Comparison of calibration methods for atomic-force microscopy cantilevers
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The scientific community needs a rapid and reliable way of accurately determining the stiffness of atomic-force microscopy cantilevers. We have compared the experimentally determined values of stiffness for ten cantilever probes using four different methods. For rectangular silicon cantilever beams of well defined geometry, the approaches all yield values within 17% of the manufacturer’s nominal stiffness. One of the methods is new, based on the acquisition and analysis of thermal distribution functions of the oscillator’s amplitude fluctuations. We evaluate this method in comparison to the three others and recommend it for its ease of use and broad applicability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Similarly, the force F was determined by recording the AFM cantilever deflection during sample deformation and knowing the spring constant of the AFM cantilever, calibrated using the thermal noise method [25]. The error in force measurements using this calibration method has been shown to be lower than 5% [26].”
From Extreme strength observed in limpet teeth (2015) · cites this paper as [26]
Citations
Cites
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Biological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Research works printed but not linked: 1
- Hazel J L, 1996, Polym. Preparation, 37, 567
Cited by
Items 301–400 of 522
Scanning Probe Microscopy of Polymers
Sheiko, S. S., & Magonov, S. (2012) · Elsevier eBooks · doi:10.1016/b978-0-444-53349-4.00047-9 · Cited by 7
Energy dissipation of a contact line moving on a nanotopographical defect
Franiatte, S., Paredes, G., Ondarçuhu, T., & Tordjeman, P. (2024) · Soft Matter · doi:10.1039/d4sm00161c · Cited by 6
COVID-19 Infection Changes the Functions and Morphology of Erythrocytes: A Multidisciplinary Study
Sales, M. V. D. S., Tanabe, E. L. L., Maciel, T., Tavares, M. C., Leal, J., Pinto, L., Pires, K. S. N., Coelho, J. A. P. D. M., Silva, E., Souza, S., et al. (2023) · Journal of the Brazilian Chemical Society · doi:10.21577/0103-5053.20230031 · Cited by 6
The Use of Atomic Force Microscopy in Investigating Particle Caking Mechanisms
Leaper, M. C., & Prime, D. C. (2013) · Chemical Engineering & Technology · doi:10.1002/ceat.201300271 · Cited by 6
Automated stiffness characterization of living tobacco BY2 cells using the Cellular Force Microscope
Felekis, D., Weber, A. R., Muntwyler, S., Routier‐Kierzkowska, A., Beyeler, F., Smith, R. S., & Nelson, B. J. (2012) · IEEE International Conference on Automation Science and Engineering (CASE) · doi:10.1109/coase.2012.6386345 · Cited by 6
Probing Cellular Adhesion at the Single-Molecule Level
Rico, F., Zhang, X. H., & Moy, V. T. (2011) · Pan Stanford Publishing eBooks · doi:10.1201/9780429066597-11 · Cited by 6
Babel, B., & Rudolph, M. (2019) · MethodsX · doi:10.1016/j.mex.2019.03.010 · Cited by 6
Hydrodynamic methods for calibrating the normal spring constant of microcantilevers
Lubarsky, G. V., & Hähner, G. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/32/325707 · Cited by 6
Laher, M., & Hild, S. (2013) · RSC Advances · doi:10.1039/c3ra45167d · Cited by 6
