Integrated circuit amplifiers for multi-electrode intracortical recording
Open accessThe DOI matches its Crossref record; 238 of the 238 references it cites were found in a registry or an index.
Abstract
Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so environmental electrical noise is readily coupled to the neuronal signal. To minimize this noise, an amplifier is placed close to each probe. Thus, the need has arisen for many amplifiers to be placed near the cortex. Commercially available integrated circuits do not satisfy the area, power and noise requirements of this application, so researchers have designed custom integrated-circuit amplifiers. This paper presents a comprehensive survey of the neural amplifiers described in publications prior to 2008. Methods to achieve high input impedance, low noise and a large time-constant high-pass filter are reviewed. A tutorial on the biological, electrochemical, mechanical and electromagnetic phenomena that influence amplifier design is provided. Areas for additional research, including sub-nanoampere electrolysis and chronic cortical heating, are discussed. Unresolved design concerns, including teraohm circuitry, electrical overstress and component failure, are identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,847
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134 · cited 1×
“These systems differ in their input signal—for example, electroencephalogram (EEG), electrocorticogram (ECoG) or 3 Bergveld (1970) mentions but does not present an amplifier.”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · cited 1×
“Other issues that might arise are degradation caused by natural radiation (Theuwissen 2007), medical radiation (Prutchi et al 1999) or ion movement (Hance et al 1994).”
BackgroundBioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731 · cited 1×
“…in the previous two paragraphs, some papers with measured results and a notable compromise of noise, power and area are Hills et al (2002), Harrison et al (2006), Parthasarathy et al (2006), Blum et al (2007), Gosselin et al (2007a), Wattanapanitch et al (2007) and Yin and Ghovanloo…”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 1×
“Microprobes have been chronically implanted in few patients (Schmidt et al 1996, Ulbert et al 2001, Kennedy et al 2004, Hochberg et al 2006, McCreery 2008), and no data have been released on the dc probe current and the ensuing damage, if any.”
MethodChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
On the Origin of the Extracellular Action Potential Waveform: A Modeling Study
Gold, C., Henze, D. A., Koch, C., & Buzsáki, G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00979.2005 · Cited by 586
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451 · cited 5×
“The gate width should be maximized to give the highest transconductance gain until limited by area, stability (Harrison and Charles 2003) or signal attenuation due to high input capacitance (Denison et al 2007).”
BackgroundInfluentialSelf-citationAn Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376 · cited 1×
“The damage caused by the circuitry must be limited not only during normal operation but also upon failure of a component (Grimnes and Martinsen 2000). Clinical implants pass rigorous examination of all single-fault scenarios. The amplifier papers reviewed here do not discuss this concern although Liu et al (2007c) did…”
BackgroundReconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 375
A 128 x 128 cmos biosensor array for extracellular recording of neural activity
Eversmann, B., Jenkner, M., Hofmann, F., Paulus, C., Brederlow, R., Holzapfl, B., Fromherz, P., Merz, M., Brenner, M., Schreiter, M., et al. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.819174 · Cited by 375 · cited 3×
“An accurate gain is obtained from the ratio of two transconductances (Najafi and Wise 1986, Eversmann et al 2003, Gosselin et al 2003, Irazoqui-Pastor et al 2003) or the ratio of integrated resistors (Perelman and Ginosar 2006).”
BackgroundMethodSpike Detection Using the Continuous Wavelet Transform
Nenadic, Z., & Burdick, J. W. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839800 · Cited by 375 · cited 1×
“The high-frequency filter corner is commonly either 3 kHz or 5 kHz in neuroscience research, but higher corners, even beyond 10 kHz (Nenadic and Burdick 2005), may be used to inspect fine details of the average of many EAPs.”
BackgroundDrake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Electrical Interactions via the Extracellular Potential Near Cell Bodies
Holt, G. R., & Koch, C. (1999) · Journal of Computational Neuroscience · doi:10.1023/a:1008832702585 · Cited by 354
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Predicting Movement from Multiunit Activity
Stark, E., & Abeles, M. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1321-07.2007 · Cited by 309 · cited 2×
“The amplifiers presented here are also suitable for MUA (Stark and Abeles 2007) because MUA and EAPs occupy a similar frequency band from approximately 500 to 5000 Hz.”
BackgroundGesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. H. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 301 · cited 2×
“Representative probe noise spectra are measured in Gesteland et al (1959), Najafi and Wise (1986), Mohseni and Najafi (2004) and Liu et al (2007b).”
BackgroundMethodMethods for NEURAL ENSEMBLE RECORDINGS
(1998) · CRC Press eBooks · doi:10.1201/9781420048254 · Cited by 285
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
Primary Motor Cortex Tuning to Intended Movement Kinematics in Humans with Tetraplegia
Truccolo, W., Friehs, G. M., Donoghue, J. P., & Hochberg, L. R. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4415-07.2008 · Cited by 272
A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271 · cited 3×
“Switching circuits work well with low-impedance large probes (Denison et al 2007, Yazicioglu et al 2008).”
Microelectrode studies of the electrical activity of the cerebral cortex in the cat*
Li, C.-L., & Jasper, H. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004935 · Cited by 269 · cited 1×
“Large amplitude EAPs are found near large neurons, such as layer 5 pyramidal cells (Li and Jasper 1953).”
BackgroundChronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 262
Amplitude Variability and Extracellular Low-Pass Filtering of Neuronal Spikes
Pettersen, K. H., & Einevoll, G. T. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.111179 · Cited by 255
Fever, febrile seizures and epilepsy
Dubé, C. M., Brewster, A. L., Richichi, C., Zha, Q., & Baram, T. Z. (2007) · Trends in Neurosciences · doi:10.1016/j.tins.2007.07.006 · Cited by 238 · cited 1×
“Kim et al (2007c) analysed the magnitude of the temperature rise, but few researchers have analysed the effects of the temperature rise (Dube et al 2007, Wolf 2007).”
BackgroundAn Integrated Field-Effect Electrode for Biopotential Recording
Matsuo, T., & Wise, K. D. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324338 · Cited by 235 · cited 1×
“Momentarily shorting the probe to ground via a ‘reset’ switch (Najafi and Wise 1986, Lund 1996, Bai and Wise 2001) will return the probe voltage to a safe value but may still permit a net dc current and may interfere with other channels.”
BackgroundA 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225
Wireless multichannel biopotential recording using an integrated FM telemetry circuit
Mohseni, P., Najafi, K., Eliades, S. J., & Wang, X. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.853625 · Cited by 219
Variability of extracellular spike waveforms of cortical neurons
Fee, M. S., Mitra, P. P., & Kleinfeld, D. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.76.6.3823 · Cited by 218
Dielectric spectroscopy and conductivity of polyelectrolyte solutions
Bordi, F., Cametti, C., & Colby, R. H. (2004) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/16/49/r01 · Cited by 218
Single-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 215 · cited 2×
“Momentarily shorting the probe to ground via a ‘reset’ switch (Najafi and Wise 1986, Lund 1996, Bai and Wise 2001) will return the probe voltage to a safe value but may still permit a net dc current and may interfere with other channels.”
BackgroundNeuroprosthetics : Theory and Practice
Horch, K., & Dhillon, G. S. (2004) · doi:10.1142/4987#t=toc · Cited by 215
Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain
Kim, S., Tathireddy, P., Normann, R. A., & Solzbacher, F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908429 · Cited by 214
Enabling Technologies for Cultured Neural Networks
Stenger, D. A., & McKenna, T. M. (1994) · Cited by 214
A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity
Eversmann, B., Jenkner, M., Paulus, C., Hofmann, F., Brederlow, R., Holzapfl, B., Fromherz, P., Brenner, M., Schreiter, M., Gabl, R., et al. (2003) · 2003 IEEE International Solid-State Circuits Conference, 2003. Digest of Technical Papers. ISSCC. · doi:10.1109/isscc.2003.1234276 · Cited by 212 · cited 4×
“An accurate gain is obtained from the ratio of two transconductances (Najafi and Wise 1986, Eversmann et al 2003, Gosselin et al 2003, Irazoqui-Pastor et al 2003) or the ratio of integrated resistors (Perelman and Ginosar 2006).”
BackgroundMethodInfluentialAkin, T., Najafi, K., & Bradley, R. M. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.654942 · Cited by 207 · cited 1×
“In a fully differential circuit (Akin et al 1998, Charles and Harrison 2003, Chae et al 2008), the devices come in matched pairs, and signals are the difference in voltage between matched nodes.”
BackgroundImplantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202 · cited 2×
“…1974, Kipke et al 2004, Yoshida and Struijk 2004, Passeraub and Thakor 2005), in papers (Robinson 1968, Wise et al 1970, Wise and Angell 1975, Najafi 1994, McAdams and Jossinet 1996, Merrill et al 2005, Cheung 2007, Harrison 2007a) and in an easily read textbook by Grimnes and Martinsen (2000).”
BackgroundA Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction
Gosselin, B., Ayoub, A. E., Roy, J.-F., Sawan, M., Lepore, F., Chaudhuri, A., & Guitton, D. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2013718 · Cited by 202
Comprehensive study of noise processes in electrode electrolyte interfaces
Hassibi, A., Navid, R., Dutton, R. W., & Lee, T. H. (2004) · Journal of Applied Physics · doi:10.1063/1.1755429 · Cited by 199
MRI and implanted medical devices: basic interactions with an emphasis on heating
Nyenhuis, J. A., Park, S.-M., Kamondetdacha, R., Amjad, A., Shellock, F. G., & Rezai, A. R. (2005) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2005.859033 · Cited by 199
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
CMOS microelectrode array for the monitoring of electrogenic cells
Heer, F., Franks, W., Blau, A., Taschini, S., Ziegler, C., Hierlemann, A., & Baltes, H. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.006 · Cited by 181
A 100-channel system for real time detection and storage of extracellular spike waveforms
Guillory, K. S., & Normann, R. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00076-x · Cited by 180 · cited 1×
“A highpass filter of up to fifth order (Guillory and Normann 1999) may be needed to thoroughly remove the power-line signal.”
BackgroundA Low-Power Integrated Bioamplifier With Active Low-Frequency Suppression
Gosselin, B., Sawan, M., & Chapman, C. A. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.914490 · Cited by 174
Portable cell-based biosensor system using integrated CMOS cell-cartridges
DeBusschere, B. D., & Kovacs, G. T. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00168-3 · Cited by 174
Multiple microelectrode-recording system for human intracortical applications
Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00330-2 · Cited by 173
A Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173
An implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 173 · cited 1×
“The two devices may be seriesconnected diodes (Ji and Wise 1992) or transistors (Olsson et al 2005, Holleman and Otis 2007) or parallel-connected diodes (Takahashi and Matsuo 1984, Dorman et al 1985, Nielsen and Lehmann 2003) or transistors (Frey et al 2007).”
