JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 50 of the 50 references it cites were found in a registry or an index.
Abstract
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical uncertainty compared to the previous strontium record set by the JILA SrII optical lattice clock at . This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to . A seven-fold improvement in clock stability, reaching for an averaging time in seconds, allows the clock to average to its systematic uncertainty in under 10 min. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the boulder area clock optical network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The atomic correction coefficient is well-known [49] and does not significantly contribute to the estimated uncertainty of 2 × 10 -18 .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65874-3 · Cited by 5,025 · cited 3×
“where the index j enumerates the different surfaces of the vacuum chamber surrounding the atoms and Fi→j is the exchange factor defined as the fraction of total energy emitted by surface i that is absorbed by surface j directly or by reflection [21].”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560 · cited 1×
“Indeed, the JILA SrI clock has already been used in an atom cavity frequency intercomparison which highlights the long term stability of cryogenic crystalline cavities for timescales applications [37] and the search for timevariation of funda mental constants [38].”
MethodAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 10×
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [1, 2, 30] Sr OLCs.”
BackgroundMethodInfluentialSelf-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 14×
“Similarly, the range for β is chosen to encompass the weighted mean of values from published literature [2, 29, 25] to one which is consistent with what is observed in Fig.”
BackgroundMethodResultInfluentialSelf-citationInverse Radiative Heat Transfer
Modest, M. F. (2013) · Radiative Heat Transfer · doi:10.1016/b978-0-12-386944-9.50023-6 · Cited by 741
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
Background(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711 · cited 1×
“This surpasses the uncertainty record for a strontium optical lattice clock and places this clock among the most accurate clocks in the world [2, 4, 6].”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 2×
“Atomic clocks based on optical transitions have realized unprecedented levels of stability, reproducibility, and accuracy [1, 2, 3, 4, 5, 6].”
Background1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566 · cited 1×
“For narrow line spectroscopy, Doppler shifts between the clock laser and atoms trapped in the optical lattice are elimi nated by active optical path length stabilization [34].”
BackgroundSelf-citationHunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475 · cited 4×
“By alternately probing the two stretched states, we can reject fluctuations in the first-order Zeeman shift arising from magnetic field noise, further details of which are offered in [17].”
BackgroundInfluentialSelf-citationA Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384 · cited 1×
“Consequently, a frequency comparison of the SrI clock against a stable reference (the JILA 3D clock [18]), figure 2(c), can average well into the 10−19 decade without systematic effects impacting the clock stability.”
BackgroundSelf-citationSpectroscopic observation of SU( N )-symmetric interactions in Sr orbital magnetism
Zhang, X., Bishof, M., Bromley, S. L., Kraus, C. V., Safronova, M. S., Zoller, P., Rey, A. M., & Ye, J. (2014) · Science · doi:10.1126/science.1254978 · Cited by 370
Self-citationNew Limits on Coupling of Fundamental Constants to Gravity UsingSr87Optical Lattice Clocks
Blatt, S., Ludlow, A. D., Campbell, G. K., Thomsen, J. W., Zelevinsky, T., Boyd, M. M., Ye, J., Baillard, X., Fouché, M., Le Targat, R., et al. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.140801 · Cited by 333 · cited 1×
“This has enabled their use in a variety of applications ranging from the proposed redefinition of the SI second [7, 8, 9], to searches for variations of fundamental constants [10, 11, 12, 13], and increased capabilities for positioning, navigation, and timing applications [14].”
BackgroundSelf-citationOptical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
A Quantum Many-Body Spin System in an Optical Lattice Clock
Martin, M. J., Bishof, M., Swallows, M. D., Zhang, X., Benko, C., von-Stecher, J., Gorshkov, A. V., Rey, A. M., & Ye, J. (2013) · Science · doi:10.1126/science.1236929 · Cited by 196 · cited 3×
“Care is taken to ensure that, at the highest atom numbers, the spectroscopic lineshape remains Fourierlimited with high peak excitation fraction unblocked by a many-body excitation gap [22].”
