Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 255

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Auto-Titrating Versus Standard Continuous Positive Airway Pressure for the Treatment of Obstructive Sleep Apnea: Results of a Meta-analysis

Ayas, Najib T., Patel, Sanjay R., Malhotra, Atul, Schulzer, Michael, Malhotra, Mark, Jung, David, Fleetham, John, White, David P. · 2004 · Sleep

Abstract

STUDY OBJECTIVE: To compare the effectiveness of auto-titrating continuous positive airway pressure (APAP) versus conventional continuous positive airway pressure (CPAP) in reducing the apnea-hypopnea index (AHI), reducing the mean airway pressure, improving subjective sleepiness, and improving treatment adherence in patients with obstructive sleep apnea (OSA). DESIGN: Meta-analysis and metaregression of published randomized trials comparing APAP to CPAP. SETTING: N/A. PARTICIPANTS: N/A. INTERVENTIONS: N/A. RESULTS: We identified 9 randomized trials studying a total of 282 patients. Compared to CPAP, there was no significant advantage of APAP in reducing AHI or sleepiness (pooled APAP-CPAP posttreatment AHI and Epworth Sleepiness Scale score = -0.20 events per hour, 95% confidence interval:[-0.74,0.35], and -0.56 [-1.4,0.3] respectively). The use of APAP reduced the mean applied pressure across the night by 2.2 cm water [1.9,2.5] compared to CPAP. Adherence with therapy was not substantially improved with APAP; pooled estimate of improvement was 0.20 hours per night ([-0.16,0.57], P = .28) using a random-effects model. CONCLUSIONS: Compared to standard CPAP, APAP is associated with a reduction in mean pressure. However, APAP and standard CPAP were similar in adherence and their ability to eliminate respiratory events and to improve subjective sleepiness. Given that APAP is more costly than standard CPAP, APAP should not be considered first-line chronic therapy in all patients with OSA. However, APAP may be useful in other situations (eg, home titrations, detection of mouth leak) or in certain subgroups of patients with OSA. Identifying circumstances in which APAP is a definite improvement over CPAP in terms of costs or effects should be the focus of future studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/27.2.249

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 255

Metadata

Authors
Ayas, N. T., Patel, S. R., Malhotra, A., Schulzer, M., Malhotra, M., Jung, D., Fleetham, J., & White, D. P.
Venue
Sleep
Published
2004-03
Volume
27
Issue
2
Pages
249-253
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2035872
Cited by
255
References
18
FWCI
10.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.