In Vitro Perfusion of Engineered Heart Tissue Through Endothelialized Channels
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
In engineered heart tissues (EHT), oxygen and nutrient supply via mere diffusion is a likely factor limiting the thickness of cardiac muscle strands. Here, we report on a novel method to in vitro perfuse EHT through tubular channels. Adapting our previously published protocols, we expanded a miniaturized fibrin-based EHT-format to a larger six-well format with six flexible silicone posts holding each EHT (15×25×3 mm 3 ). Thin dry alginate fibers (17×0.04×0.04 mm) were embedded into the cell–fibrin–thrombin mix and, after fibrin polymerization, dissolved by incubation in alginate lyase or sodium citrate. Oxygen concentrations were measured with a microsensor in 14-day-old EHTs (37°C, 21% oxygen) and ranged between 9% at the edges and 2% in the center of the tissue. Perfusion rapidly increased it to 10%–12% in the immediate vicinity of the microchannel. Continuous perfusion (20 μL/h, for 3 weeks) of the tubular lumina (100–500 μm) via hollow posts of the silicone rack increased mean dystrophin-positive cardiomyocyte density (36%±6% vs. 10%±3% of total cell number) and cross sectional area (73±2 vs. 48±1 μm 2 ) in the central part of the tissue compared to nonperfused EHTs. The channels were populated by endothelial cells present in the reconstitution cell mix. In conclusion, we developed a novel approach to generate small tubular structures suitable for perfusion of spontaneously contracting and force-generating EHTs and showed that prolonged perfusion improved cardiac tissue structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Perfusion-decellularized matrix: using nature's platform to engineer a bioartificial heart
Ott, H. C., Matthiesen, T. S., Goh, S.-K., Black, L. D., Kren, S. M., Netoff, T. I., & Taylor, D. A. (2008) · Nature Medicine · doi:10.1038/nm1684 · Cited by 2,650
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Growth of engineered human myocardium with mechanical loading and vascular coculture
Tulloch, N. L., Muskheli, V., Razumova, M. V., Korte, F. S., Regnier, M., Hauch, K. D., Pabon, L., Reinecke, H., & Murry, C. E. (2011) · Circulation Research · doi:10.1161/circresaha.110.237206 · Cited by 666
Eschenhagen, T., Fink, C., Remmers, U., Scholz, H., Wattchow, J., Weil, J., Zimmermann, W., Dohmen, H. H., Schäfer, H., Bishopric, N., et al. (1997) · The FASEB Journal · doi:10.1096/fasebj.11.8.9240969 · Cited by 636 · cited 1×
“We know from former studies with EHTs 37,38 that force lines are critical and integration of a tubular structure in the middle could well change them.”
Self-citationTissue engineering of vascularized cardiac muscle from human embryonic stem cells
Caspi, O., Lesman, A., Basevitch, Y., Gepstein, A., Arbel, G., Habib, I. H. M., Gepstein, L., & Levenberg, S. (2007) · Circulation Research · doi:10.1161/01.res.0000257776.05673.ff · Cited by 558
Development of a drug screening platform based on engineered heart tissue
Hansen, A., Eder, A., Bönstrup, M., Flato, M., Mewe, M., Schaaf, S., Aksehirlioglu, B., Schwörer, A., Uebeler, J., & Eschenhagen, T. (2010) · Circulation Research · doi:10.1161/circresaha.109.211458 · Cited by 510
Self-citationOxygen gradients correlate with cell density and cell viability in engineered cardiac tissue
Radisic, M., Malda, J., Epping, E., Geng, W., Langer, R., & Vunjak‐Novakovic, G. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20722 · Cited by 399
Transplantation of a Tissue-Engineered Human Vascularized Cardiac Muscle
Lesman, A., Habib, M., Caspi, O., Gepstein, A., Arbel, G., Levenberg, S., & Gepstein, L. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0130 · Cited by 241
Perfusable branching microvessel bed for vascularization of engineered tissues
Chiu, L. L. Y., Montgomery, M., Liang, Y., Liu, H., & Radisic, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210580109 · Cited by 171
Cited by
Zhang, B., Montgomery, M., Chamberlain, M. D., Ogawa, S., Korolj, A., Pahnke, A., Wells, L. A., Massé, S., Kim, J., Reis, L., et al. (2016) · Nature Materials · doi:10.1038/nmat4570 · Cited by 593
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Cardiac Tissue Engineering: State of the Art
Hirt, M. N., Hansen, A., & Eschenhagen, T. (2014) · Circulation Research · doi:10.1161/circresaha.114.300522 · Cited by 425
Self-citationDenning, C., Borgdorff, V., Crutchley, J., Firth, K. S. A., George, V., Kalra, S., Kondrashov, A., Hoang, M. D., Mosqueira, D., Patel, A., et al. (2016) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2015.10.014 · Cited by 293
“Integration of pre-formed vascular structures [141] or of additional extracellular matrix (e.”
BackgroundEngineering Cardiac Muscle Tissue: A Maturating Field of Research
Weinberger, F., Mannhardt, I., & Eschenhagen, T. (2017) · Circulation Research · doi:10.1161/circresaha.117.310738 · Cited by 225
Self-citationDynamic culture yields engineered myocardium with near-adult functional output
Jackman, C. P., Carlson, A. L., & Bursac, N. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.024 · Cited by 188
“Local depletion of oxygen has been observed in th e vicinity of cultured CMs [13-15], highlighting the need to enhance nutrient and oxygen transport in 3D engineered cardiac tissues.”
Vascularized microfluidic organ-chips for drug screening, disease models and tissue engineering
Osaki, T., Sivathanu, V., & Kamm, R. D. (2018) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.03.011 · Cited by 141
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Metadata
- Authors
- Vollert, I., Seiffert, M., Bachmair, J., Sander, M., Eder, A., Conradi, L., Vogelsang, A., Schulze, T., Uebeler, J., Holnthoner, W., Redl, H., Reichenspurner, H., Hansen, A., & Eschenhagen, T.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2013-12-09
- Volume
- 20
- Issue
- 3-4
- Pages
- 854-863
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2098220131
- Cited by
- 94
- References
- 10
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.