Review on water quality sensors
The DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Abstract
Abstract Terrestrial life may be carbon-based, but most of its mass is made up of water. Access to clean water is essential to all aspects of maintaining life. Mainly due to human activity, the strain on the water resources of our planet has increased substantially, requiring action in water management and purification. Water quality sensors are needed in order to quantify the problem and verify the success of remedial actions. This review summarizes the most common chemical water quality parameters, and current developments in sensor technology available to monitor them. Particular emphasis is on technologies that lend themselves to reagent-free, low-maintenance, autonomous and continuous monitoring. Chemiresistors and other electrical sensors are discussed in particular detail, while mechanical, optical and electrochemical sensors also find mentioning. The focus here is on the physics of chemical signal transduction in sensor elements that are in direct contact with the analyte. All other sensing methods, and all other elements of sampling, sample pre-treatment as well as the collection, transmission and analysis of the data are not discussed here. Instead, the goal is to highlight the progress and remaining challenges in the development of sensor materials and designs for an audience of physicists and materials scientists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics and Chemometrics for Analytical Chemistry
Ziegel, E. R. (2004) · Technometrics · doi:10.1198/tech.2004.s248 · Cited by 4,416
Official Journal of the European Communities
(1984) · Analytical Proceedings · doi:10.1039/ap9842100196 · Cited by 4,027
Statistics and Chemometrics for Analytical Chemistry
Miller, J. N., & Miller, J. C. (2005) · Cited by 3,783
Extreme Oxygen Sensitivity of Electronic Properties of Carbon Nanotubes
Collins, P. G., Bradley, K., Ishigami, M., & Zettl, A. (2000) · Science · doi:10.1126/science.287.5459.1801 · Cited by 2,974 · cited 1×
“Molecular oxygen has also been shown to dope nanocarbon materials [49, 50], which could be used for the design of chemiresistive sensors, again with the challenge of imparting selectivity.”
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859 · cited 1×
“Some reviews discuss nitrate and nitrite sensors as well [113, 114, 115].”
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,627
Li, H., Yin, Z., He, Q., Li, H., Huang, X., Lu, G., Fam, D. W. H., Tok, A. I. Y., Zhang, Q., & Zhang, H. (2012) · Small · doi:10.1002/smll.201101016 · Cited by 1,536
Sensing Behavior of Atomically Thin-Layered MoS2 Transistors
Late, D. J., Huang, Y.-K., Liu, B., Acharya, J., Shirodkar, S. N., Luo, J., Yan, A., Charles, D., Waghmare, U. V., Dravid, V. P., et al. (2013) · ACS Nano · doi:10.1021/nn400026u · Cited by 1,374
Evidence for charge transfer in doped carbon nanotube bundles from Raman scattering
Rao, A. M., Eklund, P. C., Bandow, S., Thess, A., & Smalley, R. E. (1997) · Nature · doi:10.1038/40827 · Cited by 1,367
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
Human development report, 2006: beyond scarcity: power, poverty and the global water crisis
(2007) · Choice Reviews Online · doi:10.5860/choice.44-6944 · Cited by 1,192
Chemical Vapor Sensing with Monolayer MoS2
Perkins, F. K., Friedman, A. L., Cobas, E., Campbell, P. M., Jernigan, G. G., & Jonker, B. T. (2013) · Nano Letters · doi:10.1021/nl3043079 · Cited by 1,138
Jung, H. S., Kwon, P. S., Lee, J. W., Kim, J. I., Hong, C. S., Kim, J. W., Yan, S., Lee, J. Y., Lee, J. H., Joo, T., et al. (2009) · Journal of the American Chemical Society · doi:10.1021/ja808611d · Cited by 1,058
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Fabrication of Flexible MoS2 Thin‐Film Transistor Arrays for Practical Gas‐Sensing Applications
He, Q., Zeng, Z., Yin, Z., Li, H., Wu, S., Huang, X., & Zhang, H. (2012) · Small · doi:10.1002/smll.201201224 · Cited by 925
Conducting polymers in chemical sensors and arrays
Lange, U., Roznyatovskaya, N. V., & Mirsky, V. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.02.068 · Cited by 911 · cited 1×
“Due to the strong interest in measuring disinfectant concentrations in water, the topic is covered by many reviews [69, 70, 71, 72, 73].”
Detection and determination of nitrate and nitrite: a review
Moorcroft, M. (2001) · Talanta · doi:10.1016/s0039-9140(01)00323-x · Cited by 873 · cited 1×
“Some reviews discuss nitrate and nitrite sensors as well [113, 114, 115].”
