JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 50 of the 50 references it cites were found in a registry or an index.
Abstract
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical uncertainty compared to the previous strontium record set by the JILA SrII optical lattice clock at . This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to . A seven-fold improvement in clock stability, reaching for an averaging time in seconds, allows the clock to average to its systematic uncertainty in under 10 min. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the boulder area clock optical network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The atomic correction coefficient is well-known [49] and does not significantly contribute to the estimated uncertainty of 2 × 10 -18 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65874-3 · Cited by 5,025 · cited 3×
“where the index j enumerates the different surfaces of the vacuum chamber surrounding the atoms and Fi→j is the exchange factor defined as the fraction of total energy emitted by surface i that is absorbed by surface j directly or by reflection [21].”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560 · cited 1×
“Indeed, the JILA SrI clock has already been used in an atom cavity frequency intercomparison which highlights the long term stability of cryogenic crystalline cavities for timescales applications [37] and the search for timevariation of funda mental constants [38].”
MethodAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 10×
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [1, 2, 30] Sr OLCs.”
BackgroundMethodInfluentialSelf-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 14×
“Similarly, the range for β is chosen to encompass the weighted mean of values from published literature [2, 29, 25] to one which is consistent with what is observed in Fig.”
BackgroundMethodResultInfluentialSelf-citationInverse Radiative Heat Transfer
Modest, M. F. (2013) · Radiative Heat Transfer · doi:10.1016/b978-0-12-386944-9.50023-6 · Cited by 741
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
Background(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 2×
“Atomic clocks based on optical transitions have realized unprecedented levels of stability, reproducibility, and accuracy [1, 2, 3, 4, 5, 6].”
Background1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566 · cited 1×
“For narrow line spectroscopy, Doppler shifts between the clock laser and atoms trapped in the optical lattice are elimi nated by active optical path length stabilization [34].”
BackgroundSelf-citation
Research works printed but not linked: 2
- [32] B. X. R. Alves, Y. Foucault, G. Vallet, R. L. Targat, and J. Lodewyck, 'Background collisional shift on lattice-trapped strontium atoms,' EFTF Conference Proceedings , 2019. -
- [37] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 'Fundamentals, IP edition,' American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc , pp. 1-1, 2009. -
Cited by
Items 201–300 of 339
Effective sideband cooling in an ytterbium optical lattice clock
Wang, J.-Q., Zhang, A., Tian, C.-C., Yin, N., Zhu, Q., Wang, B., Xiong, Z.-X., He, L., & Lv, B.-L. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac5392 · Cited by 4
Frequency control of a lattice laser at 759 nm by referencing to Yb clock transition at 578 nm
Hao, Y., Yao, Y., Shi, H., Yu, H., Jiang, Y., & Ma, L.-S. (2022) · Chinese Optics Letters · doi:10.3788/col202220.120201 · Cited by 5
Entanglement-enhanced synchronous differential comparison
Yu, D., Chen, J., & Zhang, S. (2023) · Physical Review A · doi:10.1103/physreva.107.043120 · Cited by 4
Trap induced broadening in a potential hydrogen lattice clock
Scott, J. P., Potvliege, R. M., Carty, D., & Jones, M. P. A. (2024) · Metrologia · doi:10.1088/1681-7575/ad1e37 · Cited by 4
Zhou, C., Lu, X., Lu, B., Wang, Y., & Chang, H. (2021) · Applied Sciences · doi:10.3390/app11031206 · Cited by 5
“As the second-order Zeeman coefficient is −23.37(3) MHz/T2 [37], the fractional second-order Zeeman shift is 5.06(3) × 10−17.”
