The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Adolescents and Adults with Type 1 Diabetes
Open accessAbstract
Introduction: This trial assessed safety and effectiveness of an advanced hybrid closed-loop (AHCL) system with automated basal (Auto Basal) and automated bolus correction (Auto Correction) in adolescents and adults with type 1 diabetes (T1D). Materials and Methods: This multicenter single-arm study involved an intent-to-treat population of 157 individuals (39 adolescents aged 14–21 years and 118 adults aged ≥22–75 years) with T1D. Study participants used the MiniMed™ AHCL system during a baseline run-in period in which sensor-augmented pump +/− predictive low glucose management or Auto Basal was enabled for ∼14 days. Thereafter, Auto Basal and Auto Correction were enabled for a study phase (∼90 days), with glucose target set to 100 or 120 mg/dL for ∼45 days, followed by the other target for ∼45 days. Study endpoints included safety events and change in mean A1C, time in range (TIR, 70–180 mg/dL) and time below range (TBR, <70 mg/dL). Run-in and study phase values were compared using Wilcoxon signed-rank test or paired t -test. Results: Overall group time spent in closed loop averaged 94.9% ± 5.4% and involved only 1.2 ± 0.8 exits per week. Compared with run-in, AHCL reduced A1C from 7.5% ± 0.8% to 7.0% ± 0.5% (<0.001, Wilcoxon signed-rank test, n = 155), TIR increased from 68.8% ± 10.5% to 74.5% ± 6.9% (<0.001, Wilcoxon signed-rank test), and TBR reduced from 3.3% ± 2.9% to 2.3% ± 1.7% (<0.001, Wilcoxon signed-rank test). Similar benefits to glycemia were observed for each age group and were more pronounced for the nighttime (12 AM–6 AM). The 100 mg/dL target increased TIR to 75.4% ( n = 155), which was further optimized at a lower active insulin time (AIT) setting (i.e., 2 h), without increasing TBR. There were no severe hypoglycemic or diabetic ketoacidosis events during the study phase. Conclusions: These findings show that the MiniMed AHCL system is safe and allows for achievement of recommended glycemic targets in adolescents and adults with T1D. Adjustments in target and AIT settings may further optimize glycemia and improve user experience. Clinical Trial Registration number: NCT03959423.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“This finding supports previous studies demonstrating a correlation of %TIR with more aggressive correction targets.19 20”
From Clinical utility of the twiist Automated Insulin Delivery System: first study with twiist (2026) · cites this paper as [19]
The cited source says what the claim attributes to it.
In the citing paper
“Carlson et al reported no DKA or severe hypoglycemia events in a cohort of 39 adolescents and 118 adults using the MiniMed 780G system over a 3-month observation period.19”
From Clinical utility of the twiist Automated Insulin Delivery System: first study with twiist (2026) · cites this paper as [19]
The cited source says what the claim attributes to it.
In the citing paper
“Our results also showed safety outcomes that are comparable to other short-duration AID studies, showing no DKA or severe hypoglycemia events and very little time spent in level 1 and level 2 hypoglycemia.”
From Clinical utility of the twiist Automated Insulin Delivery System: first study with twiist (2026) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“The International Consensus on Use of Continuous Glucose Monitoring recommended standards for reporting CGM metrics(14) and recommended goals for time spent across SG ranges.(15) Recommended percentages of time spent within 70–180 mg/dL, >180 mg/dL, and <70 mg/dL ranges (TIR, TAR, and TBR, respectively) have evolved t…”
MethodSelf-citationInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationState of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Self-citationMiller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644
Self-citationGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 1×
“The pivotal trials of the first Food and Drug Administrationapproved hybrid closed-loop therapy, the Medtronic MiniMed 670G system, demonstrated an increase in 24-h day and nighttime TIR, a reduction in TBR and TAR, and a lowered mean A1C when compared with open-loop use, in children,(16) adolescents, and adults.(17)…”