Organic field-effect transistor sensors: a tutorial review
Torsi, L., Magliulo, M., Manoli, K., & Palazzo, G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60127g · Cited by 825
Liu, B., Chen, L., Liu, G., Abbas, A. N., Fathi, M., & Zhou, C. (2014) · ACS Nano · doi:10.1021/nn5015215 · Cited by 728
Solution-Gated Epitaxial Graphene as pH Sensor
Ang, P. K., Chen, W., Wee, A. T. S., & Loh, K. P. (2008) · Journal of the American Chemical Society · doi:10.1021/ja805090z · Cited by 723 · cited 1×
“12 electrical (SGFET) [38] solution-gate field effect transistor”
Gas sensors using carbon nanomaterials: A review
Llobet, E. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.11.014 · Cited by 692
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac800473b · Cited by 571
Wencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Identifying the Mechanism of Biosensing with Carbon Nanotube Transistors
Heller, I., Janssens, A. M., Männik, J., Minot, E. D., Lemay, S. G., & Dekker, C. (2008) · Nano Letters · doi:10.1021/nl072996i · Cited by 490
Global phosphorus retention by river damming
Maavara, T., Parsons, C. T., Ridenour, C., Stojanovic, S., Dürr, H. H., Powley, H. R., & Van Cappellen, P. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1511797112 · Cited by 485 · cited 1×
“Phosphorous - in the form of phosphate - is an important nutrient and as such of much concern in surface waters, as high concentrations can cause excessive growth of phytoplankton (“eutrophication”) [128, 129].”
Organic field-effect transistor-based gas sensors
Zhang, C., Chen, P., & Hu, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00326h · Cited by 468
Two-Dimensional Materials for Sensing: Graphene and Beyond
Varghese, S., Varghese, S., Swaminathan, S., Singh, K., & Mittal, V. (2015) · Electronics · doi:10.3390/electronics4030651 · Cited by 466
Electrochemical Sensors Based on Organic Conjugated Polymers
Rahman, M. A., Kumar, P., Park, D.-S., & Shim, Y.-B. (2008) · Sensors · doi:10.3390/s8010118 · Cited by 464
Yu, C., Li, X., Zeng, F., Zheng, F., & Wu, S. (2013) · Chem. Commun. · doi:10.1039/c2cc37329g · Cited by 455 · cited 1×
“H2S > 10 nM optical (fluorescence) [143]”
Probes and Polymers for Optical Sensing of Oxygen
Amao, Y. (2003) · Microchimica Acta · doi:10.1007/s00604-003-0037-x · Cited by 444 · cited 1×
“Furthermore, many metallo-porphyrins form strong complexed with molecular oxygen, which can be used for its detection [51, 52, 53].”
Single-layer MoSe2 based NH3 gas sensor
Late, D. J., Doneux, T., & Bougouma, M. (2014) · Applied Physics Letters · doi:10.1063/1.4903358 · Cited by 407
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L.-C., Ota, H., Wu, E., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 391 · cited 1×
“300 ppb anodic stripping voltammetry [159]”
Water Quality: An Introduction
Boyd, C. E. (2015) · doi:10.1007/978-3-319-17446-4 · Cited by 361
Water-stable organic transistors and their application in chemical and biological sensors
Roberts, M. E., Mannsfeld, S. C. B., Queraltó, N., Reese, C., Locklin, J., Knoll, W., & Bao, Z. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0802105105 · Cited by 358
An Amperometric Microsensor for the Determination of H2S in Aquatic Environments
Jeroschewski, P., Steuckart, C., & Kühl, M. (1996) · Analytical Chemistry · doi:10.1021/ac960091b · Cited by 352 · cited 1×
“3400 ppb electrochemical (amperometric) [142] dependent on pH, response time < 100 ms”
Tang, Y., Su, Y., Yang, N., Zhang, L., & Lv, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5005162 · Cited by 345
Electrochemistry at carbon nanotubes: perspective and issues
Dumitrescu, I., Unwin, P. R., & Macpherson, J. V. (2009) · Chemical Communications · doi:10.1039/b909734a · Cited by 325
Ruecha, N., Rodthongkum, N., Cate, D. M., Volckens, J., Chailapakul, O., & Henry, C. S. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.064 · Cited by 317 · cited 2×
“1 ppb anodic stripping voltammetry [160]”
Koo, Y.-E. L., Cao, Y., Kopelman, R., Koo, S. M., Brasuel, M., & Philbert, M. A. (2004) · Analytical Chemistry · doi:10.1021/ac035493f · Cited by 316
Fermi Level Engineering of Single-Walled Carbon Nanotubes by AuCl3 Doping
Kim, K. K., Bae, J. J., Park, H. K., Kim, S. M., Geng, H.-Z., Park, K. A., Shin, H.-J., Yoon, S.-M., Benayad, A., Choi, J.-Y., et al. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8038689 · Cited by 282
Potentiometric Ion Sensors Based on Conducting Polymers
Bobacka, J., Ivaska, A., & Lewenstam, A. (2003) · Electroanalysis · doi:10.1002/elan.200390042 · Cited by 277
Sensing and analysis of soluble phosphates in environmental samples: A review
Warwick, C., Guerreiro, A., & Soares, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.012 · Cited by 272 · cited 1×
“There are also some reviews giving an overview of electrochemical (potentiometric, voltammetric, amperometric) [130, 131, 132] and optical methods [131, 132].”