BackgroundModel-based analysis of cortical recording with silicon microelectrodes
Moffitt, M. A., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.05.018 · Cited by 170
Scaling limitations of silicon multichannel recording probes
Najafi, K., Ji, J., & Wise, K. D. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43605 · Cited by 163
Primate Reaching Cued by Multichannel Spatiotemporal Cortical Microstimulation
Fitzsimmons, N. A., Drake, W., Hanson, T. L., Lebedev, M. A., & Nicolelis, M. A. L. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5297-06.2007 · Cited by 163
A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology
Wise, K. D., & Angell, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324562 · Cited by 157 · cited 1×
“A low-noise source-follower circuit using junction field effect transistors (Wise and Angell 1975) eliminates the interaction of probe impedance and bipolar base current but these transistors are available in few modern processes (Takao et al 2008).”
BackgroundA Versatile Integrated Circuit for the Acquisition of Biopotentials
Harrison, R. R. (2007) · 2007 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2007.4405694 · Cited by 156 · cited 5×
“Sometimes, the negative inputs to the amplifiers exit the integrated circuit individually to connect to separate reference probes (Harrison 2007a, DeMichele and Troyk 2003a, Perelman and Ginosar 2006).”
BackgroundMethodInfluentialA low-power, low-noise CMOS amplifier for neural recording applications
Harrison, R. R. (2003) · 2002 IEEE International Symposium on Circuits and Systems. Proceedings (Cat. No.02CH37353) · doi:10.1109/iscas.2002.1010674 · Cited by 155 · cited 3×
“The gate width should be maximized to give the highest transconductance gain until limited by area, stability (Harrison and Charles 2003) or”
BackgroundInfluentialPredicted current densities in the brain during transcranial electrical stimulation
Holdefer, R. N., Sadleir, R., & Russell, M. J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.02.020 · Cited by 154
A floating metal microelectrode array for chronic implantation
Musallam, S., Bak, M. J., Troyk, P. R., & Andersen, R. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.005 · Cited by 149
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W., Carlson, D., Jensen, R., Stanslaski, S., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 143 · cited 1×
“The recording of EEG or ECoG is best done by amplifiers outside the scope of this review (Avestruz et al 2008).”
Self-citationThe Development of Brain-Machine Interface Neuroprosthetic Devices
Patil, P. G., & Turner, D. A. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.002 · Cited by 140
Eliasmith, C. (2002) · Cited by 138
Tissue Damage by Pulsed Electrical Stimulation
Butterwick, A., Vankov, A., Huie, P., Freyvert, Y., & Palanker, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908310 · Cited by 136
Computer control using human intracortical local field potentials
Kennedy, P. R., Kirby, M. T., Moore, M. M., King, B., & Mallory, A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.834629 · Cited by 134
CMOS Microelectrode Array for Bidirectional Interaction With Neuronal Networks
Heer, F., Hafizovic, S., Franks, W., Blau, A., Ziegler, C., & Hierlemann, A. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.873677 · Cited by 133
Integrated sensors, MEMS, and microsystems: Reflections on a fantastic voyage
Wise, K. D. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.02.013 · Cited by 133
Otto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 131
Kewley, D. T., Hills, M. D., Borkholder, D. A., Opris, I. E., Maluf, N. I., Storment, C. W., Bower, J. M., & Kovacs, G. T. A. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80221-x · Cited by 131 · cited 4×
“An amplifier with low dc gain can amplify both the EAP and the probe dc voltage without saturating its output stage (Kewley et al 1997, Irazoqui-Pastor et al 2003, Berdondini et al 2005), whereas high dc gain may cause saturation (Heer et al 2004).”
BackgroundInfluentialCeramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378400 · Cited by 129
Indwelling Neural Implants: Strategies for Contending with the In Vivo Environment
(2007) · CRC Press eBooks · doi:10.1201/9781420009309 · Cited by 129
Pancrazio, J. J., Gray, S. A., Shubin, Y. S., Kulagina, N. V., Cuttino, D. S., Shaffer, K. M., Eisemann, K., Curran, A., Zim, B., Gross, G. W., et al. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00092-7 · Cited by 127
Toward the ultimate metal microelectrode
Loeb, G. E., Peck, R. A., & Martyniuk, J. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00107-7 · Cited by 126
High-density electrode array for imaging in vitro electrophysiological activity
Berdondini, L., van der Wal, P. D., Guenat, O. T., de Rooij, N. F., Koudelka‐Hep, M., Seitz, P., Kaufmann, R., Metzler, P., Blanc, N., & Rohr, S. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.011 · Cited by 126 · cited 2×
“An amplifier with low dc gain can amplify both the EAP and the probe dc voltage without saturating its output stage (Kewley et al 1997, Irazoqui-Pastor et al 2003, Berdondini et al 2005), whereas high dc gain may cause saturation (Heer et al 2004).”
