Compliant peripheral nerve interfaces.
Open accessThe DOI matches its Crossref record; 247 of the 253 references it cites were found in a registry or an index; none of the 3 sources its claims cite is checked for support yet.
Abstract
This paper reviews recent progress in the development of flexible and implantable PNIs, highlighting materials selection, fabrication methods, and interface designs.
Overview
CoChat Summary
TL;DR
This topical review surveys recent progress in mechanically compliant peripheral nerve interfaces (PNIs), focusing on materials, fabrication, and integrated functions for flexible implantable systems. It argues that long-term PNI performance is limited by implant–tissue damage and foreign body response, and that compliance is a key strategy to improve chronic function.
Key findings
- PNIs are used for both research and therapy, including closed-loop control of neuroprosthetic limbs, treatment of neuropathic pain, and restoration of functions such as breathing and bladder management.
- The review highlights three main interface classes: intraneural, extraneural, and regenerative, and three modulation modalities: electrical, optical, and chemical.
- A central challenge is that implantable PNIs can provide enhanced selectivity over non-invasive approaches, but their long-term functionality is limited by tissue damage at the implant–tissue interface.
- The paper emphasizes that compliant PNIs are designed to match nerve anatomy and dynamic motion in order to limit foreign body response.
Methods
- Topical review article: the paper synthesizes recent literature rather than reporting a new experimental study.
- Scope of the review covers flexible and implantable PNIs, with attention to materials selection, fabrication methods, integrated functions, and interface design categories.
- Main analysis is qualitative and comparative, discussing design trade-offs and challenges in integrating PNIs on compliant substrates.
Limitations
- The paper does not present original experimental data or a quantitative meta-analysis; this is evident from the text as a review article.
- It states that long-term functionality remains limited by tissue damage and implant–tissue interface issues, indicating an unresolved design limitation.
- The text makes clear that integrating electrical, optical, and chemical functions on compliant substrates remains challenging.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 2 Not valid · 2 Not checked · 5 Own results and interpretations
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Nevertheless, the long-term functionality of implantable PNIs is limited by tissue damage, which occurs at the implant–tissue interface”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“challenging to capture following PN injury [15, 16]”
What the sources say
- Not checked yetcites [15] Navarro, 1998, Stimulation and recording from regenerated peripheral nerves through polyimide sieve electrodes, J. Peripher. Nerv. Syst.
- Not checked — no full text of the sourcecites [16] Dario, 1998, Neural interfaces for regenerated nerve stimulation and recording, IEEE Trans. Rehabil. Eng. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
1 reference still to check
A free account verifies the references that are still open.
- Probably not a substantial claim. 7
- It may state two separate claims as one. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Neuromodulation of the autonomic nerves, which regulates non-volitional bodily processes such as those of the cardiovascular, gastrointestinal, and immune systems, has shown therapeutic benefits in diseases including heart failure, lung injury, inflammation, rheumatoid arthritis, obesity, and diabetes [11], [12].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Recently, interfascicular interfaces were called the 'least common in literature' [47].”
From Directed stimulation with interfascicular interfaces for peripheral nerve stimulation (2021) · cites this paper as [47]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Patientspecific methods of addressing the peripheral nerves require close inspection of neural activity to optimise the position of electrodes [12], the stimulation algorithm, and analysis methods of neural activity according to the individual needs of patients [218].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This improves longevity by addressing interface compromising factors such as the foreign body reaction, which can deteriorate the neural interface and isolate the nerve fibers through scarring [12], [206].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [12]
Experimental — accuracy not yet measured
Citations
Cites
Items 201–247 of 247
Selective Nerve Cuff Stimulation Strategies for Prolonging Muscle Output
Gelenitis, K., Sanner, B. M., Triolo, R. J., & Tyler, D. J. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2937061 · Cited by 20 · cited 1×
“Neural Interface 23 754–62 [102] Gelenitis K T, Sanner B M, Triolo R J and Tyler D J 2020 Selective nerve cuff stimulation strategies for prolonging muscle output IEEE Trans.”
