CoChat

In Vitro Perfusion of Engineered Heart Tissue Through Endothelialized Channels

Vollert, Ingra, Seiffert, Moritz, Bachmair, Johanna, Sander, Merle, Eder, Alexandra, Conradi, Lenard, Vogelsang, Alexander, Schulze, Thomas, Uebeler, June, Holnthoner, Wolfgang, Redl, Heinz, Reichenspurner, Hermann, Hansen, Arne, Eschenhagen, Thomas · 2014 · Tissue Engineering Part A
Cited by 94

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

In engineered heart tissues (EHT), oxygen and nutrient supply via mere diffusion is a likely factor limiting the thickness of cardiac muscle strands. Here, we report on a novel method to in vitro perfuse EHT through tubular channels. Adapting our previously published protocols, we expanded a miniaturized fibrin-based EHT-format to a larger six-well format with six flexible silicone posts holding each EHT (15×25×3 mm 3 ). Thin dry alginate fibers (17×0.04×0.04 mm) were embedded into the cell–fibrin–thrombin mix and, after fibrin polymerization, dissolved by incubation in alginate lyase or sodium citrate. Oxygen concentrations were measured with a microsensor in 14-day-old EHTs (37°C, 21% oxygen) and ranged between 9% at the edges and 2% in the center of the tissue. Perfusion rapidly increased it to 10%–12% in the immediate vicinity of the microchannel. Continuous perfusion (20 μL/h, for 3 weeks) of the tubular lumina (100–500 μm) via hollow posts of the silicone rack increased mean dystrophin-positive cardiomyocyte density (36%±6% vs. 10%±3% of total cell number) and cross sectional area (73±2 vs. 48±1 μm 2 ) in the central part of the tissue compared to nonperfused EHTs. The channels were populated by endothelial cells present in the reconstitution cell mix. In conclusion, we developed a novel approach to generate small tubular structures suitable for perfusion of spontaneously contracting and force-generating EHTs and showed that prolonged perfusion improved cardiac tissue structure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2013.0214

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 94

Metadata

Authors
Vollert, I., Seiffert, M., Bachmair, J., Sander, M., Eder, A., Conradi, L., Vogelsang, A., Schulze, T., Uebeler, J., Holnthoner, W., Redl, H., Reichenspurner, H., Hansen, A., & Eschenhagen, T.
Venue
Tissue Engineering Part A
Published
2013-12-09
Volume
20
Issue
3-4
Pages
854-863
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2098220131
Cited by
94
References
10
FWCI
8.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.