BackgroundNeural Prostheses for Restoration of Sensory and Motor Function
(2000) · CRC Press eBooks · doi:10.1201/9781420039054 · Cited by 122 · cited 1×
“While most aspects of multiple neuron recording have been covered in several anthologies (Chapin and Moxon 2000, Finn and LoPresti 2003, Horch and Dhillon 2004, He 2005, DiLorenzo and Bronzino 2007), amplifiers have not been surveyed thoroughly.”
BackgroundCharacteristics of the Metal-Tissue Interface of Stimulation Electrodes
Dymond, A. M. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324585 · Cited by 121
Design of a CMOS Potentiostat Circuit for Electrochemical Detector Arrays
Ayers, S., Gillis, K. D., Lindau, M., & Minch, B. A. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2006.888777 · Cited by 121 · cited 1×
“Ayers et al (2007) share one branch of the differential amplifier among all the channels to almost reach the performance of a single supply branch.”
BackgroundLocal field potential spectral tuning in motor cortex during reaching
Heldman, D. A., Wang, W., Chan, S. S., & Moran, D. W. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875549 · Cited by 120 · cited 3×
“However, the term electromagnetic interference (EMI) is commonly applied to electric, magnetic or electromagnetic fields.”
BackgroundMethodPerelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116
Acid Sensing Ion Channels in Dorsal Spinal Cord Neurons
Baron, A., Voilley, N., Lazdunski, M., & Lingueglia, É. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.4975-07.2008 · Cited by 114 · cited 1×
“The type of damage may be as severe as necrosis (Beard et al 1992) or as subtle as altered neural signals (Davenport et al 2008, Baron et al 2008).”
BackgroundA Sub-Microwatt Low-Noise Amplifier for Neural Recording
Holleman, J., & Otis, B. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353193 · Cited by 111
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Davenport, C. M., Detwiler, P. B., & Dacey, D. M. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.2735-07.2008 · Cited by 103
Wiltschko, A. B., Gage, G. J., & Berke, J. D. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.05.016 · Cited by 102
A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications
Patterson, W. R., Song, Y.-K., Bull, C. W., Ozden, I., Deangellis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Donoghue, J. D., & Connors, B. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831521 · Cited by 100
Optimizing recording capabilities of the Utah Intracortical Electrode Array
Nordhausen, C. T., Rousche, P. J., & Normann, R. A. (1994) · Brain Research · doi:10.1016/0006-8993(94)91213-0 · Cited by 100
The electrical activity of single units in the cerebral cortex of man
Ward, A. A., & Thomas, L. B. (1955) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(55)90067-5 · Cited by 100 · cited 2×
“Extracellular action potentials (EAPs) were first measured in humans in 1955 (Ward and Thomas 1955, as cited in Garrell (1998)).”
BackgroundStimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
Relaxation processes due to the electrode-electrolyte interface in ionic solutions
Sanabria, H., & Miller, J. H. (2006) · Physical Review E · doi:10.1103/physreve.74.051505 · Cited by 94 · cited 2×
“However, the term electromagnetic interference (EMI) is commonly applied to electric, magnetic or electromagnetic fields.”
BackgroundCochlear nucleus auditory prostheses
McCreery, D. B. (2008) · Hearing Research · doi:10.1016/j.heares.2007.11.014 · Cited by 93
A low-power CMOS neural amplifier with amplitude measurements for spike sorting
Horiuchi, T., Swindell, T., Sander, D., & Abshier, P. (2004) · 2004 IEEE International Symposium on Circuits and Systems (IEEE Cat. No.04CH37512) · doi:10.1109/iscas.2004.1328932 · Cited by 89
A miniaturized neuroprosthesis suitable for implantation into the brain
Mojarradi, M. M., Binkley, D. M., Blalock, B. J., Andersen, R. A., Ulshoefer, N., Johnson, T., & Castillo, L. D. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.810431 · Cited by 88
Two multichannel integrated circuits for neural recording and signal processing
Obeid, I., Morizio, J. C., Moxon, K. A., Nicolelis, M. A. L., & Wolf, P. D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.807643 · Cited by 85
Self-citationEvaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84 · cited 3×
“Circuits by Liu et al (2006a) and Wattanapanitch et al (2007) arrange the biasing of the additional branches such that noise and power dissipation are minimized.”
BackgroundMethodProblems in equivalent circuit modelling of the electrical properties of biological tissues
McAdams, E. T., & JOSSINET, J. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(96)05069-6 · Cited by 83
Chronic Electrical Stimulation of the Auditory Nerve using Non-charge-balanced Stimuli
Shepherd, R. K. (1999) · Acta Oto-Laryngologica · doi:10.1080/00016489950180621 · Cited by 81 · cited 1×
“The dc current restrictions placed on larger probes—for example, 100 nA on a 0.4 mm2 cochlear electrode (Shepherd et al 1999)—if scaled linearly with area, would limit current to the 100 pA range for intracortical microprobes.”
BackgroundInfluentialDesign of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78
Pancrazio, J. J., Bey, P. P., Loloee, A., SUBBARAOMANNE, Chao, H.-C., Howard, L. L., Gosney, W. M., Borkholder, D. A., Kovacs, G. T. A., Manos, P., et al. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00006-2 · Cited by 77
Sensing methods for dielectrophoresis phenomenon: from bulky instruments to lab-on-a-chip
Ghallab, Y. H., & Badawy, W. M. (2004) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2004.1337805 · Cited by 77
An integrated system for simultaneous, multichannel neuronal stimulation and recording.
Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2007.906071 · Cited by 74 · cited 3×
“…in the previous two paragraphs, some papers with measured results and a notable compromise of noise, power and area are Hills et al (2002), Harrison et al (2006), Parthasarathy et al (2006), Blum et al (2007), Gosselin et al (2007a), Wattanapanitch et al (2007) and Yin and Ghovanloo (2007).”
BackgroundActive microelectrode array to record from the mammalian central nervous systemin vitro
Jobling, D. T., Smith, J. G., & Wheal, H. V. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442768 · Cited by 71
Rizk, M., Obeid, I., Callender, S. H., & Wolf, P. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/016 · Cited by 71
Self-citationSong, Y., Patterson, W. R., Bull, C. W., Beals, J., Hwang, N.-J., Deangelis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Fellows, M. R., et al. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848337 · Cited by 71
Harmonic analysis of low-frequency bioelectrode behavior
Richardot, A., & McAdams, E. T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.800576 · Cited by 71
Solid-state microsensors for cortical nerve recordings
Najafi, K. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.294009 · Cited by 68 · cited 1×
“…1974, Kipke et al 2004, Yoshida and Struijk 2004, Passeraub and Thakor 2005), in papers (Robinson 1968, Wise et al 1970, Wise and Angell 1975, Najafi 1994, McAdams and Jossinet 1996, Merrill et al 2005, Cheung 2007, Harrison 2007a) and in an easily read textbook by Grimnes and Martinsen…”
BackgroundHandbook of Neuroprosthetic Methods
Finn, W. E., & LoPresti, P. G. (2002) · CRC Press eBooks · doi:10.1201/9781420040876 · Cited by 68
Challenges and constraints in designing implantable medical ICs
Gerrish, P., Herrmann, E., Tyler, L., & Walsh, K. A. (2005) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2005.858914 · Cited by 68
Neuronal Ensembles Strategies for Recording and Decoding
Eichenbaum, H. (2000) · International Journal of Neural Systems · doi:10.1016/s0129-0657(00)00040-5 · Cited by 66
N-Channel field-effect transistors with floating gates for extracellular recordings
Meyburg, S., Goryll, M., Moers, J., Ingebrandt, S., Böcker-Meffert, S., Luth, H., & Offenhäusser, A. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.010 · Cited by 61
Cohen, A., Spira, M. E., Yitshaik, S., Borghs, G., Shwartzglass, O., & Shappir, J. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.021 · Cited by 60 · cited 1×
“Patients or medical personnel with a neuroprosthetic will have to take the appropriate precautions.”
BackgroundCellular Phone Interference Testing of Implantable Cardiac Defibrillators In Vitro
Bassen, H., Moore, H. J., & Ruggera, P. S. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb00268.x · Cited by 60 · cited 1×
“Lowerstrength sources such as household appliances (Leitgeb 2008a), metal-detecting security systems (Kainz et al 2005) and cellular phones (Bassen et al 1998) impart internal electric fields that are either too small or too localized to overwhelm an implanted amplifier designed for EAPs.”
BackgroundDąbrowski, W., Gryboś, P., & Litke, A. M. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.08.005 · Cited by 59
Brain–Silicon Interface for High-Resolution in vitro Neural Recording
Aziz, J. N. Y., Genov, R., Bardakjian, B. L., Derchansky, M., & Carlen, P. L. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893181 · Cited by 58 · cited 1×
“…signal is conceptually identical to various offset-cancelling techniques such as autozeroing (Chan et al 2007), correlated double sampling (Aziz et al 2007b) or regulating the output dc voltage via a digital-to-analogue converter (Mojarradi et al 2003, Guo et al 2004, Jochum et al 2005,…”
BackgroundThe Dependence of Spectral Impedance on Disc Microelectrode Radius
Ahuja, A. K., Behrend, M. R., Whalen, J. J., Humayun, M. S., & Weiland, J. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912430 · Cited by 58 · cited 3×
“However, the term electromagnetic interference (EMI) is commonly applied to electric, magnetic or electromagnetic fields.”
BackgroundSilicon neural recording arrays with on-chip electronics for in-vivo data acquisition
Olsson, R. H., Gulari, M. N., & Wise, K. D. (2003) · 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578) · doi:10.1109/mmb.2002.1002321 · Cited by 55 · cited 4×
“Traditionally, the gain of a feedback amplifier is the ratio of two resistors, but the noise of the resistors is eliminated if they are replaced by capacitors (Olsson et al 2002).”
BackgroundMethodInfluentialIn-vivo EEG recording using a wireless implantable neural transceiver
Irazoqui-Pastor, P., Módy, I., & Judy, J. W. (2004) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196905 · Cited by 55 · cited 2×
“An amplifier with low dc gain can amplify both the EAP and the probe dc voltage without saturating its output stage (Kewley et al 1997, Irazoqui-Pastor et al 2003, Berdondini et al 2005), whereas high dc gain may cause saturation (Heer et al 2004).”