BackgroundDelianides, C., Tyler, D., Pinault, G., Ansari, R., & Triolo, R. (2020) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.13110 · Cited by 20
Kim, H., Dingle, A. M., Ness, J. P., Baek, D.-H., Bong, J., Lee, I. K., Shulzhenko, N. O., Zeng, W., Israel, J. S., Pisaniello, J. A., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108602 · Cited by 19 · cited 3×
“16 066040 [131] Kim H et al 2020 Cuff and sieve electrode (CASE): the combination of neural electrodes for bi-directional peripheral nerve interfacing J.”
BackgroundInfluentialA novel microwire interface for small diameter peripheral nerves in a chronic, awake murine model
Falcone, J., Liu, T., Goldman, L., Pogue David, D., Rieth, L. W., Bouton, C. E., Straka, M., & Sohal, H. S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9b6d · Cited by 19
Bingham, J. R., Kniery, K. R., Jorstad, N. L., et al. (2019) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2019.03.009 · Cited by 18
Desai, V. H., Spearman, B. S., Shafor, C. S., Natt, S., Teem, B., Graham, J. B., Atkinson, E. W., Wachs, R. A., Nunamaker, E. A., Otto, K. J., et al. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008326 · Cited by 17 · cited 3×
“Similarly, other silicone-based extraneural interfaces, such as the FINE electrodes developed at Case Western Reserve University, have been implanted for up to 6 years restoring naturalistic sensation in upper limb amputees [103].”
BackgroundKim, H., Heo, D. N., Lee, Y. J., Lee, S. J., Kang, J. Y., Lee, S. H., Kwon, I. K., & Hee, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-15551-x · Cited by 17
Alvey, L. M., Jones, J. F. X., Tobin-O'Brien, C., & Pickering, M. (2018) · Journal of Anatomy · doi:10.1111/joa.12910 · Cited by 17 · cited 2×
“1 16063 [21] Alvey L M, Jones J F X, Tobin-O’Brien C and Pickering M 2019 Bands of Fontana are caused exclusively by the sinusoidal path of axons in peripheral nerves and predict axon path; evidence from rodent nerves and physical models J.”
BackgroundA Quantitative Investigation on the Peripheral Nerve Response within the Small Strain Range
Giannessi, E., Stornelli, M. R., Coli, A., & Sergi, P. N. (2019) · Applied Sciences · doi:10.3390/app9061115 · Cited by 17 · cited 3×
“We believe further efforts are needed to better quantify the biomechanics of the nerve, especially given its structural (endoneurium, perineurium, epineurium, whole fascicles and nerves) heterogeneity [56, 60], and the variety of interface approaches (cuff vs penetrating).”
BackgroundMiniature electroparticle-cuff for wireless peripheral neuromodulation
Hernandez-Reynoso, A. G., Nandam, S., O’Brien, J. M., Kanneganti, A., Cogan, S. F., Freeman, D. K., & Romero‐Ortega, M. I. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab1c36 · Cited by 17 · cited 1×
“[224] Hernandez-Reynoso A G, Nandam S, O’Brien J M,”
Mechanical considerations for design and implementation of peripheral intraneural devices
Stiller, A. M., González‐González, M. A., Boothby, J. M., Sherman, S., Benavides, J., Romero‐Ortega, M. I., Pancrazio, J. J., & Black, B. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4114 · Cited by 17
Recovering Motor Activation with Chronic Peripheral Nerve Computer Interface
Eggers, T. E., Dweiri, Y. M., McCallum, G. A., & Durand, D. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-32357-7 · Cited by 16 · cited 1×
“[40] Eggers T E, Dweiri Y M, McCallum G A and Durand D M”
BackgroundHarreby, K. R., Kundu, A., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2015) · Artificial Organs · doi:10.1111/aor.12347 · Cited by 15 · cited 1×
“17 24 [83] Harreby K R, Kundu A, Yoshida K, Boretius T, Stieglitz T and Jensen W 2015 Subchronic stimulation performance of transverse intrafascicular multichannel electrodes in the median nerve of the Göttingen minipig: transverse intrafascicular multichannel electrodes Artif.”
