A high-density carbon fiber neural recording array technology
Open accessPublished version of a preprint
The DOI matches its Crossref record; 43 of the 45 references it cites were found in a registry or an index.
Abstract
Objective . Microwire and Utah-style neural recording arrays are the predominant devices used for cortical neural recording, but the implanted electrodes cause a significant adverse biological response and suffer from well-studied performance degradation. Recent work has demonstrated that carbon fiber electrodes do not elicit this same adverse response, but these existing designs are not practically scalable to hundreds or thousands of recording sites. We present technology that overcomes these issues while additionally providing fine electrode pitch for spatial oversampling. Approach . We present a 32-channel carbon fiber monofilament-based intracortical neural recording array fabricated through a combination of bulk silicon microfabrication processing and microassembly. This device represents the first truly two-dimensional carbon fiber neural recording array. The density, channel count, and size scale of this array are enabled by an out-of-plane microassembly technique in which individual fibers are inserted through metallized and isotropically conductive adhesive-filled holes in an oxide-passivated microfabricated silicon substrate. Main results . Five-micron diameter fibers are spaced at a pitch of 38 microns, four times denser than state of the art one-dimensional arrays. The fine diameter of the carbon fibers affords both minimal cross-section and nearly three orders of magnitude greater lateral compliance than standard tungsten microwires. Typical impedances are on the order of hundreds of kiloohms, and successful in vivo recording is demonstrated in the motor cortex of a rat. 22 total units are recorded on 20 channels, with unit SNR ranging from 1.4 to 8.0. Significance . This is the highest density microwire-style electrode array to date, and this fabrication technique is scalable to a larger number of electrodes and allows for the potential future integration of microelectronics. Large-scale carbon fiber neural recording arrays are a promising technology for reducing the inflammatory response and increasing the information density, particularly in neural recording applications where microwire arrays are already used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [339]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · cited 2×
“8 μm carbon fiber to a radius of 500 μm [20].”
BackgroundFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Armstrong-James, M., & Millar, J. (1979) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(79)90039-6 · Cited by 382
Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animals
Clark, J. J., Sandberg, S. G., Wanat, M. J., Gan, J. O., Horne, E. A., Hart, A. S., Akers, C. A., Parker, J. G., Willuhn, I., Martinez, V., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1412 · Cited by 378
Clinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343
A realistic brain tissue phantom for intraparenchymal infusion studies
Chen, Z.-J., Gillies, G. T., Broaddus, W. C., Prabhu, S. S., Fillmore, H., Mitchell, R. M., Corwin, F. D., & Fatouros, P. P. (2004) · Journal of Neurosurgery · doi:10.3171/jns.2004.101.2.0314 · Cited by 322
A porous metal-organic framework with ultrahigh acetylene uptake capacity under ambient conditions
Pang, J., Jiang, F., Wu, M., Liu, C., Su, K., Lu, W., Yuan, D., & Hong, M. (2015) · Nature Communications · doi:10.1038/ncomms8575 · Cited by 316
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
CLARK, R. S. B., SCHIDING, J. K., KACZOROWSKI, S. L., MARION, D. W., & KOCHANEK, P. M. (1994) · Journal of Neurotrauma · doi:10.1089/neu.1994.11.499 · Cited by 291
Impedance sensing device enables early detection of pressure ulcers in vivo
Swisher, S. L., Lin, M. C., Liao, A., Leeflang, E. J., Khan, Y., Pavinatto, F. J., Mann, K., Naujokas, A., Young, D., Roy, S., et al. (2015) · Nature Communications · doi:10.1038/ncomms7575 · Cited by 235
Self-citationA carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224
Kozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Chronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y.-T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 213
Close-Packed Silicon Microelectrodes for Scalable Spatially Oversampled Neural Recording
Scholvin, J., Kinney, J. P., Bernstein, J. G., Moore-Kochlacs, C., Kopell, N., Fonstad, C. G., & Boyden, E. S. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406113 · Cited by 208
Lee, M.-C. M., & Wu, M. C. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859092 · Cited by 201
Fast Electrically Switchable Capillary Effects
