JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 50 of the 50 references it cites were found in a registry or an index.
Abstract
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical uncertainty compared to the previous strontium record set by the JILA SrII optical lattice clock at . This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to . A seven-fold improvement in clock stability, reaching for an averaging time in seconds, allows the clock to average to its systematic uncertainty in under 10 min. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the boulder area clock optical network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The atomic correction coefficient is well-known [49] and does not significantly contribute to the estimated uncertainty of 2 × 10 -18 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65874-3 · Cited by 5,025 · cited 3×
“where the index j enumerates the different surfaces of the vacuum chamber surrounding the atoms and Fi→j is the exchange factor defined as the fraction of total energy emitted by surface i that is absorbed by surface j directly or by reflection [21].”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560 · cited 1×
“Indeed, the JILA SrI clock has already been used in an atom cavity frequency intercomparison which highlights the long term stability of cryogenic crystalline cavities for timescales applications [37] and the search for timevariation of funda mental constants [38].”
MethodAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 10×
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [1, 2, 30] Sr OLCs.”
BackgroundMethodInfluentialSelf-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 14×
“Similarly, the range for β is chosen to encompass the weighted mean of values from published literature [2, 29, 25] to one which is consistent with what is observed in Fig.”
BackgroundMethodResultInfluentialSelf-citationInverse Radiative Heat Transfer
Modest, M. F. (2013) · Radiative Heat Transfer · doi:10.1016/b978-0-12-386944-9.50023-6 · Cited by 741
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
Background(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 2×
“Atomic clocks based on optical transitions have realized unprecedented levels of stability, reproducibility, and accuracy [1, 2, 3, 4, 5, 6].”
Background1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566 · cited 1×
“For narrow line spectroscopy, Doppler shifts between the clock laser and atoms trapped in the optical lattice are elimi nated by active optical path length stabilization [34].”
BackgroundSelf-citation
Research works printed but not linked: 2
- [32] B. X. R. Alves, Y. Foucault, G. Vallet, R. L. Targat, and J. Lodewyck, 'Background collisional shift on lattice-trapped strontium atoms,' EFTF Conference Proceedings , 2019. -
- [37] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 'Fundamentals, IP edition,' American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc , pp. 1-1, 2009. -
Cited by
Items 101–200 of 339
Narrow-line cooling of 87Rb using 5S 1 / 2 → 6P 3 / 2 open transition at 420 nm
Das, R. C., Shylla, D., Bera, A., & Pandey, K. (2022) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/acabf0 · Cited by 14
Excited-Band Coherent Delocalization for Improved Optical Lattice Clock Performance
Siegel, J. L., McGrew, W. F., Hassan, Y. S., Chen, C.-C., Beloy, K., Grogan, T., Zhang, X., & Ludlow, A. D. (2024) · Physical Review Letters · doi:10.1103/physrevlett.132.133201 · Cited by 17
“Nevertheless, clock transition shifts can still be significant at the 10 − 18 level [18, 19], sometimes even when atom number is intentionally restricted to decrease atomic density [3, 20].”
