Abstract
We calculated the electric fields induced in the brain during transcranial current stimulation (TCS) using a finite-element concentric spheres human head model. A range of disc electrode configurations were simulated: (1) distant-bipolar; (2) adjacent-bipolar; (3) tripolar; and three ring designs, (4) belt, (5) concentric ring, and (6) double concentric ring. We compared the focality of each configuration targeting cortical structures oriented normal to the surface ('surface-radial' and 'cross-section radial'), cortical structures oriented along the brain surface ('surface-tangential' and 'cross-section tangential') and non-oriented cortical surface structures ('surface-magnitude' and 'cross-section magnitude'). For surface-radial fields, we further considered the 'polarity' of modulation (e.g. superficial cortical neuron soma hyper/depolarizing). The distant-bipolar configuration, which is comparable with commonly used TCS protocols, resulted in diffuse (un-focal) modulation with bi-directional radial modulation under each electrode and tangential modulation between electrodes. Increasing the proximity of the two electrodes (adjacent-bipolar electrode configuration) increased focality, at the cost of more surface current. At similar electrode distances, the tripolar-electrodes configuration produced comparable peak focality, but reduced radial bi-directionality. The concentric-ring configuration resulted in the highest spatial focality and uni-directional radial modulation, at the expense of increased total surface current. Changing ring dimensions, or use of two concentric rings, allow titration of this balance. The concentric-ring design may thus provide an optimized configuration for targeted modulation of superficial cortical neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617 · cited 1×
“We compare the focality and efficacy of TCS stimulation of cortex with remotely spaced bipolar electrodes (‘distantbipolar’) [6, 7, 11, 22, 28, 29], proximal bipolar electrodes (‘adjacent-bipolar’) [36–38], ‘tripolar’ electrodes and three ring electrode configurations: ‘belt’ [36, 37], ‘concentric ring’ and ‘double co…”
MethodElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“We note that the (charge-related) electrochemical product may not be an issue for acute noninvasive stimulation [93] and that the magnitude of scalp sensation does not correlate with threshold of brain stimulation [40, 44].”
BackgroundSelf-citationWhich elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Boosting slow oscillations during sleep potentiates memory
Marshall, L., Helgadóttir, H., Mölle, M., & Born, J. (2006) · Nature · doi:10.1038/nature05278 · Cited by 1,792
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Nitsche, M. A., Fricke, K., Henschke, U., Schlitterlau, A., Liebetanz, D., Lang, N., Henning, S., Tergau, F., & Paulus, W. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.049916 · Cited by 1,514
Liebetanz, D. (2002) · Brain · doi:10.1093/brain/awf238 · Cited by 1,383 · cited 1×
“Experimental and theoretical studies examining the mechanisms of TCS have implicated ‘direct’ modulation (polarization) of primary cortical neurons [8, 22, 23] and/or modulation of (NMDA) synaptic efficacy [24, 25].”