BackgroundMethodTakahashi, H., Ejiri, T., Nakao, M., Nakamura, N., Kaga, K., & Hervé, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.809483 · Cited by 55
Thermal Considerations for the Design of an Implanted Cortical Brain–Machine Interface (BMI)
(2007) · Indwelling Neural Implants · doi:10.1201/9781420009309-11 · Cited by 53
Moulin, C., Gliere, A., Barbier, D., Joucla, S., Yvert, B., Mailley, P., & Guillemaud, R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.903522 · Cited by 53
He, B. (2005) · Bioelectric engineering · doi:10.1007/b112182 · Cited by 51
Low?Power Architectures for Spike Sorting
Zviagintsev, A., Perelman, Y., & Ginosar, R. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419579 · Cited by 50
Implantable telemeter for long-term electroneurographic recordings in animals and humans
Donaldson, N., Zhou, L., Perkins, T. A., Munih, M., Haugland, M. K., & Sinkjær, T. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02349973 · Cited by 50
Nyquist interpolation improves neuron yield in multiunit recordings
Blanche, T. J., & Swindale, N. V. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.12.031 · Cited by 49
Takahashi, K., & Matsuo, T. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)87009-2 · Cited by 47 · cited 2×
“The two devices may be seriesconnected diodes (Ji and Wise 1992) or transistors (Olsson et al 2005, Holleman and Otis 2007) or parallel-connected diodes (Takahashi and Matsuo 1984, Dorman et al 1985, Nielsen and Lehmann 2003) or transistors (Frey et al 2007).”
BackgroundAn Integrated CMOS Bio-potential Amplifier with a Feed-Forward DC Cancellation Topology
Parthasarathy, J., Erdman, A. G., Redish, A. D., & Ziaie, B. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259577 · Cited by 45
Sprößler, C., Richter, D., Denyer, M. C. T., & Offenhäusser, A. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00016-5 · Cited by 45
Brain-Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9 · Cited by 44
Backside contacted field effect transistor array for extracellular signal recording
Ingebrandt, S., Yeung, C. K., Staab, W., Zetterer, T., & Offenhäusser, A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00155-0 · Cited by 44
Parametric modeling of somatosensory evoked potentials using discrete cosine transform
Bai, O., Nakamura, M., Nagamine, T., & Shibasaki, H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959331 · Cited by 40
Song, Y., Patterson, W. R., Bull, C. W., Borton, D. A., Li, Y., Nurmikko, A. V., Simeral, J. D., & Donoghue, J. P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352319 · Cited by 40
A new dc baseline stabilization scheme for neural recording microprobes
Chandran, A., Najafi, K., & Wise, K. D. (2003) · doi:10.1109/iembs.1999.802463 · Cited by 39
High-density microelectrode arrays for electrophysiological activity imaging of neuronal networks
Berdondini, L., Overstolz, T., de Rooij, N. F., Koudelka‐Hep, M., Wäny, M., & Seitz, P. (2002) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2001.957439 · Cited by 39
Kainz, W., Casamento, J. P., Ruggera, P. S., Chan, D. D., & Witters, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.843293 · Cited by 39 · cited 1×
“Lowerstrength sources such as household appliances (Leitgeb 2008a), metal-detecting security systems (Kainz et al 2005) and cellular phones (Bassen et al 1998) impart internal electric fields that are either too small or too localized to overwhelm an implanted amplifier designed for EAPs.”
BackgroundSchuettler, M. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352254 · Cited by 37
Integrated CMOS Amplifier for ENG Signal Recording
Uranga, A., Navarro, X., & Barniol, N. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.834253 · Cited by 37
A microprobe with integrated amplifiers for neurophysiology
Wise, K. D., & Angell, J. B. (1971) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.1971.1154991 · Cited by 37 · cited 1×
“Ken Wise not only designed the first amplifier (Wise and Angell 1971)3 but also mentored many of the pioneers in the field.”
BackgroundELECTRODE MATERIALS FOR RECORDING AND STIMULATION
Stieglitz, T. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0015 · Cited by 37 · cited 1×
“The probe itself also must recover and some probe materials, titanium nitride for example, are quicker than others (Stieglitz 2004).”
BackgroundA Low-Voltage Low-Noise CMOS Instrumentation Amplifier-for Portable Medical Monitoring Systems
Wu, H., & Xu, Y. P. (2005) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas.2005.1496659 · Cited by 37 · cited 1×
“Simulation of the circuit will not estimate the true performance unless mismatch of elements is considered (Wu and Xu 2005).”
BackgroundA monolithic signal processor for a neurophysiological telemetry system
DORMAN, M. G., PRISBE, M., & MEINDL, J. D. (1985) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1985.1052457 · Cited by 36
Identifying and reducing noise in psychophysiological recordings
Cutmore, T. (1999) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(99)00014-8 · Cited by 35
Analog frontend for multichannel neuronal recording system with spike and LFP separation
Perelman, Y., & Ginosar, R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.09.017 · Cited by 34
A simple method for efficient spike detection in multiunit recordings
Borghi, T., Gusmeroli, R., Spinelli, A. S., & Baranauskas, G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.02.014 · Cited by 34
A Practical Approach to Electrode-Skin Impedance Unbalance Measurement
Spinelli, E. M., Mayosky, M. A., & Pallas-Areny, R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875714 · Cited by 34
CMOS Front-end Amplifier Dedicated to Monitor Very Low Amplitude Signal from Implantable Sensors
Hu, Y., & Sawan, M. (2002) · Analog Integrated Circuits and Signal Processing · doi:10.1023/a:1020380912251 · Cited by 34
Thermal Considerations for the Design of an Implanted Cortical Brain–Machine Interface (BMI)
Wolf, P. D. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.ch3 · Cited by 34
Self-citationMohseni, P., & Najafi, K. (2002) · doi:10.1109/iembs.2002.1053193 · Cited by 33 · cited 1×
“Measurements of the problems discussed above must be done either with actual probes in a saline bath or some substitute for the probe impedance (Mohseni and Najafi 2002).”
