Imaging, Distribution, and Toxicity of Superparamagnetic Iron Oxide Magnetic Resonance Nanoparticles in the Rat Brain and Intracerebral Tumor
The DOI matches its OpenAlex record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Superparamagnetic iron oxide nanoparticle magnetic resonance imaging (MRI) contrast agents are gaining use in the central nervous system. The purpose of this study was to evaluate the imaging characteristics, distribution, time course, and neurotoxicity of the clinical agents ferumoxtran-10, ferumoxides, and ferumoxytol, and the laboratory preparation MION-46 in rat brain. METHODS: Iron oxide agents were administered by intracerebral inoculation or intraarterially after osmotic blood-brain barrier opening in normal rats and intravenously in nude rats with intracerebral tumor xenografts. Rat brains were imaged by MRI at multiple time points and then were assessed for iron histochemistry and pathological features. RESULTS: After intracerebral injection, MRI signal changes declined slowly over weeks to months. After transvascular delivery, transient (3 d) enhancement was seen with ferumoxtran-10 or ferumoxytol, whereas ferumoxides induced long-term (28 d) signal dropout. No pathological brain cell or myelin changes were detected after delivery of the clinical iron oxide agents to normal brains. In tumor models, ferumoxtran-10 enhanced one small-cell lung carcinoma intracerebral tumor, which correlated with iron staining in cells with macrophage morphological features at the tumor margin. Little enhancement was seen in two other models. CONCLUSION: These studies demonstrate the safety and efficacy of iron oxide-based MRI contrast agents in the brain and provide imaging parameters and time course data for future studies in brain tumors and neurological lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weissleder, R., Elizondo, G., Wittenberg, J., Rabito, C. A., Bengele, H. H., & Josephson, L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326474 · Cited by 1,028
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Jung, C. W., & Jacobs, P. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00024-b · Cited by 622
Arbab, A. S., Bashaw, L. A., Miller, B. R., Jordan, E. K., Lewis, B. K., Kalish, H., & Frank, J. A. (2003) · Radiology · doi:10.1148/radiol.2293021215 · Cited by 552
Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI
Arbab, A. S., Yocum, G. T., Kalish, H., Jordan, E. K., Anderson, S. A., Khakoo, A. Y., Read, E. J., & Frank, J. A. (2004) · Blood · doi:10.1182/blood-2004-02-0655 · Cited by 529
(2003) · PubMed · Cited by 357
Tumoral Distribution of Long-circulating Dextran-coated Iron Oxide Nanoparticles in a Rodent Model
Moore, A., Marecos, E., Bogdanov, A., & Weissleder, R. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe19568 · Cited by 343
Magnetically labeled cells can be detected by MR imaging
Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070140 · Cited by 336
Mechanisms of Disease: The Blood-Brain Barrier
Neuwelt, E. A. (2004) · Neurosurgery · doi:10.1227/01.neu.0000097715.11966.8e · Cited by 314
Self-citationAnzai, Y., Piccoli, C. W., Outwater, E. K., Stanford, W., Bluemke, D. A., Nurenberg, P., Saini, S., Maravilla, K. R., Feldman, D. E., Schmiedl, U. P., et al. (2003) · Radiology · doi:10.1148/radiol.2283020872 · Cited by 289
Ros, P. R., Freeny, P. C., Harms, S. E., Seltzer, S. E., Davis, P. L., Chan, T. W., Stillman, A. E., Muroff, L. R., Runge, V. M., & Nissenbaum, M. A. (1995) · Radiology · doi:10.1148/radiology.196.2.7617864 · Cited by 278
Anderson, S. A., Glod, J., Arbab, A. S., Noel, M., Ashari, P., Fine, H. A., & Frank, J. A. (2005) · Blood · doi:10.1182/blood-2004-06-2222 · Cited by 254
Enochs, W. S., Harsh, G., Hochberg, F., & Weissleder, R. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199902)9:2<228::aid-jmri12>3.0.co;2-k · Cited by 253
The Metabolism of Neuronal Iron and Its Pathogenic Role in Neurological Disease: Review
MOOS, T., & MORGAN, E. H. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1306.002 · Cited by 234
Corot, C., Petry, K. G., Trivedi, R., Saleh, A., Jonkmanns, C., Le Bas, J.-F., Blezer, E., Rausch, M., Brochet, B., Foster-Gareau, P., et al. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000135980.08491.33 · Cited by 231
Neuwelt, E. A., Várallyay, P., Bagó, A. G., Muldoon, L. L., Nesbit, G., & Nixon, R. (2004) · Neuropathology and Applied Neurobiology · doi:10.1111/j.1365-2990.2004.00557.x · Cited by 219
Self-citationIn vivo macrophage activity imaging in the central nervous system detected by magnetic resonance
Dousset, V., Delalande, C., Ballarino, L., Quesson, B., Seilhan, D., Coussemacq, M., Thiaudi�re, E., Brochet, B., Canioni, P., & Caill�, J.-M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2<329::aid-mrm17>3.0.co;2-z · Cited by 204
Magnetic resonance imaging of labeled T‐cells in a mouse model of multiple sclerosis
Anderson, S. A., Shukaliak‐Quandt, J., Jordan, E. K., Arbab, A. S., Martin, R., McFarland, H., & Frank, J. A. (2004) · Annals of Neurology · doi:10.1002/ana.20066 · Cited by 155
Várallyay, P., Nesbit, G. M., Muldoon, L. L., Nixon, R. R., Delashaw, J. B., Cohen, J. I., Petrillo, A., Rink, D., & Neuwelt, E. A. (2002) · PubMed Central · Cited by 149
Self-citationDelivery of Virus-sized Iron Oxide Particles to Rodent CNS Neurons
Neuwelt, E. A., Weissleder, R., Nilaver, G., Kroll, R. A., Roman-Goldstein, S., Szumowski, J., Pagel, M. A., Jones, R. S., Remsen, L. G., McCormick, C. I., et al. (1994) · Neurosurgery · doi:10.1097/00006123-199404000-00048 · Cited by 135
Self-citationMuldoon, L. L., Nilaver, G., Kroll, R. A., Pagel, M. A., Breakefield, X. O., Chiocca, E. A., Davidson, B. L., Weissleder, R., & Neuwelt, E. A. (1995) · Europe PMC (PubMed Central) · Cited by 121
Self-citationMR imaging of phagocytosis in experimental gliomas.