Duman, M., Neundlinger, I., Zhu, R., Preiner, J., Lamprecht, C., Chtcheglova, L. A., Rankl, C., Puntheeranurak, T., Ebner, A., & Hinterdorfer, P. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-374920-8.00213-7 · Cited by 6
Characterization and detection of traces of energetic materials by Nanocalorimetry
Piazzon, N. (2010) · theses.fr (ABES) · doi:10.70675/c2ebbe1fz922az415dzbf42zdf2b05d9d371 · Cited by 6
Comment on “Print your atomic force microscope” [Rev. Sci. Instrum. 78, 075105 (2007)]
Szoszkiewicz, R. (2012) · Review of Scientific Instruments · doi:10.1063/1.3688654 · Cited by 6
The Effect of Biopolymer Properties on Bacterial Adhesion: an Atomic Force Microscopy (AFM) Study
Abu‐Lail, N. I. (2003) · Digital WPI · Cited by 6
Microrhéomètre sur puce pour l'étude de l'écoulement d'un liquide proche d'une surface liquide
Darwiche, A. (2012) · theses.fr (ABES) · doi:10.70675/e51d186ez288fz4d39zbac0z4e72d223cc8b · Cited by 6
Focused electron- and ion-beam induced processes : in situ monitoring, analysis and modeling
Friedli, V. (2008) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-4036 · Cited by 10
Zhang, Y., Zhan, T., Ge, X., Zhu, X., & Chen, B. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c09739 · Cited by 5
Beyond Molecules: In Situ Imaging Unveils DOM-Driven PFAS Nanoclusters with Mitigated Phytotoxicity
Ge, X., Wang, K., Xiao, X., Chu, C., Zhu, X., & Chen, B. (2026) · Environmental Science & Technology · doi:10.1021/acs.est.5c16338 · Cited by 5
Imaging Chemical Groups and Molecular Recognition Sites on Live Cells Using AFM
Alsteens, D., Duprès, V., Dague, É., Verbelen, C., André, G., Francius, G., & Dufrêne, Y. F. (2008) · Nanoscience and technology · doi:10.1007/978-3-540-85039-7_2 · Cited by 5
Ge, X., Zhang, W., Putnis, C. V., & Wang, L. (2022) · Physical Chemistry Chemical Physics · doi:10.1039/d2cp00054g · Cited by 5
Biophysical Methods to Monitor Structural Aspects of the Adenovirus Infectious Cycle
Menéndez-Conejero, R., Perez-Berna, A. J., Condezo, G. N., Ortega-Esteban, Á., del Álamo, M., de Pablo, P. J., & Martín, C. S. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-679-5_1 · Cited by 5
A calibration method for the higher modes of a micro-mechanical cantilever
Shatil, N., Homer, M., Picco, L., Martin, P. G., & Payton, O. (2017) · Applied Physics Letters · doi:10.1063/1.4984222 · Cited by 5
Fraysse, K. S., Meaney, S. P., Gates, W. P., Langley, D., Tabor, R. F., Stoddart, P. R., & Greene, G. W. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.1c11545 · Cited by 5
Felekis, D., Muntwyler, S., Beyeler, F., & Nelson, B. J. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094493 · Cited by 5
Energetic Material/Polymer Interaction Studied by Atomic Force Microscopy
Oxley, J. C., Smith, J. L. D., Kagan, G., Zhang, G., & Swanson, D. S. (2016) · Propellants Explosives Pyrotechnics · doi:10.1002/prep.201500161 · Cited by 5
Study of buckling behavior at the nanoscale through capillary adhesion force
Lorenzoni, M., Llobet, J., & Pérez‐Murano, F. (2018) · Applied Physics Letters · doi:10.1063/1.5026474 · Cited by 5
Characterizing Ferroelectricity with an Atomic Force Microscopy: An All-Around Technique
Martin, S., Gautier, B., Baboux, N., Gruverman, A. L., Carretero‐Genevrier, A., Gich, M., & Gómez, A. (2019) · Nanoscience and technology · doi:10.1007/978-3-030-15612-1_6 · Cited by 5
