The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Abstract
Frequent determination of glucose concentrations in diabetic patients is an important tool for diabetes management. This requires repetitive lancing and finger bleeding. Use of noninvasive (NI) detection techniques offers several advantages, such as the absence of pain and exposure to sharp objects and biohazard materials, the potential for increased frequency of testing, and hence, tighter control of the glucose concentrations, and the potential for a closed-loop system including a monitor and an insulin pump. These potential advantages have led to considerable interest in the commercialization of NI glucose monitoring devices. Review of the scientific, patent, and commercial literature indicates that the spectroscopic basis for NI determination of glucose is not yet well established, and attempts at commercialization may be several steps ahead of our understanding the origin and characteristics of an in vivo glucose-specific or glucose-related signal. Several technologies have potential for leading to viable measuring devices, but most of the data are based on in vitro experimentation. Because of the technical complexity of in vivo glucose measurements, this review aims at discussing the gap between the established need and current technology limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 371
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 312
Chiral Plasmonic Films Formed by Gold Nanorods and Cellulose Nanocrystals
Querejeta-Fernández, A., Chauve, G., Methot, M., Bouchard, J., & Kumacheva, E. (2014) · Journal of the American Chemical Society · doi:10.1021/ja501642p · Cited by 311
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
“However, some sources of errors are due to eye movements and corneal rotations [34].”
BackgroundRaman spectroscopy for noninvasive glucose measurements
Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W.-C., Sasic, S., Horowitz, G. L., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920212 · Cited by 271
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Self-citationOverview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
Generic Raman‐based calibration models enabling real‐time monitoring of cell culture bioreactors
Mehdizadeh, H., Lauri, D., Karry, K. M., Moshgbar, M., Procopio‐Melino, R., & Drapeau, D. (2015) · Biotechnology Progress · doi:10.1002/btpr.2079 · Cited by 108
Newer portable glucose meters—analytical improvement compared with previous generation devices?
Weitgasser, R., Gappmayer, B., & Pichler, M. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.10.1821 · Cited by 85
Huang, W., Besar, K., LeCover, R., Dulloor, P., Sinha, J., Martínez Hardigree, J. F., Pick, C., Swavola, J., Everett, A. D., Frechette, J., et al. (2014) · Chem. Sci. · doi:10.1039/c3sc52638k · Cited by 83
Noninvasive Photonic-Crystal Material for Sensing Glucose in Tears
Khalil, O. S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.042978 · Cited by 30
“Most noninvasive (NI) methods for the determination of glucose either detect a small specific glucose signal or measure the effect of glucose on a tissue optical property (1, 2).”
MethodSelf-citationSacks, D. B. (2012) · Tietz Textbook of Clinical Chemistry and Molecular Diagnostics · doi:10.1016/b978-1-4160-6164-9.00046-9 · Cited by 7
Metadata
- Authors
- Khalil, O. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-02-01
- Volume
- 45
- Issue
- 2
- Pages
- 165-177
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1938981039
- Cited by
- 331
- References
- 74
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.