Zimmer, C., Weissleder, R., Poss, K., Bogdanova, A., Wright, S. C., & Enochs, W. S. (1995) · Radiology · doi:10.1148/radiology.197.2.7480707 · Cited by 121
Blood Pool MR Angiography of Aortic Stent-Graft Endoleak
Ersoy, H., Jacobs, P., Kent, C. K., & Prince, M. R. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.5.1821181 · Cited by 119
Kroll, R. A., Pagel, M. A., Muldoon, L. L., Roman-Goldstein, S., & Neuwelt, E. A. (1996) · Neurosurgery · doi:10.1097/00006123-199604000-00024 · Cited by 114
Self-citationYancy, A. D., Olzinski, A. R., Hu, T. C., Lenhard, S. C., Aravindhan, K., Gruver, S., Jacobs, P. M., Willette, R. N., & Jucker, B. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20283 · Cited by 107
Manninger, S., Muldoon, L. L., Nesbit, G. M., Murillo, T. P., Jacobs, P. M., & Neuwelt, E. A. (2005) · PubMed · Cited by 77
Self-citationPrince, M. R., Zhang, H. L., Chabra, S. G., Jacobs, P., & Wang, Y. (2003) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2003-00092 · Cited by 73
Xu, S., Jordan, E. K., Brocke, S., Bulte, J. W. M., Quigley, L., Tresser, N., Ostuni, J. L., Yang, Y., McFarland, H. F., & Frank, J. A. (1998) · Journal of Neuroscience Research · doi:10.1002/(sici)1097-4547(19980601)52:5<549::aid-jnr7>3.0.co;2-c · Cited by 72
Muldoon, L. L., Pagel, M. A., Kroll, R. A., Roman-Goldstein, S., Jones, R. S., & Neuwelt, E. A. (1999) · PubMed · Cited by 71
Self-citationRemsen, L. G., Pagel, M. A., McCormick, C. I., Fiamengo, S. A., Sexton, G. J., & Neuwelt, E. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199903000-00018 · Cited by 71
Self-citationMagnetic Iron Compounds in Neurological Disorders
Dobson, J. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1306.016 · Cited by 57
Hunt, M. A., Bagó, A. G., & Neuwelt, E. A. (2005) · PubMed · Cited by 51
Self-citationMuldoon, L. L., Varallyay, P., Kraemer, D. F., Kiwic, G., Pinkston, K., Walker‐Rosenfeld, S. L., & Neuwelt, E. A. (2004) · Neuropathology and Applied Neurobiology · doi:10.1046/j.0305-1846.2003.00512.x · Cited by 44
Self-citationRogers, J. M., Jung, C. W., Lewis, J. M., & Groman, E. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00090-3 · Cited by 36
KrolI, R. A., Pagel, M. A., Muldoon, L. L., Roman-Goldstein, S., Neuwelt, E. A., Neuwelt, E. A., & Neuwelt, E. A. (1996) · Neurosurgery · doi:10.1227/00006123-199604000-00024
Self-citation
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Magnetic nanoparticles: preparation, physical properties, and applications in biomedicine
Akbarzadeh, A., Samiei, M., & Davaran, S. (2012) · Nanoscale Research Letters · doi:10.1186/1556-276x-7-144 · Cited by 1,241
Magnetic nanoparticles for theragnostics
Shubayev, V. I., Pisanic, T. R., & Jin, S. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.007 · Cited by 1,028
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Toxicology and clinical potential of nanoparticles
Yildirimer, L., Thanh, N. T. K., Loizidou, M., & Seifalian, A. M. (2011) · Nano Today · doi:10.1016/j.nantod.2011.10.001 · Cited by 676
Metadata
- Authors
- Muldoon, L. L., Manninger, S., Pinkston, K. E., & Neuwelt, E. A.
- Venue
- Neurosurgery
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2005-10-01
- Volume
- 57
- Issue
- 4
- Pages
- 785-796
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1994139105
- Cited by
- 190
- References
- 36
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.