Noninvasive monitoring of blood glucose concentration in diabetic patients with optical coherence tomography
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract Optical coherence tomography (OCT) has been used to noninvasively monitor the blood glucose concentration (BGC) in healthy subjects with good accuracy and acceptable specificity. Based on this, the paper further considered the possibility of OCT in noninvasive monitoring BGC in diabetic patients. The OCT signal slope (OCTSS) changed with variation of BGC. The correlation coefficient R between BGC and OCTSS in diabetic patients was 0.91; while the correlation coefficient R in healthy volunteers was 0.78. Thus, a better linear dependence of OCTSS on BGC in diabetic patients was presented in the experiment. The results showed that the capability and accuracy of OCT in noninvasive monitoring BGC of diabetic patients, and the noninvasive monitoring BGC in diabetic patients may be better than the monitoring in the healthy subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011
Glycemic durability of rosiglitazone, metformin, or glyburide monotherapy
Kahn, S. E., Haffner, S. M., Heise, M. A., Herman, W. H., Holman, R. R., Jones, N. P., Kravitz, B. G., Lachin, J. M., O'Neill, M. C., Zinman, B., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa066224 · Cited by 2,962
Research works printed but not linked: 35
- de Cristina, 2008, Oral manifestations of diabetes mellitus in complete denture wearers, J. Prosthet. Dent., 99, 60, 10.1016/S0022-3913(08)60010-4 · DOI
- Lamster, 2008, The relationship between oral health and diabetes mellitus, J. Am. Dent. Assoc., 139, 19, 10.14219/jada.archive.2008.0051 · DOI
- Association, 2000, Tests of glycemia in diabetes, Diabetes Care, 18, 1761, 10.2337/diacare.27.2007.S91 · DOI · Paper page
- Morley, 2008, Diabetes and aging: epidemiologic overview, Clin. Geriatr. Med., 24, 395, 10.1016/j.cger.2008.03.005 · DOI · Paper page
- Girardin, 2009, Continuous glucose monitoring: a review of biochemical perspectives and clinical use in type 1 diabetes, Clin. Biochem., 42, 136, 10.1016/j.clinbiochem.2008.09.112 · DOI
- Larin, 2004, Optical coherence tomography and noninvasive blood glucose monitoring: a review, Proc. SPIE, 5, 285, 10.1117/12.578965 · DOI
- Cameron, 1997, Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach, IEEE Trans. Biomed. Eng., 44, 1221, 10.1109/10.649993 · DOI · Paper page
- Cameron, 1996, Polarimetric glucose sensing in aqueous humor utilizing digital closed-loop control, vol 1, 204, 10.1109/IEMBS.1996.656917 · doi:10.1109/iembs.1996.656917
- Coté, 1992, Noninvasive optical polarimetric glucose sensing using a true phase measurement technique, IEEE Trans. Biomed. Eng., 39, 752, 10.1109/10.142650 · DOI · Paper page
- Malik, 2010, Real-time, closed-loop dual-wavelength optical polarimetry for glucose monitoring, J. Biomed. Opt., 15, 10.1117/1.3290819 · doi:10.1117/1.3290819
- Saptari, 2004, Nir measurements of glucose in synthetic biological solutions using high-throughput angle-tuned filter spectrometer, Proc. SPIE, 5325, 1, 10.1117/12.528641 · doi:10.1117/12.528641
- Pan, 1996, Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides, Anal. Chem., 68, 1124, 10.1021/ac950751x · DOI
- Gabriely, 1999, Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia, Diabetes Care, 22, 2026, 10.2337/diacare.22.12.2026 · DOI · Paper page
- So, 2011, Improved stability of blood glucose measurement in humans using near infrared spectroscopy, Spectroscopy, 25, 137, 10.1155/2011/542790 · doi:10.1155/2011/542790
- Maier, 1994, Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissue in the near infrared, Opt. Lett., 19, 2062, 10.1364/OL.19.002062 · DOI · Paper page
- Goetz, 1995, Application of a multivariate technique to raman spectra for quantification of body chemicals, IEEE Trans. Biomed. Eng., 42, 728, 10.1109/10.391172 · DOI
- Berger, 1999, Multicomponent blood analysis by near-infrared Raman spectroscopy, Appl. Opt., 38, 2916, 10.1364/AO.38.002916 · DOI · Paper page
- Hanlon, 2000, Prospects for in vivo raman spectroscopy, Phys. Med. Biol., 45, r1, 10.1088/0031-9155/45/2/201 · DOI · Paper page
