JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 50 of the 50 references it cites were found in a registry or an index.
Abstract
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical uncertainty compared to the previous strontium record set by the JILA SrII optical lattice clock at . This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to . A seven-fold improvement in clock stability, reaching for an averaging time in seconds, allows the clock to average to its systematic uncertainty in under 10 min. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the boulder area clock optical network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The atomic correction coefficient is well-known [49] and does not significantly contribute to the estimated uncertainty of 2 × 10 -18 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65874-3 · Cited by 5,025 · cited 3×
“where the index j enumerates the different surfaces of the vacuum chamber surrounding the atoms and Fi→j is the exchange factor defined as the fraction of total energy emitted by surface i that is absorbed by surface j directly or by reflection [21].”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560 · cited 1×
“Indeed, the JILA SrI clock has already been used in an atom cavity frequency intercomparison which highlights the long term stability of cryogenic crystalline cavities for timescales applications [37] and the search for timevariation of funda mental constants [38].”
MethodAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 10×
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [1, 2, 30] Sr OLCs.”
BackgroundMethodInfluentialSelf-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 14×
“Similarly, the range for β is chosen to encompass the weighted mean of values from published literature [2, 29, 25] to one which is consistent with what is observed in Fig.”
BackgroundMethodResultInfluentialSelf-citationInverse Radiative Heat Transfer
Modest, M. F. (2013) · Radiative Heat Transfer · doi:10.1016/b978-0-12-386944-9.50023-6 · Cited by 741
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
Background(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 2×
“Atomic clocks based on optical transitions have realized unprecedented levels of stability, reproducibility, and accuracy [1, 2, 3, 4, 5, 6].”
Background1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566 · cited 1×
“For narrow line spectroscopy, Doppler shifts between the clock laser and atoms trapped in the optical lattice are elimi nated by active optical path length stabilization [34].”
BackgroundSelf-citation
Research works printed but not linked: 2
- [32] B. X. R. Alves, Y. Foucault, G. Vallet, R. L. Targat, and J. Lodewyck, 'Background collisional shift on lattice-trapped strontium atoms,' EFTF Conference Proceedings , 2019. -
- [37] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 'Fundamentals, IP edition,' American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc , pp. 1-1, 2009. -
Cited by
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Self-citationFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationRoadmap on Atomtronics: State of the art and perspective
Amico, L., Boshier, M., Birkl, G., Minguzzi, A., Miniatura, C., Kwek, L.-C., Aghamalyan, D., Ahufinger, V., Anderson, D., Andrei, N., et al. (2021) · AVS Quantum Science · doi:10.1116/5.0026178 · Cited by 214
Kennedy, C. J., Oelker, E., Robinson, J. M., Bothwell, T., Kedar, D., Milner, W. R., Marti, G. E., Derevianko, A., & Ye, J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.201302 · Cited by 219
Self-citationHalf-minute-scale atomic coherence and high relative stability in a tweezer clock
Young, A. W., Eckner, W. J., Milner, W. R., Kedar, D., Norcia, M. A., Oelker, E., Schine, N., Ye, J., & Kaufman, A. M. (2020) · Nature · doi:10.1038/s41586-020-3009-y · Cited by 213
Self-citationClock with 8 × 10 − 19 Systematic Uncertainty
Aeppli, A., Kim, K., Warfield, W., Safronova, M. S., & Ye, J. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023401 · Cited by 211
Self-citationImproved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Universality of Dicke superradiance in arrays of quantum emitters
Masson, S. J., & Asenjo-Garcia, A. (2022) · Nature Communications · doi:10.1038/s41467-022-29805-4 · Cited by 163
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 211
“Fulfilment level: 80%–100% [30–32].”
