High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of -58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s(-1). The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recordings from PNS neurons through a MCEA were later validated in rats in an acute setting.32”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [32]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 1×
“They operate by injecting current pulses to stimulate large populations of neurons in the vicinity of the electrode, thus transmitting information to the brain stem and cortex [1].”
BackgroundNeural Tissue Engineering: Strategies for Repair and Regeneration
Schmidt, C. E., & Leach, J. B. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.011303.120731 · Cited by 1,237
Microfluidic culture platform for neuroscience research
Park, J. W., Vahidi, B., Taylor, A. M., Rhee, S. W., & Jeon, N. L. (2006) · Nature Protocols · doi:10.1038/nprot.2006.316 · Cited by 464
Primary afferent units from the hairy skin of the rat hind limb
Lynn, B., & Carpenter, S. E. (1982) · Brain Research · doi:10.1016/0006-8993(82)90768-5 · Cited by 427
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 2×
“In a study employing a LIFE interface, signal amplitudes of ±40 μV and noise floor of ±20 μV before de-noising have been demonstrated [5].”
BackgroundMethodCORD CELLS RESPONDING TO TOUCH, DAMAGE, AND TEMPERATURE OF SKIN
Wall, P. D. (1960) · Journal of Neurophysiology · doi:10.1152/jn.1960.23.2.197 · Cited by 266
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 263
Self-citationOngoing activity in peripheral nerve: Injury discharge
Wall, P. D., Waxman, S., & Basbaum, A. I. (1974) · Experimental Neurology · doi:10.1016/0014-4886(74)90163-0 · Cited by 248
Controlling dispersion of axonal regeneration using a multichannel collagen nerve conduit
Yao, L., de Ruiter, G. C. W., Wang, H., Knight, A. M., Spinner, R. J., Yaszemski, M. J., Windebank, A. J., & Pandit, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.081 · Cited by 236
Extended cyclic uniaxial loading of stretchable gold thin-films on elastomeric substrates
Graz, I. M., Cotton, D. P. J., & Lacour, S. P. (2009) · Applied Physics Letters · doi:10.1063/1.3076103 · Cited by 234
Self-citationNeuroprosthetics : Theory and Practice
Horch, K., & Dhillon, G. S. (2004) · doi:10.1142/4987#t=toc · Cited by 215
Dworak, B. J., & Wheeler, B. C. (2009) · Lab Chip · doi:10.1039/b806689b · Cited by 158
Adrega, T., & Lacour, S. P. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/5/055025 · Cited by 157
Self-citationHai, A., Dormann, A., Shappir, J., Yitzchaik, S., Bartic, C., Borghs, G., Langedijk, J. P. M., & Spira, M. E. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0087 · Cited by 142
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 1×
“Cuff interfaces with enhanced selectivity such as FINEs (flat interface nerve electrodes) are currently in clinical trials [4].”
BackgroundMeacham, K., Giuly, R. J., Guo, L., Hochman, S., & DeWeerth, S. P. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9132-9 · Cited by 114
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Dermatome mapping in the rat hindlimb by electrical stimulation of the spinal nerves
Takahashi, Y., Nakajima, Y., & Sakamoto, T. (1994) · Neuroscience Letters · doi:10.1016/0304-3940(94)90422-7 · Cited by 95
Raspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
Self-citationLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75 · cited 1×
“It has been shown that parallel channels up to 5 mm long and with a 10 000 μm2 cross-sectional area support in vivo regeneration well [24].”
BackgroundSelf-citationRecording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays
Clark, G. A., Ledbetter, N. M., Warren, D. J., & Harrison, R. R. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091149 · Cited by 72
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68 · cited 1×
“They rely on a close proximity of the ring electrode to the axons and the corresponding nodes of Ranvier, therefore not all electrodes record equally well and are subject to cross-talk [6].”
BackgroundClaverol-Tinturé, E., Ghirardi, M., Fiumara, F., Rosell, X., & Cabestany, J. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/2/l01 · Cited by 64
Highly-compliant, microcable neuroelectrodes fabricated from thin-film gold and PDMS
McClain, M. A., Clements, I. P., Shafer, R. H., Bellamkonda, R. V., LaPlaca, M. C., & Allen, M. G. (2011) · Biomedical Microdevices · doi:10.1007/s10544-010-9505-3 · Cited by 63
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56
Microchannel Electrodes for Recording and Stimulation:In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45
Self-citationPeripheral Nerve Repair Through Multi-Luminal Biosynthetic Implants
Tansey, K. E., Seifert, J. L., Botterman, B. R., Delgado, M. R., & Romero‐Ortega, M. I. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0277-6 · Cited by 30
THE THEORY OF PERIPHERAL NERVE RECORDING
Yoshida, K., & Struijk, J. J. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0012 · Cited by 25
Impedance spectroscopy on stretchable microelectrode arrays
Minev, I. R., & Lacour, S. P. (2010) · Applied Physics Letters · doi:10.1063/1.3469919 · Cited by 20
Self-citationWatling, C. P., Lago, N., Benmerah, S., FitzGerald, J. J., Tarte, E. J., McMahon, S. B., Lacour, S. P., & Cameron, R. E. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.032 · Cited by 15
Self-citationWieringa, P. A., Wiertz, R. W. F., de Weerd, E. L., & Rutten, W. L. C. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038950 · Cited by 13
Research works printed but not linked: 1
- Clark G A Ledbetter N M Warren D J Harrison R R, 2011, 33rd Annu. Int. Conf. of the IEEE EMBS, 4641
Cited by
25th Anniversary Article: A Soft Future: From Robots and Sensor Skin to Energy Harvesters
Bauer, S., Bauer‐Gogonea, S., Graz, I., Kaltenbrunner, M., Keplinger, C., & Schwödiauer, R. (2014) · Advanced Materials · doi:10.1002/adma.201303349 · Cited by 860
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
“…neural interface devices, including ultra-compliant microelectrode arrays that insert into the epidural space and accommodate movement of the spinal cord (Minev et al., 2012; Minev et al., 2015), while providing essential recording and stimulating function in the context of regenerative medicine.”
BackgroundOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“The next level on selectivity and cross-talk reduction is the regenerative microchannel electrode, a combination between sieve and cuff electrodes that better isolates bundles of axons [87].”
BackgroundWare, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123
Self-citation
Metadata
- Authors
- Minev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P.
- Affiliations
- University of Cambridge (GB)
- École Polytechnique Fédérale de Lausanne (CH)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-02-13
- Volume
- 9
- Issue
- 2
- Pages
- 026005
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2168977771
- Cited by
- 36
- References
- 32
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 5 · 2019: 3 · 2018: 1 · 2017: 4 · 2015: 6 · 2014: 4 · 2013: 4 · 2012: 2
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Royal Society
- Engineering and Physical Sciences Research Council (EP/H00727X/1)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- neural prostheses, peripheral nerve interfaces, signal-to-noise ratio
- MeSH terms
- Animals, Dimethylpolysiloxanes, Electrodes, Implanted, Electrophysiology, Gold, Male, Microelectrodes, Neurons, Afferent, Peripheral Nerves, Physical Stimulation, Prosthesis Design, Robotics, Spinal Cord, User-Computer Interface, Reproducibility of Results, Electric Impedance, Rats, Sprague-Dawley, Rats, Neural Prostheses, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.