BackgroundInfluentialDetermining the atom number from detection noise in a one-dimensional optical lattice clock
Lu, X., Xia, J., Lu, B., Wang, Y., Wang, T., & Chang, H. (2022) · Applied Physics Letters · doi:10.1063/5.0085166 · Cited by 4
Laboratory constraints on ultralight axion-like particles from precision atomic spectroscopyPreprint
Berger, J., & Bhoonah, A. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2206.06364 · Cited by 4
Xiong, C., Liu, D., Wu, L., Bao, L., & Zhang, P. (2022) · Remote Sensing · doi:10.3390/rs14174141 · Cited by 3
Noise-induced servo errors in optical clocks utilizing Rabi interrogation
Lindvall, T., Wallin, A. E., Hanhijärvi, K., & Fordell, T. (2023) · Metrologia · doi:10.1088/1681-7575/acdfd4 · Cited by 3
Two-photon cooling of calcium atoms
Adamczyk, W., Koch, S., Politi, C., Passagem, H. F., Fischer, C., Filippov, P. I., Berterottière, F., Kienzler, D., & Home, J. (2025) · Physical Review A · doi:10.1103/physreva.111.043101 · Cited by 3
Progresses on Th-doped materials for solid-state nuclear clock
赵, C.-C. 呈. Z., 李, L. 琳. L., 李, S.-M. 善. L., 龚, Q.-R. 巧. G., 张, P.-X. 沛. Z., 杭, Y. 寅. H., 马, L.-S. 龙. M., & 祝, S.-N. 世. Z. (2025) · Chinese Physics B · doi:10.1088/1674-1056/ae210f · Cited by 4
Direct measurement of the 5 s 5 p P 1 1 → 5 s 4 d D 2 1 decay rate in strontium
Okamoto, N., Aoki, T., & Torii, Y. (2026) · Physical Review A · doi:10.1103/8b7c-l2jl · Cited by 4
Systematic Frequency Shifts in Bi-color Tm Optical Clock
Golovizin, A. A., Tregubov, D. O., Fedorova, E. S., Mishin, D., Provorchenko, D. I., Сорокин, В. Н., Khabarova, K. Y., & Kolachevsky, N. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604304 · Cited by 3
Fock-space relativistic coupled-cluster calculations of clock-transition properties in Pb 2 +
Gakkhar, P., Kumar, R., Angom, D., & Mani, B. K. (2024) · Physical Review A · doi:10.1103/physreva.110.013119 · Cited by 3
中国光学十大进展:超冷中性原子光钟及其量子参考体系囚禁方案(特邀)
Yanhua, 周. Z., Chang, H., & Tao, 汪. W. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop232669 · Cited by 3
Scientific Objectives of the Lunar Millimeter and Submillimeter Observatory
Лихачев, С. Ф., Larchenkova, T. I., Andrianov, A. S., Vasiliev, E. O., Литвинов, Д. А., Пилипенко, С. В., Rudnitskiy, A. G., & Щуров, М. А. (2024) · Astronomy Letters · doi:10.1134/s1063773725700112 · Cited by 3
Direct loading of a Sr magneto-optical trap from a thermal atomic beam
Okamoto, N., Sato, T., Aoki, T., & Torii, Y. (2026) · Review of Scientific Instruments · doi:10.1063/5.0311769 · Cited by 3
“Direct loading of a grating MOT using a Sr dispenser without employing a Zeeman slower has been demonstrated 42 , but maintaining UHV conditions requires a differential pumping tube and the number of trapped 88 Sr atoms is limited to approximately 10 6 .”
Magic wavelength at 477 nm for the strontium clock transition
Ma, X., Das, S., Wilkowski, D., & Kwong, C. C. (2025) · Physical Review Applied · doi:10.1103/ycr9-wyq2 · Cited by 5
A High Performance and Portable Optically Pumped Cesium Beam Frequency Standard
He, X., Wang, Q., Xie, W., Chen, N., Xiong, Z., Qi, X., & Chen, X. (2020) · Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF) · doi:10.1109/ifcs-isaf41089.2020.9234812 · Cited by 3
“Abstract—As optical frequency standard [1]–[4] and frequency comb developed with quite high precision(10−18 or 10−19) and commercial H-maser developed with quite good short-term stability(10−15), the only and core competitiveness of Cesium beam frequency standards(CBFS) are reliability and long-term stability today.”
BackgroundGuodong, 赵. Z., Lu, X., & Chang, H. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop223237 · Cited by 3
Synchronous Comparison of Two Thulium Optical Clocks
Golovizin, A. A., Mishin, D., Provorchenko, D. I., Tregubov, D. O., & Kolachevsky, N. (2024) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364024600873 · Cited by 5
Hyperfine-induced frequency shifts for the candidate clock transitions in the Ni 12 + 61 ion
Zhang, T., Li, C., & Shi, T.-Y. (2024) · Physical Review A · doi:10.1103/physreva.110.032801 · Cited by 3
Optically steered time scale generation at OP and NPL and remote comparisons
Abgrall, M., Chupin, B., Uhrich, P., Lorini, L., Targat, R. L., Pointard, B., Lodewyck, J., Tunesi, J., Tran, D. B. A., Parsons, A. O., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012024 · Cited by 4
Determining the Magic Wavelength Without Modulation of the Trap Depth
Xia, J., Guo, F., Zhou, Y., Lu, X., & Chang, H. (2024) · Optics · doi:10.3390/opt5040040 · Cited by 2
“However, the density shift in a lattice-trapped system, which is contingent upon the trap depth and comparable to the AC Stark shift induced by the trap light, necessitates careful correction under varying trap depths [17,18,20].”