Background778.1 nm distributed feedback lasers for Rb two-photon atomic systems with sub-4 kHz linewidths
Gaetano, E. D., Keliehor, B., Gallacher, K. F., Griffin, P. F., Sorel, M., Riis, E., & Paul, D. J. (2024) · APL Photonics · doi:10.1063/5.0191088 · Cited by 13
Robust suppression of high-frequency laser phase noise by adaptive Pound-Drever-Hall feedforward
Chao, Y.-X., Hua, Z.-X., Liang, X.-H., Yue, Z.-P., Chen, J., You, L., & Tey, M. K. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.l011005 · Cited by 18
Cavity-immune spectral features in the pulsed superradiant crossover regime
Tang, M., Schäffer, S. A., Jørgensen, A. A., Henriksen, M. R., Christensen, B. T. R., Müller, J. H., & Thomsen, J. W. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.033258 · Cited by 14
An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity
Zhu, X.-Q., Cui, X.-Y., Kong, D.-Q., Yu, H.-W., Zhai, X., Zheng, M.-Y., Xie, X.-P., Zhang, Q., Jiang, X. Q., Zhang, X., et al. (2024) · Review of Scientific Instruments · doi:10.1063/5.0200553 · Cited by 13
Guo, Y., Pan, Z., Gong, X., Gao, S., Wang, P., Bai, Y., Song, K., Zhou, C., Gao, Y., Lu, X., et al. (2025) · Satellite Navigation · doi:10.1186/s43020-024-00155-4 · Cited by 12
“…(Wikipedia, 2024a, 2024b), and rubidium (Wikipedia, 2024a, 2024b) clocks) and optical atomic clocks (trapped-ion and optical lattice clocks (Bothwell et al., 2019; Brewer et al., 2019; Cao et al., 2017; Madej et al., 2012; McGrew et al., 2018; Rosenband et al., 2008; Sanner et al., 2019;…”
Free-space optical-frequency comparison over rapidly moving links
McSorley, S., Dix-Matthews, B. P., Frost, A. M., McCann, A., Karpathakis, S., Gozzard, D. R., Walsh, S. M., & Schediwy, S. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.l021003 · Cited by 15
Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition
Carman, S. P., Rudolph, J., Garber, B. E., de Graaff, M. J. V., Swan, H., Jiang, Y., Nantel, M. K. T., Abe, M., Barcklay, R. L., & Hogan, J. M. (2025) · Physical Review X · doi:10.1103/qk3v-46y8 · Cited by 18
“The most accurate optical atomic clocks use 1 S 0 − 3 P 0 singlet-to-triplet transitions in alkaline-earth-like neutral atoms and ions (e.g. Sr , Yb, Mg, Al + ) [11–14].”
Measurement of the 27 Al + and 87 Sr absolute optical frequencies
Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., Diddams, S. A., Fasano, R., Hassan, Y. S., Hume, D. B., et al. (2020) · Metrologia · doi:10.1088/1681-7575/abd040 · Cited by 14
Self-citationEvaluation of the blackbody radiation shift of an Yb optical lattice clock at KRISS
Heo, M.-S., Kim, H., Yu, D.-H., Lee, W.-K., & Park, C. Y. (2022) · Metrologia · doi:10.1088/1681-7575/ac8483 · Cited by 15
“Also, there has been a method of measuring Tatom directly using a thermal probe [16] (and additional FE analysis in [17]) in a well-controlled thermal environment.”
MethodOptical magnetism and wavefront control by arrays of strontium atoms
Ballantine, K. E., Wilkowski, D., & Ruostekoski, J. (2022) · Physical Review Research · doi:10.1103/physrevresearch.4.033242 · Cited by 12
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Smorra, C., Abbass, F., Schweitzer, D., Bohman, M., Devine, J., Dutheil, Y., Hobl, A., Arndt, B. P., Bauer, B. B., Devlin, J. A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0155492 · Cited by 15
Xu, Q., Lu, X., Xia, J., Wang, Y., & Chang, H. (2021) · Applied Physics Letters · doi:10.1063/5.0060277 · Cited by 12
Atomic Clock Ensemble in Space
Cacciapuoti, L., Busso, A., Jansen, R., Pataraia, S., Peignier, T., Weinberg, S., Crescence, P., Helm, A., Kehrer, J., Koller, S., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012005 · Cited by 16
