Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring report results on human volunteers in controlled environments. We have been able to obtain estimates of heart rate and respiratory rate and preliminary results on changes in oxygen saturation from double-monitored patients undergoing haemodialysis in the Oxford Kidney Unit. To achieve this, we have devised a novel method of cancelling out aliased frequency components caused by artificial light flicker, using auto-regressive (AR) modelling and pole cancellation. Secondly, we have been able to construct accurate maps of the spatial distribution of heart rate and respiratory rate information from the coefficients of the AR model. In stable sections with minimal patient motion, the mean absolute error between the camera-derived estimate of heart rate and the reference value from a pulse oximeter is similar to the mean absolute error between two pulse oximeter measurements at different sites (finger and earlobe). The activities of daily living affect the respiratory rate, but the camera-derived estimates of this parameter are at least as accurate as those derived from a thoracic expansion sensor (chest belt). During a period of obstructive sleep apnoea, we tracked changes in oxygen saturation using the ratio of normalized reflectance changes in two colour channels (red and blue), but this required calibration against the reference data from a pulse oximeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2011) · Springer eBooks · doi:10.1007/978-0-85729-932-1 · Cited by 1,819
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Eulerian video magnification for revealing subtle changes in the world
Wu, H.-Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., & Freeman, W. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185561 · Cited by 1,357
Analysis of Heart Rate Variability
SAYKRS, B. M. (1973) · Ergonomics · doi:10.1080/00140137308924479 · Cited by 946
Respiratory rate: the neglected vital sign
Cretikos, M. A., Bellomo, R., Hillman, K., Chen, J., Finfer, S., & Flabouris, A. (2008) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2008.tb01825.x · Cited by 889
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
Detecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.440 · Cited by 553
Hello! My name is... Buffy'' -- Automatic Naming of Characters in TV Video
Everingham, M. R., Sivic, J., & Zisserman, A. (2006) · Procedings of the British Machine Vision Conference 2006 · doi:10.5244/c.20.92 · Cited by 552
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
Lewandowska, M., Rumiński, J., Kocejko, T., & Nowak, J. (2011) · Cited by 420
A review of parametric modelling techniques for EEG analysis
Pardey, J., Roberts, S., & Tarassenko, L. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00024-0 · Cited by 286
Self-citationWieringa, F. P., Mastik, F., & Steen, A. F. W. V. D. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5763-2 · Cited by 284
Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Self-citation“Who are you?” - Learning person specific classifiers from video
Sivic, J., Everingham, M., & Zisserman, A. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206513 · Cited by 223
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Varun Kumar, Y. V. B., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Humphreys, K., Ward, T., & Markham, C. (2007) · Review of Scientific Instruments · doi:10.1063/1.2724789 · Cited by 217
Sun, Y. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3602852 · Cited by 214
Non-contact detection of oxygen saturation based on visible light imaging device using ambient light
Kong, L., Zhao, Y., Dong, L., Jian, Y., Jin, X., Li, B., Feng, Y., Liu, M., Liu, X., & Wu, H. (2013) · Optics Express · doi:10.1364/oe.21.017464 · Cited by 187
History of blood gas analysis. VII. Pulse oximetry
Severinghaus, J. W., & Honda, Y. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf00858362 · Cited by 179
Bousefsaf, F., Maaoui, C., & Pruski, A. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.05.010 · Cited by 161
Felber Dietrich, D., Schindler, C., Schwartz, J., Barthélémy, J.-C., Tschopp, J.-M., Roche, F., von Eckardstein, A., Brändli, O., Leuenberger, P., Gold, D. R., et al. (2006) · EP Europace · doi:10.1093/europace/eul063 · Cited by 150
Heart rate monitoring via remote photoplethysmography with motion artifacts reduction
Cennini, G., Arguel, J., Akşit, K., & van Leest, A. J. (2010) · Optics Express · doi:10.1364/oe.18.004867 · Cited by 134
Bikov, A., Lázár, Z., & Horvath, I. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/3/034001 · Cited by 127
Spectral analysis of heart rate without resampling
Moody, G. B. (2002) · Proceedings of Computers in Cardiology Conference · doi:10.1109/cic.1993.378302 · Cited by 122
Tutorial on Univariate Autoregressive Spectral Analysis
Takalo, R., Hytti, H., & Ihalainen, H. (2005) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-7089-x · Cited by 91
Agashe, G. S., Coakley, J., & Mannheimer, P. D. (2006) · Anesthesiology · doi:10.1097/00000542-200612000-00010 · Cited by 62
Nesseler, N., Frénel, J.-V., Launey, Y., Morçet, J., Mallédant, Y., & Séguin, P. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2659-0 · Cited by 44
A Comparison of Transmittance and Reflectance Pulse Oximetry During Vascular Surgery
Wax, D. B., Rubin, P., & Neustein, S. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbc446 · Cited by 38
Bay, A., André, N., Sarrazin, M., Belarouci, A., Aimez, V., Francis, L. A., & Vigneron, J. P. (2013) · Optics Express · doi:10.1364/oe.21.00a179 · Cited by 35
Yönt, G. H., Korhan, E. A., & Khorshıd, L. (2010) · Applied Nursing Research · doi:10.1016/j.apnr.2010.03.002 · Cited by 19
Cited by
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
“ing, such as the monitoring of heart rate [7]–[11], respiration [8], SpO2 [8], [12], blood pressure [13], neonates [14], [15], and the detection of atrial fibrillation [16] and mental”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“The green signal was found to provide the strongest plethysmographic signal among camera RGB signals [11,12].”
BackgroundDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Remote patient monitoring: a comprehensive study
Malasinghe, L. P., Ramzan, N., & Dahal, K. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-017-0598-x · Cited by 534
“A non-contact video based method is used to obtain vital signs, heart rate and respiration rate of patients undergoing haemodialysis (Tarassenko et al. 2014).”
MethodToward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613124 · Cited by 387
Self-citation
Metadata
- Authors
- Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-03-28
- Volume
- 35
- Issue
- 5
- Pages
- 807-831
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2139293067
- Cited by
- 423
- References
- 33
- FWCI
- 18.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.