The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Abstract
Frequent determination of glucose concentrations in diabetic patients is an important tool for diabetes management. This requires repetitive lancing and finger bleeding. Use of noninvasive (NI) detection techniques offers several advantages, such as the absence of pain and exposure to sharp objects and biohazard materials, the potential for increased frequency of testing, and hence, tighter control of the glucose concentrations, and the potential for a closed-loop system including a monitor and an insulin pump. These potential advantages have led to considerable interest in the commercialization of NI glucose monitoring devices. Review of the scientific, patent, and commercial literature indicates that the spectroscopic basis for NI determination of glucose is not yet well established, and attempts at commercialization may be several steps ahead of our understanding the origin and characteristics of an in vivo glucose-specific or glucose-related signal. Several technologies have potential for leading to viable measuring devices, but most of the data are based on in vitro experimentation. Because of the technical complexity of in vivo glucose measurements, this review aims at discussing the gap between the established need and current technology limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Optical reflectance and transmittance of tissues: principles and applications
Wilson, B. C., & Jacques, S. L. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64355 · Cited by 421
Grasselli, J. G., & Bulkin, B. J. (1991) · Cited by 373
(1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540170053032 · Cited by 349
Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry
Fantini, S. (1995) · Optical Engineering · doi:10.1117/12.183988 · Cited by 330
Diffusion of light in turbid material
Ishimaru, A. (1989) · Applied Optics · doi:10.1364/ao.28.002210 · Cited by 325
Pulse Oximetry: Theory and Applications for Noninvasive Monitoring
Mendelson, Y. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1601 · Cited by 320
Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Mie and Rayleigh modeling of visible-light scattering in neonatal skin
Saidi, I. S., Jacques, S. L., & Tittel, F. K. (1995) · Applied Optics · doi:10.1364/ao.34.007410 · Cited by 294
Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation
Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1618 · Cited by 284
Consensus Statement on Self-Monitor ing of Blood Glucose
(1987) · Diabetes Care · doi:10.2337/diacare.10.1.95 · Cited by 248
Graaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Patterson, M. S., Moulton, J. D., Wilson, B. C., Berndt, K. W., & Lakowicz, J. R. (1991) · Applied Optics · doi:10.1364/ao.30.004474 · Cited by 238
Noninvasive Blood Glucose Monitoring
Klonoff, D. C. (1997) · Diabetes Care · doi:10.2337/diacare.20.3.433 · Cited by 208
Near Infrared Spectra Of Organic Compounds
Wheeler, O. H. (1959) · Chemical Reviews · doi:10.1021/cr50028a004 · Cited by 188
Rabinovitch, B., March, W. F., & Adams, R. L. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.254 · Cited by 179
Infrared and raman spectroscopy of carbohydrates
Vasko, P. D., Blackwell, J., & Koenig, J. L. (1971) · Carbohydrate Research · doi:10.1016/s0008-6215(00)86160-1 · Cited by 178
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42107 · Cited by 177
Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy
Edwards, A. D., Richardson, C. E., van der Zee, P., Elwell, C. E., Wyatt, J. S., Cope, M., Delpy, D. T., & Reynolds, E. O. R. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.4.1884 · Cited by 173
Accuracy of Perceiving Blood Glucose in IDDM
Cox, D. J., Clarke, W. L., Gonder-Frederick, L., Pohl, S., Hoover, C., Snyder, A., Zimbelman, L., Carter, W. R., Bobbitt, S., & Pennebaker, J. (1985) · Diabetes Care · doi:10.2337/diacare.8.6.529 · Cited by 169