Optically Referenced Microwave Generator with Attosecond-Level Timing Noise
Yan, L., Ruan, J., Zhang, P., Rao, B., Li, M., Du, Z., & Zhang, S. (2025) · Photonics · doi:10.3390/photonics12020153 · Cited by 2
Enhancing optical clock stability via decoupling laser frequency noise and systematic effects
Qi, Q., Zhang, T., Jin, T., Lei, S., Xia, Y., Zhang, J., Chang, H., Feng, S., Liu, X., Wang, J., et al. (2025) · Chinese Optics Letters · doi:10.3788/col202523.092703 · Cited by 2
171 Yb optical lattice clock with uncertainty below 5×10 −18
Zhang, T., Jin, T., 戚其超, Lei, S., Xia, Y., Zhang, J., Chang, H., Feng, S., Liu, X., Wang, J., et al. (2026) · Metrologia · doi:10.1088/1681-7575/ae4aaf · Cited by 3
Semenko, A. V., Belotelov, G. S., Sutyrin, D. V., Slyusarev, S. N., Yudin, V. I., Taǐchenachev, A. V., Ovsiannikov, V. D., & Pal'chikov, V. G. (2021) · Quantum Electronics · doi:10.1070/qel17585 · Cited by 2
Performance manipulation of the squeezed coherent light source based on four-wave mixing
Jin, L. (2021) · Optics Express · doi:10.1364/oe.435735 · Cited by 2
Decoherence of Atomic Ensembles in Optical Lattice Clocks by Gravity
Kawasaki, A. (2022) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.91.034301 · Cited by 3
Gravitational redshift test using Rb clocks of eccentric GPS satellites
Fathollahi, L., Wu, F., & Pongračić, B. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e13178 · Cited by 3
Open-source electronics ecosystem for optical atomic clocks
Morzyński, P., Bilicki, S., Bober, M., Ledziński, A., Witkowski, M., Zarei, M., & Zawada, M. (2023) · Measurement Science and Technology · doi:10.1088/1361-6501/acc5a1 · Cited by 3
A cryogenic radio-frequency ion trap for a 40Ca+ optical clock
Zeng, M., 黄, Y. 垚. H., 张, B. 宝. Z., 马, Z. 子. M., 郝, Y. 艳. H., Hu, R., 张, H. 华. Z., Guan, H., & 高, K. 克. G. (2023) · Chinese Physics B · doi:10.1088/1674-1056/acc807 · Cited by 2
Estimation of instability induced by probe laser frequency noise in cold-atom microwave clocks
Yang, B., Zhao, H., Xiao, L., Li, X., Deng, J., & Cheng, H.-D. (2023) · Journal of the Optical Society of America B · doi:10.1364/josab.476894 · Cited by 2
Two-Dimensional Magneto-optical Trap for Producing a Flux of Cold Thulium Atoms
Yaushev, M. O., Mishin, D., Tregubov, D. O., Provorchenko, D. I., Колачевский, Н. Н., & Golovizin, A. A. (2023) · Journal of Experimental and Theoretical Physics · doi:10.1134/s1063776123080162 · Cited by 3
Optimization of Feedback-Loop Parameters in Thulium Optical Clocks at Synchronous Comparison
Tregubov, D. O., Provorchenko, D. I., Mishin, D., Колачевский, Н. Н., & Golovizin, A. A. (2023) · Journal of Experimental and Theoretical Physics · doi:10.1134/s1063776123080150 · Cited by 2
Hu, Y., Lock, M. P. E., & Woods, M. P. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad752c · Cited by 3
“Here we examine the potential for the interference effect to be observed in optical lattice clocks, which are ideal due to both their ultra-high precision [25–27], and the degree of control of their spatial degrees of freedom [28–32].”
