Is the time right for a redefinition of the second by optical atomic clocks?
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Given the dramatic rate of progress in optical atomic clocks over the last decade, this paper presents the current state of play, and considers the possibilities, implications and timescales for a potential redefinition of the SI second in terms of an optical reference transition. In particular, the question of choice of a future standard is addressed, together with the requirements to accurately compare realisations of such standards, both for clocks local to, and remote from each other. Current performances of various optical clock systems are examined and possibilities for moving beyond potential limitations by alternative strategies are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Efficient Atomic Clocks Operated with Several Atomic Ensembles
Borregaard, J., & Sørensen, A. S. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.090802 · Cited by 67
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Self-citation
Research works printed but not linked: 28
- 10.1109/TIM.2012.2228749 · DOI
- 10.1016/j.crhy.2015.03.002 · DOI
- 10.1109/TIM.2008.2007051 · DOI · Paper page
- 10.1063/1.3112574 · DOI · Paper page
- Szymaniec K, 2016, J. Phys.: Conf. Ser, 723, 10.1088/1742-6596/723/1/012003 · DOI
- 10.1103/PhysRevLett.104.070802 · DOI · Paper page
- 10.1103/PhysRevLett.112.173002 · DOI · Paper page
- 10.1103/PhysRevLett.116.013001 · DOI · Paper page
- 10.1103/PhysRevLett.114.230801 · DOI · Paper page
- 10.1103/PhysRevLett.103.063001 · DOI · Paper page
- 10.1103/PhysRevLett.107.203001 · DOI · Paper page
- Riehle F, 2016, Manuscript in preparation
- Johnson L A M, 2015, Metrologia, 52, 62, 10.1088/0026-1394/52/1/62 · DOI · Paper page
- 10.1364/OL.32.003056 · DOI · Paper page
- 10.1364/OE.18.016849 · DOI · Paper page
- 10.1016/j.crhy.2015.05.002 · DOI · Paper page
- Leute J, 2016, IEEE-Trans UFFC accepted
- 10.1038/522016a · DOI
- 10.1038/nphoton.2012.217 · DOI · Paper page
- 10.1038/nphoton.2013.174 · DOI · Paper page
- 10.1364/OE.18.001667 · DOI · Paper page
- 10.1038/nphoton.2011.215 · DOI · Paper page
- 10.1103/PhysRevLett.114.253902 · DOI · Paper page
- 10.1103/PhysRevLett.102.163601 · DOI · Paper page
- 10.1103/PhysRevA.79.061401 · DOI · Paper page
- 10.1126/science.1097576 · DOI · Paper page
- 10.1038/nature16176 · DOI · Paper page
- 10.1126/science.1192720 · DOI · Paper page
Cited by
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Self-citationRiehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Self-citationChronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
Absolute frequency measurement of the 88 Sr + clock transition using a GPS link to the SI second
Dubé, P., Bernard, J. E., & Gertsvolf, M. (2017) · Metrologia · doi:10.1088/1681-7575/aa5e60 · Cited by 28
Metadata
- Authors
- Gill, P.
- Venue
- Journal of Physics: Conference Series
- Publisher
- IOP Publishing
- Published
- 2016-06
- Volume
- 723
- Pages
- 012053
- ISSN
- 1742-6588 (ISSN-L)
- 1742-6596
- OpenAlex
- W2468461721
- Cited by
- 37
- References
- 8
- FWCI
- 22.03
- Type
- conference paper
- Language
- en
- Open access
- diamond
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is the time right for a redefinition of the second by optical atomic clocks? https://app.cochat.ai/papers/10.1088/1742-6596/723/1/012053
- The paper
- Gill, P. (2016). Is the time right for a redefinition of the second by optical atomic clocks? Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/723/1/012053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.