Obaze-Adeleke, A. C., Semon, B., & Bandi, T. (2025) · Photonics · doi:10.3390/photonics12050513 · Cited by 14
Atomic Clock Frequency Ratios with Fractional Uncertainty ≤ 3.2 × 10 − 18
Aeppli, A., Arthur-Dworschack, W. J., Beloy, K., Berry, C. M., Bothwell, T., Folz, A., Fortier, T. M., Grogan, T. M., Hassan, Y. S., Hu, Z., et al. (2026) · Physical Review Letters · doi:10.1103/g865-9mk1 · Cited by 17
Self-citationSchröder, S., Stellmer, S., & Kusche, J. (2021) · Geophysical Journal International · doi:10.1093/gji/ggab132 · Cited by 13
Towards optical frequency geopotential difference measurements via a flying drone
Dix-Matthews, B. P., Gozzard, D. R., Walsh, S. M., McCann, A., Karpathakis, S., Frost, A. M., Gravestock, C., & Schediwy, S. (2023) · Optics Express · doi:10.1364/oe.483767 · Cited by 12
Contribution of negative-energy states to the E2−M1 polarizability of optical clocks
Wu, F.-F., Shi, T.-Y., Ni, W.-T., & Tang, L.-Y. (2023) · Physical Review A · doi:10.1103/physreva.108.l051101 · Cited by 11
Testing screened scalar-tensor theories of gravity with atomic clocks
Lévy, H., & Uzan, J. (2025) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.111.064012 · Cited by 11
Characterization of Errors in Interferometry with Entangled Atoms
Brif, C., Ruzic, B., & Biedermann, G. W. (2020) · PRX Quantum · doi:10.1103/prxquantum.1.010306 · Cited by 12
Bi-color atomic beam slower and magnetic field compensation for ultracold gases
Li, J., Lim, K. M. H., Das, S., Zanon-Willette, T., Feng, C.-H., Paul, R., Bertoldi, A. D., Bouyer, P., Kwong, C. C., Lan, S.-Y., et al. (2022) · AVS Quantum Science · doi:10.1116/5.0126745 · Cited by 11
Stabilized free space optical frequency transfer using digitally enhanced heterodyne interferometry
McSorley, S., Gozzard, D. R., Karpathakis, S., Dix-Matthews, B. P., & Schediwy, S. (2023) · Optics Letters · doi:10.1364/ol.492356 · Cited by 10
Yu, H., Liu, P., Li, Y., Jia, Z.-P., Zhang, X., Yan, J., Li, J., Dai, H.-N., & Chen, Y.-A. (2025) · Measurement · doi:10.1016/j.measurement.2025.118527 · Cited by 11
Stability improvement of 40 Ca + optical clock by using a transportable ultra-stable cavity
Hao, Y., Hu, R., Zhang, B., Zeng, M., Zhang, H., Ma, Z., Huang, Y., Chen, Q., Gao, K., & Guan, H. (2024) · Optics Express · doi:10.1364/oe.509502 · Cited by 13
Generation of a precise time scale assisted by a near-continuously operating optical lattice clock
Kobayashi, T., Akamatsu, D., Hosaka, K., Hisai, Y., Nishiyama, A., Kawasaki, A., Wada, M., Inaba, H., Tanabe, T., Suzuyama, T., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064015 · Cited by 13
Classical and quantum frequency combs for satellite-based clock synchronization
Gosalia, R., Aguinaldo, R., Green, J. T., Leopardi, H., Brereton, P., & Malaney, R. (2024) · APL Photonics · doi:10.1063/5.0220546 · Cited by 14
Programmable system on chip for controlling an atomic physics experiment
Sitaram, A., Campbell, G. K., & Restelli, A. (2021) · Review of Scientific Instruments · doi:10.1063/5.0047535 · Cited by 11
Geopotential Difference Measurement Using Two Transportable Optical Clocks’ Frequency Comparisons
Liu, D., Wu, L. F., Xiong, C., & Bao, L. (2024) · Remote Sensing · doi:10.3390/rs16132462 · Cited by 12
Influence of cosmological expansion in local experiments
Spengler, F., Belenchia, A., Rätzel, D., & Braun, D. (2022) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ac4954 · Cited by 11
“Just this year, a measurement of the frequency ratio between three atomic clocks with a fractional frequency uncertainty below 8 × 10−18 was reported in [37] and fractional stability of optical clocks to one part in 1018 [35] or even in 1019 [38] over average times of hundreds of seconds have been reached.”
