Intra-day signal instabilities affect decoding performance in an intracortical neural interface system
Open accessThe DOI matches its Crossref record; 66 of the 67 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Motor neural interface systems (NIS) aim to convert neural signals into motor prosthetic or assistive device control, allowing people with paralysis to regain movement or control over their immediate environment. Effector or prosthetic control can degrade if the relationship between recorded neural signals and intended motor behavior changes. Therefore, characterizing both biological and technological sources of signal variability is important for a reliable NIS. APPROACH: To address the frequency and causes of neural signal variability in a spike-based NIS, we analyzed within-day fluctuations in spiking activity and action potential amplitude recorded with silicon microelectrode arrays implanted in the motor cortex of three people with tetraplegia (BrainGate pilot clinical trial, IDE). MAIN RESULTS: 84% of the recorded units showed a statistically significant change in apparent firing rate (3.8 ± 8.71 Hz or 49% of the mean rate) across several-minute epochs of tasks performed on a single session, and 74% of the units showed a significant change in spike amplitude (3.7 ± 6.5 µV or 5.5% of mean spike amplitude). 40% of the recording sessions showed a significant correlation in the occurrence of amplitude changes across electrodes, suggesting array micro-movement. Despite the relatively frequent amplitude changes, only 15% of the observed within-day rate changes originated from recording artifacts such as spike amplitude change or electrical noise, while 85% of the rate changes most likely emerged from physiological mechanisms. Computer simulations confirmed that systematic rate changes of individual neurons could produce a directional 'bias' in the decoded neural cursor movements. Instability in apparent neuronal spike rates indeed yielded a directional bias in 56% of all performance assessments in participant cursor control (n = 2 participants, 108 and 20 assessments over two years), resulting in suboptimal performance in these sessions. SIGNIFICANCE: We anticipate that signal acquisition and decoding methods that can adapt to the reported instabilities will further improve the performance of intracortically-based NISs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the CNS, small signal amplitudes, signal instability, and signal loss over time are often observed.14,15”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This may undermine the detection and decoding efficacy of brain-machine interfaces and closed-loop neurostimulation applications in which the stimulus is conditioned on a recorded neural signal.1,15”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [15]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“any differences in average firing rates observed between two behaviors collected in separate blocks could be due to spurious drifts in firing rates known to occur across time63,64.”
From Inner speech in motor cortex and implications for speech neuroprostheses (2025) · cites this paper as [64]
The cited source says what the claim attributes to it.
In the citing paper
“While the ‘isolated ’verbal behavior experiments (section 3) allowed us to explore a large number of behaviors, it did not allow us to assess differences in neural representation between behaviors, because any differences between blocks could also be caused by spurious neural nonstationarity known to be occur in microelectrode array recordings63,64.”
From Inner speech in motor cortex and implications for speech neuroprostheses (2025) · cites this paper as [64]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 1×
“We used the Benjamini–Hochberg procedure (Benjamini and Hochberg 1995) with a correction for dependent statistics (Benjamini and Yekutieli 2001) to set the false discovery rate within a session at the level of 5% for all tests.”
The control of the false discovery rate in multiple testing under dependency
Benjamini, Y., & Yekutieli, D. (2001) · The Annals of Statistics · doi:10.1214/aos/1013699998 · Cited by 10,490 · cited 1×
“We used the Benjamini–Hochberg procedure (Benjamini and Hochberg 1995) with a correction for dependent statistics (Benjamini and Yekutieli 2001) to set the false discovery rate within a session at the level of 5% for all tests.”
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“…Taylor et al 2002, Lebedev et al 2005, Serruya et al 2002), in people with tetraplegia (Chadwick et al 2011, Kim et al 2008, Simeral et al 2011a, Hochberg et al 2006), or to perform actions with a robotic limb in macaques (Velliste et al 2008) or humans (Hochberg et al 2012, Collinger et al 2012).”
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409 · cited 1×
“…to control a computer cursor on a screen in intact macaques (Ganguly and Carmena 2009, Carmena et al 2003, Taylor et al 2002, Lebedev et al 2005, Serruya et al 2002), in people with tetraplegia (Chadwick et al 2011, Kim et al 2008, Simeral et al 2011a, Hochberg et al 2006), or to perform…”
BackgroundSelf-citationTruccolo, W., Eden, U. T., Fellows, M. R., Donoghue, J. P., & Brown, E. N. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00697.2004 · Cited by 1,049 · cited 1×
“Thus modeling the observed (Truccolo et al 2005, Wu and Hatsopoulos 2008) or hidden sources of variability (Stevenson et al 2010, Lawhern et al 2010, Wood et al 2005, Kulkarni and Paninski 2007) could provide further improvement in decoding performance.”
