Measurement of endogenous acetone and isoprene in exhaled breath during sleep
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This explorative study aims at characterizing the breath behavior of two prototypic volatile organic compounds, acetone and isoprene, during normal human sleep and to possibly relate changes in the respective concentration time courses to the underlying sleep architecture. For this purpose, six normal healthy volunteers (two females, four males, age 20-29 years) were monitored over two consecutive nights (the first one being an adaption night) by combining real-time proton-transfer-reaction mass spectrometry measurements from end-tidal exhalation segments with laboratory-based polysomnographic data. Breath acetone concentrations increased overnight in all measurements, with an average relative change by a factor of up to 4 (median 2.5). Nighttime concentration maxima were usually recorded 2-3 h before lights on. For breath isoprene, a nocturnal increase in baseline concentrations of about 74% was observed, with individual changes ranging from 36-110%. Isoprene profiles exhibited pronounced concentration peaks, which were highly specific for leg movements as scored by tibial electromyography. Furthermore, relative to a linear trend, baseline isoprene concentrations decreased during the transition from the NREM to the REM phase of a complete sleep cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Fat Diet Disrupts Behavioral and Molecular Circadian Rhythms in Mice
Kohsaka, A., Laposky, A. D., Ramsey, K. M., Estrada, C., Joshu, C., Kobayashi, Y., Turek, F. W., & Bass, J. (2007) · Cell Metabolism · doi:10.1016/j.cmet.2007.09.006 · Cited by 1,528
Effects of poor and short sleep on glucose metabolism and obesity risk
Spiegel, K., Tasali, E., Leproult, R., & Van Cauter, E. (2009) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2009.23 · Cited by 857
Roles of Circadian Rhythmicity and Sleep in Human Glucose Regulation
Van Cauter, E. (1997) · Endocrine Reviews · doi:10.1210/er.18.5.716 · Cited by 608
Role of Sleep and Sleep Loss in Hormonal Release and Metabolism
Leproult, R., & Van Cauter, E. (2010) · Endocrine Development · doi:10.1159/000262524 · Cited by 602
Biochemical regulation of non-rapid-eye-movement sleep
Krueger, J. M. (2003) · Frontiers in Bioscience · doi:10.2741/1033 · Cited by 329
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationVolatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationA European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Self-citationIs breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
On-Line Analysis of Exhaled Breath: Focus Review
Bruderer, T., Gaisl, T., Gaugg, M. T., Nowak, N., Streckenbach, B., Müller, S., Moeller, A., Kohler, M., & Zenobi, R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00005 · Cited by 278
Filipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218
Self-citationAnalysis of Exhaled Breath for Disease Detection
Amann, A., Miekisch, W., Schubert, J., Buszewski, B., Ligor, T., Jezierski, T., Pleil, J., & Risby, T. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020043 · Cited by 214
Self-citationMeasuring breath acetone for monitoring fat loss: Review
Anderson, J. C. (2015) · Obesity · doi:10.1002/oby.21242 · Cited by 211
“Hourly variations in BrAce During overnight sleep, BrAce can increase more than twofold because food intake ceases (35).”
BackgroundSun, X., Shao, K., & Wang, T. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9200-6 · Cited by 211
“The ions will then reach the analyzer [96].”
BackgroundNanoscale Sensor Technologies for Disease Detection via Volatolomics
Vishinkin, R., & Haick, H. (2015) · Small · doi:10.1002/smll.201501904 · Cited by 199
Breath acetone as a potential marker in clinical practice
Ruzsányi, V., & Péter Kalapos, M. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa66d3 · Cited by 195
Digging deeper into volatile organic compounds associated with cancer
Janfaza, S., Khorsand, B., Nikkhah, M., & Zahiri, J. (2019) · Biology Methods and Protocols · doi:10.1093/biomethods/bpz014 · Cited by 176
Mass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Taking your breath away: metabolomics breathes life in to personalized medicine
Rattray, N. J. W., Hamrang, Z., Trivedi, D. K., Goodacre, R., & Fowler, S. J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.08.003 · Cited by 160
Metadata
- Authors
- King, J., Kupferthaler, A., Frauscher, B., Hackner, H., Unterkofler, K., Teschl, G., Hinterhuber, H., Amann, A., & Högl, B.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-02-28
- Volume
- 33
- Issue
- 3
- Pages
- 413-428
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2044003915
- Cited by
- 144
- References
- 5
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.