Practical Considerations on the Use of Continuous Glucose Monitoring in Pediatrics and Older Adults and Nonadjunctive Use
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Clinical use of continuous glucose monitoring (CGM) devices has grown over the past 15 years from a niche concept to becoming standard of care for patients with type 1 diabetes (T1D). With the December 2016 Food and Drug Administration approval for diabetes treatment decisions directly from CGM values (nonadjunctive use) without finger-stick confirmation, the uptake and scope of CGM use will likely further expand. With this expansion, it is important to consider the role and impact of CGM technology in specific settings and high-risk populations, such as the young and the elderly. In pediatric patients, CGM concerns include limited body surface area, difficulty keeping sensors adhered, and the role of nonadjunctive use in the school setting. In older adults, Medicare did not, until very recently, cover CGM devices and as such, their use had been limited by lack of reimbursement. As CGM use will likely expand in clinical practice given the nonadjunctive indication, guidelines and recommendations for clinical practice are warranted. In this article, we discuss recent research on CGM use in the special populations of children and older adults and provide initial guidelines for nonadjunctive use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389 · cited 1×
“21,26 Schu¨tt et al. reported that patients with T1D > 60 years old had nearly twice the incidence of SH compared to younger T1D patients 27 ; the T1DX reported that patients > 65 years old had a high rate of SH (0.168 episodes/patient-year).”
InfluentialMiller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185 · cited 1×
“30 A recent survey of older adults using CGM reported better glycemic control with reduced hypoglycemia compared with those not using CGM. 31 The ability to monitor real-time glucose data and receive alerts regarding hypoglycemic events can aid in the management of T1D in older adults for the…”
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K. (2017) · Diabetes Care · doi:10.2337/dc16-1536 · Cited by 296 · cited 1×
“6.”
Incidence of type 1 and type 2 diabetes in adults and children in Kronoberg, Sweden
Thunander, M., Petersson, C., Jonzon, K., Fornander, J., Ossiansson, B., Torn, C., Edvardsson, S., & Landin-Olsson, M. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.07.022 · Cited by 218
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211
Hypoglycemia in Type 1 Diabetes Mellitus
Cryer, P. E. (2010) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2010.05.003 · Cited by 205
Altered Hierarchy of Protective Responses Against Severe Hypoglycemia in Normal Aging in Healthy Men
Matyka, K., Evans, M., Lomas, J., Cranston, I., Macdonald, I., & Amiel, S. A. (1997) · Diabetes Care · doi:10.2337/diacare.20.2.135 · Cited by 195 · cited 1×
“21,23 Older patients also have increased risk for severe hypoglycemia (SH), 24,25 with reduced capacity to detect and counter-regulate against SH. 25 SH is particularly dangerous in older patients, due to its association with risks for falls with injury, myocardial infarcts, arrhythmias, temporary…”
Mortality in type 1 diabetes in the DCCT/EDIC versus the general population
The Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) Study Research Group (2016) · Diabetes Care · doi:10.2337/dc15-2399 · Cited by 194
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168 · cited 6×
“However, the improved accuracy and reliability of CGM devices now approximate the accuracy range reported for BGM. 16 An FDA Advisory Board heard public testimony on July 21, 2016, and recommended that the Dexcom G5 Mobile device be approved for nonadjunctive use, a recommendation accepted by FDA on December 20, 2016.”
InfluentialSusceptibility of Interstitial Continuous Glucose Monitor Performance to Sleeping Position
Mensh, B. D., Wisniewski, N. A., Neil, B. M., & Burnett, D. R. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700408 · Cited by 97
Regulation Catches Up to Reality: Nonadjunctive Use of Continuous Glucose Monitoring Data
Edelman, S. V. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816667749 · Cited by 51
Cited by
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Self-citationAlva, S., Bailey, T., Brazg, R., Budiman, E. S., Castorino, K., Christiansen, M. P., Forlenza, G., Kipnes, M., Liljenquist, D. R., & Liu, H. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820958754 · Cited by 164
Self-citationContinuous glucose monitoring: Current use in diabetes management and possible future applications
Vettoretti, M., Cappon, G., Acciaroli, G., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818774078 · Cited by 96
“The use of CGM sensors is very beneficial for glycemic control, particularly for reducing HbA1c and the frequency of hypoglycemic events,7-11 and is potentially cost effective in terms of the ratio between costs and quality-adjusted lifeyears.12-15 Nevertheless, the distribution of CGM sensors has remained limited to…”
BackgroundLaffel, L. M., Aleppo, G., Buckingham, B. A., Forlenza, G. P., Rasbach, L. E., Tsalikian, E., Weinzimer, S. A., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00389 · Cited by 79
“We base our approach on previous algorithms used in clinical trials [19 – 21], our clinical experiences as endocrinolo-gists, and guidance from other diabetes specialists [23, 25, 26].”
MethodSelf-citationUse of Diabetes Technology in Children
Desrochers, H. R., Schultz, A. T., & Laffel, L. M. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.001 · Cited by 29
Self-citation
Metadata
- Authors
- Forlenza, G. P., Argento, N. B., & Laffel, L. M.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2017-06
- Volume
- 19
- Issue
- 3_suppl
- Pages
- S13-S20
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2623483025
- Cited by
- 44
- References
- 17
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.