Self-citation
Research works printed but not linked: 3
- Homer ML, Perge JA, Hochberg LR. Mitigating nonstationarities during neural cursor control with noise offset correction. Society for Neuroscience Annual Meeting, 142.03/E18 2011 [Google Scholar]
- Nuyujukian P, Kao JC, Fan JM, Stavisky SD, Ryu S, Shenoy K. COSYNE. Salt Lake City, Utah: 2012. A high–performance, robust brain–machine interface without retraining. [Google Scholar]
- Simeral JD, Perge JA, Masse NY, Jarosiewicz B, Bacher D, Donoghue J, Hochberg LR. Some preliminary longitudinal findings from five trial participants using the BrainGate neural interface system. Society for Neuroscience. 2011b;41 [Google Scholar]
Cited by
Items 101–200 of 272
Nano functional neural interfaces
Wang, Y., Zhu, H., Yang, H., Argall, A. D., Luan, L., Xie, C., & Guo, L. (2018) · Nano Research · doi:10.1007/s12274-018-2127-4 · Cited by 31
Dohle, E., Swanson, E., Jovanović, L., Yusuf, S., Thompson, L., Horsfall, H. L., Muirhead, W. R., Bashford, L., & Brannigan, J. (2025) · Advanced Science · doi:10.1002/advs.202501912 · Cited by 31
In Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 30
Decoding methods for neural prostheses: where have we reached?
Li, Z. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00129 · Cited by 30
“Perge et al. (2013) found significant intra-day changes in neural firing rates and concluded that 85% of these changes were likely due to physiological mechanisms.”
BackgroundCandrea, D. N., Shah, S., Luo, S., Angrick, M., Rabbani, Q., Coogan, C. G., Milsap, G., Nathan, K., Wester, B. A., Anderson, W. S., et al. (2024) · Communications Medicine · doi:10.1038/s43856-024-00635-3 · Cited by 32
Jarosiewicz, B., Sarma, A. A., Saab, J., Franco, B., Cash, S. S., Eskandar, E. N., & Hochberg, L. R. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2017.03.001 · Cited by 29
Self-citationEmerging Penetrating Neural Electrodes: In Pursuit of Large Scale and Longevity
Luan, L., Yin, R., Zhu, H., & Xie, C. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-090622-050507 · Cited by 28
“Moreover, both acute and chronic single-unit recordings showed significant variations that confounded the decoding of neural activity (81, 82).”
BackgroundDeo, D. R., Rezaii, P. G., Hochberg, L. R., Okamura, A. M., Shenoy, K. V., & Henderson, J. M. (2021) · IEEE Transactions on Haptics · doi:10.1109/toh.2021.3072615 · Cited by 27
Self-citationDecoder calibration with ultra small current sample set for intracortical brain–machine interface
Zhang, P., Ma, X., Chen, L., Zhou, J., Wang, C., Li, W., & He, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8a4 · Cited by 26
Adaptive Offset Correction for Intracortical Brain–Computer Interfaces
Homer, M. L., Perge, J. A., Black, M. J., Harrison, M. T., Cash, S. S., & Hochberg, L. R. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287768 · Cited by 19
“Several studies have reported this phenomenon, called nonstationarity, in which unexpected changes occur in the statistical characteristics of the neural signals [4], [7], [14]–[20].”
BackgroundSelf-citationSpeech-related dorsal motor cortex activity does not interfere with iBCI cursor control
Stavisky, S. D., Willett, F. R., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5b72 · Cited by 25
Self-citationFew-shot Algorithms for Consistent Neural Decoding (FALCON) Benchmark
Karpowicz, B. M., Ye, J., Fan, C., Tostado-Marcos, P., Rizzoglio, F., Washington, C., Scodeler, T., de Lucena, D., Nason, S. R., Mender, M. J., et al. (2024) · neural information processing systems · doi:10.52202/079017-2439 · Cited by 26
Self-citationGregory, B. A., Thompson, C. H., Salatino, J. W., Railing, M. J., Zimmerman, A. F., Gupta, B., Williams, K., Beatty, J. A., Cox, C. L., & Purcell, E. K. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.07.027 · Cited by 25
Long-term flexible penetrating neural interfaces: materials, structures, and implantation
Gu, C., Jiang, J., Tao, T. H., Wei, X., & Sun, L. (2021) · Science China Information Sciences · doi:10.1007/s11432-021-3321-7 · Cited by 24
An Implantable Biohybrid Neural Interface Toward Synaptic Deep Brain Stimulation
Sifringer, L., Fratzl, A., Clément, B., Chansoria, P., Mönkemöller, L. S., Duru, J., Ihle, S. J., Steffens, S., Beltraminelli, A., Ceylan, E., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202416557 · Cited by 24
Brandman, D. M., Burkhart, M. C., Kelemen, J. N., Franco, B., Harrison, M. T., & Hochberg, L. R. (2018) · Neural Computation · doi:10.1162/neco_a_01129 · Cited by 24
“With linear models, nonstationarities have been shown to degrade decoding performance (Jarosiewicz et al., 2015; Perge et al., 2013).”
