Quasi-monopolar electrical stimulation of the retina: a computational modelling study
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: In this study we investigated the feasibility of quasi-monopolar (QMP) electrical stimulation for retinal implant devices, using a computational model of the retinal ganglion cell layer. APPROACH: When used with hexagonally arrayed multiple electrodes, QMP stimulation is a hybrid of hexapolar and conventional monopolar stimulus modes. In hexapolar mode, each active electrode is surrounded by six guards which collectively return the stimulus current, whereas in monopolar mode the injected stimulus current is returned through a distant return electrode. The QMP paradigm, on the other hand, distributes the return current between the guard electrodes as well as the distant return. The electrodes tested were 25, 50 and 100 µm in diameter, with hexagonally arranged centre-to-centre spacing of either double or quadruple this diameter. MAIN RESULTS: Simulation results indicated that electrode size had minimal effects on subretinal threshold currents, whilst electrode configuration and centre-to-centre spacing played major roles in determining thresholds and spatial activation patterns. Threshold charge densities for 50 and 100 µm electrodes were generally within the safe limit. SIGNIFICANCE: We found that QMP stimulation offers greater advantages compared to monopolar and hexapolar stimulation, in that it combines the low thresholds of monopolar stimulation with the localized spatial activation achieved with hexapolar electrodes during parallel stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 1×
“in patients, enabling them to perform simple tasks [5, 6].”
BackgroundCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Action potential generation requires a high sodium channel density in the axon initial segment
Kole, M. H. P., Ilschner, S. U., Kampa, B. M., Williams, S. R., Ruben, P. C., & Stuart, G. J. (2008) · Nature Neuroscience · doi:10.1038/nn2040 · Cited by 703
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“Elongated or oval phosphenes have been reported in a number of clinical trials [32, 68, 69].”
BackgroundAhuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · cited 3×
“However, an epiretinal stimulation study by Jensen et al [15] found that although on the retinal surface threshold currents for RGC activation are significantly lower for smaller electrodes, this difference diminishes with distance, as the electrodes are placed further above the retinal surface.”
BackgroundMORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158
Cited by
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“For instance, if the electrodes are densely packed, activation of an electrode at one site may have deleterious effects on neighboring sites (Abramian et al., 2014).”
BackgroundSelf-citationStimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Cortical visual prostheses: From microstimulation to functional percept
Najarpour Foroushani, A., Pack, C. C., & Sawan, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa904 · Cited by 62
Metadata
- Authors
- Abramian, M., Lovell, N. H., Habib, A., Morley, J. W., Suaning, G. J., & Dokos, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-02-21
- Volume
- 11
- Issue
- 2
- Pages
- 025002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2002382433
- Cited by
- 35
- References
- 17
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quasi-monopolar electrical stimulation of the retina: a computational modelling study. https://app.cochat.ai/papers/10.1088/1741-2560/11/2/025002
- The paper
- Abramian, M., Lovell, N. H., Habib, A., Morley, J. W., Suaning, G. J., & Dokos, S. (2014). Quasi-monopolar electrical stimulation of the retina: a computational modelling study. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/2/025002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.