BackgroundAn integrated high-flux cold atomic beam source for strontium
Li, J., Jia, Z.-P., Liu, P., Liu, X., Wang, D., Kong, D.-Q., Li, S.-M., Cui, X.-Y., Dai, H.-N., Chen, Y.-A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0162128 · Cited by 12
QSNET, a network of clock for measuring the stability of fundamental constants
Barontini, G., Boyer, V., Calmet, X., Fitch, N. J., Forgan, E. M., Godun, R. M., Goldwin, J., Guarrera, V., Hill, I. R., Jeong, M., et al. (2021) · Quantum Technology: Driving Commercialisation of an Enabling Science · doi:10.1117/12.2600493 · Cited by 13
Effect of optical lattice field on characteristics of a clock transition in thulium atoms
Mishin, D., Provorchenko, D. I., Tregubov, D. O., Golovizin, A. A., Khabarova, K. Y., Сорокин, В. Н., & Kolachevsky, N. (2022) · Quantum Electronics · doi:10.1070/qel18062 · Cited by 9
Generating 500 mW for laser cooling of strontium atoms by injection locking a high power laser diodePreprint
Schkolnik, V., Williams, J., & Yu, N. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2004.11732 · Cited by 9
Lu+ optical frequency references with accuracy verified at the 19th digit
Arnold, K. J., Lee, M. D. K., Zhao, Q., Qin, Q., Zhang, Z., Jayjong, N., & Barrett, M. D. (2026) · Nature · doi:10.1038/s41586-026-11072-8 · Cited by 16
Measurement of infrared magic wavelength for an all-optical trapping of 40Ca+ ion clock
Huang, Y., Wang, M., Chen, Z. L., Li, C., Zhang, H., Zhang, B., Tang, L., Shi, T.-Y., Guan, H., & Gao, K. (2024) · New Journal of Physics · doi:10.1088/1367-2630/ad3ea8 · Cited by 8
“For many neutral-atom optical lattice clocks [4, 5], the ac Stark shift due to black body radiation (BBR) or lattice lasers can be a limiting factor for achieving such high accuracy; for ion-based clocks, on the other hand, micromotion shifts may limit the accuracy of some clocks [2, 7].”
BackgroundRamsey-Bordé atom interferometry with a thermal strontium beam for a compact optical clock
Fartmann, O., Jutisz, M., Mahdian, A., Schkolnik, V., Tietje, I. C., Zimmermann, C., & Krutzik, M. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00332-7 · Cited by 9
“They are, however, still predominantly bound to controlled laboratory environments, although considerable progress is expected over the next decade [22–24].”
The antenna phase center motion effect in high-accuracy spacecraft tracking experiments
Литвинов, Д. А., Nunes, N. V., Filetkin, A. I., Bartel, N., Gurvits, L. I., Calvés, G. M., Rudenko, V. N., & Zakhvatkin, M. V. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.07.036 · Cited by 8
“Equations for the additional phase delay due to the effect, which might be of interest to the problem of simultaneously tracking SC by several ground antennas in the VLBI regime (Duev et al., 2012), are also provided.”
