Activation of retinal ganglion cells following epiretinal electrical stimulation with hexagonally arranged bipolar electrodes
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We investigated retinal ganglion cell (RGC) responses to epiretinal electrical stimulation delivered by hexagonally arranged bipolar (Hex) electrodes, in order to assess the feasibility of this electrode arrangement for future retinal implant devices. In vitro experiments were performed using rabbit retinal preparations, with results compared to a computational model of axonal stimulation. Single-unit RGC responses to electrical stimulation were recorded with extracellular microelectrodes. With 100 µs/phase biphasic pulses, the threshold charge densities were 24.0 ± 11.2 and 7.7 ± 3.2 µC cm(-2) for 50 and 125 µm diameter Hex electrodes, respectively. Threshold profiles and response characteristics strongly suggested that RGC axons were the neural activation site. Both the model and in vitro data indicated that localized tissue stimulation is achieved with Hex electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Action potential generation requires a high sodium channel density in the axon initial segment
Kole, M. H. P., Ilschner, S. U., Kampa, B. M., Williams, S. R., Ruben, P. C., & Stuart, G. J. (2008) · Nature Neuroscience · doi:10.1038/nn2040 · Cited by 703
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159
Cited by
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
“The outer ring of stimulating electrodes was ganged together to allow investigation of the use of hexagonal stimulation [32], meaning that there were a total of 20 electrodes that could be individually stimulated (Fig.”
BackgroundSpatially patterned electrical stimulation to enhance resolution of retinal prostheses
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.2882-13.2014 · Cited by 103
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Computational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
Optimization of Electrical Stimulation for a High-Fidelity Artificial Retina
Shah, N. P., Madugula, S., Grosberg, L., Mena, G., Tandon, P., Hottowy, P., Sher, A., Litke, A., Mitra, S., & Chichilnisky, E. J. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8716987 · Cited by 32
“For example, the impact of different electrical stimulation patterns such as current steering [17], [19], [20] and local return [21], [22] can be directly compared by evaluating the quality of the final inferred visual image.”
BackgroundSpencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Esler, T. B., Kerr, R. R., Tahayori, B., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193598 · Cited by 28
“Experimental and simulation studies have shown that, given the distances between the electrode array and tissue that we consider here, the impact of an electrical double layer is negligible in magnitude as well as being both highly transient and highly spatially localized [18, 48, 49].”
Background
Metadata
- Authors
- Abramian, M., Lovell, N. H., Morley, J. W., Suaning, G. J., & Dokos, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-05-18
- Volume
- 8
- Issue
- 3
- Pages
- 035004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2055126043
- Cited by
- 52
- References
- 14
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.