BackgroundMethodInfluentialSelf-citationHosman, T., Pun, T. K., Kapitonava, A., Simeral, J. D., & Hochberg, L. R. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123740 · Cited by 23
“Performance declines when the decoder is unable to adapt or be robust against such within-and across-day instabilities [4], [5].”
BackgroundSelf-citationWhitsitt, Q. A., Saxena, A., Patel, B., Evans, B. M., Hunt, B., & Purcell, E. K. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5936 · Cited by 23
“It has been predicted that ∼ 85% of firing rate variability, which can lead to decreased BCI performance, is due to physiological changes [8].”
BackgroundBrandman, D. M., & Hochberg, L. R. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch9 · Cited by 23
Self-citationRobust neural decoding by kernel regression with Siamese representation learning
Li, Y., Qi, Y., Wang, Y., Wang, Y., Xu, K., & Pan, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2c4e · Cited by 22
“Studies showed that intracortical neural recordings are unstable [45, 46], which poses a challenge for decoders to maintain BCI performance.”
Eleryan, A., Vaidya, M., Southerland, J., Badreldin, I. S., Balasubramanian, K., Fagg, A. H., Hatsopoulos, N., & Oweiss, K. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00023 · Cited by 20
“…on time and amplitude features of the waveforms perform poorer than offline spike sorting algorithms that use more sophisticated feature extraction and clustering techniques, since spike-amplitude instability is known to cause spike detection and sorting errors for such methods (Perge et al., 2013).”
BackgroundModulation Depth Estimation and Variable Selection in State-Space Models for Neural Interfaces
Malik, W. Q., Hochberg, L. R., Donoghue, J. P., & Brown, E. N. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2360393 · Cited by 20
“This situation may occur in practice due to relative micromovements of the recording array and single units [6].”
BackgroundSelf-citationFan, C., Hahn, N., Kamdar, F., Avansino, D., Wilson, G. H., Hochberg, L., Shenoy, K. V., Henderson, J. M., & Willett, F. R. (2023) · arXiv · doi:10.48550/arxiv.2311.03611 · Cited by 19
“Nonstationarities are caused by various factors, including microelectrode array movement [40], device degradation [50], single neuron physiological changes [33, 9, 3], and variability at the behavioral level [7, 46].”
BackgroundSelf-citationStructural, Functional, and Genetic Changes Surrounding Electrodes Implanted in the Brain
Gupta, B., Saxena, A., Perillo, M. L., Wade-Kleyn, L. C., Thompson, C. H., & Purcell, E. K. (2024) · Accounts of Chemical Research · doi:10.1021/acs.accounts.4c00057 · Cited by 19
A novel microwire interface for small diameter peripheral nerves in a chronic, awake murine model
Falcone, J., Liu, T., Goldman, L., Pogue David, D., Rieth, L. W., Bouton, C. E., Straka, M., & Sohal, H. S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9b6d · Cited by 19
Revisiting embodiment for brain–computer interfaces
Serim, B., Spapé, M., & Jacucci, G. (2023) · Human-Computer Interaction · doi:10.1080/07370024.2023.2170801 · Cited by 18
“Persistence in brain–interface connections has long been a focus in clinical studies (e.g., Downey et al., 2018; Perge et al., 2013), but should also be relevant for its role in supporting new forms of expression.”
Chen, K., Forrest, A. M., Burgos, G.-G., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5049 · Cited by 18
Brain–computer interfaces patient preferences: a systematic review
Brannigan, J., Liyanage, K., Horsfall, H. L., Bashford, L., Muirhead, W. R., & Fry, A. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad94a6 · Cited by 20
“In the case of intracortical microelectrode arrays, frequent device recalibration is also necessary, due to the inherent instability of these signals [41].”