BackgroundOpen-loop polarization mode dispersion mitigation for fibre-optic time and frequency transfer
Fordell, T. (2022) · Optics Express · doi:10.1364/oe.448553 · Cited by 9
Losses of thulium atoms from optical dipole traps operating at 532 and 1064 nm
Tsyganok, V. V., Pershin, D. A., Khlebnikov, V., Kumpilov, D. A., Pyrkh, I. A., Rudnev, A. E., Fedotova, E. A., Gaifudinov, D. V., Cojocaru, I. S., Khoruzhii, K. A., et al. (2023) · Physical Review A · doi:10.1103/physreva.107.023315 · Cited by 9
Investigation of the 6s6p P03−4f135d6s2 ( J=2 ) Clock Transition in Yb171 Atoms
Qiao, H., Ai, D., Sun, C., Peng, C., Qi, Q.-C., Zhao, C., Luo, L., Jin, T., Zhang, T., Zhou, M., et al. (2024) · Physical Review X · doi:10.1103/physrevx.14.011023 · Cited by 9
Impacts of random filling on spin squeezing via Rydberg dressing in optical clocks
Damme, J. V., Zheng, X., Saffman, M. E., Vavilov, M., & Kolkowitz, S. (2021) · Physical Review A · doi:10.1103/physreva.103.023106 · Cited by 8
High-power, fiber–laser-based source for magic-wavelength trapping in neutral-atom optical clocks
Eckner, W. J., Young, A. W., Schine, N., & Kaufman, A. M. (2021) · Review of Scientific Instruments · doi:10.1063/5.0057619 · Cited by 8
Proposal for an active whispering-gallery microclock
Yu, D., Vollmer, F., & Zhang, S. (2023) · Quantum Science and Technology · doi:10.1088/2058-9565/acb3f2 · Cited by 9
Литвинов, Д. А. (2024) · Astronomy Letters · doi:10.1134/s1063773724700130 · Cited by 7
Quadratic Zeeman and electric quadrupole shifts in highly charged ions
Gilles, J., Fritzsche, S., Spieß, L. J., Schmidt, P. O., & Surzhykov, A. (2024) · Physical Review A · doi:10.1103/physreva.110.052812 · Cited by 7
Kraus, B., Herbers, S., Nauk, C., Sterr, U., Lisdat, C., & Schmidt, P. O. (2025) · Optics Letters · doi:10.1364/ol.544907 · Cited by 12
Low-power microstructured atomic oven for alkaline-earth-like elements
Pick, J., Voß, J., Hirt, S., Kruse, J., Leopold, T., Schwarz, R., & Klempt, C. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.014020 · Cited by 7
Gao, H., Chen, J., Liu, Z., Wang, F., Cai, Y., & Zhou, G. (2025) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2025.116872 · Cited by 9
Wang, L., Jiao, W., Hu, L., Chen, J., & Wu, G. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109365 · Cited by 8
Absolute frequency measurements with a robust, transportable 40Ca+ optical clock
Zhang, H., Huang, Y., Zhang, B., Hao, Y., Zeng, M., Chen, Q., Wang, Y., Cao, S., Lin, Y., Fang, Z., et al. (2023) · Metrologia · doi:10.1088/1681-7575/acd05d · Cited by 10
Wang, X., Shi, F., Gong, D., Xu, S., Li, Z., Fu, G., & Li, Q. (2020) · Metrologia · doi:10.1088/1681-7575/aba3b9 · Cited by 7
Combining machine learning with physics: A framework for tracking and sorting multiple dark solitons
Guo, S., Koh, S. M., Fritsch, A. R., Spielman, I. B., & Zwolak, J. P. (2022) · Physical Review Research · doi:10.1103/physrevresearch.4.023163 · Cited by 7
“Quantum research with BECs, and cold-atom quantum gases more broadly, is multifaceted with examples ranging from realizing collective many-body physics [28] to creating today’s most accurate atomic clocks [29].”
BackgroundProspective Optical Lattice Clocks in Neutral Atoms with Hyperfine Structure
Bothwell, T. (2024) · Atoms · doi:10.3390/atoms12030014 · Cited by 6
“OLCs based on Sr and Yb have both demonstrated fractional frequency inaccuracies at the low 10 − 18 level [3–5] and fractional frequency instabilities at the mid 10 − 17 level at 1 s [6,7].”
Self-citationRatchet loading and multi-ensemble operation in an optical lattice clock
Hassan, Y. S., Kobayashi, T., Bothwell, T., Siegel, J. L., Hunt, B. D., Beloy, K., Gibble, K., Grogan, T., & Ludlow, A. D. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad6286 · Cited by 9
“Optical lattice clocks (OLCs) continue to advance the forefront of frequency metrology owing to their state-of-the-art accuracies [1–3] and stabilities [4, 5].”