BackgroundInfluentialDifferential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Direct comparison of two spin-squeezed optical clock ensembles at the 10−17 level
Robinson, J. M., Miklos, M., Tso, Y. M., Kennedy, C. J., Bothwell, T., Kedar, D., Thompson, J. K., & Ye, J. (2024) · Nature Physics · doi:10.1038/s41567-023-02310-1 · Cited by 173
Self-citationAll-optical frequency division on-chip using a single laser
Zhao, Y., Jang, J. K., Beals, G. J., McNulty, K. J., Ji, X., Okawachi, Y., Lipson, M. F., & Gaeta, A. L. (2024) · Nature · doi:10.1038/s41586-024-07136-2 · Cited by 128
Schlossberger, N., Prajapati, N., Berweger, S., Rotunno, A. P., Artusio‐Glimpse, A. B., Simons, M. T., Sheikh, A. A., Norrgard, E. B., Eckel, S., & Holloway, C. L. (2024) · Nature Reviews Physics · doi:10.1038/s42254-024-00756-7 · Cited by 116
Fundamental physics with a state-of-the-art optical clock in space
Derevianko, A., Gibble, K., Hollberg, L. W., Newbury, N. R., Oates, C. W., Safronova, M. S., Sinclair, L. C., & Yu, N. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac7df9 · Cited by 110
A Review of Commercial and Emerging Atomic Frequency Standards
Schmittberger, B. L., & Scherer, D. R. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3049713 · Cited by 111
Kerr-induced synchronization of a cavity soliton to an optical reference
Moille, G. T., Stone, J. R., Chojnacky, M., Shrestha, R., Javid, U. A., Menyuk, C. R., & Srinivasan, K. A. (2023) · Nature · doi:10.1038/s41586-023-06730-0 · Cited by 121
Demonstration of a Timescale Based on a Stable Optical Carrier
Milner, W. R., Robinson, J. M., Kennedy, C. J., Bothwell, T., Kedar, D., Matei, D. G., Legero, T., Sterr, U., Riehle, F., Leopardi, H., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.173201 · Cited by 82
Self-citationState-Dependent Optical Lattices for the Strontium Optical Qubit
Heinz, A., Park, A. J., Šantić, N., Trautmann, J., Porsev, S. G., Safronova, M. S., Bloch, I., & Blatt, S. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.203201 · Cited by 92
Point-to-point stabilized optical frequency transfer with active optics
Dix-Matthews, B. P., Schediwy, S., Gozzard, D. R., Savalle, E., Esnault, F.-X., Lévèque, T., Gravestock, C., D’Mello, D., Karpathakis, S., Tobar, M. E., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20591-5 · Cited by 89
Measuring the stability of fundamental constants with a network of clocks
Barontini, G., Blackburn, L., Boyer, V., Butuc-Mayer, F., Calmet, X., López-Urrutia, J. R. C., Curtis, E. A., Darquié, B., Dunningham, J., Fitch, N. J., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00130-5 · Cited by 95
Direct detection of ultralight dark matter bound to the Sun with space quantum sensors
Tsai, Y.-D., Eby, J., & Safronova, M. S. (2022) · Nature Astronomy · doi:10.1038/s41550-022-01833-6 · Cited by 65
Kobayashi, T., Takamizawa, A., Akamatsu, D., Kawasaki, A., Nishiyama, A., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Tanabe, T., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.241301 · Cited by 66
Miniaturized optical frequency reference for next-generation portable optical clocks
Maurice, V. N., Newman, Z. L., Dickerson, S. M., Rivers, M., Hsiao, J., Greene, P., Mescher, M., Kitching, J. E., Hummon, M. T., & Johnson, C. (2020) · Optics Express · doi:10.1364/oe.396296 · Cited by 94
Asteroids for μHz gravitational-wave detection
Fedderke, M. A., Graham, P. W., & Rajendran, S. (2022) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.105.103018 · Cited by 76
Evaluation of Lattice Light Shift at Low 10−19 Uncertainty for a Shallow Lattice Sr Optical Clock
Kim, K., Aeppli, A., Bothwell, T., & Ye, J. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.113203 · Cited by 79
Self-citationFrequency stability of cryogenic silicon cavities with semiconductor crystalline coatings
Kedar, D., Yu, J., Oelker, E. G., Staron, A. L., Milner, W. R., Robinson, J. M., Legero, T., Riehle, F., Sterr, U., & Ye, J. (2023) · Optica · doi:10.1364/optica.479462 · Cited by 83
Self-citationGENESIS: co-location of geodetic techniques in space
Delva, P., Altamimi, Z., Blazquez, A., Bloßfeld, M., Böhm, J., Bonnefond, P., Boy, J., Bruinsma, S., Bury, G., Chatzinikos, M., et al. (2023) · Earth Planets and Space · doi:10.1186/s40623-022-01752-w · Cited by 73
“Optical frequency standards at the leading national metrology institutes today show relative frequency inaccuracies in the 10−18 range (corresponding to 1 cm in height) and beyond (Brewer et al., 2019; Bothwell et al., 2019; Beloy et al., 2021).”