BackgroundInfluentialSelf-citationRabi spectroscopy and excitation inhomogeneity in a one-dimensional optical lattice clock
Blatt, S., Thomsen, J. W., Campbell, G. K., Ludlow, A. D., Swallows, M. D., Martin, M. J., Boyd, M. M., & Ye, J. (2009) · Physical Review A · doi:10.1103/physreva.80.052703 · Cited by 167 · cited 1×
“The axial and radial mode occupation numbers are derived from carrier sideband asymmetry measurements, radial trapping frequencies, and transverse clock spectroscopy [49].”
MethodSelf-citationSynchronization of Distant Optical Clocks at the Femtosecond Level
Deschênes, J.-D., Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Bergeron, H., Cermak, M., Coddington, I., & Newbury, N. R. (2016) · Physical Review X · doi:10.1103/physrevx.6.021016 · Cited by 164 · cited 1×
“This has enabled their use in a variety of applications ranging from the proposed redefinition of the SI second [7, 8, 9], to searches for variations of fundamental constants [10, 11, 12, 13], and increased capabilities for positioning, navigation, and timing applications [14].”
BackgroundHigh Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154 · cited 1×
“13023(6) Hz [19], νdyn = −148.”
The absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 151 · cited 9×
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [1, 2, 30] Sr OLCs.”
MethodInfluentialSelf-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149 · cited 1×
“While it is possible to evaluate the systematic uncertainty of optical clocks at this level, active control of all systematics is now urgently needed [15, 16] to realize a robust optical frequency reference that maintains this level of uncertainty over long time periods.”
BackgroundSearch for domain wall dark matter with atomic clocks on board global positioning system satellites
Roberts, B. M., Blewitt, G., Dailey, C., Murphy, M., Pospelov, M., Rollings, A., Sherman, J., Williams, W., & Derevianko, A. (2017) · Nature Communications · doi:10.1038/s41467-017-01440-4 · Cited by 143
Blackbody-radiation shift in the Sr optical atomic clock
Safronova, M. S., Porsev, S. G., Safronova, U. I., Kozlov, M. G., & Clark, C. W. (2013) · Physical Review A · doi:10.1103/physreva.87.012509 · Cited by 140 · cited 3×
“The in-vacuum thermal probe consists of a 60 cm evacuated glass tube with a calibrated (±1.4 mK) PT100 sensor epoxied at the end.”
BackgroundInfluentialAtomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137 · cited 1×
“In the Yb OLC at NIST an in-vacuum radiation shield was characterized using precision thermometry and thermal modeling [20].”
MethodLattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the10−17Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137 · cited 4×
“The SYRTE collaboration recently measured a background gas collisional shift of (−3.0 ± 0.3) × 10−17/τ for a hydrogen-limited vacuum lifetime τ [32].”
MethodResultInfluentialThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129 · cited 2×
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [30, 1, 2] Sr OLCs.”
BackgroundMethodExperimental constraint on dark matter detection with optical atomic clocks
Wcisło, P., Morzyński, P., Bober, M., Cygan, A., Lisak, D., Ciuryło, R., & Zawada, M. (2016) · Nature Astronomy · doi:10.1038/s41550-016-0009 · Cited by 116 · cited 1×
“This has enabled their use in a variety of applications ranging from the proposed redefinition of the SI second [7, 8, 9], to searches for variations of fundamental constants [10, 11, 12, 13], and increased capabilities for positioning, navigation, and timing applications [14].”
BackgroundOperational Magic Intensity for Sr Optical Lattice Clocks
Ushijima, I., Takamoto, M., & Katori, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.263202 · Cited by 111 · cited 4×
“To constrain the lattice Stark shift at the 10−18 level, recent work has highlighted the importance of accounting for higher-order effects such as hyperpolarizability and the magnetic dipole and electric quadrupole terms [25, 26].”