BackgroundSelf-citationInvestigation on the thermal property of a hydroxide catalysis bonded cryogenic cavity
Ye, Y.-X., Sun, Y., He, L., Wang, Z., Zhang, J., Chang, J., Wu, Q., Zhang, F., Lu, Z. H., & Zhang, J. (2021) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ac1be8 · Cited by 6
Lu, B., Lu, X., Li, J., & Chang, H. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac29a6 · Cited by 8
Design and simulation of a source of cold cadmium for atom interferometry
Bandarupally, S., Tinsley, J. N., Chiarotti, M., & Poli, N. (2023) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/acf3bf · Cited by 8
Limitation of single-repumping schemes for laser cooling of Sr atoms
Okamoto, N., Aoki, T., & Torii, Y. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.043088 · Cited by 6
Martin, K. W., Zaki, N., Matthews, N., Bigelow, M. S., Stuhl, B., Elgin, J., & Frey, K. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/adbc57 · Cited by 6
“The most precise optical atomic clocks have now demonstrated frequency stability at levels that reach below 1 × 10 − 17 in only 1000 s [1–6].”
Yu, D., Vollmer, F., Del’Haye, P., & Zhang, S. (2023) · Optics Express · doi:10.1364/oe.482722 · Cited by 6
A combined magnetic field stabilization system for improving the stability of 40Ca+ optical clock
Zeng, M., 马, Z. 子. M., Hu, R., 张, B. 宝. Z., 郝, Y. 艳. H., 张, H. 华. Z., 黄, Y. 垚. H., Guan, H., & 高, K. 克. G. (2023) · Chinese Physics B · doi:10.1088/1674-1056/acf5d5 · Cited by 6
Qiao, H., Sun, C., Peng, C., Qi, Q.-C., Zhao, C., Zhou, M., & Xu, X. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106439 · Cited by 7
A 6 month-long real-time time scale steered to NIM-Sr1 optical lattice clock
Zhu, L. F., Wang, Q., Wang, Y., Lin, Y., Yang, D., Li, Y., Yang, T., Meng, F., Lin, B., Tian, H., et al. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad774f · Cited by 7
Prospects for detecting new dark physics with the next generation of atomic clocks
Elder, B., Mentasti, G., Pasatembou, E., Baynham, C. F. A., Buchmueller, O. L., Contaldi, C., de Rham, C., Hobson, R., & Tolley, A. J. (2025) · Physical review. D/Physical review. D. · doi:10.1103/vghm-4s5p · Cited by 9
Critical thermal drifts in external fiber amplifiers limit optical frequency metrology
Tian, H., Liao, T., Volkov, M., Puppe, T., Predehl, K., LU, B., Fang, Z., Lin, Y., & Steinmeyer, G. (2025) · Optics Letters · doi:10.1364/ol.573411 · Cited by 5
Evolution of multilayer optical lattices based on linearly chirped circular Airyprime vortex beams
Gao, H., Chen, J., Zheng, Y., Liu, Z., Wang, F., Cai, Y., & Zhou, G. (2025) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2025.117451 · Cited by 6
Subradiant collective states for precision sensing via transmission spectra
Zafra-Bono, D., Rubies-Bigordà, O., & Yelin, S. F. (2026) · Physical Review A · doi:10.1103/rprq-bp61 · Cited by 11
Probe-Field-Ellipticity-Induced Shift in an Atomic Clock
Yudin, V. I., Taǐchenachev, A. V., Prudnikov, O. N., Basalaev, M. Y., Pal'chikov, V. G., von Boehn, M., Mehlstäubler, T. E., & Bagayev, S. N. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.014022 · Cited by 6
Jin, T., Zhang, T., Luo, L., Liu, L., Zhou, M., & Xu, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.112946 · Cited by 6
Shi, H., LU, B., Zhang, H., Hu, R., Qian, Y., Huang, Y., Yang, T., Yao, Y., Yu, H., Fang, Z., et al. (2024) · Photonics Research · doi:10.1364/prj.539892 · Cited by 6
Quantum sensing using atomic clocks for nuclear and particle physics
Kawasaki, A. (2025) · Applied Physics Reviews · doi:10.1063/5.0273813 · Cited by 10
Suppressing background spectra of lattice lasers in strontium optical clocks
Jia, Z.-P., Cui, X.-Y., Xie, Y.-J., Zhang, X., Niu, G.-Z., Liu, X.-Y., Zhu, Q., Li, J., & Dai, H.-N. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.014014 · Cited by 6
Doppler-free three-photon spectroscopy on narrow-line optical transitions
Panelli, G., Burd, S. C., Porter, E. J., & Kasevich, M. A. (2025) · Physical Review A · doi:10.1103/physreva.111.033112 · Cited by 5
“The three-photon Rabi frequency for the 1 S 0 ↔ 3 P 1 excitation scheme is a factor of 2 larger than the expression for the three-photon Rabi frequency in a ladder system [1].”