BackgroundSelf-citationLu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517
Self-citation
Cited by
Sorted by citations
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G. B., Polsky, R., Cunningham, D. D., Soh, H. T., & Heikenfeld, J. C. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 389
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Choudhary, P., Kolassa, R., Keuthage, W., Kroeger, J., Thivolet, C., Evans, M., Ré, R., de Portu, S., Vorrink, L., Shin, J., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00212-1 · Cited by 204
Self-citation14. Children and Adolescents: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D. M., Johnson, E. L., et al. (2022) · Diabetes Care · doi:10.2337/dc23-s014 · Cited by 224
14. Children and Adolescents: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s014 · Cited by 173
14. Children and Adolescents: Standards of Care in Diabetes—2024
ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., Lingvay, I., et al. (2023) · Diabetes Care · doi:10.2337/dc24-s014 · Cited by 192
7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 215
Arrieta, A., Battelino, T., Scaramuzza, A. E., Silva, J. D., Castañeda, J., Cordero, T. L., Shin, J., & Cohen, O. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14714 · Cited by 163
Self-citationISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Self-citationA Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Predictors of time in target glucose range in real‐world users of the MiniMed 780G system
Castañeda, J., Mathieu, C., Aanstoot, H., Arrieta, A., Silva, J. D., Shin, J., & Cohen, O. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14807 · Cited by 108
Self-citationPetrovski, G., Campbell, J., Pasha, M., Day, E., Hussain, K., Khalifa, A., & van den Heuvel, T. (2023) · Diabetes Care · doi:10.2337/dc22-1692 · Cited by 108
Castañeda, J., Arrieta, A., van den Heuvel, T., Battelino, T., & Cohen, O. (2024) · Diabetes Care · doi:10.2337/dc23-1581 · Cited by 107
Biester, T., Berget, C., Boughton, C. K., Cudizio, L., Ekhlaspour, L., Hilliard, M. E., Reddy, L., Sap, S. N. U., Schoelwer, M. J., Sherr, J. L., et al. (2024) · Hormone Research in Paediatrics · doi:10.1159/000543034 · Cited by 114
Self-citationForlenza, G. P., DeSalvo, D. J., Aleppo, G., Wilmot, E. G., Berget, C., Huyett, L. M., Hadjiyianni, I., Méndez, J. J., Conroy, L. R., Ly, T. T., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0578 · Cited by 99
Self-citationCrabtree, T. S. J., Griffin, T. P., Yap, Y. W., Narendran, P., Gallen, G., Furlong, N. J., CRANSTON, I. C., Chakera, A. J., Philbey, C., Karamat, M. A., et al. (2023) · Diabetes Care · doi:10.2337/dc23-0635 · Cited by 95
Yoo, J. H., & Kim, J. H. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0271 · Cited by 96
Choudhary, P., Arrieta, A., van den Heuvel, T. R. A., Castañeda, J., Smaniotto, V., & Cohen, O. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0433 · Cited by 83
The Artificial Pancreas and Type 1 Diabetes
Nwokolo, M., & Hovorka, R. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad068 · Cited by 99
Matejko, B., Juza, A., Kieć-Wilk, B., Cyranka, K., Krzyżowska, S., Chen, X., Cohen, O., Da Silva, J., Malecki, M. T., & Klupa, T. (2022) · Diabetes Care · doi:10.2337/dc22-0470 · Cited by 72
Self-citationSoft and Flexible Bioelectronic Micro‐Systems for Electronically Controlled Drug Delivery
Mariello, M., Eş, İ., & Proctor, C. M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202302969 · Cited by 70
Unannounced Meal Challenges Using an Advanced Hybrid Closed-Loop System
Shalit, R., Minsky, N. C., Laron-Hirsh, M., Cohen, O., Kurtz, N., Roy, A., Grosman, B., Benedetti, A., & Tirosh, A. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0139 · Cited by 64
Self-citationReal-world evidence of automated insulin delivery system use
Considine, E. G., & Sherr, J. L. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0442 · Cited by 59
Self-citationDigital Technology for Diabetes
Hughes, M. S., Addala, A., & Buckingham, B. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2215899 · Cited by 59