BackgroundMethodResultInfluentialOptical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101 · cited 3×
“At NIST, the Yb clock group [27] demonstrated that in a system where the spatial modes have certain scalings with trap depth the lattice light shifts can be well characterized by a socalled thermal model, containing effective terms that are linear (α∗) and quadratic (β∗) in U:”
BackgroundMethodInfluentialOptical clock intercomparison with $6\times 10^{-19}$ precision in one hour
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1902.02741 · Cited by 98
Self-citationDemonstration of a Timescale Based on a Stable Optical Carrier
Milner, W. R., Robinson, J. M., Kennedy, C. J., Bothwell, T., Kedar, D., Matei, D. G., Legero, T., Sterr, U., Riehle, F., Leopardi, H., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.173201 · Cited by 82 · cited 1×
“Indeed, the JILA SrI clock has already been used in an atom-cavity frequency intercomparison which highlights the long term stability of cryogenic crystalline cavities for timescales applications [36] and the search for time-variation of fundamental constants [13].”
MethodSelf-citationLifetime Measurement of theP23Metastable State of Strontium Atoms
Yasuda, M., & Katori, H. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.153004 · Cited by 74 · cited 1×
“1(2) s after correcting for BBR-induced decay [33].”
BackgroundMeasurement of Thermal Radiation Properties of Solids
Richmond, J. C. (1963) · NASA STI Repository (National Aeronautics and Space Administration) · Cited by 70
Delivering pulsed and phase stable light to atoms of an optical clock
Falke, S., Misera, M., Sterr, U., & Lisdat, C. (2012) · Applied Physics B · doi:10.1007/s00340-012-4952-6 · Cited by 57 · cited 1×
“Eliminating sensitivity to these transients removes a potential source of systematic frequency offsets [35].”
BackgroundEffects of surface condition on the infrared absorptivity of 304 stainless steel
Wieting, T. J., & DeRosa, J. L. (1979) · Journal of Applied Physics · doi:10.1063/1.326083 · Cited by 50 · cited 1×
“08 [38, 39] Sapphire 0.”
Effect of Surface Roughness on the Total Hemispherical and Specular Reflectance of Metallic Surfaces
BIRKEBAK, R. C., Sparrow, E. M., Eckert, E. R. G., & Ramsey, J. W. (1964) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.3687093 · Cited by 49 · cited 1×
“Table 5: Specular steel reflectivities based on [42]”
BackgroundOperating a 87Sr optical lattice clock with high precision and at high density
Swallows, M. D., Martin, M. J., Bishof, M., Benko, C., Lin, Y., Blatt, S., Rey, A. M., & Ye, J. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2210 · Cited by 46 · cited 1×
“Finally, by verifying that the radial and axial trap frequencies in the lattice scale with trap depth as expected for a thermal gas, we confirm the shift scaling of ∆νdensity ∝ U as reported in [24].”
MethodSelf-citationThe Total Emissivity of Various Materials at 100–500°C
Barnes, B. T., Forsythe, W. E., & Adams, E. Q. (1947) · Journal of the Optical Society of America · doi:10.1364/josa.37.000804 · Cited by 45
A low maintenance Sr optical lattice clock
Hill, I. R., Hobson, R., Bowden, W., Bridge, E. M., Donnellan, S., Curtis, E. A., & Gill, P. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012019 · Cited by 37 · cited 1×
“While it is possible to evaluate the systematic uncertainty of optical clocks at this level, active control of all systematics is now urgently needed [15, 16] to realize a robust optical frequency reference that maintains this level of uncertainty over long time periods.”
BackgroundModeling light shifts in optical lattice clocks
Nemitz, N., Jørgensen, A. A., Yanagimoto, R., Bregolin, F., & Katori, H. (2019) · Physical Review A · doi:10.1103/physreva.99.033424 · Cited by 34 · cited 1×
“Recent work [46] has highlighted this importance by illustrating that different methods of preparing the atomic sample can result in different measurement values of β in Yb.”