Heise, H. M., Marbach, R., Janatsch, G., & Kruse-Jarres, J. D. (1989) · Analytical Chemistry · doi:10.1021/ac00193a004 · Cited by 165
Marbach, R., Koschinsky, T., Gries, F. A., & Heise, H. M. (1993) · Applied Spectroscopy · doi:10.1366/0003702934415354 · Cited by 164
Influence of glucose concentration on light scattering in tissue-simulating phantoms
Kohl, M., Essenpreis, M., Böcker, D., & Cope, M. (1994) · Optics Letters · doi:10.1364/ol.19.002170 · Cited by 158
Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
Cote, G. L., Fox, M. D., & Northrop, R. B. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142650 · Cited by 158
Noninvasive Blood Glucose Sensors Based on Near‐Infrared Spectroscopy
Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A. (1994) · Artificial Organs · doi:10.1111/j.1525-1594.1994.tb02230.x · Cited by 156
Bruulsema, J. T., Hayward, J. E., Farrell, T. J., Patterson, M. S., Heinemann, L., Berger, M., Koschinsky, T., Sandahl-Christiansen, J., Ørskov, H., Essenpreis, M., et al. (1997) · Optics Letters · doi:10.1364/ol.22.000190 · Cited by 156
The influence of glucose concentration upon the transport of light in tissue-simulating phantoms
Kohl, M., Essenpreis, M., & Cope, M. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/7/009 · Cited by 140
Groenhuis, R. A. J., ten Bosch, J. J., & Ferwerda, H. A. (1983) · Applied Optics · doi:10.1364/ao.22.002463 · Cited by 138
Farrell, T. J., Wilson, B. C., & Patterson, M. S. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/12/009 · Cited by 130
Reverse Iontophoresis: Development of a Noninvasive Approach for Glucose Monitoring
Rao, G., Glikfeld, P., & Guy, R. H. (1993) · Pharmaceutical Research · doi:10.1023/a:1018926215306 · Cited by 126
Temperature-Insensitive Near-Infrared Spectroscopic Measurement of Glucose in Aqueous Solutions
Hazen, K. H., Arnold, M. A., & Small, G. W. (1994) · Applied Spectroscopy · doi:10.1366/000370294775268910 · Cited by 119
Phantom Glucose Calibration Models from Simulated Noninvasive Human Near-Infrared Spectra
Arnold, M. A., Burmeister, J. J., & Small, G. W. (1998) · Analytical Chemistry · doi:10.1021/ac9710801 · Cited by 116
Small, G. W., Arnold, M. A., & Marquardt, L. A. (1993) · Analytical Chemistry · doi:10.1021/ac00070a019 · Cited by 106
Heise, H. M., Marbach, R., Koschinsky, T., & Gries, F. A. (1994) · Applied Spectroscopy · doi:10.1366/0003702944027598 · Cited by 105
Progress Toward the Development of an Implantable Sensor for Glucose
Wilson, G. S., Zhang, Y., Reach, G., Moatti-Sirat, D., Poitout, V., Thévenot, D. R., Lemonnier, F., & Klein, J. C. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1613 · Cited by 105
March, W. F., Rabinovitch, B., & Adams, R. L. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.259 · Cited by 102
Application of a multivariate technique to Raman spectra for quantification of body chemicals
Goetz, M. J., Coté, G. L., Erckens, R. J., March, W. F., & Motamedi, M. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.391172 · Cited by 102
Laser photoacoustic determination of physiological glucose concentrations in human whole blood
Christison, G. B., & MacKenzie, H. A. (1993) · Medical & Biological Engineering & Computing · doi:10.1007/bf02458048 · Cited by 99
Reagentless Near-Infrared Determination of Glucose in Whole Blood Using Multivariate Calibration
Haaland, D. M., Robinson, M., Koepp, G. W., Thomas, E. V., & Eaton, R. P. (1992) · Applied Spectroscopy · doi:10.1366/000370292789619232 · Cited by 99
Non-invasive glucose monitoring
Arnold, M. A. (1996) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(96)80093-0 · Cited by 91
Pan, S., Chung, H., Arnold, M. A., et al. (1996) · Analytical Chemistry · doi:10.1021/ac950751x · Cited by 90
Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
Heinemann, L., & Schmelzeisen‐Redeker, G. (1998) · Diabetologia · doi:10.1007/s001250050998 · Cited by 85
Multispectral polarimetric glucose detection using a single Pockels cell