BackgroundThe $$^{229}$$Th isomer: prospects for a nuclear optical clock
von der Wense, L., & Seiferle, B. (2020) · The European Physical Journal A · doi:10.1140/epja/s10050-020-00263-0 · Cited by 65
“[Bothwell 2019] Bothwell, T. et al., JILA SrI optical lattice clock with uncertainty of 2.0 × 10−18, Metrologia 56 53 (2019) 065004.”
InfluentialUltrastable Free-Space Laser Links for a Global Network of Optical Atomic Clocks
Gozzard, D. R., Howard, L. A., Dix-Matthews, B. P., Karpathakis, S., Gravestock, C., & Schediwy, S. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.020801 · Cited by 70
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 60
Optical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock
Dörscher, S., Huntemann, N., Schwarz, R., Lange, R., Benkler, E., Lipphardt, B., Sterr, U., Peik, E., & Lisdat, C. (2021) · Metrologia · doi:10.1088/1681-7575/abc86f · Cited by 53
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 58
Testing gravity with cold-atom clocks in space: The ACES mission
Cacciapuoti, L., Armano, M., Much, R., Sy, O., Helm, A., Hess, M. P., Kehrer, J., Koller, S., Niedermaier, T., Esnault, F.-X., et al. (2020) · The European Physical Journal D · doi:10.1140/epjd/e2020-10167-7 · Cited by 50
A lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
Confinement of an alkaline-earth element in a grating magneto-optical trap
Sitaram, A., Elgee, P. K., Campbell, G. K., Klimov, N. N., Eckel, S., & Barker, D. S. (2020) · Review of Scientific Instruments · doi:10.1063/5.0019551 · Cited by 48
Robust control and optimal Rydberg states for neutral atom two-qubit gates
Mohan, M., de Keijzer, R., & Kokkelmans, S. J. J. M. F. (2023) · Physical Review Research · doi:10.1103/physrevresearch.5.033052 · Cited by 53
Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
Kim, H., Heo, M.-S., Park, C. Y., Yu, D.-H., & Lee, W.-K. (2021) · Metrologia · doi:10.1088/1681-7575/ac1950 · Cited by 51
“Several optical clocks have already achieved the frequency uncertainty around 1×10-18 level [6-10], and the roadmap for the redefinition of the second is seriously being discussed [5, 11].”
Schkolnik, V., Budker, D., Fartmann, O., Flambaum, V. V., Hollberg, L. W., Kalaydzhyan, T., Kolkowitz, S., Krutzik, M., Ludlow, A. D., Newbury, N. R., et al. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac9f2b · Cited by 47
Self-citationCooperative quantum-optical planar arrays of atoms
Ruostekoski, J. (2023) · Physical Review A · doi:10.1103/physreva.108.030101 · Cited by 47
Terahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level
Leung, K. H., Iritani, B., Tiberi, E., Majewska, I., Borkowski, M., Moszyński, R., & Zelevinsky, T. (2023) · Physical Review X · doi:10.1103/physrevx.13.011047 · Cited by 50
Improved interspecies optical clock comparisons through differential spectroscopy
Kim, M. E., McGrew, W. F., Nardelli, N. V., Clements, E., Hassan, Y. S., Zhang, X., Valencia, J. L., Leopardi, H., Hume, D. B., Fortier, T. M., et al. (2022) · Nature Physics · doi:10.1038/s41567-022-01794-7 · Cited by 43
Pound–Drever–Hall feedforward: laser phase noise suppression beyond feedback
Chao, Y.-X., Hua, Z.-X., Liang, X.-H., Yue, Z.-P., You, L., & Tey, M. K. (2024) · Optica · doi:10.1364/optica.516838 · Cited by 45
Demonstration of the nearly continuous operation of an 171 Yb optical lattice clock for half a year
Kobayashi, T., Akamatsu, D., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Suzuyama, T., Hong, F.-L., & Yasuda, M. (2020) · Metrologia · doi:10.1088/1681-7575/ab9f1f · Cited by 50