Recent development and applications of optical and fiber-optic pH sensors
Lin, J. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00034-0 · Cited by 271 · cited 1×
“Some reviews on the topic are available, covering electrochemical and optical instrumentation [14, 15, 16], but Table 2 also gives an overview over some recent sensor developments, especially based on electrical detection (chemiresistive or FET-based).”
Tailoring of Sol−Gel Films for Optical Sensing of Oxygen in Gas and Aqueous Phase
McDonagh, C., MacCraith, B. D., & McEvoy, A. K. (1998) · Analytical Chemistry · doi:10.1021/ac970461b · Cited by 266 · cited 1×
“40 ppm optical (fluorescence) [60] 5 ppb limit of detection claimed”
Conductance-Controlled Point Functionalization of Single-Walled Carbon Nanotubes
Goldsmith, B. R., Coroneus, J. G., Khalap, V. R., Kane, A. A., Weiss, G. A., & Collins, P. G. (2007) · Science · doi:10.1126/science.1135303 · Cited by 247 · cited 1×
“As impressive as feats of single molecule sensing are [202], and as much effort may be put into lowering detection limits, ultimately the reliability of a sensor design is a deciding factor in practical deployment.”
Rapid and direct determination of wastewater BOD values using a fluorescence technique
Reynolds, D. M., & Ahmad, S. R. (1997) · Water Research · doi:10.1016/s0043-1354(97)00015-8 · Cited by 238 · cited 2×
“6 In addition to DO, chemical oxygen demand (COD) and biochemical oxygen demand (BOD) [55] are also important parameters.”
Stoddard, J. L., Van Sickle, J., Herlihy, A. T., Brahney, J., Paulsen, S., Peck, D. V., Mitchell, R., & Pollard, A. I. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.5b05950 · Cited by 235
Electroactive polymers for sensing
Wang, T., Farajollahi, M., Choi, Y. S., Lin, I.-T., Marshall, J. E., Thompson, N. M., Kar-Narayan, S., Madden, J. D. W., & Smoukov, S. K. (2016) · Interface Focus · doi:10.1098/rsfs.2016.0026 · Cited by 220
Contribution of traditional knowledge to ecological restoration: Practices and applications
Uprety, Y., Asselin, H., Bergeron, Y., Doyon, F., & Boucher, J.-F. (2012) · Écoscience · doi:10.2980/19-3-3530 · Cited by 205 · cited 1×
“The central importance of water to life has been recognised in all civilisations, well predating our current western knowledge base [1, 2].”
InfluentialMethods for the photometric determination of reactive bromine and chlorine species with ABTS
Pinkernell, U. (2000) · Water Research · doi:10.1016/s0043-1354(00)00216-5 · Cited by 201 · cited 1×
“1 μM colorimetric [84] ABTS, limited selectivity for free chlorine (determined by difference)”
Carbon Nanotube‐Based Chemical Sensors
Meyyappan, M. (2016) · Small · doi:10.1002/smll.201502555 · Cited by 199
Qin, Y., Kwon, H.-J., Howlader, M. M. R., & Deen, M. J. (2015) · RSC Advances · doi:10.1039/c5ra11291e · Cited by 196 · cited 1×
“Some reviews on the topic are available, covering electrochemical and optical instrumentation [14, 15, 16], but Table 2 also gives an overview over some recent sensor developments, especially based on electrical detection (chemiresistive or FET-based).”
Charge Transfer Induced Polarity Switching in Carbon Nanotube Transistors
Klinke, C., Chen, J., Afzali, A., & Avouris, P. (2005) · Nano Letters · doi:10.1021/nl048055c · Cited by 190
Rahimi, R., Ochoa, M., Tamayol, A., Khalili, S., Khademhosseini, A., & Ziaie, B. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b16228 · Cited by 189
Continuous flow determination of free chlorine in water
Aoki, T., & Munemori, M. (1983) · Analytical Chemistry · doi:10.1021/ac00253a010 · Cited by 172 · cited 1×
“10 mM UV absorption [77] reagentless (290 nm abs.”
