Detection of magnetic nanoparticles in tissue using magneto-motive ultrasound
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to demonstrate the magneto-motive ultrasonic detection of superparamagnetic iron oxide (SPIO) nanoparticles as a marker of macrophage recruitment in tissue. The capability of ultrasound to detect SPIO nanoparticles (core diameter ∼20 nm) taken up by murine liver macrophages was investigated. Eight mice were sacrificed two days after the intravenous administration of four SPIO doses (1.5, 1.0, 0.5, and 0.1 mmol Fe/kg body weight). In the iron-laden livers, ultrasound Doppler measurements showed a frequency shift in response to an applied time-varying magnetic field. M-mode scan and colour power Doppler images of the iron-laden livers also demonstrated nanoparticle movement under focused magnetic field excitation. In the livers of two saline injected control mice, no movement was observed using any ultrasound imaging modes. The results of our experiments indicate that ultrasound imaging of magneto-motive excitation is a candidate imaging modality to identify tissue-based macrophages containing SPIO nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Atherosclerosis is an inflammatory disease
Ross, R. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70266-8 · Cited by 1,451
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045 · cited 2×
“Peak concentrations of SPIO nanoparticles in the liver were observed 1 h after an intravenous injection (18 μmol Fe/kg body weight) [14].”
MethodHigh-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882 · cited 1×
“Third, the strong magnetic susceptibility of superparamagnetic nanoparticles combined with an externally applied magnetic field offers attractive possibilities in biomedicine and research in targeted drug delivery [29], molecular imaging [30], magnetic biosensing [31], and magnetic separation [32].”
BackgroundClinical Applications of Magnetic Drug Targeting
Lübbe, A. S., Alexiou, C., & Bergemann, C. (2001) · Journal of Surgical Research · doi:10.1006/jsre.2000.6030 · Cited by 844 · cited 1×
“Third, the strong magnetic susceptibility of superparamagnetic nanoparticles combined with an externally applied magnetic field offers attractive possibilities in biomedicine and research in targeted drug delivery [ 29 ], molecula ri maging [30], magnetic biosensing [31], and magnetic separation [32].”
BackgroundKooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Ultrasound contrast agents: properties, principles of action, tolerance, and artifacts
Correas, J.-M., Bridal, L., Lesavre, A., Méjean, A., Claudon, M., & Hélénon, O. (2001) · European Radiology · doi:10.1007/s003300100940 · Cited by 435
Molecular Imaging in the Clinical Arena
Jaffer, F. A. (2005) · JAMA · doi:10.1001/jama.293.7.855 · Cited by 369 · cited 1×
“Nanometre-sized ultrasound contrast agents may penetrate the large capillary bed, but penetration to vasculature targets and extravasations through tight capillary pores could be inhibited due to their relatively large size [6, 7 ]. Unfortunately, PFC ultrasound contrast agents produced a smaller acoustic impedance mi…”
BackgroundPetri-Fink, A., Chastellain, M., Juillerat-Jeanneret, L., Ferrari, A., & Hofmann, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.023 · Cited by 343 · cited 1×
“recently expanded from the diagnosis of hepatic metastases to agents that target an inflammatory response in several diseases, particularly in atherosclerosis [17, 18] and tumours [19].”
BackgroundMultiple pathways of capillary permeability.
Renkin, E. M. (1977) · Circulation Research · doi:10.1161/01.res.41.6.735 · Cited by 308
SCHMITZ, S. A., COUPLAND, S. E., GUST, R., WINTERHALTER, S., WAGNER, S., KRESSE, M., SEMMLER, W., & WOLF, K.-J. (2000) · Investigative Radiology · doi:10.1097/00004424-200008000-00002 · Cited by 227
Anzai, Y., Blackwell, K. E., Hirschowitz, S. L., Rogers, J. W., Sato, Y., Yuh, W. T., Runge, V. M., Morris, M. R., McLachlan, S. J., & Lufkin, R. B. (1994) · Radiology · doi:10.1148/radiology.192.3.7520182 · Cited by 220
Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles
Schmitz, S. A., Taupitz, M., Wagner, S., Wolf, K., Beyersdorff, D., & Hamm, B. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1194 · Cited by 208
Reimer, P., Jähnke, N., Fiebich, M., Schima, W., Deckers, F., Marx, C., Holzknecht, N., & Saini, S. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc31152 · Cited by 188
Enhancement of AC-losses of magnetic nanoparticles for heating applications
Hergt, R., Hiergeist, R., Zeisberger, M., Glöckl, G., Weitschies, W., Ramirez, L. P., Hilger, I., & Kaiser, W. A. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2004.03.034 · Cited by 187 · cited 1×
“A magnetic field, for example, might be used to induce magnetic hyperthermia to destroy cancer cells in surrounding tissues [ 33 , 34].”