Grassi, B. A., Gómez, A. M., Calliari, L. E., Franco, D. R., Raggio, M., Riera, F., Castro, M., MCVEAN, J. J. F., van den Heuvel, T. R. A., Arrieta, A., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15023 · Cited by 58
Beato-Víbora, P. I., Chico, A. I., Moreno-Fernández, J., Bellido, V., Nattero‐Chávez, L., César, M. J. P., Martínez‐Brocca, M. A., Giménez, M., Aguilera, E., Climent, E., et al. (2023) · Diabetes Care · doi:10.2337/dc23-1355 · Cited by 57
Automated Insulin Delivery in Adults With Type 2 Diabetes
Pasquel, F. J., Davis, G. M., Huffman, D. M., Peters, A. L., Parker, J. C., Laffel, L. M., Romeo, G. R., Mathew, J. T., CASTORINO, K. N., Kruger, D. F., et al. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2024.59348 · Cited by 52
Self-citationAutomated insulin delivery systems: from early research to routine care of type 1 diabetes
Renard, É. (2022) · Acta Diabetologica · doi:10.1007/s00592-022-01929-5 · Cited by 50
Mariello, M., & Proctor, C. M. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400797 · Cited by 50
Borel, A.-L., Lablanche, S., Waterlot, C., Joffray, E., Barra, C., Arnol, N., Amougay, H., & Benhamou, P.-Y. (2024) · Diabetes Care · doi:10.2337/dc24-0623 · Cited by 43
Emerging Diabetes Technologies: Continuous Glucose Monitors/Artificial Pancreases
ALMURASHI, A. M., Rodriguez, E., & Garg, S. K. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00348-3 · Cited by 55
Self-citationPassanisi, S., Salzano, G., Bombaci, B., Minuto, N., Bassi, M., Bonfanti, R., Scialabba, F., Mozzillo, E., Candia, F. D., Monti, S. M., et al. (2024) · Diabetes Care · doi:10.2337/dc23-2311 · Cited by 41
Bionic Pancreas Research Group, Beck, R. W., Russell, S. J., Damiano, E. R., El-Khatib, F. H., Ruedy, K. J., Balliro, C., Li, Z., & Calhoun, P. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0167 · Cited by 40
Lombardo, F., Passanisi, S., Alibrandi, A., Bombaci, B., Bonfanti, R., Delvecchio, M., Candia, F. D., Mozzillo, E., Piccinno, E., Piona, C. A., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0491 · Cited by 41
Islam, M. T., Hasan, M. W., Hassan, M. F., & Çeşmeci, Ş. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16070944 · Cited by 39
Bionic Pancreas Research Group, Kruger, D., Kass, A., Lonier, J., Pettus, J., Raskin, P., Salam, M., Trikudanathan, S., Zhou, K., Russell, S. J., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0200 · Cited by 38
A meta-learning approach to personalized blood glucose prediction in type 1 diabetes
Langarica, S., Rodriguez-Fernández, M., Núñez, F., & Doyle, F. J. (2023) · Control Engineering Practice · doi:10.1016/j.conengprac.2023.105498 · Cited by 37
A Peek Under the Hood: Explaining the MiniMed™ 780G Algorithm with Meal Detection Technology
Grosman, B., Roy, A., LINTEREUR, L. J., Turksoy, K., Benedetti, A., Cordero, T. L., Vigersky, R. A., MCVEAN, J. J. F., Rhinehart, A. S., & Cohen, O. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0446 · Cited by 36
Self-citationArunachalum, S., Velado, K., Vigersky, R. A., & Cordero, T. L. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221088608 · Cited by 35
Self-citationSeget, S., Jarosz-Chobot, P. A., Ochab, A., Polańska, J., Rusak, E., Witoszek, P., & Chobot, A. P. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.1036808 · Cited by 35
Insight into continuous glucose monitoring: from medical basics to commercialized devices
Chmayssem, A., Nadolska, M., Tubbs, E., Sadowska, K., Vadgma, P., Shitanda, I., Tsujimura, S., Lattach, Y., Peacock, M., Tingry, S., et al. (2023) · Microchimica Acta · doi:10.1007/s00604-023-05743-w · Cited by 37
Passanisi, S., Lombardo, F., Mameli, C., Bombaci, B., Macedoni, M., Zuccotti, G., Dovč, K., Battelino, T., Salzano, G., & Delvecchio, M. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01501-6 · Cited by 37
PAULEY, M. E., Tommerdahl, K. L., Snell‐Bergeon, J. K., & Forlenza, G. P. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01799-x · Cited by 39
Key indices of glycaemic variability for application in diabetes clinical practice
Monnier, L., Bonnet, F., Colette, C., Renard, É., & Owens, D. R. (2023) · Diabetes & Metabolism · doi:10.1016/j.diabet.2023.101488 · Cited by 35