- Tao, 2009, In vivo blood characterization from bioimpedance spectroscopy of blood pooling, IEEE Trans. Instrum. Meas., 58, 3831, 10.1109/TIM.2009.2020836 · DOI
- MacKenzie, 1999, Advances in photoacoustic noninvasive glucose testing, Clin. Chem., 45, 1587, 10.1093/clinchem/45.9.1587 · DOI · Paper page
- Lee, 2005, Glucose mea-surements with sensors and ultrasound, Ultrasound Med. Biol., 31, 971, 10.1016/j.ultrasmedbio.2005.04.004 · DOI
- McNichols, 2000, Optical glucose sensing in biological fluids: an overview, J. Biomed. Opt., 5, 5, 10.1117/1.429962 · DOI · Paper page
- So, 2012, Recent advances in noninvasive glucose monitoring, Med. Devices, 5, 45, 10.2147/MDER.S28134 · DOI · Paper page
- Larin, 2003, Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects, Proc. SPIE, 25, 2263, 10.2337/diacare.25.12.2263 · DOI · Paper page
- Larin, 2003, Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study, Phys. Med. Biol., 48, 1371, 10.1088/0031-9155/48/10/310 · DOI
- Fercher, 2003, Optical coherence tomography-principles and applications, Rep. Prog. Phys., 66, 635, 10.1088/0034-4885/66/2/204 · DOI · Paper page
- Solanki, 2012, Blood glucose monitoring in human subjects using optical coherence tomography, J. Opt., 41, 127, 10.1007/s12596-012-0067-z · DOI
- Zhang, 2013, Noninvasive blood glucose monitoring during oral intake of different sugars with optical coherence tomography in human subjects, J. Biophotonics, 6, 699, 10.1002/jbio.201200128 · DOI
- Esenaliev, 2001, Noninvasive monitoring of glucose concentration with optical coherence tomography, Opt. Lett., 26, 992, 10.1364/OL.26.000992 · DOI · Paper page
- Larin, 2001, Potential application of optical coherence tomography for noninvasive monitoring of glucose concentration, Proc. SPIE, 4263, 83, 10.1117/12.429342 · doi:10.1117/12.429342
- Bykov, 2010, Skin phantoms with realistic vessel structure for oct measurements, Proc. SPIE, 7376, 10.1117/12.872000 · doi:10.1117/12.872000
- Barnett, 2012, Linagliptin monotherapy in type 2 diabetes patients for whom metformin is inappropriate: an 18 week randomized, double-blind, placebo-controlled phase iii trial with a 34 week active-controlled extension, Diabetes Obes. Metab., 14, 1145, 10.1111/dom.12011 · DOI
- Qu, 1997, Monte Carlo modeling studies of the effect of physiological factors, andother analytes on the determination of glucose concentration in vivo by near infrared optical absorption and scattering measurements, J. Biomed. Opt., 2, 319, 10.1117/12.275453 · DOI
- Jensen, 1995, Glucose content in human skin: relationship with blood glucose levels, Scand. J. Clin. Lab. Invest., 55, 427, 10.3109/00365519509104982 · DOI · Paper page
- Stout, 2001, Comparison of glucose levels in dermal interstitial fluid and finger capillary blood, Diabetes Technol. Ther., 3, 81, 10.1089/152091501750220046 · DOI · Paper page
Cited by
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
“78, suggesting that OCT technology’s detection ability and accuracy in diabetics may be better than that of healthy people (Figure 6D) [77].”
BackgroundInfluentialSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
“A time lag of 10 mins was observed between a change in blood glucose concentration and an associated change in the OCT signal slope [128].”
BackgroundMethodPullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
“However, OCT is sensitive to motion artifact due to the inhomogeneity of tissue [115,116].”
Background
Metadata
- Authors
- Lan, Y. T., Kuang, Y. P., Zhou, L. P., Wu, G. Y., Gu, P. C., Wei, H. J., & Chen, K.
- Venue
- Laser Physics Letters
- Publisher
- IOP Publishing
- Published
- 2017-02-02
- Volume
- 14
- Issue
- 3
- Pages
- 035603
- ISSN
- 1612-2011 (ISSN-L)
- 1612-202X
- OpenAlex
- W2584998987
- Cited by
- 47
- References
- 2
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive monitoring of blood glucose concentration in diabetic patients with optical coherence tomography. https://app.cochat.ai/papers/10.1088/1612-202x/aa58c0
- The paper
- Lan, Y. T., Kuang, Y. P., Zhou, L. P., Wu, G. Y., Gu, P. C., Wei, H. J., & Chen, K. (2017). Noninvasive monitoring of blood glucose concentration in diabetic patients with optical coherence tomography. Laser Physics Letters. https://doi.org/10.1088/1612-202x/aa58c0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.