Hussan, S. M. A. A., Bakr, N. A., & Abd, A. N. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/928/7/072142 · Cited by 5
Local Mechanical Properties by Atomic Force Microscopy Nanoindentations
Tranchida, D., & Piccarolo, S. (2008) · Nanoscience and technology · doi:10.1007/978-3-540-85037-3_7 · Cited by 5
Scanning Probe Microscopy Characterization of Optical Thin Films
Klapetek, P. (2018) · Springer series in surface sciences · doi:10.1007/978-3-319-75325-6_11 · Cited by 5
Dobryden, I., Mensi, E., Holmgren, A., & Almqvist, N. (2020) · Colloids and Interfaces · doi:10.3390/colloids4030041 · Cited by 5
Fukuma, T., & Higgins, M. J. (2012) · Wiley eBooks · doi:10.1002/9783527649808.ch4 · Cited by 5
Soft polymer-based cantilever probe for AFM nanoindentation of live mammalian cells in liquid
Yu, F., Liu, J., Yu, S., Yang, Z., Pan, Y., Gao, N., Zou, Q., & Jeon, J. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181412 · Cited by 5
Effect of Tip Mass on Atomic Force Microscope Calibration by Thermal Method
Allen, M. S., Sumali, H., & Penegor, P. C. (2009) · Cited by 5
AFM to Study Pore-Forming Proteins
Unsay, J. D., & García‐Sáez, A. J. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-8894-5_10 · Cited by 5
Characterization of Magnetic Nanoparticles Using Magnetic Force Microscopy
Agarwal, G. (2009) · Wiley eBooks · doi:10.1002/9783527610419.ntls0177 · Cited by 5
Thoreson, E. J. (2006) · Digital WPI · Cited by 5
Self-citationSzoszkiewicz, R. (2009) · Nanoscience and technology · doi:10.1007/978-3-642-03535-7_12 · Cited by 4
Atomic Force Microscopy and Spectroscopy
Buscarino, G. (2021) · Wiley eBooks · doi:10.1002/9781119698029.ch15 · Cited by 4
BIOSENSORES MECÁNICOS EN EL ÁREA BIOLÓGICA Y ALIMENTARIA: UNA REVISIÓN
Mendoza-Madrigal, A. G., Chanona‐Pérez, J. J., Hernández‐Sánchez, H., Palacios, E., Calderón‐Domínguez, G., Méndez‐Méndez, J. V., Blasco, J., & Villa‐Vargas, L. A. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 4
Microforce-Sensing Tools and Methodologies for Micromechanical Metrology
Muntwyler, S., Beyeler, F., & Nelson, B. J. (2011) · Springer eBooks · doi:10.1007/978-1-4419-9946-7_4 · Cited by 4
Bao, C., Wang, Z., Liu, Y., Zhang, Y., Nie, H., Lau, W., & Mei, J. (2017) · Journal of Applied Polymer Science · doi:10.1002/app.45166 · Cited by 4
Graphene used as a lateral force microscopy calibration material in the low-load non-linear regime
Boland, M. J., Hempel, J. L., Ansary, A., Nasseri, M., & Strachan, D. R. (2018) · Review of Scientific Instruments · doi:10.1063/1.5044727 · Cited by 4
Fraysse, K. S., MacLeod, A. J. N., Gates, W. P., Langley, D., & Greene, G. W. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201297 · Cited by 4
New AFM Developments to Study Elasticity and Adhesion at the Nanoscale
Szoszkiewicz, R., & Riedo, E. (2006) · Nanoscience and technology · doi:10.1007/978-3-540-37316-2_9 · Cited by 4
Kim, M., Choi, J.-H., & Park, Y.-K. (2006) · SICE-ICASE International Joint Conference · doi:10.1109/sice.2006.314740 · Cited by 4
Force Measurement by AFM Cantilever with Different Coating Layers
Yeh, M. K., Chen, B. Y., Tai, N. H., & Chiu, C. C. (2006) · Key engineering materials · doi:10.4028/www.scientific.net/kem.326-328.377 · Cited by 4
Wu, D., Yi-Zhen, W., & Jin-Xiu, Z. (2007) · Chinese Physics Letters · doi:10.1088/0256-307x/24/10/056 · Cited by 4