BackgroundA fully implanted drug delivery system for peripheral nerve blocks in behaving animals
Pohlmeyer, E. A., Jordon, L. R., Kim, P., & Miller, L. E. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.006 · Cited by 15 · cited 3×
“In the case of pharmacological nerve block, syringe injections can be especially complicated as animals need to be restrained and small movements during the procedure can cause damage to the nerve [152].”
BackgroundSabetian, P., Sadeghlo, B., Zhang, C. H., & Yoo, P. B. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.11.010 · Cited by 15 · cited 3×
“For example, FEM models have shown the effect of different electrode configurations and recording modalities on the reduction of artifacts derived from external sources such as muscles [72, 73].”
BackgroundAn ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15 · cited 2×
“[129] Lancashire H T, Jiang D, Demosthenous A and Donaldson”
BackgroundSimulation of impedance changes with a FEM model of a myelinated nerve fibre
Tarotin, I., Aristovich, K. Y., & Holder, D. S. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2d1c · Cited by 15 · cited 2×
“center longitudinal study of 143 patients Seizure 22 827–33 [93] Tarotin I, Aristovich K and Holder D 2019 Simulation of impedance changes with a FEM model of a myelinated nerve fibre J.”
BackgroundStrain stiffening of peripheral nerves subjected to longitudinal extensions in vitro
Giannessi, E., Stornelli, M. R., & Sergi, P. N. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.10.012 · Cited by 15 · cited 2×
“We believe further efforts are needed to better quantify the biomechanics of the nerve, especially given its structural (endoneurium, perineurium, epineurium, whole fascicles and nerves) heterogeneity [56, 60], and the variety of interface approaches (cuff vs penetrating).”
BackgroundDiaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15 · cited 2×
“The first PNIs appeared in the late 1960s and consisted in simple lead wires or metal foils, insulated in silicone rubber, and were applied primarily to the phrenic nerve for diaphragm pacing [2, 10] and to sacral roots for bladder control [11, 12].”
BackgroundJeong, J., Jung, W., Kim, O., Chu, J.-U., Youn, I., Kim, K., Oh, S. R., Park, J. W., & Kim, J. (2016) · 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523786 · Cited by 14 · cited 2×
“12 016016 [119] Jeong J, Jung W, Kim O, Chu J-U, Youn I, Kim K, Oh S R, Park J W and Kim J 2016 64-channel double-layered sieve electrode with increased porosity for improved axon regeneration and high spatial resolution 2016 6th IEEE Int.”
BackgroundMethodRapeaux, A., Nikolić, K., Williams, I., Eftekhar, A., & Constandinou, T. G. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319125 · Cited by 13 · cited 2×
“[68] Rapeaux A, Nikolic K, Williams I, Eftekhar A and”
BackgroundMethodSELECTIVE STIMULATION OF PIG RADIAL NERVE: COMPARISON OF 12-POLAR AND 18-POLAR CUFF ELECTRODES
Schüettler, M., Riso, R. R., Dalmose, A. L., Stefania, D., & Stieglitz, T. (2002) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2002.47.s1b.696 · Cited by 12 · cited 1×
“26 161–4 [227] Schuettler M, Riso R R, Dalmose A, Stefania D and Stieglitz T 2002 Selective stimulation of pig radial nerve: comparison of 12-polar and 18-polar cuff electrodes Biomed.”
BackgroundFascial plane blocks: anatomical structures that affect the spread of local anesthetic
Hotta, K. (2019) · Journal of Anesthesia · doi:10.1007/s00540-019-02647-z · Cited by 12 · cited 2×
“However, it is difficult to contain the spread of local anaesthetic, which can target nearby muscles, causing unwanted motor block [190].”
