Integrated circuit amplifiers for multi-electrode intracortical recording
Open accessThe DOI matches its Crossref record; 238 of the 238 references it cites were found in a registry or an index.
Abstract
Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so environmental electrical noise is readily coupled to the neuronal signal. To minimize this noise, an amplifier is placed close to each probe. Thus, the need has arisen for many amplifiers to be placed near the cortex. Commercially available integrated circuits do not satisfy the area, power and noise requirements of this application, so researchers have designed custom integrated-circuit amplifiers. This paper presents a comprehensive survey of the neural amplifiers described in publications prior to 2008. Methods to achieve high input impedance, low noise and a large time-constant high-pass filter are reviewed. A tutorial on the biological, electrochemical, mechanical and electromagnetic phenomena that influence amplifier design is provided. Areas for additional research, including sub-nanoampere electrolysis and chronic cortical heating, are discussed. Unresolved design concerns, including teraohm circuitry, electrical overstress and component failure, are identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,847
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134 · cited 1×
“These systems differ in their input signal—for example, electroencephalogram (EEG), electrocorticogram (ECoG) or 3 Bergveld (1970) mentions but does not present an amplifier.”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · cited 1×
“Other issues that might arise are degradation caused by natural radiation (Theuwissen 2007), medical radiation (Prutchi et al 1999) or ion movement (Hance et al 1994).”
BackgroundBioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“Recent works start to take full advantage of the unique abilities of HDMEAs.”
InfluentialMuller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
“A literature survey [8] confirms that it is difficult to scale the area of a Fig.”
BackgroundSwitch-Matrix-Based High-Density Microelectrode Array in CMOS Technology
Frey, U., Sedivy, J., Heer, F., Pedron, R., Ballini, M., Mueller, J., Bakkum, D., Hafizovic, S., Faraci, F. D., Greve, F., et al. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035196 · Cited by 251
“Integrated neuronal amplifiers [23] are used for two different applications.”
BackgroundChandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
“These issues make the pseudoresistor unreliable in a clinical setting [19].”
BackgroundDesign of Ultra-Low Power Biopotential Amplifiers for Biosignal Acquisition Applications
Zhang, F., Holleman, J., & Otis, B. P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177089 · Cited by 237
“Low-frequency local field potentials (LFPs) have amplitudes as high as 5 mV and may contain signal energy below 1 Hz [6], [7].”
BackgroundInfluentialBallini, M., Muller, J., Livi, P., Chen, Y., Frey, U., Stettler, A., Shadmani, A., Viswam, V., Lloyd Jones, I., Jackel, D., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2359219 · Cited by 236
“APs have a 3 dB bandwidth typically around 2 kHz [27], with signal content up to 6 kHz.”
BackgroundA $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazicioglu, R. F., Grundlehner, B., Harpe, P., Makinwa, K. A. A., & Van Hoof, C. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 221
“This can degrade the CMRR [33] and increase the effect of mains interference on the system.”
BackgroundClose-Packed Silicon Microelectrodes for Scalable Spatially Oversampled Neural Recording
Scholvin, J., Kinney, J. P., Bernstein, J. G., Moore-Kochlacs, C., Kopell, N., Fonstad, C. G., & Boyden, E. S. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406113 · Cited by 208
“” A variety of different systems exist for this task [20].”
BackgroundChandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2753824 · Cited by 187
“A dc input impedance Z in larger than 1 G is required, since this limits the dc current to 50 pA for an offset voltage of 50 mV, which is sufficiently low for most applications [19].”
BackgroundEnergy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078815 · Cited by 165
Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Perez Velazquez, J. L., Carlen, P., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160
“A commonly accepted value for the Z IN is ten times larger than the electrode impedance, to avoid loss of signal [21].”
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“Moreover, several exhaustive reviews covering this discipline have been published [13-16].”
BackgroundMethodTrack-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991526 · Cited by 74
“Moreover, a high input impedance keeps the dc current low due to the EDO and avoids any tissue damage [31]–[33].”
BackgroundHottowy, P., Skoczeń, A., Gunning, D. E., Kachiguine, S., Mathieson, K., Sher, A., Wiącek, P., Litke, A. M., & Dąbrowski, W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066005 · Cited by 67
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
“The latter factor reduces the CMRR and also increases the effect of the main interferences on the system [77].”
BackgroundAn Area-Efficient Noise-Adaptive Neural Amplifier in 130 nm CMOS Technology
Chaturvedi, V., & Amrutur, B. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2178731 · Cited by 60
A Digitally Assisted, Signal Folding Neural Recording Amplifier
Chen, Y., Basu, A., Liu, L., Zou, X., Rajkumar, R., Dawe, G. S., & Je, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2288680 · Cited by 43
“It is difficult, however, for resistive element larger than 10 to pass reliability tests, prohibiting its use in critical signal paths of commercial implanted devices[13].”
BackgroundPeripheral Neural Activity Recording and Stimulation System
Loi, D., Carboni, C., Angius, G., Angotzi, G. N., Barbaro, M., Raffo, L., Raspopovic, S., & Navarro, X. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2123097 · Cited by 42
“We present here the preliminary experimental results obtained on animals.”
Result
Metadata
- Authors
- Jochum, T., Denison, T., & Wolf, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2009-01-12
- Volume
- 6
- Issue
- 1
- Pages
- 012001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2065682167
- Cited by
- 167
- References
- 238
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.