Volitional control of single-electrode high gamma local field potentials by people with paralysis
Milekovic, T., Bacher, D., Sarma, A. A., Simeral, J. D., Saab, J., Pandarinath, C., Yvert, B., Sorice, B. L., Blabe, C. H., Oakley, E. M., et al. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00131.2018 · Cited by 18
“2008), difficulty in recording stable single unit activity signals (Barrese et al. 2013; Dickey et al. 2009; Leach et al. 2010; Perge et al. 2013; Polikov et al. 2005) poses challenges for their translation to clinical use.”
BackgroundResultSelf-citationCastaño-Candamil, S., Piroth, T., Reinacher, P. C., Sajonz, B., Coenen, V. A., & Tangermann, M. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2941453 · Cited by 18
“However, for applications such as the identification of neural markers for adaptive DBS, complex confounding relations and signal nonstationarities on timescales of seconds to minutes render the UPDRS-III unpractical [21]–[24], and consequently, a direct correlation with its score should not be the main goal of an alt…”
BackgroundFeature-Selection-Based Transfer Learning for Intracortical Brain–Machine Interface Decoding
Zhang, P., Li, W., Ma, X., He, J., Huang, J., & Li, Q. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3034234 · Cited by 18
“Because the relationship between the recorded neural activities and the specific movement intentions might vary over time [19]–[21], the historical data cannot be used directly for decoder calibration and it would take a long time to collect the new data before using the iBMIs properly [22], [23].”
BackgroundMethodEncoding of forelimb forces by corticospinal tract activity in the rat
Guo, Y., Foulds, R. A., Adamovich, S., & Şahin, M. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00062 · Cited by 18
“ORIGINAL RESEARCH ARTICLE published: 01 May 2014 doi: 10.3389/fnins.2014.00062 Encoding of forelimb forces by corticospinal tract activity in the rat”
InfluentialAlterations in Ion Channel Expression Surrounding Implanted Microelectrode Arrays in the BrainPreprint
Salatino, J. W., Kale, A. P., & Purcell, E. K. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/518811 · Cited by 18
Wang, X.-Q., Sun, H.-Q., Si, J.-Y., Lin, Z.-Y., Zhai, X.-M., & Lu, L. (2024) · Chinese Medical Sciences Journal · doi:10.24920/004377 · Cited by 17
Nanobiomaterials for bionic eye
Ghaffari, M. S., Moztarzadeh, S., Rahmanian, F., Yazdanpanah, A., Ramedani, A., Mills, D. K., & Mozafari, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-41532-3.00008-7 · Cited by 17
Soleymankhani, A., & Shalchyan, V. (2021) · Neuroscience · doi:10.1016/j.neuroscience.2021.05.036 · Cited by 17
Letner, J. G., Patel, P. R., Hsieh, J., Flores, I. M. S., della Valle, E., Walker, L. A., Weiland, J. D., Chestek, C. A., & Cai, D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acbf78 · Cited by 17
Fan, C., Hahn, N. V., Kamdar, F. B., Avansino, D. T., Wilson, G. H., Hochberg, L. R., Shenoy, K. V., Henderson, J. M., & Willett, F. R. (2023) · PubMed · Cited by 17
Self-citationPolydimethylsiloxane-based optical waveguides for tetherless powering of floating microstimulators
Erşen, A., & Şahin, M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.5.055005 · Cited by 17
Procházka, A. (2018) · Comprehensive physiology · doi:10.1002/cphy.c180006 · Cited by 17
Willett, F. R., Murphy, B. A., Memberg, W. D., Blabe, C. H., Pandarinath, C., Walter, B. L., Sweet, J. A., Miller, J. P., Henderson, J. M., Shenoy, K. V., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5990 · Cited by 16
Self-citationOn the asynchronously continuous control of mobile robot movement by motor cortical spiking activity
Xu, Z., So, R. Q., Toe, K. K., Ang, K. K., & Guan, C. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944266 · Cited by 16
“It was reported [22] the possible intra-day signal instability in terms of changes in unit firing rate and spike waveform”
BackgroundPrecise control of neural activity using dynamically optimized electrical stimulation
Shah, N. P., Phillips, A., Madugula, S., Lotlikar, A., Gogliettino, A. R., Hays, M. R., Grosberg, L., Brown, J., Dusi, A., Tandon, P., et al. (2024) · eLife · doi:10.7554/elife.83424 · Cited by 15
A Study on Biocompatible Polymer-Based Packaging of Neural Interface for Chronic Implantation
Park, H., Choi, W., Oh, S.-H., Kim, Y.-J., Seok, S., & Kim, J. (2022) · Micromachines · doi:10.3390/mi13040516 · Cited by 15
“In a process of acquiring a signal using a neural electrode, the deviation may sufficiently occur depending on system parameters, such as electrode impedance, cross-talk between electrodes, and unknown recording conditions, and the result of impedance measurement research is reported to be different over time in the s…”
BackgroundMulti-source domain adaptation for decoder calibration of intracortical brain-machine interface
Li, W., Ji, S., Chen, X., Kuai, B., He, J., Zhang, P., & Li, Q. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc528 · Cited by 14
“These schemes were (a) OSC: Source samples from the previous day were directly used as training data to calibrate the decoder, and the testing data in the target domain were classified [11, 19].”