Analysis of Narrow-Line Laser Cooling and Trapping of Sr Atoms in Microgravity Environments
Ren, J., Liu, H., Lu, X., & Chang, H. (2020) · Applied Sciences · doi:10.3390/app10144928 · Cited by 5
A self-reference direct-measuring scheme for precision optical frequency ratio measurement
Fang, P., Sun, H., Wang, Y., Xu, Y., & Chen, Q. (2022) · Applied Physics B · doi:10.1007/s00340-022-07794-y · Cited by 5
Indigenisation of the Quantum Clock: An Indispensable Tool for Modern Technologies
De, S., & Sharma, A. (2023) · Atoms · doi:10.3390/atoms11040071 · Cited by 5
Absolute frequency measurement of the 6s6p3P0→5d6s3D1 transition based on ultracold ytterbium atoms
Ai, D., Jin, T., Zhang, T., Luo, L., Liu, L., Zhou, M., & Xu, X. (2023) · Physical Review A · doi:10.1103/physreva.107.063107 · Cited by 6
Atomic clocks compared with astounding accuracy
Godun, R. M. (2021) · Nature · doi:10.1038/d41586-021-00738-0 · Cited by 7
Hoang, A. T., Shen, Z., Shen, W., Cai, C., Xu, W. S., Ning, A., & Wu, Y. (2021) · Geodesy and Geodynamics · doi:10.1016/j.geog.2021.08.003 · Cited by 8
Femtosecond-comb based 10 MHz-to-optical frequency link with uncertainty at the 10 −18 level
Wada, M., & Inaba, H. (2022) · Metrologia · doi:10.1088/1681-7575/ac938d · Cited by 6
Accurate Determination of Blackbody Radiation Shifts in a Strontium Molecular Lattice Clock
Iritani, B., Tiberi, E., Skomorowski, W., Moszyński, R., Borkowski, M., & Zelevinsky, T. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.263201 · Cited by 6
Compact strontium atomic beam source based on a two-dimensional grating magneto-optical trap
Lee, H. G., Park, Y., Park, C. Y., Seo, M. H., Hong, H.-G., Lee, S.-B., Kwon, T. Y., Kang, S., Seo, S., Park, S. E., et al. (2025) · Physical Review Applied · doi:10.1103/htx8-dr68 · Cited by 4
Okamoto, N., Aoki, T., & Torii, Y. (2025) · Physical Review A · doi:10.1103/j7s7-b7mj · Cited by 5
Peik, E. (2023) · Wiley eBooks · doi:10.1002/9783527837427.ch14 · Cited by 4
Bose-Einstein condensate as a diagnostic tool for an optical lattice formed by 1064-nm laser light
Tsyganok, V. V., Pershin, D. A., Khlebnikov, V., Kumpilov, D. A., Pyrkh, I. A., Rudnev, A. E., Fedotova, E. A., Gaifudinov, D. V., Cojocaru, I. S., Khoruzhii, K. A., et al. (2023) · Physical Review A · doi:10.1103/physreva.108.013310 · Cited by 5
Laser cooling of thulium atoms to ground vibrational state in an optical lattice
Provorchenko, D. I., Tregubov, D. O., Golovizin, A. A., & Kolachevsky, N. (2024) · Physics-Uspekhi · doi:10.3367/ufne.2024.05.039678 · Cited by 4
Wu, C., Dong, C., & Ding, X. (2024) · Physics Letters A · doi:10.1016/j.physleta.2024.129805 · Cited by 4
Improved absolute frequency measurement of 171Yb at NMIJ with uncertainty below 2 × 10 − 16
Kobayashi, T., Nishiyama, A., Hosaka, K., Akamatsu, D., Kawasaki, A., Wada, M., Inaba, H., Tanabe, T., & Yasuda, M. (2025) · Metrologia · doi:10.1088/1681-7575/adb754 · Cited by 7
QED effects in quadratic Zeeman splitting in highly charged hydrogen-like ions
