazel J L, 1996, Polym. Preparation, 37, 567
Cited by
Items 101–200 of 522
Hussain, S., Xu, K., Ye, S., Lei, L., Liu, X., Xu, R., Xie, L., & Cheng, Z. (2019) · Frontiers of Physics · doi:10.1007/s11467-018-0879-7 · Cited by 56
Calibration of AFM cantilever stiffness: a microfabricated array of reflective springs
Cumpson, P. J., Zhdan, P. A., & Hedley, J. (2004) · Ultramicroscopy · doi:10.1016/j.ultramic.2003.10.005 · Cited by 56
Liu, Y., Pinzón‐Arango, P. A., Gallardo-Moreno, A. M., & Camesano, T. A. (2010) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.200900535 · Cited by 55
Calibration of higher eigenmodes of cantilevers
Labuda, A., Kocuń, M., Lysy, M., Walsh, T., Meinhold, J., Proksch, T., Meinhold, W., Anderson, C., & Proksch, R. B. (2016) · Review of Scientific Instruments · doi:10.1063/1.4955122 · Cited by 55
Free Energy of Membrane Protein Unfolding Derived from Single-Molecule Force Measurements
Preiner, J., Janovjak, H., Rankl, C., Knaus, H., Cisneros, D. A., Kedrov, A., Kienberger, F., Müller, D. J., & Hinterdorfer, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.096982 · Cited by 55
Accurate and precise calibration of AFM cantilever spring constants using laser Doppler vibrometry
Gates, R. S., & Pratt, J. R. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/37/375702 · Cited by 54
Kim, M., Choi, J.-H., Kim, J., & Park, Y.-K. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/11/014 · Cited by 54
Abbou, J., Anne, A., & Demaille, C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0493502 · Cited by 53
Thio, B. J. R., Lee, J., & Meredith, J. C. (2009) · Environmental Science & Technology · doi:10.1021/es803422s · Cited by 53
Basic Principles of Atomic Force Microscopy
Johnson, D. J., Hilal, N., & Bowen, W. R. (2009) · Elsevier eBooks · doi:10.1016/b978-1-85617-517-3.00001-8 · Cited by 58
Effect of water absorption on pollen adhesion
Lin, H., Lizárraga, L., Bottomley, L. A., & Meredith, J. C. (2014) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2014.11.065 · Cited by 52
Swelling and Softening of the Cowpea Chlorotic Mottle Virus in Response to pH Shifts
Wilts, B. D., Schaap, I. A. T., & Schmidt, C. F. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.04.019 · Cited by 51
Thrombin-induced contraction in alveolar epithelial cells probed by traction microscopy
Gavara, N., Sunyer, R., Roca‐Cusachs, P., Farré, R., Rotger, M., & Navajas, D. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00185.2006 · Cited by 51
The role of few-asperity contacts in adhesion
Thoreson, E. J., Martin, J., & Burnham, N. A. (2006) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.11.054 · Cited by 49
Self-citationComparison of the indentation and elasticity of E. coli and its spheroplasts by AFM
Sullivan, C. J., Venkataraman, S., Retterer, S. T., Allison, D. P., & Doktycz, M. J. (2007) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.04.017 · Cited by 49
Sub-picowatt resolution calorimetry with a bi-material microcantilever sensor
Canetta, C., & Narayanaswamy, A. (2013) · Applied Physics Letters · doi:10.1063/1.4795625 · Cited by 48
Ahmad, B., Shireen, F., Rauf, A., Shariati, M. A., Bashir, S., Patel, S. V., Khan, A., Ребезов, М. Б., Khan, M. U., Mubarak, M. S., et al. (2021) · IET Nanobiotechnology · doi:10.1049/nbt2.12007 · Cited by 48
Quantifying growth mechanics of living, growing plant cells in situ using microrobotics
Felekis, D., Muntwyler, S., Vogler, H., Beyeler, F., Grossniklaus, U., & Nelson, B. J. (2011) · Micro & Nano Letters · doi:10.1049/mnl.2011.0024 · Cited by 47
Electrostatic forces acting on tip and cantilever in atomic force microscopy
Bonaccurso, E., Schönfeld, F., & Butt, H. (2006) · Physical Review B · doi:10.1103/physrevb.74.085413 · Cited by 46