BackgroundMethodSparse Ensemble Machine Learning to Improve Robustness of Long-Term Decoding in iBMIs
Shaikh, S., So, R. Q., Sibindi, T. M., Libedinsky, C., & Basu, A. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2962708 · Cited by 14
“The subject is made to perform a set of calibration trials and target labels are collected along with neural activity [10], [15], [16], [18].”
BackgroundMasse, N. Y., Jarosiewicz, B., Simeral, J. D., Bacher, D., Stavisky, S. D., Cash, S. S., Oakley, E. M., Berhanu, E., Eskandar, E. N., Friehs, G. M., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.001 · Cited by 14
“This problem can be further exacerbated if the amplitude of the recorded action potentials decreases over months and years post-implant (Chestek et al., 2011) or when signal amplitudes are nonstationary on the timescale of minutes and hours (Perge et al., 2013).”
BackgroundSelf-citationExploring the trade-off between deep-learning and explainable models for brain-machine interfaces
Cubillos, L. H., Revach, G., Mender, M. J., Costello, J., Temmar, H., Hite, A., Zutshi, D., Wallace, D. M., Ni, X., Kelberman, M. M., et al. (2024) · neural information processing systems · doi:10.52202/079017-4257 · Cited by 14
Rizzoglio, F., Altan, E., Ma, X., Bodkin, K. L., Dekleva, B. M., Solla, S. A., Kennedy, A., & Miller, L. E. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad038e · Cited by 13
“Similarly, in direct decoding, we tested alignment of the latent signals over time, as a means to address the steady decline in performance of a fixed decoder over time due to the inherent instabilities of the recorded neural signals (Perge et al 2013, Sussillo et al 2016, Downey et al 2018).”
BackgroundMethodZhang, P., Huang, J., Li, W., Ma, X., Yang, P., Dai, J., & He, J. (2018) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2018.2869587 · Cited by 13
“However, spike recording is not stable and the number of neurons recorded by electrodes may gradually reduce over time [12] which can lead declines in performance of decoders [13].”
BackgroundHuang, S.-H., Shmoel, N., Jankowski, M. M., Erez, H., Sharon, A., Abu-Salah, W., Nelken, I., Weiss, A. M., & Spira, M. E. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00926 · Cited by 12
“One major shortcoming of these devices is the deterioration of the recording yield and Field Potential (FP) amplitudes within days to weeks of implantation (Jackson and Fetz, 2007; Perge et al., 2013; Voigts et al., 2013; Lee et al., 2018).”
BackgroundBiotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
[Ethical considerations for medical applications of implantable brain-computer interfaces].
Zhang, Z., Chen, Y., Zhao, X., Wang, F., Ding, P., Zhao, L., & Fu, Y. (2024) · PubMed Central · doi:10.7507/1001-5515.202309083 · Cited by 11
Bundy, D. T., Guggenmos, D. J., Murphy, M. D., & Nudo, R. J. (2019) · PLoS ONE · doi:10.1371/journal.pone.0219034 · Cited by 12
“Additionally, changes in firing rate and spike amplitude are even seen within single 666 recording days [32].”