“6 6896 [4] McGrew W F, Zhang X, Fasano R J, Schäffer S A, Beloy K, Nicolodi D, Brown R C, Hinkley N, Milani G, Schioppo M, Yoon T H, and Ludlow A D 2018 Atomic clock performance enabling geodesy below the centimetre level Nature 564 87-90 [5] Bothwell T, Kedar D, Oelker E, Robinson J M, Bromley S L, Tew W L, Ye J, and…”
BackgroundSystematic uncertainty due to background-gas collisions in trapped-ion optical clocks
Hankin, A. M., Clements, E., Huang, Y., Brewer, S. M., Chen, J.-S., Chou, C. W., Hume, D. B., & Leibrandt, D. R. (2019) · Physical Review A · doi:10.1103/physreva.100.033419 · Cited by 48
A 87 Sr optical lattice clock with 2.9 × 10 − 17 uncertainty and its absolute frequency measurement
Lin, Y., Wang, Q., Meng, F., Cao, S., Wang, Y., Li, Y., Sun, Z. G., Lu, B.-K., Yang, T., Lin, B.-K., et al. (2021) · Metrologia · doi:10.1088/1681-7575/abf33e · Cited by 42
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“To reduce line pulling effects, we remove population from other Zeeman levels by resonant laser radiation on the 461 nm singlet transition after we have excited the population in m F = ± 9 / 2 from the ground state to the upper clock state by a short π -pulse in a large bias field.”
Blackbody radiation shift in strontium lattice clocks revisited
Lisdat, C., Dörscher, S., Nosske, I., & Sterr, U. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.l042036 · Cited by 37
Reduction of laser intensity noise over 1 MHz band for single atom trapping
Wang, Y., Wang, K., Fenton, E. F., Lin, Y.-W., Ni, K.-K., & Hood, J. D. (2020) · Optics Express · doi:10.1364/oe.405002 · Cited by 36
Golovizin, A. A., Tregubov, D. O., Fedorova, E. S., Mishin, D., Provorchenko, D. I., Khabarova, K. Y., Sorokin, V. N., & Kolachevsky, N. (2021) · Nature Communications · doi:10.1038/s41467-021-25396-8 · Cited by 34
Demonstration of a mobile optical clock ensemble at sea
Hilton, A. P., Offer, R. F., Klantsataya, E., Scholten, S. K., Hébert, N. B., Billington, C. J., Locke, C. R., Perrella, C., Nelligan, M., Allison, J. W., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61140-2 · Cited by 42
Optical atomic clock comparison through turbulent air
Bodine, M. I., Deschênes, J.-D., Khader, I. H., Swann, W. C., Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., et al. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033395 · Cited by 31
Self-citationAlgorithmic Ground-State Cooling of Weakly Coupled Oscillators Using Quantum Logic
King, S. A., Spieß, L. J., Micke, P., Wilzewski, A., Leopold, T., López-Urrutia, J. R. C., & Schmidt, P. O. (2021) · Physical Review X · doi:10.1103/physrevx.11.041049 · Cited by 33
Dynamical decoupling of laser phase noise in compound atomic clocks
Dörscher, S., Al-Masoudi, A., Bober, M., Schwarz, R., Hobson, R., Sterr, U., & Lisdat, C. (2020) · Communications Physics · doi:10.1038/s42005-020-00452-9 · Cited by 31
Lu, B.-K., Sun, Z. G., Yang, T., Lin, Y., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Li, T., & Fang, Z. (2022) · Chinese Physics Letters · doi:10.1088/0256-307x/39/8/080601 · Cited by 33
Subrecoil Clock-Transition Laser Cooling Enabling Shallow Optical Lattice Clocks
Zhang, X., Beloy, K., Hassan, Y. S., McGrew, W. F., Chen, C.-C., Siegel, J. L., Grogan, T., & Ludlow, A. D. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.113202 · Cited by 30
Lunar time in general relativity
Kopeikin, S. M., & Kaplan, G. H. (2024) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.110.084047 · Cited by 29
“Such clocks have been recently developed by researchers at JILA and the University of Colorado, Boulder [35, 36].”