Mahmoud, M. A. E. (2016) · Critical reviews in solid state and materials sciences/CRC critical reviews in solid state and materials sciences · doi:10.1080/10408436.2016.1142858 · Cited by 45
Injection moulding of high aspect ratio micron-scale thickness polymeric microcantilevers
McFarland, A. W., Poggi, M. A., Bottomley, L. A., & Colton, J. S. (2004) · Nanotechnology · doi:10.1088/0957-4484/15/11/044 · Cited by 45
Cumpson, P. J., Hedley, J., & Clifford, C. A. (2005) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.2044809 · Cited by 45
Li, M., van der Mei, H. C., Ren, Y., Norde, W., & Busscher, H. J. (2009) · Langmuir · doi:10.1021/la9000494 · Cited by 44
Single-Molecule Protein Unfolding and Refolding Using Atomic Force Microscopy
Bornschlögl, T., & Rief, M. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-282-3_13 · Cited by 43
Allosteric Cross Talk between Cadherin Extracellular Domains
Shi, Q., Maruthamuthu, V., Li, F., & Leckband, D. E. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.03.062 · Cited by 43
Tracking unfolding and refolding reactions of single proteins using atomic force microscopy methods
Bujalowski, P. J., & Oberhauser, A. F. (2013) · Methods · doi:10.1016/j.ymeth.2013.03.010 · Cited by 42
High-speed adaptive contact-mode atomic force microscopy imaging with near-minimum-force
Ren, J., & Zou, Q. (2014) · Review of Scientific Instruments · doi:10.1063/1.4884343 · Cited by 42
Production and characterization of polymer microcantilevers
McFarland, A. W., Poggi, M. A., Bottomley, L. A., & Colton, J. S. (2004) · Review of Scientific Instruments · doi:10.1063/1.1777387 · Cited by 42
Kopycinska‐Müller, M., Caron, A., Hirsekorn, S., Rabe, U., Natter, H., Hempelmann, R., Birringer, R., & Arnold, W. (2008) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.2008.222.2-3.471 · Cited by 41
What can we learn from atomic force microscopy adhesion measurements with single drug particles?
Roberts, C. J. (2004) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2004.11.002 · Cited by 41
Self-citationPoisson Analysis of Streptococcal Bond-strengthening on Saliva-coated Enamel
Mei, L., Ren, Y., Busscher, H. J., Chen, Y., & van der Mei, H. C. (2009) · Journal of Dental Research · doi:10.1177/0022034509342523 · Cited by 39
Perkins, M. C., Bunker, M., James, J., Rigby-Singleton, S. M., Ledru, J., Madden, C. E., Luk, S. Y., Patel, N., & Roberts, C. J. (2009) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2009.05.004 · Cited by 38
Self-citationChandrappa, K. G., Venkatesha, T. V., Nayana, K. O., & Punithkumar, M. K. (2011) · Materials and Corrosion · doi:10.1002/maco.201005966 · Cited by 37
Self-assembly and elasticity of hierarchical proteoglycan–hyaluronan brushes
Attili, S., & Richter, R. P. (2013) · Soft Matter · doi:10.1039/c3sm51213d · Cited by 38
Enhanced sensitivity of mass detection using the first torsional mode of microcantilevers
Xie, H., Vitard, J., Haliyo, S. D., & Régnier, S. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/5/055207 · Cited by 36
Ying, Z. C., Reitsma, M. G., & Gates, R. S. (2007) · Review of Scientific Instruments · doi:10.1063/1.2747095 · Cited by 36
The noise of coated cantilevers
Labuda, A., Bates, J. R., & Grütter, P. (2011) · Nanotechnology · doi:10.1088/0957-4484/23/2/025503 · Cited by 35
On the importance of precise calibration techniques for an atomic force microscope
Emerson, R. J., & Camesano, T. A. (2005) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.11.008 · Cited by 35
Contact mechanics of highly porous oxide nanoparticle agglomerates
Fabre, A., Salameh, S., Ciacchi, L. C., Kreutzer, M. T., & van Ommen, J. R. (2016) · Journal of Nanoparticle Research · doi:10.1007/s11051-016-3500-4 · Cited by 34