Kalambur, V. S., Han, B., Hammer, B. E., Shield, T. W., & Bischof, J. C. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/8/041 · Cited by 175 · cited 1×
“A magnetic field, for example, might be used to induce magnetic hyperthermia to destroy cancer cells in surrounding tissues [33, 34].”
BackgroundPeroxidase Substrate Nanosensors for MR Imaging
Pérez, J. M. S., Simeone, F. J., Tsourkas, A., Josephson, L., & Weissleder, R. (2003) · Nano Letters · doi:10.1021/nl034983k · Cited by 135
Remsen, L. G., McCormick, C. I., Roman-Goldstein, S., Nilaver, G., Weissleder, R., Bogdanov, A. A., Jr., Hellström, K. E., Kroll, R. A., & Neuwelt, E. A. (1996) · PubMed Central · Cited by 123
Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.4.771 · Cited by 122
Litovsky, S., Madjid, M., Zarrabi, A., Casscells, S. W., Willerson, J. T., & Naghavi, M. (2003) · Circulation · doi:10.1161/01.cir.0000055323.57885.88 · Cited by 118
40-MHz echocardiography scanner for cardiovascular assessment of mouse embryos
Aristizábal, O., Christopher, D. A., Foster, F. S., & Turnbull, D. H. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00132-x · Cited by 94 · cited 1×
“frequency) [27] or scanning acoustic microscopy (SAM; 200 MHz operation frequency) [28] may be more attractive in ultrasound molecular imaging and may provide a dramatic”
BackgroundTuretschek, K., Roberts, T. P. L., Floyd, E., Preda, A., Novikov, V., Shames, D. M., Carter, W. O., & Brasch, R. C. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1126 · Cited by 80 · cited 1×
“stability due to dextran coating; therefore, these nanoparticles can be taken up by macrophages in atherosclerotic vulnerable plaque [24] and malignant tumours [25, 26].”
BackgroundMarsh, J. N., Hall, C. S., Scott, M. J., Fuhrhop, R. W., Gaffney, P. J., Wickline, S. A., & Lanza, G. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.981381 · Cited by 67
Characteristics of Ultrasmall Superparamagnetic Iron Oxides in Patients with Brain Tumors
Taschner, C. A., Wetzel, S. G., Tolnay, M., Froehlich, J., Merlo, A., & Radue, E. W. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1286 · Cited by 39 · cited 1×
“The smaller USPIO and MION (hydrodynamic size: 15–30 nm) have a longer intravascular blood half-life, between 24 and 36 h, and increased relative stability due to dextran coating; therefore, these nanoparticles can be taken up by macrophages in atherosclerotic vulnerable plaque [24 ]a nd malignant tumours [ 25 , 26].”
BackgroundIron particles enhance visualization of experimental gliomas with high-resolution sonography.
Nolte, I. S., Vince, G. H., Mäurer, M., Herbold, C., Goldbrunner, R., Solymosi, L., Stoll, G., & Bendszus, M. (2005) · PubMed · Cited by 31
Intrapancreatic Accessory Spleen: Diagnosis with RES-Specific Contrast-Enhanced MRI
Boraschi, P., Donati, F., Volpi, A., & Campori, G. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.5.01841712 · Cited by 23
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Engineered nanoparticles in wastewater and wastewater sludge – Evidence and impacts
Brar, S. K., Verma, M., Tyagi, R. D., & Surampalli, R. Y. (2010) · Waste Management · doi:10.1016/j.wasman.2009.10.012 · Cited by 716
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Biomedical applications of nanotechnology
Ramos, A. P., Cruz, M. A. E., Tovani, C. B., & Ciancaglini, P. (2017) · Biophysical Reviews · doi:10.1007/s12551-016-0246-2 · Cited by 413
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Metadata
- Authors
- Oh, J., Feldman, M. D., Kim, J., Condit, C., Emelianov, S., & Milner, T. E.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2006-08-01
- Volume
- 17
- Issue
- 16
- Pages
- 4183-4190
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2016697359
- Cited by
- 212
- References
- 28
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.