Calibration and nonlinearity compensation for force application in AFM based nanomanipulation
Xie, H., Vitard, J., Haliyo, S. D., & Régnier, S. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4650618 · Cited by 4
Similarity Approach to Hertz Type Contact Problems
Galanov, B. A. (2008) · IUTAM bookseries · doi:10.1007/978-1-4020-9033-2_11 · Cited by 4
Atomic force microscopy study on the mechanics of influenza viruses and liposomes
Li, S. (2012) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-2900 · Cited by 4
Studies of Surfactant Behaviour and Model Surfaces Relevant to Flotation Deinking
Theander, K. (2006) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 4
Intermolecular Interactions of Energetic Materials
Swanson, D. S. (2016) · Digital Commons - URI (University of Rhode Island) · doi:10.23860/diss-swanson-devon-2016 · Cited by 4
The Force Feedback Microscope : an AFM for soft condensed matter
Costa, L. (2014) · theses.fr (ABES) · doi:10.70675/9e313641zb16az459az8d1czc1650a22ad40 · Cited by 4
Buchoux, J. (2011) · theses.fr (ABES) · doi:10.70675/69b5570dz0675z4dacz8d48z15f5fcb34cd2 · Cited by 4
Oster, S. (2012) · theses.fr (ABES) · doi:10.70675/9a1f7b89z7189z478cz9818zc4207252f0ed · Cited by 5
Hatchell, C. B., & Jacobson, D. R. (2025) · Review of Scientific Instruments · doi:10.1063/5.0257032 · Cited by 3
Stiffness calibration of qPlus sensors at low temperature through thermal noise measurements
Nony, L., Clair, S., Uehli, D., Herrero, A., Themlin, J.-M., Campos, A. P. C., Para, F., Pioda, A., & Loppacher, C. (2024) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.15.50 · Cited by 3
Shaharyar, M., MacFarlane, D. R., Kar, M., Sourjah, A., Fraysse, K. S., Doherty, C. M., Acharya, D. P., O'Dell, L. A., & Pringle, J. M. (2024) · Journal of Membrane Science · doi:10.1016/j.memsci.2024.123232 · Cited by 3
Talukdar, A. (2014) · Scholar Commons (University of South Carolina) · Cited by 3
Atomic Force Microscope Cantilevers Used as Sensors for Monitoring Microdrop Evaporation
Bonaccurso, E., Golovko, D. S., Bonanno, P., Raiteri, R., Haschke, T., Wiechert, W., & Butt, H. (2008) · Nanoscience and technology · doi:10.1007/978-3-540-85037-3_2 · Cited by 3
Grytsenko, K. (2009) · Optical Memory and Neural Networks · doi:10.3103/s1060992x09040079 · Cited by 3
Azcona, F. J., Jha, A., Yáñez, C., Atashkhooei, R., & Royo, S. (2016) · Sensors · doi:10.3390/s16070997 · Cited by 3
Cell Visco-Elasticity Measured with AFM and Vertical Optical Trapping at Sub-Micrometer Deformations
Nawaz, S., Sánchez, P., Bodensiek, K., Li, S., Simons, M., & Schaap, I. A. T. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2012.11.2643 · Cited by 3
Force and Mechanical Properties
Klapetek, P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813347-7.00006-6 · Cited by 3
Atomic Force Microscopy Studies of the Mechanical Properties of Living Cells
Rico, F., Wojcikiewicz, E. P., & Moy, V. T. (2009) · Springer eBooks · doi:10.1007/978-3-642-02405-4_19 · Cited by 3
Zhang, Y., Zhu, X., Zhu, B., Chu, C., & Chen, B. (2023) · Small Structures · doi:10.1002/sstr.202300156 · Cited by 3
Synthesis of One-Dimensional Chalcogenides by a Novel Hydrothermal Process
Zhang, H., Yang, D. R., Ji, Y., Xiang, Y., Xu, J. B., & Que, D. L. (2004) · Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomena · doi:10.4028/www.scientific.net/ssp.99-100.203 · Cited by 3