Agababaev, V. A., Prokhorchuk, E. A., Glazov, D. A., Malyshev, A. V., Шабаев, В. М., & Volotka, A. V. (2025) · Physical Review A · doi:10.1103/cpbv-l4z1 · Cited by 4
Lee, W.-K., Park, C. Y., Heo, M.-S., Yu, D.-H., & Kim, H. (2020) · Applied Optics · doi:10.1364/ao.404817 · Cited by 4
Detection of time variable gravity signals using terrestrial clock networks
Vincent, A., & Müller, J. (2023) · Advances in Space Research · doi:10.1016/j.asr.2023.07.058 · Cited by 7
Vector gap solitons of spin-orbit-coupled Bose-Einstein condensate in square optical lattice
Wang, Q., Tu, P., Ma, J.-P., Shao, K., Zhao, X., Xi, B., Song, Y., & Shi, Y.-R. (2024) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ad2e2c · Cited by 4
Toward a dual-species atom interferometer with cadmium and strontium
Tinsley, J. N., Bandarupally, S., Chiarotti, M., Manzoor, S., Sacco, M., & Poli, N. (2024) · AVS Quantum Science · doi:10.1116/5.0180042 · Cited by 5
Пилипенко, С. В., Литвинов, Д. А., Zakhvatkin, M. V., & Filetkin, A. I. (2024) · Astronomy Reports · doi:10.1134/s106377292470029x · Cited by 4
Enhancing Optical Lattice Clock Coherence Times with Erasure Conversion
Ma, S., Dolde, J., Zheng, X., Ganapathy, D., Shtov, A., Chen, J., Stöltzel, A., Christensen, B. J., & Kolkowitz, S. (2025) · PRX Quantum · doi:10.1103/2rqf-r9gw · Cited by 8
Non 0–0 states magnetically insensitive transitions in alkali species
Li, C., Sun, F., Liu, J., Li, X., Ma, J., Guo, G., Hou, D., & Zhang, S. (2020) · Physica Scripta · doi:10.1088/1402-4896/ab6ce3 · Cited by 4
Using optical clock transitions in Cu ii and Yb iii for timekeeping and search for new physics
Allehabi, S. O., Dzuba, V. A., & Flambaum, V. V. (2021) · Physical Review A · doi:10.1103/physreva.104.053109 · Cited by 5
Guan, H., Zhang, B., Zhang, H., Huang, Y., Hao, Y., Zeng, M., & Gao, K. (2021) · AVS Quantum Science · doi:10.1116/5.0056771 · Cited by 4
Metadata
- Authors
- Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Bothwell, Tobias
- ORCID
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2019-10-10
- Volume
- 56
- Issue
- 6
- Pages
- 065004
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2949469742
- Cited by
- 324
- References
- 49
- Citations by year
- 2026: 26 · 2025: 45 · 2024: 67 · 2023: 63 · 2022: 44 · 2021: 42 · 2020: 35 · 2019: 2
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Metrologia (publishedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion, cc-by-sa)
- Durham Research Online (Durham University) (acceptedVersion, cc-by-nc-nd)
- arXiv (Cornell University) (submittedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Funders
- National Science Foundation (1734006)
- Air Force Office of Scientific Research
- Defense Advanced Research Projects Agency
- National Institute of Standards and Technology
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, systematic uncertainties, clock stability, frequency ratio measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.