BackgroundMultipolar Polarizabilities and Hyperpolarizabilities in the Sr Optical Lattice Clock
Porsev, S. G., Safronova, M. S., Safronova, U. I., & Kozlov, M. G. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.063204 · Cited by 32 · cited 2×
“To constrain the lattice Stark shift at the 10−18 level, recent work has highlighted the importance of accounting for higherorder effects such as hyperpolarizability and the magnetic dipole and electric quadrupole terms [25, 26].”
BackgroundTotal Hemispherical Emissivity of Sapphire
Wittenberg, A. M. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.000432 · Cited by 29 · cited 1×
“54 [40] Oven nozzle 0.”
Dispersion and polarization interactions of the strontium atom
Mitroy, J., & Zhang, J. Y. (2010) · Molecular Physics · doi:10.1080/00268976.2010.501766 · Cited by 28
A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2017) · Metrologia · doi:10.1088/1681-7575/aa765c · Cited by 19
Lattice Induced Frequency Shifts in Sr Optical Lattice Clocks at the $10^{-17}$ Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · HAL · Cited by 16
Thermodynamic analysis and experimental study of the effect of atmospheric pressure on the ice point
Harvey, A. H., McLinden, M. O., & Tew, W. L. (2013) · AIP conference proceedings · doi:10.1063/1.4819543 · Cited by 9 · cited 1×
“The 2 mK offset from 0 ◦C in our ice point cell is a consequence of performing our calibration measurements at an elevation of 1650 m above sea level [45].”
BackgroundSelf-citationMeasurement of Thermal Radiation Properties of Solids. NASA SP-31
Richmond, J. C. (1963) · Cited by 9
Calibration of Thin-Film Platinum Sensors for Use in the JILA Sr II Clock
Tew, W. L., Nicholson, T., & Huston, R. B. (2015) · doi:10.6028/nist.ir.8046 · Cited by 5 · cited 2×
“3 mK is included in the minor errors [46].”
BackgroundSelf-citation
Research works printed but not linked: 2
- [32] B. X. R. Alves, Y. Foucault, G. Vallet, R. L. Targat, and J. Lodewyck, 'Background collisional shift on lattice-trapped strontium atoms,' EFTF Conference Proceedings , 2019. -
- [37] American Society of Heating, Refrigerating and Air-Conditioning Engineers, 'Fundamentals, IP edition,' American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc , pp. 1-1, 2009. -
Cited by
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Self-citationFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationRoadmap on Atomtronics: State of the art and perspective
Amico, L., Boshier, M., Birkl, G., Minguzzi, A., Miniatura, C., Kwek, L.-C., Aghamalyan, D., Ahufinger, V., Anderson, D., Andrei, N., et al. (2021) · AVS Quantum Science · doi:10.1116/5.0026178 · Cited by 214
Kennedy, C. J., Oelker, E., Robinson, J. M., Bothwell, T., Kedar, D., Milner, W. R., Marti, G. E., Derevianko, A., & Ye, J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.201302 · Cited by 219
Self-citation
Metadata
- Authors
- Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Bothwell, Tobias
- ORCID
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2019-10-10
- Volume
- 56
- Issue
- 6
- Pages
- 065004
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2949469742
- Cited by
- 324
- References
- 49
- Citations by year
- 2026: 26 · 2025: 45 · 2024: 67 · 2023: 63 · 2022: 44 · 2021: 42 · 2020: 35 · 2019: 2
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Metrologia (publishedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion, cc-by-sa)
- Durham Research Online (Durham University) (acceptedVersion, cc-by-nc-nd)
- arXiv (Cornell University) (submittedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Funders
- National Science Foundation (1734006)
- Air Force Office of Scientific Research
- Defense Advanced Research Projects Agency
- National Institute of Standards and Technology
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, systematic uncertainties, clock stability, frequency ratio measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.