A direct micropipette-based calibration method for atomic force microscope cantilevers
Liu, B., Yu, Y. J., Yao, D.-K., & Shao, J. (2009) · Review of Scientific Instruments · doi:10.1063/1.3152220 · Cited by 3
Cooperative Multiwalled Carbon Nanotubes for Enhanced Force Spectroscopy
Rius, G., & Yoshimura, M. (2012) · e-Journal of Surface Science and Nanotechnology · doi:10.1380/ejssnt.2012.341 · Cited by 3
Force and Mechanical Properties
Klapetek, P. (2012) · Elsevier eBooks · doi:10.1016/b978-1-45-573058-2.00006-1 · Cited by 3
Nanomechanics of Single Biomacromolecules
Li, Q., Scholl, Z. N., & Marszałek, P. E. (2014) · Springer eBooks · doi:10.1007/978-3-642-31107-9_13 · Cited by 3
Combined Voltage-Clamp and Atomic Force Microscope for the Study of Membrane Electromechanics
Beyder, A., & Sachs, F. (2010) · Springer eBooks · doi:10.1007/978-1-4419-7167-8_16 · Cited by 3
The reaction kinetics of NiCl2 in silica–alumina gel matrix
Mallick, S., Das, G. C., Mukherjee, S., & Mitra, M. K. (2006) · Journal of Physics and Chemistry of Solids · doi:10.1016/j.jpcs.2006.03.018 · Cited by 3
Effects of geometric nonlinearity in an adhered microbeam for measuring the work of adhesion
Fang, W., Mok, J., & Kesari, H. (2018) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2017.0594 · Cited by 3
Robust and Efficient Parametric Spectral Density Estimation for High-Throughput Data
Lysy, M., Zhu, F., Yates, B., & Labuda, A. (2021) · Technometrics · doi:10.1080/00401706.2021.1884134 · Cited by 3
Nanomechanical spectroscopy of ultrathin silicon nitride suspended membranes
Jugade, S., Aggarwal, A., & Naik, A. K. (2021) · The European Physical Journal Applied Physics · doi:10.1051/epjap/2021210068 · Cited by 3
Besleaga, A., Apetrei, A., & Sirghi, L. (2022) · European Biophysics Journal · doi:10.1007/s00249-021-01580-y · Cited by 3
Kopycinska‐Müller, M., Caron, A., Hirsekorn, S., Rabe, U., Natter, H., Hempelmann, R., Birringer, R., & Arnold, W. (2008) · R. Oldenbourg Verlag eBooks · doi:10.1524/9783486598674.247 · Cited by 3
Silva, E. C. C. M. (2007) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 3
Camps, F. (2006) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) · Cited by 3
Jaloustre, L. (2019) · theses.fr (ABES) · doi:10.70675/8fbc1ea9z6602z4a59z89acz973f8a28399e · Cited by 3
Sarrazin, B. (2015) · theses.fr (ABES) · doi:10.70675/726f2b8cze70ez479aza135z86f98c74f245 · Cited by 3
Nanomechanical thermometry for probing sub-nW thermal transport
Oh, S., Shekhawat, N. S., Jameel, O., Lal, A., & Lee, C. H. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00770-w · Cited by 2
Contact Line Motion over a Surface Asperity: Jumping and Energy Dissipation
Sherafatpour, J., Tordjeman, P., & Ondarçuhu, T. (2025) · Langmuir · doi:10.1021/acs.langmuir.5c05196 · Cited by 2
Application of Contact Mode AFM to Manufacturing Processes
Giordano, M., & Schmid, S. R. (2009) · Nanoscience and technology · doi:10.1007/978-3-642-03535-7_25 · Cited by 2
Research on the Wind Energy Technology of Germany Based on Patent Analysis
Xiao-Ping, L., Runsheng, L., Zhao, Y.-H., & Jia, Z. (2011) · Advances in intelligent and soft computing · doi:10.1007/978-3-642-25194-8_84 · Cited by 2
Recognition Imaging Using Atomic Force Microscopy