BackgroundAn implantable nerve cooler for the exercising dog
Borgdorff, P., & Versteeg, P. (1984) · European Journal of Applied Physiology · doi:10.1007/bf00422583 · Cited by 11
Alfaifi, A., Alhomoudi, I. A., Nabki, F., et al. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2877736 · Cited by 11
Graham, R. S., Zachs, D. P., Cotero, V. E., D’Agostino, C. A., Ntiloudi, D., Kaiser, C. R. W., Graf, J. F., Wallace, K. D., Ramdeo, R., Coleman, T. R., et al. (2020) · medRxiv · doi:10.1101/2020.07.14.20153528 · Cited by 11 · cited 1×
“[148] Graham R S et al 2020 Calming the cytokine”
BackgroundAcquisition of bioelectrical signals with small electrodes
Viswam, V., Obien, M. E. J., Frey, U., Franke, F., & Hierlemann, A. R. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325216 · Cited by 10
Simulation of impedance changes with a FEM model of a myelinated nerve fibre
Tarotin, I., Aristovich, K., & Holder, D. (2019) · UCL Discovery (University College London) · Cited by 10
Motion control of the rabbit ankle joint with a flat interface nerve electrode
Park, H., & Durand, D. M. (2015) · Muscle & Nerve · doi:10.1002/mus.24654 · Cited by 9
Optical Stimulation and Electrophysiological Analysis of Regenerating Peripheral Axons
Ward, P. J., & ENGLISH, A. W. (2019) · BIO-PROTOCOL · doi:10.21769/bioprotoc.3281 · Cited by 9
Laser-fabrication of peripheral nerve cuff electrodes with integrated microfluidic channels
Schüettler, M., Schroeer, S., Ordonez, J. S., & Stieglitz, T. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910533 · Cited by 8 · cited 2×
“A common method for drug delivery in flexible chemical PNIs consists in fabricating microfluidic channels on cuff electrodes [173, 178, 186] which can then be connected to external syringe pumps [186] to provide pharmacological treatment over time.”
BackgroundMethodExploring selective neural electrical stimulation for upper limb function restoration
Tigra, W., Guiraud, D., Andreu, D., Coulet, B., Gélis, A., Fattal, C., Maciejasz, P., Picq, C. A., Rossel, O., Teissier, J., et al. (2016) · European Journal of Translational Myology · doi:10.4081/ejtm.2016.6035 · Cited by 8
Peripheral nerve recruitment curve using near-infrared stimulation
Dautrebande, M., Doguet, P., Gorza, S., Delbeke, J., & Nonclercq, A. (2018) · Optogenetics and Optical Manipulation · doi:10.1117/12.2288398 · Cited by 8 · cited 1×
“39 513–26 [162] Dautrebande M, Doguet P, Gorza S-P, Delbeke J and Nonclercq A 2018 Peripheral nerve recruitment curve using near-infrared stimulation Optogenetics and Optical Manipulation 2018 ed S K Mohanty, N V Thakor and E D”
MethodKawasaki, S., Giagka, V., de Haas, M., Louwerse, M. C., Henneken, V. A., van Heesch, C., & Dekker, R. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717064 · Cited by 8
Pfau, J., Ganatra, D., Weltin, A., Urban, G. A., Kieninger, J., & Stieglitz, T. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856621 · Cited by 8
NEURAL CUFF ELECTRODE RECORDINGS AS A REPLACEMENT OF LOST SENSORY FEEDBACK IN PARAPLEGIC PATIENTS
Sinkjær, T., Haugland, M. K., & Haase, J. (1993) · Elsevier eBooks · doi:10.1016/b978-0-444-89958-3.50018-8 · Cited by 7 · cited 1×
“[38] Sinkjaer T, Haugland M and Haase J 1993 Neural cuff”
BackgroundClark, G. A., Schister, S. L., Ledbetter, N. M., et al. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.907627 · Cited by 7
Ultra-compliant peripheral nerve cuff electrode with hydrogel adhesion
Ong, X. C., Huang, W.-C., Kwon, I. S., Gopinath, C., Wu, H., Fisher, L. E., Gaunt, R. A., Bettinger, C. J., & Fedder, G. K. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346566 · Cited by 6 · cited 3×
“The enhanced compliance of cuffs with hydrogel coatings allows for a more intimate contact between nerve and device [106, 107], which is crucial to guarantee an optimal electrical performance and to avoid cuff displacements.”