Transportable optical cavity systems for terrestrial and space-borne portable optical atomic clocks
Pal, R., Yadav, V., & Sharma, A. (2024) · Frontiers in Quantum Science and Technology · doi:10.3389/frqst.2024.1438345 · Cited by 3
“For example, notable stationary clock laser systems developed by (Bothwell et al., 2019; Schwarz et al., 2020) demonstrate instability levels of approximately 5 × 10 − 17 / (cid:1) τ √ ( τ refers to total averaging time) as compared to the portable clock laser system from (Herbers et al., 2022)…”
Zixiao, M., ZHANG, B., HUANG, Y., Gao, K., & Hua, G. (2025) · Acta Physica Sinica · doi:10.7498/aps.74.20250048 · Cited by 2
Three-Dimensional Paul Trap with High Secular Frequency for Compact Optical Clock
Semerikov, I. A., Zalivako, I. V., Borisenko, A. S., Aksenov, M. A., Vishnyakov, P., Sidorov, P., Колачевский, Н. Н., & Khabarova, K. Y. (2019) · Bulletin of the Lebedev Physics Institute · doi:10.3103/s1068335619090070 · Cited by 3
Active Optical Clock Based on Laser Cooling of Alkali-metal Atoms
Shi, T., Pan, D., Zhuang, W., Guan, X., Miao, J., Zhang, J., & Chen, J. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604323 · Cited by 2
“Current state-of-the-art neutral optical lattice clocks and single-ion optical clocks have achieved the frequency stability of 10−18 [1]–[3] by adopting ultra-stable optical cavities.”
BackgroundStudy of loss dynamics of strontium in a magneto-optical trapPreprint
Vishwakarma, C., Patel, K., Mangaonkar, J., MacLennan, J., Biswas, K., & Rapol, U. D. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1905.03202 · Cited by 3
Detection of Time Variable Gravity Signals using Terrestrial Clock Networks
Vincent, A., Mueller, J., & Wu, H. (2022) · EGU General Assembly Conference Abstracts · doi:10.5194/egusphere-egu22-1743 · Cited by 2
Precise measurement of 171Yb magnetic constants for 1 S 0–3 P 0 clock transition
Zhang, A., Tian, C., Zhu, Q., Wang, B., Xiong, D., Xiong, Z.-X., He, L., & Lyu, B. (2022) · Chinese Physics B · doi:10.1088/1674-1056/aca14e · Cited by 2
Degenerate Rabi spectroscopy of the Floquet engineered optical lattice clock
Liu, W., Lu, X., Li, T., Zhang, X., Chang, H., Wang, T., & Li, W. (2023) · Physical Review A · doi:10.1103/physreva.107.013315 · Cited by 1
Ryuichi, I., Hachisu, H., Sekido, M., Ido, T., Hiraoka, Y., Harima, E., Fukaya, S., Matsuo, K., Nakashima, M., Aoyama, Y., et al. (2023) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass57860.2023.10265431 · Cited by 1
Evaluation of Stability of Higher-Order Atomic Clocks by Higher-Order Allan Variance
Ichimura, T., Kawaguchi, T., Yano, Y., Hanado, Y., & Ishizaki, T. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.405 · Cited by 1
Stability analysis in an optical lattice clock using the four-path measurement
Lu, X., Guo, F., Xia, J., Liu, Y., Lu, B., & Chang, H. (2024) · Physical Review A · doi:10.1103/physreva.109.023111 · Cited by 1
Superradiant active optical atomic clocks: motivations and current challenges
Matusko, M., & Delehaye, M. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012045 · Cited by 3
Contributions of the optical lattice clock NICT-Sr1 to TAI calibration and UTC(NICT) steering
Hachisu, H., Nemitz, N., Tønnes, M., Ito, H., Ohtsubo, N., Miyauchi, Y., Morikawa, M., Matsubara, K., Gotoh, T., & Ido, T. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012018 · Cited by 5
“A variety of optical clocks [1-3] have published budgeted uncertainties approaching or surpassing 2 × 10 −18 , and accurate frequency comparisons through optical carrier transfer [4-6] rather than microwave links are now routinely conducted.”