MethodObservation of millihertz-level cooperative Lamb shifts in an optical atomic clock
Hutson, R. B., Milner, W. R., Yan, L., Ye, J., & Sanner, C. (2024) · Science · doi:10.1126/science.adh4477 · Cited by 38
Self-citationOptical frequency synthesizer referenced to an ytterbium optical clock
Yao, Y., Li, B., Yang, G. H., Chen, X., Hao, Y., Yu, H., Jiang, Y., & Ma, L.-S. (2021) · Photonics Research · doi:10.1364/prj.409534 · Cited by 27
Ytterbium optical lattice clock with instability of order 10 −18
Zhang, A., Xiong, Z.-X., Chen, X., Jiang, Y., Wang, J., Tian, C., Zhu, Q., Wang, B., Xiong, D., He, L., et al. (2022) · Metrologia · doi:10.1088/1681-7575/ac99e4 · Cited by 29
A basic introduction to ultrastable optical cavities for laser stabilization
Boyd, J. A., & Lahaye, T. (2023) · American Journal of Physics · doi:10.1119/5.0161369 · Cited by 25
Cold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 61
Searching for a fifth force with atomic and nuclear clocks
Brzemiński, D., Chacko, Z., Dev, A., Flood, I., & Hook, A. (2022) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.106.095031 · Cited by 25
Toward a Transportable Ca+ Optical Clock with a Systematic Uncertainty of 4.8 × 10 −18
Zeng, M., Huang, Y., Zhang, B., Hao, Y., Ma, Z., Hu, R., Zhang, H., Chen, Z., Wang, M., Guan, H., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064004 · Cited by 23
Thermal noise and mechanical loss of SiO2/Ta2O5 optical coatings at cryogenic temperatures
Robinson, J. M., Oelker, E., Milner, W. R., Kedar, D., Zhang, W., Legero, T., Matei, D. G., Häfner, S., Riehle, F., Sterr, U., et al. (2021) · Optics Letters · doi:10.1364/ol.413758 · Cited by 23
Self-citationOptical and Microwave Metrology at the 10−18 Level with an Er/Yb:glass Frequency Comb
Nardelli, N. V., Leopardi, H., Schibli, T. R., & Fortier, T. M. (2023) · Laser & Photonics Review · doi:10.1002/lpor.202200650 · Cited by 23
Adaptive Circuit Learning for Quantum Metrology
Ma, Z., Gokhale, P., Zheng, T.-X., Zhou, S., Yu, X., Jiang, L., Maurer, P. C., & Chong, F. T. (2021) · IEEE International Conference on Quantum Computing and Engineering (QCE) · doi:10.1109/qce52317.2021.00063 · Cited by 31
Lu, X., Guo, F., Wang, Y., Xu, Q., Zhou, C., Xia, J., Wu, W., & Chang, H. (2023) · Metrologia · doi:10.1088/1681-7575/acb05c · Cited by 24
NTSC SrII optical lattice clock with uncertainty of 2 × 10 − 18
Lu, X., Guo, F., Liu, Y., Cao, J., Li, J., Xia, J., Xu, Q., Lu, B., Wang, Y., & Chang, H. (2025) · Metrologia · doi:10.1088/1681-7575/addc77 · Cited by 27
Preliminary study of generating a local time scale with NIM 87Sr optical lattice clock
Zhu, L. F., Lin, Y., Wang, Y., Jia, Z., Wang, Q., Li, Y., Yang, T., & Fang, Z. (2022) · Metrologia · doi:10.1088/1681-7575/ac8992 · Cited by 23
Lindvall, T., Fordell, T., Hanhijärvi, K., Doležal, M., Rahm, J., Weyers, S., & Wallin, A. E. (2025) · Physical Review Applied · doi:10.1103/czlf-bfvp · Cited by 29
“0 × 10 − 15 − 1 / 2”
Adaptive Circuit Learning for Quantum Metrology
Ma, Z., Gokhale, P., Zheng, T.-X., Zhou, S., Yu, X., Jiang, L., Maurer, P., & Chong, F. T. (2020) · arXiv · doi:10.48550/arxiv.2010.08702 · Cited by 21
Ma, Z., Deng, K., Wang, Z. Y., Wei, W. Z., Hao, P., Zhang, H. X., Pang, L., Wang, B., Wu, F.-F., Liu, H. L., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044017 · Cited by 26
Simultaneous preparation of two initial clock states in a thulium optical clock
Fedorova, E. S., Golovizin, A. A., Tregubov, D. O., Mishin, D., Provorchenko, D. I., Сорокин, В. Н., Khabarova, K. Y., & Kolachevsky, N. (2020) · Physical Review A · doi:10.1103/physreva.102.063114 · Cited by 21
Atmospheric refraction corrections in ground-to-satellite optical time transfer
Stuhl, B. (2021) · Optics Express · doi:10.1364/oe.421620 · Cited by 20
Universality-of-clock-rates test using atom interferometry with T3 scaling
