Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
AIMS: Late stent malapposition (LSM) may be acquired (LASM) or persistent. LSM may play a role in patients who develop late stent thrombosis (ST). Our objective was to compare the risk of LASM in bare metal stents (BMS) with drug-eluting stents (DES) and to investigate the possible association of both acquired and persistent LSM with (very) late ST. METHODS AND RESULTS: We searched PubMed and relevant sources from January 2002 to December 2007. Inclusion criteria were: (a) intra-vascular ultrasonography (IVUS) at both post-stent implantation and follow-up; (b) 6-9-month-follow-up IVUS; (c) implantation of either BMS or the following DES: sirolimus, paclitaxel, everolimus, or zotarolimus; and (d) follow-up for LSM. Of 33 articles retrieved for detailed evaluation, 17 met the inclusion criteria. The risk of LASM in patients with DES was four times higher compared with BMS (OR = 4.36, CI 95% 1.74-10.94) in randomized clinical trials. The risk of (very) late ST in patients with LSM (five studies) was higher compared with those without LSM (OR = 6.51, CI 95% 1.34-34.91). CONCLUSION: In our meta-analysis, the risk of LASM is strongly increased after DES implantation compared with BMS. Furthermore, LSM seems to be associated with late and very late ST.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Verhagen, A. P., de Vet, H. C. W., de Bie, R. A., Kessels, A. G. H., Boers, M., Bouter, L. M., & Knipschild, P. G. (1998) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(98)00131-0 · Cited by 2,379
Mintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Advanced methods in meta‐analysis: multivariate approach and meta‐regression
van Houwelingen, H. C., Arends, L. R., & Stijnen, T. (2002) · Statistics in Medicine · doi:10.1002/sim.1040 · Cited by 1,580
Self-citationVirmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469
Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents
Mauri, L., Hsieh, W.-H., Massaro, J. M., Ho, K. K. L., D'Agostino, R., & Cutlip, D. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067731 · Cited by 1,441
Drug-Eluting Stent and Coronary Thrombosis: Biological Mechanisms and Clinical Implications
Lüscher, T. F., Steffel, J., Eberli, F. R., Joner, M., Nakazawa, G., Tanner, F. C., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.106.675934 · Cited by 906
Grube, E., Silber, S., Hauptmann, K. E., Mueller, R., Buellesfeld, L., Gerckens, U., & Russell, M. E. (2003) · Circulation · doi:10.1161/01.cir.0000047700.58683.a1 · Cited by 865
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S. (2007) · Circulation · doi:10.1161/circulationaha.106.658237 · Cited by 839
Chu, H., & Cole, S. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.06.011 · Cited by 708
SDZ RAD, A NEW RAPAMYCIN DERIVATIVE: Pharmacological Properties In Vitro and In Vivo
Schuler, W., Sedrani, R., Cottens, S., H??berlin, B., Schulz, M., Schuurman, H.-J., Zenke, G., Zerwes, H.-G., & Schreier, M. H. (1997) · Transplantation · doi:10.1097/00007890-199707150-00008 · Cited by 533
Fajadet, J., Wijns, W., Laarman, G.-J., Kuck, K.-H., Ormiston, J., Münzel, T., Popma, J. J., Fitzgerald, P. J., Bonan, R., & Kuntz, R. E. (2006) · Circulation · doi:10.1161/circulationaha.105.591206 · Cited by 464
A bivariate approach to meta-analysis
Van Houwelingen, H. C., Zwinderman, K. H., & Stijnen, T. (1993) · Statistics in Medicine · doi:10.1002/sim.4780122405 · Cited by 327 · cited 3×
“However, due to the small numbers of LASMs, the hypergeometric distribution as described by van Houwelingen et al.(19) was used to model the number of events within a study, instead of the usual normal approximation.”
MethodSelf-citationJournal of Invasive Cardiology
(2023) · The Journal of invasive cardiology/The journal of invasive cardiology · doi:10.25270/jic · Cited by 285
Drug-eluting stents: caution and concerns for long-term outcome
Virmani, R., Farb, A., Guagliumi, G., & Kolodgie, F. D. (2004) · Coronary Artery Disease · doi:10.1097/00019501-200409000-00003 · Cited by 231
Late Thrombosis After Radiation: Sitting on a Time Bomb
Waksman, R. (1999) · Circulation · doi:10.1161/01.cir.100.8.780 · Cited by 175
Combining multiple outcome measures in a meta‐analysis: an application
Arends, L. R., Vokó, Z., & Stijnen, T. (2003) · Statistics in Medicine · doi:10.1002/sim.1370 · Cited by 74
Self-citationTsuchiya, Y., Lansky, A. J., da Costa, R. A., Mehran, R., Pietras, C. G., Shimada, Y., Sonoda, S., Cristea, E., Negoita, M., Dangas, G., et al. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.02.054 · Cited by 71
Waugh, J., & Wagstaff, A. J. (2004) · American Journal of Cardiovascular Drugs · doi:10.2165/00129784-200404040-00006 · Cited by 51
Cited by
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Giustino, G., Colombo, A., Camaj, A., Yasumura, K., Mehran, R., Stone, G. W., Kini, A., & Sharma, S. K. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.05.017 · Cited by 413
Metadata
- Authors
- Hassan, A. K. M., Bergheanu, S. C., Stijnen, T., van der Hoeven, B. L., Snoep, J. D., Plevier, J. W. M., Schalij, M. J., & Wouter Jukema, J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-01-21
- Volume
- 31
- Issue
- 10
- Pages
- 1172-1180
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2138435070
- Cited by
- 290
- References
- 23
- FWCI
- 32.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.