Towards screening of inhalation formulations: measuring interactions with atomic force microscopy
Bunker, M., Davies, M. C., & Roberts, C. J. (2005) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2.4.613 · Cited by 34
Self-citationRelative humidity control for atomic force microscopes
Stukalov, O. M., Murray, C. A., Jacina, A., & Dutcher, J. (2006) · Review of Scientific Instruments · doi:10.1063/1.2182625 · Cited by 33
Chung, K., Pratt, J. R., & Reitsma, M. G. (2009) · Langmuir · doi:10.1021/la902488r · Cited by 33
Gates, R. S., Reitsma, M. G., Kramar, J. A., & Pratt, J. R. (2011) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.116.015 · Cited by 33
AFM Investigation of Liquid-Filled Polymer Microcapsules Elasticity
Sarrazin, B., Tsapis, N., Mousnier, L., Taulier, N., Urbach, W., & Guénoun, P. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b00431 · Cited by 33
Thio, B. J. R., Lee, J., Meredith, J. C., & Keller, A. A. (2010) · Langmuir · doi:10.1021/la1020516 · Cited by 34
Measuring the thickness of ultra-thin diamond-like carbon films
Lemoine, P., Quinn, J. P., Maguire, P. D., & McLaughlin, J. A. (2006) · Carbon · doi:10.1016/j.carbon.2006.04.029 · Cited by 33
Vlassov, S., Bocharov, D. V., Polyakov, B., Vahtrus, M., Šutka, A., Oras, S., Zadin, V., & Kyritsakis, A. (2023) · Nanotechnology Reviews · doi:10.1515/ntrev-2022-0505 · Cited by 32
Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers
Golovko, D. S., Haschke, T., Wiechert, W., & Bonaccurso, E. (2007) · Review of Scientific Instruments · doi:10.1063/1.2720727 · Cited by 32
Laurent, J., Steinberger, A., & Bellon, L. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/22/225504 · Cited by 32
Dimitrievski, K., Zäch, M., Zhdanov, V. P., & Kasemo, B. (2006) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2005.12.002 · Cited by 31
Muntwyler, S., Kratochvil, B. E., Beyeler, F., & Nelson, B. J. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2067443 · Cited by 31
Silva, E. C. C. M., & Vliet, K. J. V. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/21/038 · Cited by 31
Zhang, Y., Zhu, X., & Chen, B. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c00211 · Cited by 30
Review and perspectives of AFM application on the study of deformable drop/bubble interactions
Wang, W., Li, K., Ma, M., Jin, H., Angeli, P., & Gong, J. (2015) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2015.08.005 · Cited by 30
Direct measurement of spatial modes of a microcantilever from thermal noise
Paolino, P., Tiribilli, B., & Bellon, L. (2009) · Journal of Applied Physics · doi:10.1063/1.3245394 · Cited by 30
Self-Calibration and Performance Control of MEMS with Applications for IoT
Clark, J. (2018) · Sensors · doi:10.3390/s18124411 · Cited by 30
Bédoui, F., Sansoz, F., & Murthy, N. S. (2008) · Acta Materialia · doi:10.1016/j.actamat.2008.01.021 · Cited by 30
Hemicelluloses at Interfaces: Some Aspects of the Interactions
Tammelin, T., Paananen, A., & Österberg, M. (2009) · Wiley eBooks · doi:10.1002/9781444307474.ch6 · Cited by 29
High-bandwidth piezoresistive force probes with integrated thermal actuation
Doll, J. C., & Pruitt, B. L. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/9/095012 · Cited by 29
Importance of LPS structure on protein interactions with Pseudomonas aeruginosa
Atabek, A., Liu, Y., Pinzón‐Arango, P. A., & Camesano, T. A. (2008) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2008.08.013 · Cited by 30
Carniello, V., Harapanahalli, A. K., Busscher, H. J., & van der Mei, H. C. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.10.024 · Cited by 29
Ge, X., Xiao, X., Zhang, Y., Zhu, X., Chu, C., & Chen, B. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.4c12300 · Cited by 28
Extracting physics of life at the molecular level: A review of single-molecule data analyses