Ebner, A., Chtcheglova, L. A., Tang, J., Alsteens, D., Duprès, V., Dufrêne, Y. F., & Hinterdorfer, P. (2009) · Springer eBooks · doi:10.1007/978-0-387-76497-9_18 · Cited by 2
Microsystem for Real Time High Resolution Measurement of Cell Forces
Swierczewski, R., Vázquez, J., Hedley, J., Birch, M., & Redfern, C. P. F. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2238627 · Cited by 2
Snow, D. E., Weeks, B. L., Kim, D. J., Pitchimani, R., & Hope‐Weeks, L. J. (2008) · Review of Scientific Instruments · doi:10.1063/1.2969031 · Cited by 2
Utzig, T., Stock, P., Raman, S., & Valtiner, M. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b02746 · Cited by 2
Calibration of normal force in atomic force microscope
Ekwińska, M. A., Ekwinski, G., & Rymuza, Z. (2007) · Springer eBooks · doi:10.1007/978-3-540-73956-2_99 · Cited by 2
Tribologische Mess- und Prüftechnik
Czichos, H., & Stürm, H. (2015) · Springer eBooks · doi:10.1007/978-3-8348-2236-9_8 · Cited by 2
Tranchida, D., & Piccarolo, S. (2009) · Nanoscience and technology · doi:10.1007/978-3-642-03535-7_7 · Cited by 2
A Comprehensive Model for Stiffness Coefficients in V-Shaped Cantilevers
Korayem, A. H., Hoshiar, A. K., Badrlou, S., & Korayem, M. H. (2016) · International journal of nanoscience and nanotechnology · Cited by 2
Jiang, J., Hu, G., & Zhang, Z. (2017) · ACTA IMEKO · doi:10.21014/acta_imeko.v6i2.336 · Cited by 2
The Effect of Morphology on the Biodegradation Behavior of Porous Magnesium Bone Scaffold
Basri, H., Syahrom, A., Saad, A. P. M., Rabiatul, A. A., Teguh, P. A., Diansyah, A., & Putra, R. U. (2018) · E3S Web of Conferences · doi:10.1051/e3sconf/20186801020 · Cited by 2
Nanoscale Friction: Measurement and Analysis
Chung, Y.-W. (2011) · CRC Press eBooks · doi:10.1201/b11211-8 · Cited by 2
Imaging Chemical Groups and Molecular Recognition Sites on Live Cells Using AFM
Alsteens, D., Duprès, V., Dague, É., Verbelen, C., André, G., Francius, G., & Dufrêne, Y. F. (2009) · Springer eBooks · doi:10.1007/978-3-642-02405-4_16 · Cited by 2
Bacterial adhesion forces and biofilm prevention on orthodontic materials
Mei, L. (2011) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 2
Dosing of femto liter volumes using hollow cantilever AFM
Gruiter, R. B. T. D. (2015) · Research Repository (Delft University of Technology) · Cited by 2
Metadata
- Authors
- Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B.
- Affiliations
- Worcester Polytechnic Institute (US)
- University of Nottingham (GB)
- University of Leeds (GB)
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2002-12-04
- Volume
- 14
- Issue
- 1
- Pages
- 1-6
- ISSN
- 0957-4484 (ISSN-L)
- OpenAlex
- W2105665577
- Semantic Scholar
- 12f0d9ba4e490824f14c52b5888c8d74f0a80bb4
- Cited by
- 458
- References
- 20
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 8 · 2023: 7 · 2022: 9 · 2021: 9 · 2020: 14 · 2019: 17 · 2018: 20 · 2017: 22 · 2016: 16 · 2015: 20 · 2014: 13 · 2013: 26 · 2012: 34
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Nanotechnology (publishedVersion)
- Funders
- Biotechnology and Biological Sciences Research Council
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- atomic force microscopy cantilevers, cantilever stiffness, thermal noise, amplitude fluctuations, calibration method comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.