WO3Nanoparticle-Based Conformable pH Sensor
Santos, L., Neto, J. P., Crespo, A., Nunes, D., Costa, N., Fonseca, I. M., Barquinha, P., Pereira, L., Silva, J., Martins, R., et al. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501724h · Cited by 169 · cited 1×
“9 electrochemical (potentiometric) [21] WO3 3.”
Online Drinking Water Quality Monitoring: Review on Available and Emerging Technologies
Banna, M. H., Imran, S. A., Francisque, A., Najjaran, H., Sadiq, R., Rodríguez, M. J., & Hoorfar, M. (2013) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2013.781936 · Cited by 168 · cited 1×
“Due to the strong interest in measuring disinfectant concentrations in water, the topic is covered by many reviews [69, 70, 71, 72, 73].”
Determination of Lead with a Copper-Based Electrochemical Sensor
Kang, W., Pei, X., Rusinek, C. A., Bange, A., Haynes, E. N., Heineman, W. R., & Papautsky, I. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03894 · Cited by 158
Interfacial Charge Transfer between Phenyl-Capped Aniline Tetramer Films and Iron Oxide Surfaces
Mohtasebi, A., Chowdhury, T., Hsu, L. H. H., Biesinger, M. C., & Kruse, P. (2016) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b09950 · Cited by 155
Self-citationDaiber, E. J., DeMarini, D. M., Ravuri, S. A., Liberatore, H. K., Cuthbertson, A. A., Thompson-Klemish, A., Byer, J. D., Schmid, J. E., Afifi, M. Z., Blatchley, E. R., et al. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b00808 · Cited by 154 · cited 1×
“Due to the strong interest in measuring disinfectant concentrations in water, the topic is covered by many reviews [69, 70, 71, 72, 73].”
Chemically assembled monolayers of fluorophores as chemical sensing materials
Ding, L., & Fang, Y. (2010) · Chemical Society Reviews · doi:10.1039/c003028g · Cited by 153 · cited 1×
“various species optical (fluorescence) [200] review”
Microfabricated conductimetric pH sensor
Sheppard, N. F., Lesho, M. J., McNally, P., & Francomacaro, A. S. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(94)01542-p · Cited by 148
Raman based pH measurements with polyaniline
Lindfors, T., & Ivaska, A. U. (2005) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2005.03.042 · Cited by 148
Porphyrin-Functionalized Single-Walled Carbon Nanotube Chemiresistive Sensor Arrays for VOCs
Shirsat, M. D., Sarkar, T., Kakoullis, J., Myung, N. V., Konnanath, B., Spanias, A., & Mulchandani, A. (2012) · The Journal of Physical Chemistry C · doi:10.1021/jp210582t · Cited by 145
Simultaneous Detection of Heavy Metals by Anodic Stripping Voltammetry Using Carbon Nanotube Thread
Zhao, D., Guo, X., Wang, T., Alvarez, N. T., Shanov, V. N., & Heineman, W. R. (2014) · Electroanalysis · doi:10.1002/elan.201300511 · Cited by 134 · cited 1×
“27 nM anodic stripping voltammetry [158]”
Carbon Nanotube Chemiresistor for Wireless pH Sensing
Gou, P., Kraut, N. D., Feigel, I. M., Bai, H., Morgan, G. J., Chen, Y., Tang, Y., Bocan, K. N., Stachel, J. R., Berger, L., et al. (2014) · Scientific Reports · doi:10.1038/srep04468 · Cited by 132
Flow analysis techniques for phosphorus: an overview
Estela, J. M., & Cerdà, V. (2005) · Talanta · doi:10.1016/j.talanta.2004.12.029 · Cited by 126
Determination of inorganic phosphate by electroanalytical methods: A review
Berchmans, S., Issa, T. B., & Singh, P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.060 · Cited by 125 · cited 1×
“There are also some reviews giving an overview of electrochemical (potentiometric, voltammetric, amperometric) [130, 131, 132] and optical methods [131, 132].”