BackgroundBiocompatibility considerations at stimulating electrode interfaces
Beard, R. B., Hung, B. N., & Schmukler, R. E. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368539 · Cited by 33 · cited 1×
“The type of damage may be as severe as necrosis (Beard et al 1992) or as subtle as altered neural signals (Davenport et al 2008, Baron et al 2008).”
BackgroundIntegrated multichannel wireless biotelemetry system
DeMichele, G. A., & Troyk, P. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280868 · Cited by 33
Zhou, D. M., & Greenberg, R. J. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279831 · Cited by 32
Kim, D., Richardson-Burns, S. M., Povlich, L. K., Abidian, M. R., Spanninga, S. A., Hendricks, J. L., & Martin, D. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.ch7 · Cited by 32
CMOS monolithic microelectrode array for stimulation and recording of natural neural networks
Franks, W., Heer, F., McKay, I., Taschini, S., Sunier, R., Hagleitner, C., Hierlemann, A. R., & Baltes, H. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216927 · Cited by 31
Low-Power Circuits for Brain-Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Rapoport, B. I., Arfin, S. K., Baker, M., Mandal, S., Fee, M. S., Musallam, S., & Andersen, R. A. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378505 · Cited by 31
Perlin, G. E., Sodagar, A. M., & Wise, K. D. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260193 · Cited by 30
Transcutaneous RF-powered neural recording device
Irazoqui-Pastor, P., Módy, I., & Judy, J. W. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053190 · Cited by 30
An adaptive ENG amplifier for tripolar cuff electrodes
Demosthenous, A., & Triantis, I. F. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.840957 · Cited by 30
Tracking Spike-Amplitude Changes to Improve the Quality of Multineuronal Data Analysis
Kaneko, H., Tamura, H., & Suzuki, S. S. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886934 · Cited by 30
Single-walled carbon nanotubes deposited on surface electrodes to improve interface impedance
Gabriel, G., Gómez, R., & Villa, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/6/s18 · Cited by 28
Hottowy, P., Dąbrowski, W., Skoczeń, A., & Wiacek, P. K. (2007) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-007-9125-x · Cited by 27 · cited 1×
“The circuit techniques that hasten the recovery are too diverse and complex for this review but can be found in recent papers (Gusmeroli et al 2006, Billoint et al 2007, Harrison 2007a, Brown et al 2008, Hottowy et al 2008).”
MethodOptimization of Microelectrode Design for Cortical Recording Based on Thermal Noise Considerations
Lempka, S. F., Johnson, M. D., Barnett, D. W., Moffitt, M. A., Otto, K. J., Kipke, D. R., & McIntyre, C. C. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259432 · Cited by 27
Stimulus-resistant neural recording amplifier
DeMichele, G. A., & Troyk, P. R. (2004) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1280857 · Cited by 26
256-Channel Neural Recording Microsystem with On-Chip 3D Electrodes
Aziz, J. N. Y., Genov, R., Derchansky, M., Bardakjian, B. L., & Carlen, P. L. (2007) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2007.373637 · Cited by 25 · cited 1×
“…signal is conceptually identical to various offset-cancelling techniques such as autozeroing (Chan et al 2007), correlated double sampling (Aziz et al 2007b) or regulating the output dc voltage via a digital-to-analogue converter (Mojarradi et al 2003, Guo et al 2004, Jochum et al 2005,…”
BackgroundTHE THEORY OF PERIPHERAL NERVE RECORDING
Yoshida, K., & Struijk, J. J. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0012 · Cited by 25 · cited 4×
“Although there are loose associations of physical mechanisms to each element, the model is empirical (McAdams and Jossinet 1996, Yoshida and Struijk 2004), and the parameters are found by curve fitting (Weiland and Anderson 2000, Otto et al 2006, Saha and Muthuswamy 2007).”
BackgroundMethodInfluentialA bio-amplifier with pulse output
Chen, D., Harris, J. G., & Príncipe, J. C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404136 · Cited by 24
A Compact Multichannel System for Acquisition and Processing of Neural Signals
Borghi, T., Bonfanti, A. G., Zambra, G., Gusmeroli, R., Spinelli, A. S., & Baranauskas, G. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352318 · Cited by 24
A Mixed-Signal Multi-Chip Neural Recording Interface with Bandwidth Reduction
Gosselin, B. J., Ayoub, A. E., & Sawan, M. (2007) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2007.4463306 · Cited by 23 · cited 6×
“Transconductance amplifiers can also serve as resistors (Harrison et al 2007b, Gosselin et al 2007b, Chan et al 2007).”
