From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In the DexCom G4 Platinum (DG4P) continuous glucose monitoring (CGM) sensor, the raw current signal generated by glucose-oxidase is transformed to glucose concentration by a calibration function whose parameters are periodically updated by matching self-monitoring of blood glucose references, usually twice a day, to compensate for sensor variability in time. The aim of this work is to reduce DG4P calibration frequency to once a day by a recently proposed Bayesian calibration algorithm, which employs a time-varying calibration function and suitable day-specific priors. METHODS: The database consists of 57 CGM signals that are collected by the DG4P for 7 days. The Bayesian calibration algorithm is used to calibrate the raw current signal following two different schedules, that is, two and one calibration per day. Calibrated glycemic profiles are compared with those originally acquired by the manufacturer, on days 1, 4, and 7, where frequent blood glucose references were available, by using standard metrics, that is, mean absolute relative difference (MARD), percentage of accurate glucose estimates, and percentage of data in the A-zone of Clarke Error Grid. RESULTS: The one per day Bayesian calibration algorithm has accuracy similar to that of two per day (11.8% vs. 11.7% MARD, respectively), and it is statistically better (P-value of 0.0411) than the manufacturer calibration algorithm, which requires two calibrations per day (13.1% MARD). CONCLUSIONS: A Bayesian calibration algorithm employing a time-varying calibration function and suitable priors enables a reduction of the calibrations of DG4P sensor from two to one per day.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168 · cited 1×
“…glucose estimates (PAGE), calculated as the percentage of ( z k , x k ) pairs for which the relative distance is smaller than 20 (although other values are testable, this choice has the advantage of rendering our analysis in line with other recent papers considering DG4P accuracy 17,22,23 ).”
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Cited by
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“In a recent study of our group [64], we demonstrated that the number of calibrations can be reduced from two to one per day thanks to the use of the new calibrations functions that allow taking into account the variability in”
BackgroundSelf-citationContinuous glucose monitoring: Current use in diabetes management and possible future applications
Vettoretti, M., Cappon, G., Acciaroli, G., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818774078 · Cited by 96
“However, the CGM usability is rapidly improving because of increases in sensor accuracy,(25-32) extension of the sensor wear time, and decreases in calibration requirements.(33-37) Moreover, some CGM devices received regulatory approval for nonadjunctive use; that is, the patient can make treatment decisions without u…”
BackgroundCappon, G., Vettoretti, M., Marturano, F., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818759558 · Cited by 62
Self-citationClinical Implications of Accuracy Measurements of Continuous Glucose Sensors
Bailey, T. S. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0050 · Cited by 60
Metadata
- Authors
- Acciaroli, G., Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2016-08
- Volume
- 18
- Issue
- 8
- Pages
- 472-479
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2516748201
- Cited by
- 22
- References
- 3
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior. https://app.cochat.ai/papers/10.1089/dia.2016.0088
- The paper
- Acciaroli, G., Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016). From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2016.0088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).