Frequency combs for precision synthesis and characterization of optical atomic standards
Fortier, T. M. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012021 · Cited by 1
Wu, C., Ding, X., & Dong, C. (2025) · New Journal of Physics · doi:10.1088/1367-2630/ade46e · Cited by 2
Thermal Effect of Acousto-Optic Frequency Shifter and Its Impact on Optical Metrology
Li, R., Tian, H., Dong, D., Lin, Y., & Zhou, W. (2025) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2025.3600059 · Cited by 1
“56 × 10 − 20 at 10,000 s averaging time, which is at least one order magnitude below the best optical atomic clock [28].”
Salah, W. (2026) · Physics Open · doi:10.1016/j.physo.2026.100387 · Cited by 1
Zhang, J., Xiao, Y., Wang, J., Zhang, W., Dai, H., Cheng, Y., Lian, J., Zhang, J., Yang, W., Li, D., et al. (2026) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ae6161 · Cited by 1
Systematic uncertainties in strontium optical lattice clocks
Foucault, Y., Alves, B. X. R., Moreno, W., Targat, R. L., & Lodewyck, J. (2020) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem49742.2020.9191772 · Cited by 1
“Abstract—Current optical clocks already out-perform microwave clocks and have published uncertainty budgets at the 10−18 level and below [1][2][3].”
BackgroundEvaluation of systematic uncertainty for transportable 87Sr optical lattice clock
Kong, D., Guo, F., Li, T., Lu, X.-T., Wang, Y., & Chang, H. (2021) · Acta Physica Sinica · doi:10.7498/aps.70.20201204 · Cited by 1
Systematic Effects in Strontium Optical Lattice Clocks
Foucault, Y., Moreno, W., Alves, B. X. R., Targat, R. L., & Lodewyck, J. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604301 · Cited by 1
Ultrastable, ultraprecise, portable
Krok, P., & Simpson, M. (2022) · PhotonicsViews · doi:10.1002/phvs.202200049 · Cited by 1
A proposal for detecting weak electromagnetic waves around 2.6 μm wavelength with Sr optical clock
韩, R.-S. 弱. H., 王, W. 伟. W., & 汪, T. 涛. W. (2024) · Chinese Physics B · doi:10.1088/1674-1056/ad1b45 · Cited by 1
Chamoli, S., Mishra, A., Dutta, A. K., Kesarkar, R. S., & Sahoo, B. K. (2024) · Physical Review A · doi:10.1103/physreva.109.063111 · Cited by 2
Slichenie dvukh opticheskikh chasov na atomakh tuliya s ispol'zovaniem sinkhronnogo oprosa
Golovizin, A. A., Mishin, D., Provorchenko, D. I., Tregubov, D. O., & Kolachevskiy, N. N. (2024) · Письма в Журнал экспериментальной и теоретической физики · doi:10.31857/s1234567824090039 · Cited by 1
Reducing Uncertainty in an Optical Lattice Clock
Dai, H.-N., & Chen, Y.-A. (2024) · Physics · doi:10.1103/physics.17.118 · Cited by 1
METODY I SISTEMY SRAVNENIYa ChASTOT TERRITORIAL'NO UDALENNYKh OPTIChESKIKh STANDARTOV
Semenko, A. V., Андреевич, К. А., Fedorova, D. M., Malimon, A. N., Sutyrin, D. V., Slyusarev, S. N., Fedotov, V. N., & Donchenko, S. I. (2024) · Журнал Экспериментальной и Теоретической Физики · doi:10.31857/s0044451024100043 · Cited by 1
Литвинов, Д. А. (2024) · Письма в астрономический журнал Астрономия и космическая астрофизика · doi:10.31857/s0320010824040016 · Cited by 1
Sr Optical Lattice Clock and Precision Optical Frequency Measurement at NIM
Yang, T., Lü, B., Zhu, L., Liao, T., Wang, Q., Li, Y., Meng, F., Lin, B., Wang, Y., Fang, F., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012047 · Cited by 2
Литвинов, Д. А. (2024) · Astronomy Letters · doi:10.1134/s1063773724700415 · Cited by 1
Low-noise fiber laser systems at 689 nm and 698 nm for strontium
