The very large electrode array for retinal stimulation (VLARS)—A concept study
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objective. The restoration of vision in blind patients suffering from degenerative retinal diseases like retinitis pigmentosa may be obtained by local electrical stimulation with retinal implants. In this study, a very large electrode array for retinal stimulation (VLARS) was introduced and tested regarding its safety in implantation and biocompatibility. Further, the array’s stimulation capabilities were tested in an acute setting. Approach. The polyimide-based implants have a diameter of 12 mm, cover approximately 110 mm 2 of the retinal surface and carrying 250 iridium oxide coated gold electrodes. The implantation surgery was established in cadaveric porcine eyes. To analyze biocompatibility, ten rabbits were implanted with the VLARS device, and observed for 12 weeks using slit lamp examination, fundus photography, optical coherence tomography (OCT) as well as ultrasound imaging. After enucleation, histological examinations were performed. In acute stimulation experiments, electrodes recorded cortical field potentials upon retinal stimulation in the visual cortex in rabbits. Main results. Implantation studies in rabbits showed that the implantation surgery is safe but difficult. Retinal detachment induced by retinal tears was observed in five animals in varying severity. In five cases, corneal edema reduced the quality of the follow-up examinations. Findings in OCT-imaging and funduscopy suggested that peripheral fixation was insufficient in various animals. Results of the acute stimulation demonstrated the array’s ability to elicit cortical responses. Significance. Overall, it was possible to implant very large epiretinal arrays. On retinal stimulation with the VLARS responses in the visual cortex were recorded. The VLARS device offers the opportunity to restore a much larger field of visual perception when compared to current available retinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · cited 2×
“Especially the Alpha-IMS surpasses other approaches of prosthetic vision in terms of sheer electrode number by a large margin with 1500 individual electrodes, yet ultimately creating a 38 × 40 pixel matrix granting a visual angle of 11° by 11° [30].”
BackgroundMethodFirst-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333 · cited 1×
“The highest accessible visual acuity of suprachoroidal systems seems significantly inferior to those shown in epiretinal and subretinal systems with an acuity of 20/4451 in the suprachoroidal system developed by Ayton et al versus 20/1262 in the epiretinal ARGUS II or even 20/200 in the subretinal alpha-IMS [20, 30, 3…”
BackgroundThe parameters of the porcine eyeball
Sanchez, I., Martin, R., Ussa, F., & Fernandez-Bueno, I. (2011) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1617-9 · Cited by 298 · cited 1×
“It is crucial to consider the different dimensions of the rabbit’s eye compared to those of humans, or pigs, on which prior implantation experiments were performed [17, 21, 22].”
BackgroundRetinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272 · cited 1×
“Thus, surpassing epiretinal systems in theoretical visual acuity, the size of subretinal systems is limited by the method of implantation [24, 32].”
BackgroundSimulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183 · cited 2×
“Sharing similar properties with the VLARS, the POLYRETINA is an approach introduced recently by Ferlauto et al [33].”
MethodRetinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Development of very large electrode arrays for epiretinal stimulation (VLARS)
Waschkowski, F., Hesse, S., Rieck, A. C., Lohmann, T., Brockmann, C., Laube, T., Bornfeld, N., Thumann, G., Walter, P., Mokwa, W., et al. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-11 · Cited by 43
Self-citation
Cited by
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
“On the other hand, the surgical fixation to the retina is another open challenge for wide epiretinal implants [124].”
BackgroundThorn, J. T., Migliorini, E., & Ghezzi, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb5bc · Cited by 34
“density in a small surface area[3] or enlarge the surface area at the expense of the pixel density[4,7,8].”
BackgroundPig models in retinal research and retinal disease
McCall, M. A. (2024) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a041296 · Cited by 21
Gaillet, V., Borda, E., Zollinger, E. G., & Ghezzi, D. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf523 · Cited by 10
Metadata
- Authors
- Lohmann, T. K., Haiss, F., Schaffrath, K., Schnitzler, A.-C., Waschkowski, F., Barz, C., van der Meer, A.-M., Werner, C., Johnen, S., Laube, T., Bornfeld, N., Mazinani, B. E., Rößler, G., Mokwa, W., & Walter, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2019-11-06
- Volume
- 16
- Issue
- 6
- Pages
- 066031
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2972184875
- Cited by
- 28
- References
- 10
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The very large electrode array for retinal stimulation (VLARS)—A concept study. https://app.cochat.ai/papers/10.1088/1741-2552/ab4113
- The paper
- Lohmann, T. K., Haiss, F., Schaffrath, K., Schnitzler, A.-C., Waschkowski, F., Barz, C., van der Meer, A.-M., Werner, C., Johnen, S., Laube, T., Bornfeld, N., Mazinani, B. E., Rößler, G., Mokwa, W., & Walter, P. (2019). The very large electrode array for retinal stimulation (VLARS)—A concept study. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ab4113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.