Vigersky, R. A., & Shin, J. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0435 · Cited by 33
Self-citationŠantová, A., Plachý, L., Neuman, V., Pavlı́ková, M., Petruželková, L., Konečná, P., Venháčová, P., Škvor, J., Pomahačová, R., Neumann, D., et al. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1283181 · Cited by 32
Lynch, J. L., Kanapka, L. G., Russell, S. J., Damiano, E. R., El-Khatib, F. H., Ruedy, K. J., BALLIRO, C. A., Calhoun, P. M., & Beck, R. W. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0341 · Cited by 31
Cordero, T. L., Dai, Z., Arrieta, A., Niu, F., Vella, M., Shin, J., Rhinehart, A. S., MCVEAN, J. J. F., Lee, S. W., Slover, R. H., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0123 · Cited by 33
Self-citationAl‐Sofiani, M. E., Petrovski, G., Shaikh, A. A., Alguwaihes, A. M., Harbi, M. A., Mohannadi, D. A., Adjene, A., Al-Agha, A. E., Remeithi, S. S. A., Alamuddin, N., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15389 · Cited by 30
Wang, X., Si, J., Li, Y., Tse, P., Zhang, G., Wang, X., Ren, J., Xu, J., Sun, J., & Yao, X. (2025) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-025-01819-0 · Cited by 30
Elbarbary, N. S., & Ismail, E. A. R. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.110045 · Cited by 31
Asgharzadeh, A., Patel, M., Connock, M. J., Damery, S. L., Ghosh, I., Jordan, M., Freeman, K., Brown, A., Court, R. A., Baldwin, S., et al. (2024) · Health Technology Assessment · doi:10.3310/jypl3536 · Cited by 32
Bassi, M., Franzone, D., Dufour, F., Strati, M. F., Scalas, M., Tantari, G., Aloi, C., Salina, A., d’Annunzio, G., Maghnie, M., et al. (2023) · Life · doi:10.3390/life13030783 · Cited by 34
Thrasher, J. R., Arrieta, A., Niu, F., Cameron, K. R., Cordero, T. L., Shin, J., Rhinehart, A. S., & Vigersky, R. A. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0453 · Cited by 29
Self-citationPast, Present, and Future of Continuous Glucose Monitors
Garg, S. K. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0041 · Cited by 28
Self-citationMichaels, V. R., Boucsein, A., Watson, A. S., Frewen, C. M., Sanders, O. J., Haszard, J. J., Jones, S., Milford-Hughes, P. J., de Bock, M. I., & Wheeler, B. J. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0334 · Cited by 28
Long-term outcomes of an advanced hybrid closed-loop system: A focus on different subpopulations
Beato-Víbora, P. I., Ambrojo-López, A., Fernández-Bueso, M., Gil-Poch, E., & Arroyo-Díez, F. J. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.110052 · Cited by 27
Pihoker, C., Shulman, D. I., Forlenza, G. P., Kaiserman, K. B., Sherr, J. L., Thrasher, J. R., Buckingham, B. A., Kipnes, M. S., Bode, B. W., Carlson, A. L., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0255 · Cited by 27
Self-citationGlobal Inequities in Diabetes Technology and Insulin Access and Glycemic Outcomes
Šantová, A., de Bock, M. I., Lanzinger, S., Goldbloom, E. B., Bratina, N., Barcala, C., Alhomaidah, D. S., Pande, A. K., Guness, P. K., Dzīvīte-Krišāne, I., et al. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.28933 · Cited by 27
Use of diabetes technology in children
Schoelwer, M. J., DeBoer, M. D., & Breton, M. D. (2024) · Diabetologia · doi:10.1007/s00125-024-06218-0 · Cited by 27
Benchmarking Diabetes Technology Use Among 21 U.S. Pediatric Diabetes Centers
Prahalad, P., Hardison, H., Odugbesan, O., Lyons, S. K., Alwazeer, M., Neyman, A., Miyazaki, B., Cossen, K., Hsieh, S., Eng, D. S., et al. (2023) · Clinical Diabetes · doi:10.2337/cd23-0052 · Cited by 23
Eviz, E., Kıllı, N. E., Karakus, K. E., Can, E., Gökçe, T., Mutlu, G. Y., & Hatun, Ş. (2024) · Diabetic Medicine · doi:10.1111/dme.15333 · Cited by 24
Halperin, I. J., Wicklow, B., Amed, S., Chambers, A., Courage, C., Cummings, E., Kirkland, P., MacKay, D., Nakhla, M., Punthakee, Z., et al. (2025) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2025.01.001 · Cited by 22
Nallicheri, A., Close Concerns, S. F., Mahoney, K. M., Close Concerns, S. F., Gutow, H. A., Close Concerns, S. F., Bellini, N. J., & Isaacs, D. M. (2022) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2022.18.1.27 · Cited by 24