Pumpo, F. D., Friedrich, A., Ufrecht, C., & Giese, E. (2023) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.107.064007 · Cited by 25
Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles
Zheng, X., Dolde, J., & Kolkowitz, S. (2024) · Physical Review X · doi:10.1103/physrevx.14.011006 · Cited by 27
Optical Atomic Clocks for Redefining SI Units of Time and Frequency
Sharma, L., Rathore, H. K., Utreja, S., Neelam, N., Roy, A., De, S., & Panja, S. (2020) · MAPAN · doi:10.1007/s12647-020-00397-y · Cited by 20
Dipole-Dipole Frequency Shifts in Multilevel Atoms
Cidrim, A., Orioli, A. P., Sanner, C., Hutson, R. B., Ye, J., Bachelard, R., & Rey, A. M. (2021) · Physical Review Letters · doi:10.1103/physrevlett.127.013401 · Cited by 20
Self-citationBeloy, K. (2021) · Physical Review Letters · doi:10.1103/physrevlett.127.013201 · Cited by 21
Zhang, P., Zhang, Y., Li, M., Rao, B., Yan, L., Chen, F., Zhang, X.-F., Chen, Q., Jiang, H., & Zhang, S. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac40f6 · Cited by 20
The development of active optical clock
Zhang, J., Shi, T., Miao, J., & Chen, J. (2023) · AAPPS bulletin · doi:10.1007/s43673-023-00079-2 · Cited by 21
Modeling motional energy spectra and lattice light shifts in optical lattice clocks
Beloy, K., McGrew, W. F., Zhang, X., Nicolodi, D., Fasano, R., Hassan, Y. S., Brown, R. C., & Ludlow, A. D. (2020) · Physical Review A · doi:10.1103/physreva.101.053416 · Cited by 20
Testing the Einstein equivalence principle with two Earth-orbiting clocks
Litvinov, D., & Pilipenko, S. (2021) · Classical and Quantum Gravity · doi:10.1088/1361-6382/abf895 · Cited by 19
Trap-Induced ac Zeeman Shift of the Thorium-229 Nuclear Clock Frequency
Beloy, K. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.103201 · Cited by 24
Quantum Sensing with Erasure Qubits
Niroula, P., Dolde, J., Zheng, X., Bringewatt, J., Ehrenberg, A., Cox, K. C., Thompson, J., Gullans, M. J., Kolkowitz, S., & Gorshkov, A. V. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.080801 · Cited by 27
Quadruply Ionized Barium as a Candidate for a High-Accuracy Optical Clock
Beloy, K., Dzuba, V. A., & Brewer, S. M. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.173002 · Cited by 19
Clock-line photoassociation of strongly bound dimers in a magic-wavelength lattice
Bettermann, O., Oppong, N. D., Pasqualetti, G., Riegger, L., Bloch, I., & Fölling, S. (2023) · Physical Review A · doi:10.1103/physreva.108.l041302 · Cited by 17
A proof-of-concept model of compact and high-performance 87Sr optical lattice clock for space
Guo, F., Tan, W., Zhou, C.-H., Xia, J., Chen, Y.-X., Liang, T., Liu, Q., Liu, Y., He, D.-J., Zhou, Y.-Z., et al. (2021) · AIP Advances · doi:10.1063/5.0064087 · Cited by 16
The MOCAST+ Study on a Quantum Gradiometry Satellite Mission with Atomic Clocks
Migliaccio, F., Reguzzoni, M., Rosi, G., Braitenberg, C., Tino, G. M., Sorrentino, F., Mottini, S., Rossi, L., Koç, Ö., Batsukh, K., et al. (2023) · Surveys in Geophysics · doi:10.1007/s10712-022-09760-x · Cited by 18
Improved frequency ratio measurement with 87 Sr and 171 Yb optical lattice clocks at NMIJ
Hisai, Y., Akamatsu, D., Kobayashi, T., Hosaka, K., Inaba, H., Hong, F.-L., & Yasuda, M. (2021) · Metrologia · doi:10.1088/1681-7575/abc104 · Cited by 17
Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level
Liu, X.-Y., Liu, P., Li, J., Zhang, Y.-C., Wang, Y.-B., Jia, Z.-P., Zhang, X., Zhu, X.-Q., Kong, D.-Q., Song, W.-L., et al. (2025) · Physical Review Letters · doi:10.1103/zbpb-6qxb · Cited by 24
Improved systematic evaluation of a strontium optical clock with uncertainty below 1 × 10 − 18
Jia, Z.-P., Li, J., Kong, D.-Q., Zhang, X., Yu, H.-W., Liu, X.-Y., Zhang, Y.-C., Wang, Y., Zhu, X.-Q., Zhang, J.-H., et al. (2026) · Metrologia · doi:10.1088/1681-7575/ae449e · Cited by 26
“This is typically achieved through direct probe measurements [14, 26] or validated thermal models [2, 27].”