BackgroundAnodal transcranial direct current stimulation of prefrontal cortex enhances working memory
Fregni, F., Boggio, P. S., Nitsche, M., Bermpohl, F., Antal, A., Feredoes, E., Marcolin, M. A., Rigonatti, S. P., Silva, M. T. A., Paulus, W., et al. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-2334-6 · Cited by 1,159
Safety aspects of transcranial direct current stimulation concerning healthy subjects and patients
Poreisz, C., Boros, K., Antal, A., & Paulus, W. (2007) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2007.01.004 · Cited by 1,099
Cited by
Brunoni, A. R., Nitsche, M. A., Bolognini, N., Bikson, M., Wagner, T., Merabet, L., Edwards, D. J., Valero-Cabre, A., Rotenberg, A., Pascual-Leone, A., et al. (2012) · Brain stimulation · doi:10.1016/j.brs.2011.03.002 · Cited by 1,445
“For example, average current density (total current/electrode area) at the ‘‘active’’ electrode may be a useful metric to normalize specific neurophysiologic outcomes (eg, TMS evoked MEPs), there is no universal relationship between current density and brain modulation when one considers the full spectrum of possible…”
Self-citationDatta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
Self-citationDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Radman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702
Self-citationKuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695
Self-citationDeterminants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Self-citationEdwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.042 · Cited by 468
Self-citationPeterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Self-citationDatta, A., Truong, D., Minhas, P., Parra, L. C., & Bikson, M. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00091 · Cited by 404
Self-citationHuang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
Self-citationThe electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 334
Datta, A., Baker, J. M., Bikson, M., & Fridriksson, J. (2011) · Brain Stimulation · doi:10.1016/j.brs.2010.11.001 · Cited by 325
Self-citationEstablishing safety limits for transcranial direct current stimulation
Bikson, M., Datta, A., & Elwassif, M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.018 · Cited by 298
Self-citationAnimal models of transcranial direct current stimulation: Methods and mechanisms
Jackson, M. P., Rahman, A., Lafon, B., Kronberg, G., Ling, D., Parra, L. C., & Bikson, M. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.08.016 · Cited by 289
Self-citationBikson, M., Datta, A., Rahman, A., & Scaturro, J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.05.020 · Cited by 284
Self-citationComputational Models of Transcranial Direct Current Stimulation
Bikson, M., Rahman, A., & Datta, A. (2012) · Clinical EEG and Neuroscience · doi:10.1177/1550059412445138 · Cited by 283
Self-citationMoliadze, V., Antal, A., & Paulus, W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.04.033 · Cited by 270
Minhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Self-citationOn the importance of electrode parameters for shaping electric field patterns generated by tDCS
Saturnino, G. B., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.067 · Cited by 263
Villamar, M. F., Volz, M. S., Bikson, M., Datta, A., DaSilva, A. F., & Fregni, F. (2013) · Journal of Visualized Experiments · doi:10.3791/50309 · Cited by 261
Self-citationFaria, P., Hallett, M., & Miranda, P. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066017 · Cited by 243
“It also affects the fraction of the injected current that reaches the brain as well as the distribution of the radial and tangential components of the current density (Datta et al 2008).”
BackgroundMethodInfluentialTranscranial direct current stimulation (tDCS) in a realistic head model
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.052 · Cited by 232
“, 2006) or simplified models of cranial and extracranial components (Datta et al., 2008; Im et al., 2008; Miranda et al., 2006; Wagner et al., 2007a).”
BackgroundMethodNeuling, T., Wagner, S., Wolters, C. H., Zaehle, T., & Herrmann, C. S. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00083 · Cited by 227
“Different electrode sizes (Nitsche et al., 2007), shapes (Datta et al., 2008, 2009), and number of electrodes (Feira et al., 2009) can help to overcome the limitation of the focality of TES.”
BackgroundGuleyupoglu, B., Schestatsky, P., Edwards, D., Fregni, F., & Bikson, M. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.07.016 · Cited by 224
“In 2007, High-Definition transcranial Direct Current Stimulation (HD-tDCS) was proposed as a focalized form of tDCS (Datta et al., 2008, 2009).”