The Determination of Free and Combined Chlorine in Water by the Use of Diethyl‐p‐phenylene Diamine
Palin, A. T. (1957) · American Water Works Association · doi:10.1002/j.1551-8833.1957.tb16870.x · Cited by 122
Mixed Potential Response Mechanism of Cobalt Electrodes toward Inorganic Phosphate
Meruva, R. K., & Meyerhoff, M. E. (1996) · Analytical Chemistry · doi:10.1021/ac951086v · Cited by 120 · cited 1×
“10 mM electrochemical (potentiometric) [138] cobalt electrodes”
Vellingiri, K., Deep, A., Kim, K., Boukhvalov, D. W., Kumar, P., & Yao, Q. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.017 · Cited by 113
Quantitative surface stress measurements using a microcantilever
Godin, M., Tabard‐Cossa, V., Grütter, P., & Williams, P. (2001) · Applied Physics Letters · doi:10.1063/1.1387262 · Cited by 113 · cited 1×
“Swelling strain of a porous thin film or surface layer can be detected mechanically, for example through bending of a micro-cantilever [207].”
Metal to Insulator Transition in Films of Molecularly Linked Gold Nanoparticles
Zabet-Khosousi, A., Trudeau, P.-E., Suganuma, Y., Dhirani, A.-A., & Statt, B. W. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.156403 · Cited by 111
The Institute of Chemistry of Great Britain and Ireland. Journal and Proceedings. Part VI: 1941
(1941) · Journal of the Royal Institute of Chemistry · doi:10.1039/jg9416500301 · Cited by 106
Kim, T. Y., & Yang, S. H. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.02.004 · Cited by 105 · cited 1×
“6 electrochemical (potentiometric) [20]”
Immunosensing of Atrazine with Antibody-Functionalized Cu-MOF Conducting Thin Films
Bhardwaj, S. K., Bhardwaj, N., Mohanta, G. C., Kumar, P., Sharma, A. L., Kim, K., & Deep, A. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b07692 · Cited by 103 · cited 1×
“01 nM electrical (chemiresistor) [187] good selectivity against other pesticides atrazine 0.”
A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate
Zou, Z., Han, J., Jang, A., Bishop, P. L., & Ahn, C. H. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.004 · Cited by 103 · cited 1×
“10 mM electrochemical (potentiometric) [141] cobalt microelectrodes (disposable)”
pH sensing properties of graphene solution-gated field-effect transistors
Mailly-Giacchetti, B., Hsu, A., Wang, H., et al. (2013) · Journal of Applied Physics · doi:10.1063/1.4819219 · Cited by 101
Kumar, D. R., Kesavan, S., Nguyen, T. T., Hwang, J., Lamiel, C., & Shim, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.025 · Cited by 101
Phosphate determination in seawater: Toward an autonomous electrochemical method
Jońca, J., Fernández, V. L., Thouron, D., Paulmier, A., Graco, M., & Garcon, V. C. (2011) · Talanta · doi:10.1016/j.talanta.2011.09.056 · Cited by 101 · cited 1×
“100 μM electrochemical (amperometric) [139] anodic oxidation of molybdenum”
Electrochemical detection of free chlorine at inkjet printed silver electrodes
Jović, M., Cortés‐Salazar, F., Lesch, A. S., Amstutz, V., Bi, H., & Girault, H. H. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2015.08.024 · Cited by 99
Udhayakumari, D., Velmathi, S., Sung, Y.-M., & Wu, S. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.03.063 · Cited by 96 · cited 1×
“15 nM optical (fluorescence) [157] commercially available probe molecules Cu > 0.”
Technique for rapid detection of phthalates in water and beverages
Zia, A. I., Rahman, M. S. A., Mukhopadhyay, S. C., Yu, P., Al-Bahadly, I. H., Gooneratne, C. P., Kosel, J., & Liao, T.-S. (2013) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2012.12.024 · Cited by 96
Determination of chlorine in water by luminol chemiluminescence
Marino, D. F., & Ingle, J. D. (1981) · Analytical Chemistry · doi:10.1021/ac00226a015 · Cited by 96
Shan, Z., Lü, M., Wang, L., MacDonald, B., MacInnis, J., Mkandawire, M., Zhang, X., & Oakes, K. D. (2015) · Chemical Communications · doi:10.1039/c5cc07446k · Cited by 94
Prakash, S., Chakrabarty, T., Singh, A. K., & Shahi, V. K. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.025 · Cited by 92 · cited 1×
“100 ppb anodic stripping voltammetry [172]”
Moonoosawmy, K. R., & Kruse, P. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8036788 · Cited by 91
Self-citationA fast-responding fluorescent turn-on sensor for sensitive and selective detection of sulfite anions
Yu, C., Luo, M., Zeng, F., & Wu, S. (2012) · Analytical Methods · doi:10.1039/c2ay25496d · Cited by 88 · cited 1×
“SO3 > 10 nM optical (fluorescence) [146] SO3 1.”
