SiC protective coating for photovoltaic retinal prosthesis
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate plasma-enhanced, chemically vapor deposited (PECVD) amorphous silicon carbide (α-SiC:H) as a protective coating for retinal prostheses and other implantable devices, and to study their failure mechanisms in vivo. APPROACH: Retinal prostheses were implanted in rats sub-retinally for up to 1 year. Degradation of implants was characterized by optical and scanning electron microscopy. Dissolution rates of SiC, SiN x and thermal SiO2 were measured in accelerated soaking tests in saline at 87 °C. Defects in SiC films were revealed and analyzed by selectively removing the materials underneath those defects. MAIN RESULTS: At 87 °C SiN x dissolved at 18.3 ± 0.3 nm d(-1), while SiO2 grown at high temperature (1000 °C) dissolved at 0.104 ± 0.008 nm d(-1). SiC films demonstrated the best stability, with no quantifiable change after 112 d. Defects in thin SiC films appeared primarily over complicated topography and rough surfaces. SIGNIFICANCE: SiC coatings demonstrating no erosion in accelerated aging test for 112 d at 87 °C, equivalent to about 10 years in vivo, can offer effective protection of the implants. Photovoltaic retinal prostheses with PECVD SiC coatings exhibited effective protection from erosion during the 4 month follow-up in vivo. The optimal thickness of SiC layers is about 560 nm, as defined by anti-reflective properties and by sufficient coverage to eliminate defects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 1×
“to body fluids and associated corrosion [10, 14, 15, 18].”
Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146 · cited 1×
“Low temperature (395 °C) LPCVD silicon oxide (SiO2) implanted sub-retinally in rabbits was found to dissolve after 6–12 months [23].”
Background
Cited by
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Self-citationCharacteristics of prosthetic vision in rats with subretinal flat and pillar electrode arrays
Ho, E., Lei, X., Flores, T., Lorach, H., Huang, T., Galambos, L., Kamins, T., Harris, J., Mathieson, K., & Palanker, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab34b3 · Cited by 65
“all implants were covered with 380 nm of amorphous silicon carbide (SiC) on top of 70 nm of silicon dioxide (SiO2), optimized for 880 nm illumination (32).”
Metadata
- Authors
- Lei, X., Kane, S., Cogan, S., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T., Harris, J., & Palanker, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-06-21
- Volume
- 13
- Issue
- 4
- Pages
- 046016
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2463072951
- Cited by
- 66
- References
- 12
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SiC protective coating for photovoltaic retinal prosthesis. https://app.cochat.ai/papers/10.1088/1741-2560/13/4/046016
- The paper
- Lei, X., Kane, S., Cogan, S., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T., Harris, J., & Palanker, D. (2016). SiC protective coating for photovoltaic retinal prosthesis. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/13/4/046016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.