A 32-site neural recording probe fabricated by DRIE of SOI substrates
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
An all-dry silicon-etch based micromachining process for neural probes was demonstrated in the manufacture of a probe with a 32-site recording electrode array. The fork-like probe shafts were formed by double-sided deep reactive ion etching (DRIE) of a silicon-on-insulator (SOI) substrate, with the buried SiO 2 layer acting as an etch stop. The shafts typically had the dimensions 5 mm × 25 μm × 20 μm and ended in chisel-shaped tips with lateral taper angles of 4°. An array of Ir electrodes, each 100 μm 2 , and Au conductor traces were formed on top of the shafts by e-beam evaporation. An accompanying interconnect solution based on flexible printed circuitry was designed, enabling precise and flexible positioning of the probes in neural tissue. SEM studies showed sharply defined probes and probe tips. The electrical yield and function were verified in bench-top measurements in saline. The magnitude of the electrode impedance was in the 1 MΩ range at 1 kHz, which is consistent with neurophysiological recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 301
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144
Kewley, D. T., Hills, M. D., Borkholder, D. A., Opris, I. E., Maluf, N. I., Storment, C. W., Bower, J. M., & Kovacs, G. T. A. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80221-x · Cited by 131
Stieglitz, T., & Gross, M. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)01021-8 · Cited by 71
Thin-film multielectrode arrays for a cochlear prosthesis
Shamma-Donoghue, S. A., May, G. A., Cotter, N. E., White, R. L., & Simmons, F. B. (1982) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1982.20671 · Cited by 56
Takahashi, K., & Matsuo, T. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)87009-2 · Cited by 47
Chicurel, M. (2001) · Nature · doi:10.1038/35085727 · Cited by 39
A new neural probe using SOI wafers with topological interlocking mechanisms
Cheung, K. C., Lee, G., Djupsund, K., Dan, Y., & Lee, L. P. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893836 · Cited by 26
Cited by
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Metadata
- Authors
- Norlin, P., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. G.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2002-06-14
- Volume
- 12
- Issue
- 4
- Pages
- 414-419
- ISSN
- 0960-1317 (ISSN-L)
- OpenAlex
- W2111026673
- Cited by
- 184
- References
- 13
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.