BackgroundInfluentialCurrent biased pseudo-resistor for implantable neural signal recording applications
Yuan, S., Johnson, L. G., Liu, C. C., Hutchens, C., & Rennaker, R. L. (2008) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2008.4616885 · Cited by 23 · cited 1×
“If the voltage is identical to that of a similar device that is conducting a properly selected current then the high resistance is independent of some manufacturing variations (Bai and Wise 2001, Hills et al 2002, Wang et al 2006, Ho et al 2007, Yuan et al 2008).”
BackgroundWireless Headstage for Neural Prosthetics
Morizio, J., Irazoqui, P. P., Go, V., & Parmentier, J. C. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419647 · Cited by 22
A Fully Integrated Fail-safe Stimulator Output Stage Dedicated to FES Stimulation
Liu, X., Demosthenous, A., & Donaldson, N. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378507 · Cited by 22 · cited 2×
“Representative probe noise spectra are measured in Gesteland et al (1959), Najafi and Wise (1986), Mohseni and Najafi (2004) and Liu et al (2007b).”
BackgroundMethodA Low-Power Bioamplifier With a New Active DC Rejection Scheme
Gosselin, B. J., Ayoub, A. E., & Sawan, M. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1693052 · Cited by 21
Models of stimulation artifacts applied to integrated circuit design
Blum, R. A., Ross, J. D., Das, S. K., Brown, E. A., & DeWeerth, S. P. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404137 · Cited by 21
Implantable stimulator and recording device for artificial prosthesis control
Sacristán, J., & Osés, M. T. (2007) · Microelectronics Journal · doi:10.1016/j.mejo.2007.10.003 · Cited by 20
Edell, D. J. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0016 · Cited by 20
Low-noise monolithic amplifier design: Bipolar versus CMOS
Steyaert, M. S. J., Chang, Z. Y., & Sansen, W. (1991) · Analog Integrated Circuits and Signal Processing · doi:10.1007/bf02151022 · Cited by 19
An Embedded System Architecture for Wireless Neural Recording
Farshchi, S., Pesterev, A. A., Guenterberg, E., Módy, I., & Judy, J. W. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369677 · Cited by 19
An implantable CMOS analog signal processor for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1990) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.1109/solsen.1990.109831 · Cited by 19
Signal Considerations for Chronically Implanted Electrodes for Brain Interfacing
Grill, W. M. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt2 · Cited by 18
Noise performance design of CMOS preamplifier for the active semiconductor neural probe
Kim, K. H., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855938 · Cited by 18
Effects of electrode size on the performance of neural recording microelectrodes
Hughes, M. P., Bustamante, K. D., Banks, D., & Ewins, D. J. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893776 · Cited by 17 · cited 1×
“The penalty for deviating from the optimum is small (Nordhausen et al 1994, Hughes et al 2000, Moffitt and McIntyre 2005), and other concerns such as tissue damage from large probes and signal attenuation from small probes should be factored into a practical design.”
BackgroundDesigning a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A. (2000) · doi:10.1201/9781420039054-13 · Cited by 17
Low-Power High-Resolution 32-channel Neural Recording System
Yun, X., Kim, D., Stanaćević, M., & Mainen, Z. F. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352804 · Cited by 16
Wireless, In Vivo Neural Recording using a Custom Integrated Bioamplifier and the Pico System
Cheney, D. J., Goh, A., Xu, J., Gugel, K., Harris, J. G., Sanchez, J. C., & Príncipe, J. C. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369601 · Cited by 15
An ultra low-power chopper stabilized front-end for multichannel cortical signals recording
Gosselin, B. J., Simard, V., & Sawan, M. (2004) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2004.1347696 · Cited by 15
A Microsystem Integration Platform Dedicated to Build Multi-Chip-Neural Interfaces
Ayoub, A. E., Gosselin, B. J., & Sawan, M. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353873 · Cited by 14 · cited 3×
“However, the advent of high-permittivity dielectrics (Venkateshan et al 2007) and stacked or ‘three-dimensional’ integrated circuits (Ayoub et al 2007, Jozwiak et al 2008) may restore the blocking capacitor to common practice.”
BackgroundAn implantable CMOS signal conditioning system for recording nerve signals with cuff electrodes
Papathanasiou, K., & Ehmann, T. L. (2002) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2000.857419 · Cited by 13
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“Recent works start to take full advantage of the unique abilities of HDMEAs.”
InfluentialMuller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
“A literature survey [8] confirms that it is difficult to scale the area of a Fig.”
BackgroundSwitch-Matrix-Based High-Density Microelectrode Array in CMOS Technology
Frey, U., Sedivy, J., Heer, F., Pedron, R., Ballini, M., Mueller, J., Bakkum, D., Hafizovic, S., Faraci, F. D., Greve, F., et al. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035196 · Cited by 251
“Integrated neuronal amplifiers [23] are used for two different applications.”
BackgroundChandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
“These issues make the pseudoresistor unreliable in a clinical setting [19].”
BackgroundDesign of Ultra-Low Power Biopotential Amplifiers for Biosignal Acquisition Applications
Zhang, F., Holleman, J., & Otis, B. P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177089 · Cited by 237
“Low-frequency local field potentials (LFPs) have amplitudes as high as 5 mV and may contain signal energy below 1 Hz [6], [7].”
BackgroundInfluential
Metadata
- Authors
- Jochum, T., Denison, T., & Wolf, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2009-01-12
- Volume
- 6
- Issue
- 1
- Pages
- 012001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2065682167
- Cited by
- 167
- References
- 238
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.