Pertoldi, A., Jha, A., Hauge, J. M., Wayland, J., Kale, Y. B., Singh, Y., Montague, P. B., & Varming, P. (2025) · Optics Express · doi:10.1364/oe.555332 · Cited by 2
Measurement of Infrared Magic Wavelength for an All-Optical Trapping of 40ca+ Ion ClockPreprint
Huang, Y., Wang, M., Chen, Z. L., Li, C., Zhang, H., Zhang, B., Tang, L., Shi, T.-Y., Guan, H., & Gao, K. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4624682 · Cited by 1
Interféromètre à atomes froids piégés sur puce avec séparation spatiale
Wirtschafter, B. (2022) · theses.fr (ABES) · doi:10.70675/00c3eaccz5207z478bzb9bezc1562ec7d65e · Cited by 6
Ion Clock Busts into New Precision Regime
Dubé, P. (2019) · Physics · doi:10.1103/physics.12.79
Laser cooling of atoms at narrow optical transitions in fields with a polarisation gradient
Ilenkov, R. Y., Prudnikov, O. N., Taǐchenachev, A. V., & Yudin, V. I. (2020) · Quantum Electronics · doi:10.1070/qel17337
Superfluid confines exotic atoms without disrupting precision measurements
Matsuo, Y. (2022) · Nature · doi:10.1038/d41586-022-00688-1
Ding, Y.-J., Cao, S., Lin, B.-K., Wang, Q., Han, Y., & Fang, Z. (2022) · Acta Physica Sinica · doi:10.7498/aps.71.20220147
Adapted Method of Moments for Determining the Transition Frequency
Solovyev, D. A., & Solovyeva, E. V. (2021) · Physics Letters A · doi:10.1016/j.physleta.2022.128021
Towards a Transportable Yb Lattice Clock at SYRTE
Moreno, W., Rahmouni, F., Pointard, B., Pottie, P.-É., Delva, P., Lodewyck, J., Targat, R. L., González, J. R., Lalancette, M.-F., Lion, G., et al. (2022) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs54560.2022.9850674
Density shift measurement and synchronous frequency comparison based on in situ imaging technique
Hu, X., Lu, X., Zhang, X.-F., & Chang, H. (2022) · Acta Physica Sinica · doi:10.7498/aps.71.20220600
Guo, F., Lu, X., Zhou, C., & Chang, H. (2022) · Applied Sciences · doi:10.3390/app122211618
Precise Laser Frequency Measurement of Weak Power With Submegahertz Linewidth
Peng, C., Qiao, H., Zhang, S. H., Luo, L., Zhou, M., & Xu, X. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3298427
Yingxin, 陈. C., Lu, X., & Chang, H. (2023) · Acta Optica Sinica · doi:10.3788/aos230444
Higher-Order Allan Variance for Frequency Stability Evaluation of Multi-Dimensional Atomic Clocks
Ichimura, T., Kawaguchi, T., Yano, Y., Hanado, Y., & Ishizaki, T. (2023) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.143.1017 · Cited by 1
Towards a Sr Optical Lattice Clock at ROA : First implementations
Martínez, H. Á., Perales, A. E., Delgado, I. C., González, J. R., de Arellano, J. M. S. R., Suárez, V. B., Sánchez, J. M. G., Bohórquez, J. C., Vélez, C., Pinillos, H. E., et al. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272210
“Optical atomic frequency standards are at the vanguard of frequency metrology and their performances have led to an improvement of two orders of magnitude, both in stability and accuracy, with respect to the best primary frequency standards [1-3].”
BackgroundEngineering Optical Clocks for GNSS Timing Reference Applications
Qian, Y., Zhang, H., Zeng, M., Wang, B., Hao, Y., Du, L., Lu, J., Wang, Y., Wang, M., Huang, Y., et al. (2023) · Lecture notes in electrical engineering · doi:10.1007/978-981-99-6944-9_36
Xu, Q., Wang, S., Lu, X., Guo, F., Xia, J., Wang, Y., & Chang, H. (2023) · Tenth International Conference on Information Optics and Photonics · doi:10.1117/12.3007763
“Optical clocks have shown the ability to be extremely precise recently, the uncertainty and stability of the best optical clocks have achieved E-19 level [1,2] .”