Seget, S., Rusak, E., Polańska, J., & Jarosz-Chobot, P. A. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0148 · Cited by 22
Piccini, B., Pessina, B., Casalini, E., Lenzi, L., & Toni, S. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13440 · Cited by 22
Expanding the horizon of continuous glucose monitoring into the future of pediatric medicine
Morales-Dopico, L., & MacLeish, S. A. (2024) · Pediatric Research · doi:10.1038/s41390-024-03573-x · Cited by 23
CYRANKA, K. M., Matejko, B., Juza, A., Kieć‐Wilk, B., Krzyżowska, S., Cohen, O., Silva, J. D., Lushchyk, M. L., Malecki, M. T., & Klupa, T. (2022) · JMIR Formative Research · doi:10.2196/43535 · Cited by 24
Development and Future of Automated Insulin Delivery (AID) Systems
Garg, S. K., & MCVEAN, J. J. F. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0467 · Cited by 25
Self-citationYu, X., Yang, Z., Sun, X., Liu, H., Li, H., Lu, J., Zhou, J. H., & Çınar, A. (2025) · AI · doi:10.3390/ai6050087 · Cited by 23
Elbarbary, N. S., & Ismail, E. A. R. (2023) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-023-01184-w · Cited by 20
Reducing Diabetes Burden in Medtronic's Automated Insulin Delivery Systems
Forlenza, G. P., Dai, Z., Niu, F., & Shin, J. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0459 · Cited by 20
Self-citationLaugesen, C., Ritschel, T., Ranjan, A. G., Hsu, L. J., Jørgensen, J. B., Svensson, J., Ekhlaspour, L., Buckingham, B. A., & Nørgaard, K. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0022 · Cited by 22
Nattero‐Chávez, L., Pascual, E. L., de la Villa, E. D. L. C., Cebada, A. B., Ruiz, T., Tobar, A. Q., Lorenzo, M., Sánchez, C., Izquierdo, A., Luque‐Ramírez, M., et al. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110627 · Cited by 19
Castañeda, J., Arrieta, A., van den Heuvel, T. R. A., & Cohen, O. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15139 · Cited by 18
Shannon, N., Castañeda, J., Choudhary, P., Kolassa, R., Keuthage, W., Kroeger, J., Thivolet, C. H., Evans, M. L., Ré, R., Cellot, J., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15217 · Cited by 18
Self-citationEvidence from clinical trials on high-risk medical devices in children: a scoping review
Guerlich, K., Patro-Gołąb, B., Dworakowski, P., Fraser, A. G., Kammermeier, M., Melvin, T., & Koletzko, B. V. (2023) · Pediatric Research · doi:10.1038/s41390-023-02819-4 · Cited by 17
Lablanche, S., Delagenière, J., Jalbert, M., Sonnet, E., Bénichou, M., Arnold, N., Spiteri, A., Berre, J. P. L., Renard, É., Chevalier, N., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0414 · Cited by 18
Self-citationWhen Sugar Reaches the Liver: Phenotypes of Patients with Diabetes and NAFLD
Rojano‐Toimil, A., Rivera‐Esteban, J., Manzano-Núñez, R., Bañares, J., Selva, D. M., Gabriel-Medina, P., Ferrer, R., Pericàs, J. M., & Ciudin, A. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11123286 · Cited by 20
Closed-Loop Artificial Pancreas Therapy for Type 1 Diabetes
Zhou, K., & Isaacs, D. M. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01733-1 · Cited by 18
Rachmiel, M., Lebenthal, Y., Mazor‐Aronovitch, K., Brener, A., Levek, N., Jacobi‐Polishook, T., Ari, T. B., Abiri, S., Landau, Z., & Pinhas‐Hamiel, O. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0081 · Cited by 17
Mozzillo, E., Marigliano, M., Cuccurullo, I., Berchielli, F., Auricchio, R., Maffeis, C., Rosanio, F. M., Iafusco, D., Pedrolli, C., Pertile, R., et al. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.111074 · Cited by 19
Galindo, R. J., Aleppo, G., Parkin, C. G., Baidal, D. A., Carlson, A. L., Cengiz, E., Forlenza, G. P., Kruger, D. F., Levy, C. J., McGill, J. B., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221144052 · Cited by 18
Self-citationGardner, D. S.-L., Lakkad, M., Qiu, Z., Inoue, Y., CHANDRAN, S. R., & Wherry, K. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0455 · Cited by 16
Mittal, R., Koutras, N., Maya, J., Lemos, J. R. N., & Hirani, K. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1352302 · Cited by 18
Kesavadev, J., Basanth, A., Krishnan, G., Shankar, A., Sanal, G., & Jothydev, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01427-z · Cited by 16