BackgroundMethodStimulation of peripheral nerves using conductive hydrogel electrodes
Gilmour, A. D., Goding, J. A., Robles, U. A. A., Staples, N. A., Byrnes‐Preston, P., Morley, J. W., Lovell, N. H., Chew, D. J., & Green, R. A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513628 · Cited by 5 · cited 2×
“[239] Gilmour A, Goding J, Robles U A, Staples N,”
BackgroundFreeberg, M. J. (2018) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
Batteryless Pelvic Nerve Direct Modulation for Bladder Voding Using an Active Neural Clip
Lee, S., Peh, W. Y. X., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2018) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2018.8556942 · Cited by 4
Layton, B. E., Sastry, A. M., Wang, H., & Sullivan, K. A. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1136890 · Cited by 3 · cited 2×
“43 MPa Tensile [52] Rat—sciatic Linear E = 13 MPa Tensile [53] Human—median Ogden μ= 19 kPa, α= 50, g = 0.”
BackgroundInvestigations on stability of implanted nervous thin-film electrodes
Čvančara, P., Boretius, T., & Stieglitz, T. (2014) · Annual Conference of the International Functional Electrical Stimulation Society (IFESS) · doi:10.1109/ifess.2014.7036747 · Cited by 3 · cited 1×
“89 094301 [80] Wurth S et al 2017 Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes Biomaterials 122 114–29 [81] Cvancara P, Boretius T and Stieglitz T 2014 Investigations on stability of implanted nervous thin-film electrodes 2014 IEEE 19th Int.”
BackgroundReversible vagal blockade in conscious rats using a targeted delivery device
Zheng, C., Kawada, T., Li, M., et al. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.02.015 · Cited by 2 · cited 2×
“Implantable drug delivery systems are promising approaches for local, chronic and repeatable pharmacological treatment using cuff-like devices incorporating a cannula [152, 191], without causing nerve trauma associated with intraneural injections [192].”
BackgroundMethodVagus Nerve Stimulation as a Strategy to Augment Auditory Rehabilitation
Engineer, C. T. (2019) · Brain stimulation · doi:10.1016/j.brs.2018.12.360 · Cited by 2
Burgess, J. D., Major, B. P., McNeel, C., et al. (2019) · Brain stimulation · doi:10.1016/j.brs.2018.12.361 · Cited by 1
Jeong (2000) · doi:10.1002/(sici)1097-4636(200005)50:2
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
“Although long-term nerve implants are feasible 103,114,195,231–234 and promising for versatile clinical and home uses 96,235 , their wider clinical translation will require substantial developments regarding device stability, their integration into fully implantable systems, and the modularity of…”
BackgroundSelf-citationBioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
“450 Poor control over cooling can pose the risk of cold nerve injury, underscoring the importance of achieving proper nerve integration.”
BackgroundHighly-stable, injectable, conductive hydrogel for chronic neuromodulation
Yang, M., Wang, L., Liu, W., Li, W., Huang, Y., Jin, Q., Zhang, L., Jiang, Y., & Luo, Z. (2024) · Nature Communications · doi:10.1038/s41467-024-52418-y · Cited by 143
Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces
Dong, C., Carnicer‐Lombarte, A., Bonafè, F., Huang, B., Middya, S., Jin, A. T., Tao, X., Han, S., Bance, M., Barone, D. G., et al. (2024) · Nature Materials · doi:10.1038/s41563-024-01886-0 · Cited by 133
“A mixed aqueous solution containing 0.1 M pyrrole and 0.1 M NaDBS was used as the electrolyte.”
InfluentialYang, M., Chen, P., Qu, X., Zhang, F., Ning, S., Ma, L., YANG, K. Y., Su, Y., Zang, J., Jiang, W., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c04606 · Cited by 109
Metadata
- Authors
- Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Scuola Superiore Sant'Anna (IT)
- Corresponding author
- Micera, Silvestro
- Lacour, Stéphanie P
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-03-08
- Volume
- 18
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3137684282
- Cited by
- 60
- References
- 253
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 16 · 2023: 11 · 2022: 14 · 2021: 5
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Fondation Bertarelli
- Horizon 2020 Framework Programme (NeuTouch 813713)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (CHRONOS)
- H2020 Marie Skłodowska-Curie Actions (754354)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- peripheral nerve interfaces, implantable neural interfaces, flexible electronics, biocompatibility, foreign body reaction, neural recording, neurostimulation, optical stimulation, chemical stimulation, implant-tissue interface, neuroprosthetics, neuropathic pain
- MeSH terms
- Neurosciences, Peripheral Nerves, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.