Colomb, W., & Sarkar, S. K. (2015) · Physics of Life Reviews · doi:10.1016/j.plrev.2015.01.017 · Cited by 28
Zhang, Y., Zhu, X., & Chen, B. (2021) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2021.09.131 · Cited by 28
Stärk, M., Guckenberger, R., Stemmer, A., & Stark, R. W. (2005) · Journal of Applied Physics · doi:10.1063/1.2137887 · Cited by 28
Exploring the Nano-Surface of Collagenous and Other Fibrotic Tissues with AFM
Stylianou, A., Gkretsi, V., Patrickios, C. S., & Stylianopoulos, T. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7113-8_29 · Cited by 27
One-Step Calibration of AFM in Liquid
Sumbul, F., Hassanpour, N., Rodriguez-Ramos, J., & Rico, F. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.00301 · Cited by 27
Xie, H., Vitard, J., Haliyo, S. D., & Régnier, S. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.920722 · Cited by 27
Inorganic nanoparticles for the theranostics of cancer
Verma, J., Lal, S., & Noorden, C. J. F. V. (2015) · European Journal of Nanomedicine · doi:10.1515/ejnm-2015-0024 · Cited by 27
Thermal noise of microcantilevers in viscous fluids
Bellon, L. (2008) · Journal of Applied Physics · doi:10.1063/1.3021102 · Cited by 26
Zhang, H., Molino, P. J., Wallace, G. G., & Higgins, M. J. (2015) · Scientific Reports · doi:10.1038/srep13334 · Cited by 26
Allen, M. S., Sumali, H., & Penegor, P. C. (2009) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4000160 · Cited by 26
A metrological approach for the calibration of force transducers with interferometric readout
Beekmans, S. V., & Iannuzzi, D. (2015) · Surface Topography Metrology and Properties · doi:10.1088/2051-672x/3/2/025004 · Cited by 25
Johnstone, L. R., Gómez, I., Lin, H., Fadiran, O. O., Chen, V. W., Meredith, J. C., & Perry, J. W. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b15664 · Cited by 25
Measuring the force of single protein molecule detachment from surfaces with AFM
Tsapikouni, T. S., & Missirlis, Y. F. (2009) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2009.08.041 · Cited by 25
Asymptotic analysis of a noncontact AFM microcantilever sensor with external feedback control
Settimi, V., Gottlieb, O., & Rega, G. (2014) · Nonlinear Dynamics · doi:10.1007/s11071-014-1840-0 · Cited by 24
DNA analysis by single molecule stretching in nanofluidic biochips
Abad, E., Juarros, A., Retolaza, A., Merino, S., Marie, R., & Kristensen, A. (2010) · Microelectronic Engineering · doi:10.1016/j.mee.2010.11.025 · Cited by 24
Membrane-Protein Unfolding Intermediates Detected with Enhanced Precision Using a Zigzag Force Ramp
Jacobson, D. R., Uyetake, L., & Perkins, T. T. (2019) · Biophysical Journal · doi:10.1016/j.bpj.2019.12.003 · Cited by 24
Understanding Solvation in Hydrofluoroalkanes: Ab Initio Calculations and Chemical Force Microscopy
Wu, L., Peguin, R. P. S., & da Rocha, S. R. P. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp071205y · Cited by 24
Abad, E., Merino, S., Retolaza, A., & Juarros, A. (2008) · Microelectronic Engineering · doi:10.1016/j.mee.2007.12.048 · Cited by 24
Cantilever Spring-Constant Calibration in Atomic Force Microscopy
Cumpson, P. J., Clifford, C. A., Portolés, J. F., Johnstone, J. E., & Munz, M. (2007) · Springer eBooks · doi:10.1007/978-3-540-74080-3_8 · Cited by 24
Keyvani, A., Sadeghian, H. M., Tamer, M. S., Goosen, J. F. L., & van Keulen, F. (2017) · Journal of Applied Physics · doi:10.1063/1.4990276 · Cited by 23
Direct Observation of Alginate-Promoted Soil Phosphorus Availability
Ge, X., Wang, L., & Zhang, W. (2022) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.2c01864 · Cited by 22
Microfabricated torsion levers optimized for low force and high-frequency operation in fluids