Medina, A. M. G., Henao, D. C., Yepes, C. A., Silva, J., González, J. A. G., Cortés, D., Robledo, S., Mejía, G., & Rondón, M. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110897 · Cited by 14
Karakus, K. E., Shah, V. N., Klonoff, D. C., & Aktürk, H. K. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15208 · Cited by 14
Wannes, S., Gamal, G. M., Fredj, M. B., Qusayer, D. A., Abed, S. E., Sedky, Y., & Khalil, M. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110867 · Cited by 14
Petrovski, G., Khalaf, F. A., Campbell, J., Day, E., Almajaly, D., Hussain, K., Pasha, M., Umer, F., Hamdan, M., & Khalifa, A. (2022) · Acta Diabetologica · doi:10.1007/s00592-022-01851-w · Cited by 14
Herguido, N. G., Amuedo, S., Bellido, V., Gallardo, G. L., Losada, F., Pérez-Morales, A., Trillo, C. A. R., & Moreno, A. S. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0287 · Cited by 13
Seget, S., Włodarczyk, J., Lutogniewska, W., Rusak, E., Dróżdż, M., & Jarosz-Chobot, P. A. (2023) · Healthcare · doi:10.3390/healthcare11040587 · Cited by 13
(Hybrid) Closed-Loop Systems: From Announced to Unannounced Exercise
Zimmer, R. T., Auth, A., Schierbauer, J., Haupt, S., Wachsmuth, N. B., Zimmermann, P., Voit, T., Battelino, T., Sourij, H., & Moser, O. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0293 · Cited by 15
Lingen, K., Maahs, D. M., Bellini, N. J., & Isaacs, D. M. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0440 · Cited by 13
Singh, R., Imberg, H., Ahmadi, S. S., Hallström, S., JENDLE, J. H., Tengmark, B.-O., Folino, A., Marie, E., & Lind, M. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241242386 · Cited by 13
Elbarbary, N. S., Alguwaihes, A. M., ZARIF, H. A., Hassanein, M., Deeb, A., Petrovski, G., Aldahash, R., Amoudi, R. A., Hussain, S., Ibrahim, M. A., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0200 · Cited by 13
Managing obesity in adults with type 1 diabetes
Campos, A., Gutiérrez, R. D. J. R., Galindo, R. J., McCoy, R. G., & Andrade, M. D. H. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111983 · Cited by 12
Metadata
- Authors
- Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., Thrasher, J. R., Reed, J. H. C., Slover, R. H., Philis-Tsimikas, A., Christiansen, M., Grosman, B., Roy, A., Vella, M., Jonkers, R. A. M., Chen, X., Shin, J., Cordero, T. L., Lee, S. W., Rhinehart, A. S., Vigersky, R. A., & for the MiniMed™ AHCL Study Group
- Affiliations
- HealthPartners (US)
- Yale University (US)
- University of South Florida (US)
- Barbara Davis Center of Childhood Diabetes, Aurora, Colorado, USA.
- Division of Metabolism, Endocrinology and Diabetes, University of Michigan, Ann Arbor, Michigan, USA.
- Atlanta Diabetes Associates (US)
- Rocky Mountain Diabetes and Osteoporosis Center, Idaho Falls, Idaho, USA.
- Rainier Clinical Research Center, Renton, Washington, USA.
- SoCal Diabetes, Torrance, California, USA.
- Diabetes & Glandular Disease Clinic (US)
- Arkansas Diabetes and Endocrinology Center, Little Rock, Arkansas, USA.
- Endocrine Research Solutions (United States) (US)
- Scripps Whittier Diabetes Institute, La Jolla, California, USA.
- Diablo Clinical Research (US)
- Medtronic (United States) (US)
- Corresponding author
- Carlson, Anders L.
- ORCID
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2022-03
- Volume
- 24
- Issue
- 3
- Pages
- 178-189
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- PMC
- PMC8971997
- OpenAlex
- W3210094726
- Cited by
- 230
- References
- 43
- Citations by year
- 2026: 35 · 2025: 45 · 2024: 55 · 2023: 61 · 2022: 34
- FWCI
- 28.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes Technology & Therapeutics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK020572, P30DK045735, P30DK111022)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, hybrid closed-loop system, glycemic control, HbA1c, time in range, time below range, sensor-augmented pump, adolescents, adults, clinical trial safety, glycemic outcomes
- MeSH terms
- Adolescent, Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Middle Aged, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review