Guselnikova, O., Постников, П. С., Erzina, M., Kalachyova, Y., Švorčík, V., & Lyutakov, O. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.018 · Cited by 87 · cited 3×
“Raman spectroscopy, surface-enhanced Raman spectroscopy (SERS), and surface plasmon resonance (SPR) are all promising techniques that are well-established in the laboratory and that are actively developed for sensing applications in the field.”
Maity, A., Sui, X., Tarman, C. R., Pu, H., Chang, J., Zhou, G., Ren, R., Mao, S., & Chen, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00496 · Cited by 85
All-solid-state reference electrodes based on conducting polymers
Kisiel, A., Marcisz, H., Michalska, A., & Maksymiuk, K. (2005) · The Analyst · doi:10.1039/b510868c · Cited by 84
Thirty Years of CHEMFETs – A Personal View
Janata, J. (2004) · Electroanalysis · doi:10.1002/elan.200403070 · Cited by 80
A New Salt Bridge Based on the Hydrophobic Room-Temperature Molten Salt
Kakiuchi, T., & Yoshimatsu, T. (2006) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.79.1017 · Cited by 78
A Drinking Water Sensor for Lead and Other Heavy Metals
Lin, W.-C., Li, Z., & Burns, M. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00843 · Cited by 77 · cited 1×
“Pb > 15 ppb electrochemical [169] emphasizes simple design Pb n/a optical (colorimetric) [170] after extraction to non-aqueous phase Pb > 1.”
Spatiotemporal trend analysis of recent river water quality conditions in Japan
Luo, P., He, B., Takara, K., Razafindrabe, B. H. N., Nover, D. M., & Yamashiki, Y. (2011) · Journal of Environmental Monitoring · doi:10.1039/c1em10339c · Cited by 76
Sun, W., Wang, Y., Lu, Y., Hu, A., Shi, F., & Sun, Z. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.07.032 · Cited by 76
Liu, C., Shi, C., Li, H., Du, W., Li, Z., Wei, L., & Yu, M. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.131 · Cited by 75
Rigante, S., Scarbolo, P., Wipf, M., Stoop, R. L., Bedner, K., Buitrago, E., Bazigos, A., Bouvet, D., Calame, M., Schönenberger, C., et al. (2015) · ACS Nano · doi:10.1021/nn5064216 · Cited by 73
Ionic Liquid‐Based, Liquid‐Junction‐Free Reference Electrode
Cicmil, D., Anastasova, S., Kavanagh, A., Diamond, D., Mattinen, U., Bobacka, J., Lewenstam, A., & Radu, A. (2011) · Electroanalysis · doi:10.1002/elan.201100137 · Cited by 73
Inkjet-printed bifunctional carbon nanotubes for pH sensing
Qin, Y., Kwon, H.-J., Subrahmanyam, A. V., Howlader, M. M. R., Selvaganapathy, P. R., Adronov, A., & Deen, M. J. (2016) · Materials Letters · doi:10.1016/j.matlet.2016.04.048 · Cited by 72 · cited 1×
“11 electrochemical (potentiometric) [22] graphene”
Solid State Sensor for Simultaneous Measurement of Total Alkalinity and pH of Seawater
Briggs, E. M., Sandoval, S., Erten, A. C., Takeshita, Y., Kummel, A. C., & Martz, T. R. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00305 · Cited by 69 · cited 3×
“8 Electrical (ISFET) [34] Ta2O5 n/a Electrical (ISFET) [13] pH and alkalinity (2200.”
Muñoz, J., Céspedes, F., & Baeza, M. (2015) · Microchemical Journal · doi:10.1016/j.microc.2015.05.001 · Cited by 66
Factors that led to the Walkerton tragedy
Salvadori, M. I., Sontrop, J. M., Garg, A. X., MOIST, L. M., Suri, R. S., & Clark, W. F. (2009) · Kidney International · doi:10.1038/ki.2008.616 · Cited by 63 · cited 1×
“Maintaining legislated or recommended limits is challenging [9].”
Acha, V., Meurens, M., Naveau, H., & Agathos, S. N. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000605)68:5<473::aid-bit1>3.0.co;2-8 · Cited by 63 · cited 1×
“trichloroethylene, tetrachloroethylene, carbon tetrachloride > 2 ppm optical (infrared absorption) [192] selective diffusion into hydrophobic polymer improves detection limit”
Salazar, P., Martín, M. E., González–Mora, J. L., & González-Elipe, A. R. (2015) · Talanta · doi:10.1016/j.talanta.2015.08.072 · Cited by 62 · cited 1×
“3 ppm amperometric [107] Prussian Blue & flow injection analysis Free Cl 10.”