BackgroundSharon, A., Shmoel, N., Erez, H., Jankowski, M. M., Friedmann, Y., & Spira, M. E. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.764448 · Cited by 11
SPINT: Spatial Permutation-Invariant Neural Transformer for Consistent Intracortical Motor Decoding
Le, T., Fang, H., Li, J., Nguyen, T., Lu, M., Orsborn, A. L., Sümbül, U., & Shlizerman, E. (2025) · neural information processing systems · doi:10.52202/085713-0870 · Cited by 10
Human learning of noninvasive brain–computer interfaces via manifold geometry
Busch, E. L., Fincke, E. C., Lajoie, G., Krishnaswamy, S., & Turk‐Browne, N. B. (2026) · Nature Neuroscience · doi:10.1038/s41593-026-02311-2 · Cited by 10
Liu, C. X., Guo, K., Lu, J., & Yang, H. (2023) · Advances in Mechanical Engineering · doi:10.1177/16878132221148018 · Cited by 10
A Discriminative Approach to Bayesian Filtering with Applications to Human Neural Decoding
Burkhart, M. C. (2019) · HAL · Cited by 10
Neuroimplants and the Glial Scar: What Makes the Brain–Computer Link Work?
Paveliev, M., Melnikova, A., Egorchev, A. A., Parpura, V., & Aganov, A. V. (2025) · Journal of Neurochemistry · doi:10.1111/jnc.70203 · Cited by 11
“Real-world neuroimplant signal stability problems have been re-ported both on short (intraday) time scales (Downey et al. 2018; Perge et al. 2013) and over months (Vansteensel et al. 2024).”
Zhang, P., Chao, L., Chen, Y., Ma, X., Wang, W., He, J., Huang, J., & Li, Q. (2020) · Sensors · doi:10.3390/s20195528 · Cited by 9
Schröder, T., Taylor, R. T., Hay, M. Y. A. E., Nemri, A., França, A. S. C., Battaglia, F. P., Tiesinga, P. H. E., Schölvinck, M. L., & Havenith, M. N. (2024) · Journal of Visualized Experiments · doi:10.3791/66867 · Cited by 9
Sammut, S., Koh, R. G. L., & Zariffa, J. (2021) · Sensors · doi:10.3390/s21020506 · Cited by 9
A brain machine interface framework for exploring proactive control of smart environments
Braun, J.-M., Fauth, M. J., Berger, M., Huang, N.-S., Simeoni, E., Gaeta, E., do Carmo, R. R., García-Betances, R. I., Arredondo, M. T., Gail, A., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-60280-7 · Cited by 8
“However, stable long-term recordings from intracranial electrode arrays are difficult to obtain such that the performance of a fixed decoder degrades substantially over time 12–14 , requiring a regular re-calibration of the decoder.”
Single-Trial Decoding of Motion Direction During Visual Attention From Local Field Potential Signals
Kousarrizi, M. R. N., Nasrabadi, A. M., & Daliri, M. R. (2021) · IEEE Access · doi:10.1109/access.2021.3076865 · Cited by 8
Feasibility of Using the Utah Array for Long-Term Fully Implantable Neuroprosthesis Systems
Bullard, A. J. (2019) · Deep Blue (University of Michigan) · Cited by 8
The ‘Brussels 4’: essential requirements for implantable brain–computer interface user autonomy
Oxley, T. J., Deo, D. R., Cernera, S., Sawyer, A., Putrino, D. F., Ramsey, N. F., & Fry, A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada0e6 · Cited by 7
“These drifts can occur over hours to days [41, 48].”
Sensory constraints on volitional modulation of the motor cortexPreprint
Fisac, C. F., & Chase, S. M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.01.22.525098 · Cited by 7
Ma, X., Rizzoglio, F., Bodkin, K. L., & Miller, L. E. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adab93 · Cited by 6
“It had been well acknowledged that the drifting of neural recordings may affect the stability of iBCI decoding accuracy [36], even within the same session [37].”
Unsupervised Neural Manifold Alignment for Stable Decoding of Movement from Cortical Signals
Ganjali, M., Mehridehnavi, A., Rakhshani, S., & Khorasani, A. (2023) · International Journal of Neural Systems · doi:10.1142/s0129065724500060 · Cited by 7
Lee, W.-H., Karpowicz, B. M., Pandarinath, C., & Rouse, A. G. (2024) · Journal of Neuroscience · doi:10.1523/jneurosci.1224-23.2024 · Cited by 6
Yang, S., Huang, C.-J., & Huang, J.-S. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108208 · Cited by 6
Yang, S., Wang, H., Lo, Y., Lai, H.-Y., Chen, K., Lan, Y.-H., Kao, C.-C., Chou, C., Lin, S.-H., Huang, J.-W., et al. (2020) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2020.00022 · Cited by 6
“However, under real neural recording conditions, there existed a high degree of within-and across-day variability (Simeral et al., 2011; Perge et al., 2013, 2014; Wodlinger et al., 2014; Downey et al., 2018) that prevented satisfaction of the stationary statistical assumption.”