King, T. W., Coté, G. L., McNichols, R. J., & Goetz, M. J. (1994) · Optical Engineering · doi:10.1117/12.173556 · Cited by 83
Berger, A. J., Wang, Y., & Feld, M. S. (1996) · Applied Optics · doi:10.1364/ao.35.000209 · Cited by 83
Near-infrared spectroscopic measurement of glucose in a protein matrix
Marquardt, L. A., Arnold, M. A., & Small, G. W. (1993) · Analytical Chemistry · doi:10.1021/ac00070a018 · Cited by 81
Non-Invasive Monitoring of Metabolites Using Near Infrared Spectroscopy: State of the Art
Heise, H. M. (1996) · Hormone and Metabolic Research · doi:10.1055/s-2007-979846 · Cited by 73
An Overview of Minimally Invasive Technologies
Ginsberg, B. H. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1596 · Cited by 72
Analysis of metabolites in aqueous solutions by using laser Raman spectroscopy
Wang, S. Y., Hasty, C. E., Watson, P. A., Wicksted, J. P., Stith, R. D., & March, W. F. (1993) · Applied Optics · doi:10.1364/ao.32.000925 · Cited by 71
Diffusion Theory of Light Transport
Star, W. M. (2010) · Springer eBooks · doi:10.1007/978-90-481-8831-4_6 · Cited by 69
Müller, U., Mertes, B., Fischbacher, C., Jagemann, K.-U., & Danzer, K. (1997) · The International Journal of Artificial Organs · doi:10.1177/039139889702000509 · Cited by 65
Multivariate Calibration Methods Applied to Quantitative FT-IR Analyses
Haaland, D. M. (1990) · Elsevier eBooks · doi:10.1016/b978-0-12-254125-4.50013-6 · Cited by 58
Measurement of Tissue Optical Properties: Methods and Theories
Wilson, B. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7_8 · Cited by 57
Jagemann, K.-U., Fischbacher, C., Danzer, K., Müller, U., & Mertes, B. (1995) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1995.191.part_2.179 · Cited by 55
Quantitative and Qualitative Analysis of Some Inorganic Compounds by Raman Spectroscopy
Lombardi, D. R., Wang, C., Sun, B., Fountain, A. W., III, Vickers, T. J., Mann, C. K., Reich, F. R., Douglas, J. G., Crawford, B. A., & Kohlasch, F. L. (1994) · Applied Spectroscopy · doi:10.1366/0003702944029802 · Cited by 51
Wicksted, J. P., Erckens, R. J., Motamedi, M., & March, W. F. (1995) · Applied Spectroscopy · doi:10.1366/0003702953964912 · Cited by 46
Qu, J. Y., & Wilson, B. C. (1997) · Journal of Biomedical Optics · doi:10.1117/12.275453 · Cited by 46
Simultaneous measurement of glucose and glutamine in aqueous solutions by near infrared spectroscopy
Chung, H., Arnold, M. A., Rhiel, M. H., et al. (1995) · Applied Biochemistry and Biotechnology · doi:10.1007/bf02783448 · Cited by 45
Tanaka, K., Pacheco, M. T. T., Brennan, J. F., Itzkan, I., Berger, A. J., Dasari, R. R., & Feld, M. S. (1996) · Applied Optics · doi:10.1364/ao.35.000758 · Cited by 43
Dou, X., Yamaguchi, Y., Yamamoto, H., Uenoyama, H., & Ozaki, Y. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905042 · Cited by 43
Spanner, G., & Nießner, R. (1996) · Analytical and Bioanalytical Chemistry · doi:10.1007/s0021663550327 · Cited by 38
Noninvasive polarimetric measurement of glucose in cell culture media
Coté, G. L., & Cameron, B. D. (1997) · Journal of Biomedical Optics · doi:10.1117/12.275221 · Cited by 33
Sodickson, L., & Block, M. J. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.9.1838 · Cited by 28
Raman measurement of glucose in bioreactor materials
Xu, Y., Ford, J. F., Mann, C. K., Vickers, T. J., Brackett, J. M., Cousineau, K. L., & Robey, W. G. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.275527 · Cited by 18
The Composition and Optical Rotary Dispersion of Bovine Aqueous Humor
Cough, D. A. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.266 · Cited by 17
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Metadata
- Authors
- Khalil, O. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-02-01
- Volume
- 45
- Issue
- 2
- Pages
- 165-177
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1938981039
- Cited by
- 331
- References
- 74
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.