Miró, M. (2003) · Talanta · doi:10.1016/s0039-9140(03)00172-3 · Cited by 61 · cited 1×
“Some reviews discuss nitrate and nitrite sensors as well [113, 114, 115].”
Salazar, P., Martín, M. E., García-García, F. J., González–Mora, J. L., & González-Elipe, A. R. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.02.092 · Cited by 60
Zhang, L., Huang, X., Cao, Y., Xin, Y., & Ding, L. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00634 · Cited by 58 · cited 2×
“17 Ni, Hg, Al, Pb, Ba, Cr μM range optical (fluorescence) [163] selectivity by principle component analysis”
pH-sensing characteristics of multi-walled carbon nanotube sheet
Jung, D., Han, M.-E., & Lee, G. S. (2013) · Materials Letters · doi:10.1016/j.matlet.2013.10.095 · Cited by 56 · cited 1×
“10 electrical (chemiresistive) [30] resistive film: Ni @ CNT”
Selective Sensing of Sulfate in Aqueous Solution Using a Fluorescent Bis(cyclopeptide)
Reyheller, C., & Kubik, S. W. (2007) · Organic Letters · doi:10.1021/ol702386e · Cited by 55 · cited 1×
“120 μM optical (fluorescence) [149] in 1:1 water:methanol SO4 60 nM .”
Methods for the determination of anionic surfactants
Bazeľ, Y., Antal, I. P., Lavra, V. M., & Кормош, Ж. (2014) · Journal of Analytical Chemistry · doi:10.1134/s1061934814010043 · Cited by 55
Chou, J.-C., & Chen, C. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2008.2012221 · Cited by 54
Chemically Conjugated Carbon Nanotubes and Graphene for Carrier Modulation
Kim, K. K., Kim, S. M., & Lee, Y. H. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00441 · Cited by 52 · cited 1×
“Various nanomaterials have thus been fashioned into percolation network film geometries for use in electrical transduction [204, 205, 206].”
Fabrication of carbon nanotube-based pH sensor for paper-based microfluidics
Lei, K. F., Lee, K.-F., & Yang, S.-I. (2012) · Microelectronic Engineering · doi:10.1016/j.mee.2012.07.113 · Cited by 50 · cited 1×
“9 Electrical (chemiresistive) [29] Resistive film: CNT”
Redox-Induced Surface Stress of Polypyrrole-Based Actuators
Tabard‐Cossa, V., Godin, M., Grütter, P., Burgess, I. J., & Lennox, R. B. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp052630z · Cited by 48
Development of hard water sensor using fluorescence resonance energy transfer
Dey, D., Bhattacharjee, D., Chakraborty, S., & Hussain, S. A. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.04.077 · Cited by 47
Cause and Consequence of Carbon Nanotube Doping in Water and Aqueous Media
Moonoosawmy, K. R., & Kruse, P. (2010) · Journal of the American Chemical Society · doi:10.1021/ja906820n · Cited by 47 · cited 1×
“Molecular oxygen has also been shown to dope nanocarbon materials [49, 50], which could be used for the design of chemiresistive sensors, again with the challenge of imparting selectivity.”
Self-citationHsu, L. H. H., Selvaganapathy, P. R., Brash, J. L., Fang, Q., Xu, C., Deen, M. J., & Chen, H. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2332513 · Cited by 46 · cited 1×
“7 ppm electrochemical (amperometric) [56]”
Gong, J., Sarkar, T., Badhulika, S., & Mulchandani, A. (2013) · Applied Physics Letters · doi:10.1063/1.4773569 · Cited by 45
Phosphate-selective fluorescent sensing microspheres based on uranyl salophene ionophores
Wyglądacz, K., Qin, Y., Wróblewski, W., et al. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.02.069 · Cited by 42 · cited 1×
“5 mM optical (fluorescence) [140] uranyl salophene ionophores”
Wei, L., Lu, D., Wang, J., Wei, H., Zhao, J., Geng, H., & Zhang, Y. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.09.017 · Cited by 40 · cited 1×
“01 ppb electrical (chemiresistive) [199]”
Yang, Q., Yu, A. J., Simonton, J. L., Yang, G., Dohrmann, Y., Kang, Z., Li, Y., Mo, J., & Zhang, F. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta05094a · Cited by 37
On-wafer fabricated free-chlorine sensor with ppb detection limit for drinking-water monitoring
van den Berg, A., Grisel, A., Verney-Norberg, E., van der Schoot, B. H., Koudelka‐Hep, M., & de Rooij, N. F. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)85410-c · Cited by 37
Organic-based sensor for chemical detection in aqueous solution
Caboni, A., Orgiu, E., Scavetta, E., Barbaro, M., & Bonfiglio, A. (2009) · Applied Physics Letters · doi:10.1063/1.3232252 · Cited by 35
Mohtasebi, A., Broomfield, A. D., Chowdhury, T., Selvaganapathy, P. R., & Kruse, P. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b03968 · Cited by 34 · cited 1×
“60 ppm chemiresistive [110] substrate: pencil line”
Self-citationSun, X., Odyniec, M. L., Sedgwick, A. C., Lacina, K., Xu, S., Qiang, T., Bull, S. D., Marken, F., & James, T. D. (2017) · Organic Chemistry Frontiers · doi:10.1039/c6qo00448b · Cited by 31 · cited 1×
“500 μM Colorimetric; fluorometric [111] J.”