BackgroundPiozin, C., Altamira, G. H., Simon, C., Lavrard, B., Audran, J.-Y., Waszak, F., & Eskiizmirliler, S. (2022) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci53720.2022.9734823 · Cited by 6
Dong, Y., Hu, D., Wang, S., & He, J. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104453 · Cited by 6
Donoghue, J. P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00025-5 · Cited by 6
Self-citationSpira, M. E., Erez, H., & Sharon, A. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.807797 · Cited by 6
Nason, S. R., Deevi, P. I., Jude, J. J., Rabbani, Q., Jacques, B. G., Pritchard, A. L., Wimalasena, L. N., Richards, B. A., Karpowicz, B. M., Bechefsky, P. H., et al. (2026) · medRxiv · doi:10.64898/2026.02.19.26346583 · Cited by 8
Self-citationChen, X., Fu, Z., Zhang, P., Chen, X., & Huang, J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3586870 · Cited by 5
“Primarily, there is temporal degradation of decoding performance, mainly attributed to electrode-tissue interface reactions and mechanical micromotion [9], necessitating frequent recalibration processes [10].”
Shao, X., Chung, R. S., Cavaleri, J., Campo-Vera, R. M. D., Parra, M., Sundaram, S., Zhang, S., Surabhi, A., McGinn, R. J., Liu, C. Y., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-14805-3 · Cited by 5
“This session-to-session variability has been documented in numerous BCI studies 14,63–65 .”
Continuous and discrete decoding of overt speech with scalp electroencephalography (EEG)
Craik, A., Dial, H. R., & Contreras-Vidal, J. L. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8d0a · Cited by 5
Implantable computer-controlled adaptive multielectrode positioning system
Ferrea, E., Suriya-Arunroj, L., Hoehl, D., Thomas, U., & Gail, A. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00504.2017 · Cited by 5
“…tissue response at the electrode tip, the number of recorded units in chronic and semichronic electrodes normally decreases over time, thereby limiting the number of units being recorded during the lifetime of fixed-geometry implants (Chestek et al. 2011; Perge et al. 2013; Tremblay et al. 2015).”
BackgroundChoi, H., Na, B., Lee, J., & Kong, K. (2018) · Applied Sciences · doi:10.3390/app8112287 · Cited by 5
“However, the invasive BMI methods are too risky and cannot be applied to daily-life applications [10,22].”
BackgroundNickl, R. W., Anaya, M. A., Thomas, T. M., Fifer, M. S., Candrea, D. N., McMullen, D. P., Thompson, M. C., Osborn, L. E., Anderson, W. S., Wester, B. A., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-13436-2 · Cited by 5
Rehabilitation Technologies for Spinal Injury
Asín-Prieto, G., Andrés, A. I., Venkatakrishnan, A., Malik, W. Q., Dietz, V., & Rymer, W. Z. (2015) · Biosystems & biorobotics · doi:10.1007/978-3-319-24901-8_3 · Cited by 5
Self-citationŚliwowski, M. (2022) · theses.fr (ABES) · doi:10.70675/7c6c593ezcd6az41a3z8ad3za50ae36de60c · Cited by 5
Transient localist representations in critical branching networks
Rodny, J. J., Shea, T. M., & Kello, C. T. (2017) · Language, Cognition and Neuroscience · doi:10.1080/23273798.2016.1242760 · Cited by 4
Chen, D., Cao, C., Gong, J., Huang, J., Xiao, J., Huang, Q., Guo, Y., & Li, Y. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3499319 · Cited by 4
“Spike pulses, while effective, are inherently unstable and may lead to decoder performance degradation over time [15], [16], [17], [18], [19].”
Multi-dimensional Neural Decoding with Orthogonal Representations for Brain-Computer InterfacesPreprint
Tian, K., Zhao, S., Zhang, Y., & Yu, S. P. (2025) · AAAI Publications (The Association for the Advancement of Artificial Intelligence (AAAI)) · doi:10.48550/arxiv.2508.08681 · Cited by 4
“…poses major challenges for practical BCI deployment, as neural activity changes significantly due to electrode displacement and tissue reactions (Perge et al. 2013; Chestek et al. 2011; Willett et al. 2021 Unlike existing single-output decoders, OrthoSchema is specifically designed for MND…”
NeuroGator: A Low-Power Gating System for Asynchronous BCI Based on LFP Brain State Estimation
He, B., Liu, C., Qi, Z., Xue, N., & Yao, L. (2026) · Brain Sciences · doi:10.3390/brainsci16020141 · Cited by 3
“That emphasis on stability is crucial, as we know that maintaining stable SUA in chronic recordings is an uphill battle; between micromotion and the body’s inevitable tissue response, tracking the exact same neuron over days or weeks is rarely reliable [5,14].”