InfluentialSelf-citationBasic and functional effects of transcranial Electrical Stimulation (tES)—An introduction
Yavari, F., Jamil, A., Mosayebi Samani, M., Vidor, L. P., & Nitsche, M. A. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.06.015 · Cited by 218
“…innovative shapes and arrangements of electrodes such as multi-channel tDCS in a Laplacian arrangement for more focal effects (Datta et al., 2009; Datta et al., 2008), fractal electrodes (Mahdavi et al., 2015), and electrodes individually reshaped to the target cortical region (Tecchio et al.,…”
BackgroundElectroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
“When the electrodes are close together, as in some unilateral configurations, the electric field maximum in the cortex lies between the 2 electrodes, whereas when the electrodes are far apart, as in conventional BL configurations, there are local electric field maxima under each electrode.(57) Further, smaller electro…”
BackgroundDatta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211
“…any physiological or pathological effects, the importance of neuronal geometry relative to applied fields (Radman et al., 2009; modulation maps in Datta et al., 2008) or the complex dynamic response of the brain to stimulation (Bikson et al., 2004); 2) the role of baseline individual differences…”
BackgroundSelf-citationMechanisms and Effects of Transcranial Direct Current Stimulation
Giordano, J., Bikson, M., Kappenman, E. S., Clark, V. P., Coslett, H. B., Hamblin, M. R., Hamilton, R., Jankord, R., Kozumbo, W. J., McKinley, R. A., et al. (2017) · Dose-Response · doi:10.1177/1559325816685467 · Cited by 209
Self-citationKessler, S. K., Minhas, P., Woods, A. J., Rosen, A., Gorman, C., & Bikson, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076112 · Cited by 208
“As shown previously in adult models, high definition 4x1 montages produce focused stimulation under the center active electrode (in the case unilateral motor cortex) with current flow largely limited to the cortical region circumscribed under the return electrode ring [11,29].”
Self-citationTranscranial Current Brain Stimulation (tCS): Models and Technologies
Ruffini, G., Wendling, F., Merlet, I., Molaee-Ardekani, B., Mekonnen, A., Salvador, R., Soria-Frisch, A., Grau, C., Dunne, S., & Miranda, P. C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2200046 · Cited by 197
“Increased focality can also be achieved using concentric ring electrodes [35] or a combination of five small electrodes with four of them placed on a ring around the central one [37].”
BackgroundMethodKanai, R., Paulus, W., & Walsh, V. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.03.022 · Cited by 168
“Further studies combined with direct EEG measurements and technical developments such as improvements of electrode design (Datta et al., 2008) will allow one to refine tACS as a method of frequency dependent brain stimulation.”
BackgroundReducing aggressive responses to social exclusion using transcranial direct current stimulation
Riva, P., Romero Lauro, L. J., DeWall, C. N., Chester, D. S., & Bushman, B. J. (2015) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsu053 · Cited by 159
“Second, the small distance between the two electrodes should cause a large amount of current to be shunted through the scalp, thus further increasing the focality of the stimulation (Datta et al., 2008; Bikson et al., 2010).”
BackgroundHill, A. T., Rogasch, N. C., Fitzgerald, P. B., & Hoy, K. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.001 · Cited by 105
“…field models predict that this montage is able to focus stimulation to the region directly underneath the active electrode, with current flow restricted to brain regions contained within the surrounding ring of return electrodes (Datta et al., 2008, 2009; Kuo et al., 2013; Saturnino et al., 2015).”
Effects of High-Definition and Conventional tDCS on Response Inhibition
Hogeveen, J., Grafman, J., Aboseria, M., David, A., Bikson, M., & Hauner, K. K. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.04.015 · Cited by 95
“In an effort to improve the spatial focality of tDCS, researchers have recently developed high-definition tDCS (HD-tDCS) delivery systems [34,35].”
BackgroundSelf-citationSuh, H. S., Lee, W. H., & Kim, T.-S. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/6961 · Cited by 84
Stuttering severity modulates effects of non-invasive brain stimulation in adults who stutter
Garnett, E. O., Chow, H. M., Choo, A. L., & Chang, S.-E. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00411 · Cited by 39
“They also show more ‘‘normalized’’ brain activation patterns during such conditions (i.e., similar to nonstuttering speakers; De Nil et al., 2003; Preibisch et al., 2003; Neumann et al., 2005; Giraud et al., 2008; Kell et al., 2009; Toyomura et al., 2011, 2015).”
Background
Metadata
- Authors
- Datta, A., Elwassif, M., Battaglia, F., & Bikson, M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2008-04-28
- Volume
- 5
- Issue
- 2
- Pages
- 163-174
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2100733931
- Cited by
- 320
- References
- 89
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.