Welters, W. J. J., & Fokkink, L. G. J. (1998) · Langmuir · doi:10.1021/la971153b · Cited by 184
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Model-based analysis of cortical recording with silicon microelectrodes
Moffitt, M. A., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.05.018 · Cited by 170
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 162
Indwelling Neural Implants: Strategies for Contending with the In Vivo Environment
(2007) · CRC Press eBooks · doi:10.1201/9781420009309 · Cited by 129
Chen, Y., Lai, H.-Y., Lin, S.-H., Chao, W.-H., Chao, W.-H., Liao, C., Tsang, S., Chen, Y., & Lin, S.-Y. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.010 · Cited by 122
Franke, F., Jäckel, D., Dragas, J., Müller, J., Radivojević, M., Bakkum, D. J., & Hierlemann, A. R. (2012) · Frontiers in Neural Circuits · doi:10.3389/fncir.2012.00105 · Cited by 115
A high performance 180 nm generation logic technology
Yang, S., Ahmed, S., Arcot, B., Arghavani, R., Bai, P., Chambers, S., Charvat, P. K., Cotner, R., Gasser, R. A., Ghani, T., et al. (2002) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.1998.746320 · Cited by 87
Interaction of macrophages with fibrous materials in vitro
Bernatchez, S. F., Parks, P. J., & Gibbons, D. F. (1996) · Biomaterials · doi:10.1016/0142-9612(96)00014-2 · Cited by 69
A silicon carbide array for electrocorticography and peripheral nerve recording
Diaz-Botia, C. A., Luna, L. E., Neely, R. M., Chamanzar, M., Carraro, C., Carmena, J. M., Sabes, P. N., Maboudian, R., & Maharbiz, M. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7698 · Cited by 61
Self-citationCarbon fiber on polyimide ultra-microelectrodes
Gillis, W. F., Lissandrello, C. A., Shen, J., Pearre, B. W., Mertiri, A., Deku, F., Cogan, S., Holinski, B. J., Chew, D. J., White, A. E., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8c88 · Cited by 55
High aspect ratio deep silicon etching
Owen, K. J., VanDerElzen, B., Peterson, R. L., & Najafi, K. (2012) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2012.6170138 · Cited by 52
Mechanically Similar Gel Simulants for Brain Tissues
Pervin, F., & Chen, W. W. (2011) · Conference proceedings of the Society for Experimental Mechanics · doi:10.1007/978-1-4419-8228-5_3 · Cited by 48
Chen, C. H., McCullagh, E. A., Pun, S. H., Mak, P. U., Vai, M. I., Mak, P., Klug, A., & Lei, T. C. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609412 · Cited by 47
Burke, M., Blake, A., Povey, I. M., Schmidt, M. T., Petkov, N., Carolan, P. B., & Quinn, A. J. (2014) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.4868215 · Cited by 31
ELECTRICAL CONDUCTION MODELS FOR ISOTROPICALLY CONDUCTIVE ADHESIVES
Li, L., & Morris, J. E. (1995) · Journal of Electronics Manufacturing · doi:10.1142/s096031319500030x · Cited by 23
Extracellular potential fields of single PT-neurons
Rosenthal, F. (1972) · Brain Research · doi:10.1016/0006-8993(72)90733-0 · Cited by 14
Open-source automated system for assembling a high-density microwire neural recording array
Massey, T. L., Lee, J. H., Ray, M., Sathe, N., Liu, X., Pister, K. S. J., & Maharbiz, M. M. (2016) · International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS) · doi:10.1109/marss.2016.7561750 · Cited by 9
Self-citation(2000) · doi:10.1002/1097-4636(200010)52:1<231::aid-jbm29>3.0.co;2-e
Research works printed but not linked: 2
- Patel, 2016, Chronic in vivo stability assessment of carbon fiber microelectrode arrays, J. Neural Eng., 13, 10.1088/1741-2560/13/6/066002 · DOI · Paper page
- Deepthi, 2010, Rheometric studies on agarose gel-a brain mimic material, SASTECH Journal, 9, 27
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
The Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 160
Self-citation
Metadata
- Authors
- Massey, T. L., Santacruz, S. R., Hou, J. F., Pister, K. S. J., Carmena, J. M., & Maharbiz, M. M.
- Affiliations
- University of California, Berkeley (US)
- Chan Zuckerberg Biohub San Francisco (US)
- Corresponding author
- Maharbiz, Michel M
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2019-01-09
- Volume
- 16
- Issue
- 1
- Pages
- 016024
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2951697899
- Cited by
- 58
- References
- 45
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 9 · 2023: 7 · 2022: 2 · 2021: 15 · 2020: 12 · 2019: 6
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (HR0011728043)
- National Eye Institute (R21 EY027570)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- carbon fiber electrodes, intracortical recording, high-density electrode arrays, silicon micromachining, electrode pitch, in vivo neural recording, electrode impedance, inflammation
- MeSH terms
- Carbon Fiber, Action Potentials, Cerebral Cortex, Electrodes, Implanted, Humans, Microelectrodes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.