Statistical analysis and estimation of annual suspended sediments of major rivers in Japan
Luo, P., He, B., Chaffe, P. L. B., Nover, D. M., Takara, K., & Zainol, M. R. R. M. A. (2013) · Environmental Science Processes & Impacts · doi:10.1039/c3em30777h · Cited by 29
A highly selective and sensitive fluorescence “turn-on” fluoride ion sensor
Lin, Q., Yang, Q., Sun, B., Lou, J., Wei, T., & Zhang, Y. (2015) · RSC Advances · doi:10.1039/c4ra09624j · Cited by 28
Akbari, E., Arora, V., Enzevaee, A., Ahmadi, M., Saeidmanesh, M., Khaledian, M., Karimi, H., & Yusof, R. (2014) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.5.85 · Cited by 25
An optical sensor for the detection of nitrate
Lumpp, R., Reichert, J., & Ache, H. J. (1992) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(92)80346-y · Cited by 22 · cited 1×
“20 ppm Optical (colorimetric) [115] NO3 25 μM .”
Specificity of the DPD and Amperometric Titration Methods for Free Available Chlorine: A Review
Jensen, J. N., & Johnson, J. D. (1989) · American Water Works Association · doi:10.1002/j.1551-8833.1989.tb06894.x · Cited by 21 · cited 1×
“Due to the strong interest in measuring disinfectant concentrations in water, the topic is covered by many reviews [69, 70, 71, 72, 73].”
Detection of nitrite and nitrate ions in water by graphene oxide as a potential fluorescence sensor
Tang, I. H., Sundari, R., Lintang, H. O., & Yuliati, L. (2016) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/107/1/012027 · Cited by 21
Disordered Nanomaterials for Chemielectric Vapor Sensing: A Review
Snow, A. W., Perkins, F. K., Ancona, M. G., Robinson, J. T., Snow, E. S., & Foos, E. E. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2364677 · Cited by 20 · cited 1×
“Hence the merits of a percolation network film geometry have been argued for sensor design [203].”
Fakih, I., Sabri, S., Mahvash, F., Nannini, M., Siaj, M., & Szkopek, T. (2014) · Applied Physics Letters · doi:10.1063/1.4894078 · Cited by 18 · cited 2×
“8 electrical (ISFET) [34] Ta2O5 n/a electrical (ISFET) [13] pH & alkalinity (2200.”
Chemical Gating of a Synthetic Tube-in-a-Tube Semiconductor
Ng, A. L., Chen, C., Kwon, H., Peng, Z., Lee, C. S., & Wang, Y. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12111 · Cited by 18
Micro-sized pH sensors based on patterned Pd structures using an electrolysis method
Lee, Y. T., Lee, E., Lee, J. M., & Lee, W. (2009) · Current Applied Physics · doi:10.1016/j.cap.2009.06.022 · Cited by 9 · cited 1×
“10 electrical (chemiresistive) [28] resistive film: Pd”
Microband Sensor for As(III) Analysis: Reduced Matrix Interference
Dudeney, R., Newman, J. D., Davis, F., Setford, S. J., & Tothill, I. E. (2017) · Electroanalysis · doi:10.1002/elan.201700242 · Cited by 4 · cited 1×
“12 ppb anodic stripping voltammetry [171] contains a nice overview of electrochemical As sensors As 10.”
Zepik (2001) · doi:10.1002/1521-3773(20010105)40:1 · cited 1×
“F qualitative optical (colorimetric) [153] various anions (F, Cl, Br, H2PO4 , AcO, BzO, CN, NO3, SCN) F > 0.”
Metadata
- Authors
- Kruse, P.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2018-04-26
- Volume
- 51
- Issue
- 20
- Pages
- 203002
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2801638617
- Cited by
- 164
- References
- 138
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.