An Ultrathin Low-Invasive Flexible Probe for Accurate Neural Stimulating
Guo, Z., Wang, L., Tu, K., Xi, Y., Hong, W., Wang, X., Yang, B. T., Lin, Z., & Liu, J. (2022) · IEEE Electron Device Letters · doi:10.1109/led.2022.3207051 · Cited by 3
“On the other hand, the anchoring structures are conducive to restricting further movement of the recording site relative to the surrounding neuronal tissue and prevent sudden waveform changes in time scales as short as hours in the chronic implantation [15], [16], [17], [18].”
BackgroundA PDMS-based optical waveguide for transcutaneous powering of microelectrode arrays
Erşen, A., & Şahin, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591721 · Cited by 3
“The brain continuously moving inside the skull as a viscoelastic structure causes two fundamental problems that are at a trade-off with each other [6].”
BackgroundFlexible, Multi-Shank Stacked Array for High-Density Omini-Directional Intracortical Recording
Guo, Z., Wang, L., Ji, B., Xi, Y., Yang, B. T., & Liu, J. (2021) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems51782.2021.9375160 · Cited by 3
“Furthermore, the displacement between the electrodes and neurons will result in sudden waveform changing [5] and it’s difficult to track individual neurons for long time.”
BackgroundResearch on Brain-Computer Interface System for Vehicle Control Based on Motion Imagination
yan, Z., & jian, X. (2020) · doi:10.1145/3436286.3436495 · Cited by 3
Combining Neural Population Recordings: Theory and Application
Bishop, W. E. (2015) · KiltHub Repository · doi:10.1184/r1/6715196 · Cited by 3
Multi-dimensional Neural Decoding with Orthogonal Representations for Brain-Computer Interfaces
田开熙, Zhao, S., Zhang, Y., & Yu, S. (2026) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v40i3.37191 · Cited by 2
“…poses major challenges for practical BCI deployment, as neural activity changes significantly due to electrode displacement and tissue reactions (Perge et al. 2013; Chestek et al. 2011; Willett et al. 2021 Unlike existing single-output decoders, OrthoSchema is specifically designed for MND…”
Rupp, K., Schieber, M. H., & Thakor, N. V. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943836 · Cited by 2
“Single units recorded from multielectrode arrays are particularly unstable due to factors that include changes in electrode impedance and micromotion of the electrode arrays [7].”
Kifouche, A., & Guessoum, A. (2020) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijece.v10i5.pp4721-4737 · Cited by 2
Sanabria, A., & Luís, J. (2017) · Cited by 2
Metadata
- Authors
- Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R.
- Affiliations
- Brown University (US)
- Harvard University (US)
- Rhode Island Hospital (US)
- Corresponding author
- Perge, János A
- Homer, Mark L
- Malik, Wasim Q
- Cash, Sydney
- Eskandar, Emad
- Friehs, Gerhard
- Donoghue, John P
- Hochberg, Leigh R
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-04-10
- Volume
- 10
- Issue
- 3
- Pages
- 036004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3693851
- OpenAlex
- W2047933600
- Semantic Scholar
- 3d4a4ba52520ade57c5c191d755cca713a3cf5c8
- Cited by
- 243
- References
- 67
- Citations by year
- 2026: 20 · 2025: 17 · 2024: 31 · 2023: 19 · 2022: 13 · 2021: 16 · 2020: 25 · 2019: 14 · 2018: 19 · 2017: 21 · 2016: 15 · 2015: 11 · 2014: 16 · 2013: 5
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (n01hd53403-6-0-1)
- National Institute on Deafness and Other Communication Disorders (R01DC009899)
- National Institute of Neurological Disorders and Stroke (R01NS025074)
- National Institute of Biomedical Imaging and Bioengineering (R01EB007401)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HHSN275201100018C, N01HD10018, N01 HD053403)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- motor cortex, tetraplegia, neural decoding, recording artifacts, adaptive decoding
- MeSH terms
- Adult, Algorithms, Circadian Rhythm, Electroencephalography, Female, Humans, Male, Middle Aged, Motor Cortex, Nerve Net, Quadriplegia, Sensitivity and Specificity, Reproducibility of Results, Evoked Potentials, Motor, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.