InfluentialMa, Z. Y., Liu, H.-X., Wei, W. Z., Yuan, W. H., Hao, P., Deng, Z., Che, H., Xu, Z., Cheng, F. H., Wang, Z., et al. (2020) · Applied Physics B · doi:10.1007/s00340-020-07479-4 · Cited by 15
Optical telecommunications-band clock based on neutral titanium atoms
Eustice, S., Filin, D., Schrott, J., Porsev, S. G., Cheung, C., Novoa, D., Stamper-Kurn, D., & Safronova, M. S. (2023) · Physical Review A · doi:10.1103/physreva.107.l051102 · Cited by 15
Precision measurement of M1 optical clock transition in Ni12+
Chen, S., Zhou, Z., Li, J., Zhang, T., Li, C., Shi, T.-Y., Huang, Y., Gao, K., & Guan, H. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.013030 · Cited by 15
Transportable strontium lattice clock with 4 × 10 − 19 blackbody radiation shift uncertainty
Nosske, I., Vishwakarma, C., Lücke, T., Rahm, J., Poudel, N., Weyers, S., Benkler, E., Dörscher, S., & Lisdat, C. (2025) · Quantum Science and Technology · doi:10.1088/2058-9565/ae1161 · Cited by 19
Lattice Light Shift Evaluations in a Dual-Ensemble Yb Optical Lattice Clock
Bothwell, T., Hunt, B. D., Siegel, J. L., Hassan, Y. S., Grogan, T., Kobayashi, T., Gibble, K., Porsev, S. G., Safronova, M. S., Brown, R. C., et al. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.033201 · Cited by 18
“[3], accounting for radial temperatures can introduce model dependent biases when atoms are not sufficiently cold relative to the trap depth.”
BackgroundMethodInfluentialSelf-citationAllehabi, S. O., Dzuba, V. A., & Flambaum, V. V. (2022) · Physical Review A · doi:10.1103/physreva.106.032807 · Cited by 15
High-accuracy optical clocks based on group-16-like highly charged ions
Allehabi, S. O., Brewer, S. M., Dzuba, V. A., Flambaum, V. V., & Beloy, K. (2022) · Physical Review A · doi:10.1103/physreva.106.043101 · Cited by 14
Metadata
- Authors
- Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Bothwell, Tobias
- ORCID
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2019-10-10
- Volume
- 56
- Issue
- 6
- Pages
- 065004
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2949469742
- Cited by
- 324
- References
- 49
- Citations by year
- 2026: 26 · 2025: 45 · 2024: 67 · 2023: 63 · 2022: 44 · 2021: 42 · 2020: 35 · 2019: 2
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Metrologia (publishedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion, cc-by-sa)
- Durham Research Online (Durham University) (acceptedVersion, cc-by-nc-nd)
- arXiv (Cornell University) (submittedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Funders
- National Science Foundation (1734006)
- Air Force Office of Scientific Research
- Defense Advanced Research Projects Agency
- National Institute of Standards and Technology
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, systematic uncertainties, clock stability, frequency ratio measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.