Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring report results on human volunteers in controlled environments. We have been able to obtain estimates of heart rate and respiratory rate and preliminary results on changes in oxygen saturation from double-monitored patients undergoing haemodialysis in the Oxford Kidney Unit. To achieve this, we have devised a novel method of cancelling out aliased frequency components caused by artificial light flicker, using auto-regressive (AR) modelling and pole cancellation. Secondly, we have been able to construct accurate maps of the spatial distribution of heart rate and respiratory rate information from the coefficients of the AR model. In stable sections with minimal patient motion, the mean absolute error between the camera-derived estimate of heart rate and the reference value from a pulse oximeter is similar to the mean absolute error between two pulse oximeter measurements at different sites (finger and earlobe). The activities of daily living affect the respiratory rate, but the camera-derived estimates of this parameter are at least as accurate as those derived from a thoracic expansion sensor (chest belt). During a period of obstructive sleep apnoea, we tracked changes in oxygen saturation using the ratio of normalized reflectance changes in two colour channels (red and blue), but this required calibration against the reference data from a pulse oximeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2011) · Springer eBooks · doi:10.1007/978-0-85729-932-1 · Cited by 1,819
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Eulerian video magnification for revealing subtle changes in the world
Wu, H.-Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., & Freeman, W. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185561 · Cited by 1,357
Analysis of Heart Rate Variability
SAYKRS, B. M. (1973) · Ergonomics · doi:10.1080/00140137308924479 · Cited by 946
Respiratory rate: the neglected vital sign
Cretikos, M. A., Bellomo, R., Hillman, K., Chen, J., Finfer, S., & Flabouris, A. (2008) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2008.tb01825.x · Cited by 889
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
Detecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.440 · Cited by 553
Cited by
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
“ing, such as the monitoring of heart rate [7]–[11], respiration [8], SpO2 [8], [12], blood pressure [13], neonates [14], [15], and the detection of atrial fibrillation [16] and mental”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“The green signal was found to provide the strongest plethysmographic signal among camera RGB signals [11,12].”
BackgroundDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Remote patient monitoring: a comprehensive study
Malasinghe, L. P., Ramzan, N., & Dahal, K. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-017-0598-x · Cited by 534
“A non-contact video based method is used to obtain vital signs, heart rate and respiration rate of patients undergoing haemodialysis (Tarassenko et al. 2014).”
MethodToward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613124 · Cited by 387
Self-citationBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“Heart rate and SpO2 can also be estimated from imaging-PPG signals, increasing their utility [25], [27].”
Self-citationA Novel Algorithm for Remote Photoplethysmography: Spatial Subspace Rotation
Wang, W., Stuijk, S., & de Haan, G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2508602 · Cited by 370
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring
van Gastel, M., Stuijk, S., & de Haan, G. (2016) · Scientific Reports · doi:10.1038/srep38609 · Cited by 253
A new look at the essence of the imaging photoplethysmography
Kamshilin, A. A., Nippolainen, E., Sidorov, I. S., Vasilev, P. V., Erofeev, N. P., Podolian, N. P., & Romashko, R. V. (2015) · Scientific Reports · doi:10.1038/srep10494 · Cited by 248
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
Secondary Analysis of Electronic Health Records
Data, M. C. (2016) · OAPEN (The OAPEN Foundation) · doi:10.1007/978-3-319-43742-2 · Cited by 246
Wearable technology: role in respiratory health and disease
Aliverti, A. (2017) · Breathe · doi:10.1183/20734735.008417 · Cited by 243
“Recently proposed methods for extracting respiratory rate from segments of PPG signals rely on estimating it from each modulation (the derived respiratory signals) and fusing the three estimates into a final value [27, 29, 30].”
BackgroundInfluentialVideo-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 227
“[63] proposed a novel method to cancel out the aliased frequency components caused by the”
MethodHuman Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“Furthermore, a millimeter-wave FMCW radar was implemented in [140] for vital signs monitoring of a patient located at around 1.7 m from Showing relatively low power consumption, this system may be used for long-term monitoring of patients. the radar.”
InfluentialA survey of remote optical photoplethysmographic imaging methods
McDuff, D. J., Estepp, J. R., Piasecki, A. M., & Blackford, E. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319857 · Cited by 204
“[23] presented the application of PPGi for vital sign monitoring of PR, RR, and SpO2 of hemodialysis patients in a Kidney Unit.”
MethodInfluentialThe 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Self-citationContinuous non‐contact vital sign monitoring in neonatal intensive care unit
Villarroel, M., Guazzi, A., Jorge, J., Davis, S., Watkinson, P., Green, G., Shenvi, A., McCormick, K., & Tarassenko, L. (2014) · Healthcare Technology Letters · doi:10.1049/htl.2014.0077 · Cited by 187
“Continuous non-contact vital sign monitoring in neonatal intensive care unit Mauricio Villarroel1, Alessandro Guazzi1, João Jorge1, Sara Davis2, Peter Watkinson3, Gabrielle Green2,”
BackgroundSelf-citationContactless Methods For Measuring Respiratory Rate: A Review
Massaroni, C., Nicolo, A., Sacchetti, M., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3023486 · Cited by 180
“with red, green, and blue channels - RGB) and visible light sensors have been tested to retrieve fR values from the recorded chest wall movements [24], [191]–[203].”
MethodIntroducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 160
Camera Measurement of Physiological Vital Signs
McDuff, D. (2023) · ACM Computing Surveys · doi:10.1145/3558518 · Cited by 159
“In inpatient ICU care, remote measurement can help protect patients and physicians while also creating a more comfortable experience for those receiving care, whether it be a baby [1] or an adult [147].”
BackgroundMethodInfluentialBarrera, A., Gee, C., Wood, A., Gibson, O., Bayley, D., & Geddes, J. (2020) · Evidence-Based Mental Health · doi:10.1136/ebmental-2019-300136 · Cited by 79
Nowara, E. M., McDuff, D., & Veeraraghavan, A. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00150 · Cited by 66
Non-Contact SpO2 Prediction System Based on a Digital Camera
Al-Naji, A., Khalid, G. A., Mahdi, J. F., & Chahl, J. (2021) · Applied Sciences · doi:10.3390/app11094255 · Cited by 61
Estimation of HRV and SpO2 from wrist-worn commercial sensors for clinical settings
Jarchi, D., Salvi, D., Velardo, C., Mahdi, A., Tarassenko, L., & Clifton, D. A. (2018) · 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN) · doi:10.1109/bsn.2018.8329679 · Cited by 38
“Attempts in detecting SpO2 from reflectance PPG focus on wrist worn sensors [5] and video recordings [6].”
BackgroundSelf-citationAddison, P. S., Jacquel, D., Foo, D. M. H., & Borg, U. R. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0076-1 · Cited by 24
Metadata
- Authors
- Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-03-28
- Volume
- 35
- Issue
- 5
- Pages
- 807-831
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2139293067
- Cited by
- 423
- References
- 33
- FWCI
- 18.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.