Beyder, A., & Sachs, F. (2006) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.11.014 · Cited by 22
Odorico, M., Teulon, J., Berthoumieu, O., Chen, S. W., Parot, P. H., & Pellequer, J. (2007) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.04.019 · Cited by 22
Frentrup, H., & Allen, M. S. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/29/295703 · Cited by 21
Dey, A., & Szoszkiewicz, R. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/17/175101 · Cited by 21
Dynamic force spectroscopy for quantifying single-molecule organo–mineral interactions
Zhai, H., Zhang, W., Wang, L., & Putnis, C. V. (2021) · CrystEngComm · doi:10.1039/d0ce00949k · Cited by 21
Measurement of polyphenol–membrane interaction forces during the ultrafiltration of black tea liquor
Evans, P. J., Bird, M. R., Rogers, D., & Wright, C. J. (2008) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2008.11.023 · Cited by 21
Nanomanipulation with the Atomic Force Microscope
Requicha, A. A. G. (2010) · Wiley eBooks · doi:10.1002/9783527628155.nanotech027 · Cited by 21
Direct measurement of spatial modes of a microcantilever from thermal noisePreprint
Paolino, P., Tiribilli, B., & Bellon, L. (n.d.) · Cited by 21
Zia, J., & Riaz, U. (2020) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-020-04812-7 · Cited by 20
Nielsen, A. R., Jelavić, S., Murray, D. J., Rad, B., Andersson, M., Ceccato, M., Mitchell, A. C., Stipp, S. L. S., Zuckermann, R. N., & Sand, K. K. S. (2020) · Crystal Growth & Design · doi:10.1021/acs.cgd.0c00029 · Cited by 20
AFM-Based Single-Molecule Force Spectroscopy of Proteins
Scholl, Z. N., & Marszałek, P. E. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-8591-3_3 · Cited by 20
Structural and Dynamic Characterization of Biochemical Processes by Atomic Force Microscopy
Eghiaian, F., & Schaap, I. A. T. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-261-8_6 · Cited by 20
Microactuator device for integrated measurement of epithelium mechanics
Mukundan, V., Nelson, W. J., & Pruitt, B. L. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9693-0 · Cited by 19
A high-resolution resonant torque sensor based on MEMS quartz resonator
Ding, Y., Ren, Z., Wang, S., Jing, W., Jiang, Z., & Wei, X. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112579 · Cited by 19
Targosz‐Korecka, M., Biedroń, R., Szczygiel, A. M., Brzezinka, G., Szczerbiński, J., & Zuk, A. (2012) · Journal of Molecular Recognition · doi:10.1002/jmr.2192 · Cited by 19
Mishra, R., Grange, W., & Hegner, M. (2011) · Journal of Sensors · doi:10.1155/2012/617386 · Cited by 19
Direct thermal noise calibration of colloidal probe cantilevers
Heim, L., Rodrigues, T. S., & Bonaccurso, E. (2013) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2013.11.018 · Cited by 19
Metadata
- Authors
- Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B.
- Affiliations
- Worcester Polytechnic Institute (US)
- University of Nottingham (GB)
- University of Leeds (GB)
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2002-12-04
- Volume
- 14
- Issue
- 1
- Pages
- 1-6
- ISSN
- 0957-4484 (ISSN-L)
- OpenAlex
- W2105665577
- Semantic Scholar
- 12f0d9ba4e490824f14c52b5888c8d74f0a80bb4
- Cited by
- 458
- References
- 20
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 8 · 2023: 7 · 2022: 9 · 2021: 9 · 2020: 14 · 2019: 17 · 2018: 20 · 2017: 22 · 2016: 16 · 2015: 20 · 2014: 13 · 2013: 26 · 2012: 34
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Nanotechnology (publishedVersion)
- Funders
- Biotechnology and Biological Sciences Research Council
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- atomic force microscopy cantilevers, cantilever stiffness, thermal noise, amplitude fluctuations, calibration method comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.