BackgroundTerahertz Vibrational Molecular Clock
Leung, K. H. (2023) · Springer theses · doi:10.1007/978-3-031-47647-1_5 · Cited by 1
Demonstration of Real-Time Precision Optical Time Synchronization in a True Three-Node Architecture
Martin, K. W., Bigelow, M. S., Zaki, N., Stuhl, B., Matthews, N., Elgin, J., & Frey, K. (2024) · Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting · doi:10.33012/2024.19591
Zhao, G., Guo, F., Lu, X., & Chang, H. (2024) · Applied Sciences · doi:10.3390/app14051758
“Ultra-cold atoms confined within an optical lattice have played a pivotal role in the development of modern atomic clocks [1–3], the advancement of quantum techniques [4–8], and the exploration of fundamental physics [9–12].”
BackgroundHorloge optique miniature à ion piégé
Achi, B. (2022) · theses.fr (ABES) · doi:10.70675/37eec1a1z10a3z4a88zb28fzd23577d8ea4c · Cited by 1
Two-Dimensional Magneto-optical Trap for Producing a Flux of Cold Thulium Atoms
Yaushev, M. O., Mishin, D., Tregubov, D. O., Provorchenko, D. I., Kolachevskiy, N. N., & Golovizin, A. A. (2023) · Журнал Экспериментальной и Теоретической Физики · doi:10.31857/s0044451023080060
Optimization of Feedback-Loop Parameters in Thulium Optical Clocks at Synchronous Comparison
Tregubov, D. O., Provorchenko, D. I., Mishin, D., Kolachevskiy, N. N., & Golovizin, A. A. (2023) · Журнал Экспериментальной и Теоретической Физики · doi:10.31857/s0044451023080084
Wenmin, 廖. L., Sihui, 张. Z., Yuqing, 段. D., Jie, 王. W., & Haibin, 武. W. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop231135
Compensation of the multipolar polarizability shift in optical lattice clocks
Golovizin, A. A. (2024) · Optics Letters · doi:10.1364/ol.524104 · Cited by 1
“Optical clocks became extremely precise instruments surpassing microwave frequency standards by two orders of magnitude in frequency accuracy and stability [1–4].”
BackgroundModular Fiber Laser Platform for Strontium Atomic Clocks
Pertoldi, A., Jha, A., Hauge, J. M., Varming, P., Singh, Y., & Montague, P. B. (2024) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2024.sm2g.7
Пилипенко, С. В., Литвинов, Д. А., Zakhvatkin, M. V., & Filetkin, A. I. (2024) · Astronomicheskii Zhurnal · doi:10.31857/s0004629924030062
Литвинов, Д. А. (2024) · Письма в астрономический журнал Астрономия и космическая астрофизика · doi:10.31857/s0320010824090018
XU, 徐. Q.-F., WANG, 王. Y.-B., & CHANG, 常. H. (2024) · Acta Sinica Quantum Optica · doi:10.3788/jqo20243002.0201
Enhancing optical clocks: strontium lattice clock with a record precision and accuracy
Kim, K., Aeppli, A., Warfield, W., Safronova, M. S., & Ye, J. (2025) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.3053393
“7,8 We discuss the strategies to reduce the systematic uncertainties, including the black body radiation correction, density shift, Stark shifts and other factors.”
Self-citationCharacterization of cold atoms based on photoionization momentum spectra
吴, Z. 志. W., Ruan, S. N., Shen, Z., Liu, J., Yu, X., Chen, L., Zhu, B., 王, X. 新. W., & Jiang, Y. (2025) · Chinese Physics B · doi:10.1088/1674-1056/add00d
Clock laser noise constraining synchronous comparison of spin-squeezed optical clocks
Yu, D., Zhang, S., & Chen, J. (2025) · Physics Letters A · doi:10.1016/j.physleta.2025.130634
Metadata
- Authors
- Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Bothwell, Tobias
- ORCID
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2019-10-10
- Volume
- 56
- Issue
- 6
- Pages
- 065004
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2949469742
- Cited by
- 324
- References
- 49
- Citations by year
- 2026: 26 · 2025: 45 · 2024: 67 · 2023: 63 · 2022: 44 · 2021: 42 · 2020: 35 · 2019: 2
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Metrologia (publishedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion, cc-by-sa)
- Durham Research Online (Durham University) (acceptedVersion, cc-by-nc-nd)
- arXiv (Cornell University) (submittedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Funders
- National Science Foundation (1734006)
- Air Force Office of Scientific Research
- Defense Advanced Research Projects Agency
- National Institute of Standards and Technology
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, systematic uncertainties, clock stability, frequency ratio measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.