The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
19 F magnetic resonance imaging for stem/progenitor cell tracking with multiple unique perfluorocarbon nanobeacons
Abstract
MRI has been employed to elucidate the migratory behavior of stem/progenitor cells noninva‐sively in vivo with traditional proton ( 1 H) imaging of iron oxide nanoparticle‐labeled cells. Alternatively, we demonstrate that fluorine ( 19 F) MRI of cells labeled with different types of liquid perfluorocarbon (PFC) nanoparticles produces unique and sensitive cell markers distinct from any tissue background signal. To define the utility for cell tracking, mononuclear cells harvested from human umbilical cord blood were grown under proendothelial conditions and labeled with nanoparticles composed of two distinct PFC cores (perfluorooctylbromide and perfluoro‐15‐crown‐5 ether). The sensitivity for detecting and imaging labeled cells was defined on 11.7T (research) and 1.5T (clinical) scanners. Stem/progenitor cells (CD34 + CD133 + CD31 + ) readily internalized PFC nanoparticles without aid of adjunctive labeling techniques, and cells remained functional in vivo. PFC‐labeled cells exhibited distinct 19 F signals and were readily detected after both local and intravenous injection. PFC nanoparticles provide an unequivocal and unique signature for stem/progenitor cells, enable spatial cell localization with 19 F MRI, and permit quantification and detection of multiple fluorine signatures via 19 F MR spectroscopy. This method should facilitate longitudinal investigation of cellular events in vivo for multiple cell types simultaneously.—Partlow, K. C., Chen, J., Brant, J. A., Neubauer, A. M., Meyerrose, T. E., Creer, M. H., Nolta, J. A., Caruthers, S. D., Lanza, G. M., Wickline, S. A. 19F magnetic resonance imaging for stem/progenitor cell tracking with multiple unique perfluorocarbon nanobeacons. FASEB J. 21, 1647–1654 (2007)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of Putative Progenitor Endothelial Cells for Angiogenesis
Asahara, T., Murohara, T., Sullivan, A., Silver, M., van der Zee, R., Li, T., Witzenbichler, B., Schatteman, G., & Isner, J. M. (1997) · Science · doi:10.1126/science.275.5302.964 · Cited by 8,725
Therapeutic stem and progenitor cell transplantation for organ vascularization and regeneration
Rafii, S., & Lyden, D. (2003) · Nature Medicine · doi:10.1038/nm0603-702 · Cited by 1,577
Voyta, J. C., Via, D. P., Butterfield, C. E., & Zetter, B. R. (1984) · The Journal of cell biology · doi:10.1083/jcb.99.6.2034 · Cited by 1,239
In Vivo Magnetic Resonance Imaging of Mesenchymal Stem Cells in Myocardial Infarction
Kraitchman, D. L., Heldman, A. W., Atalar, E., Amado, L. C., Martin, B. J., Pittenger, M. F., Hare, J. M., & Bulte, J. W. M. (2003) · Circulation · doi:10.1161/01.cir.0000070931.62772.4e · Cited by 710
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
In vivo imaging platform for tracking immunotherapeutic cells
Ahrens, E. T., Flores, R., Xu, H., & Morel, P. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1121 · Cited by 620
Aicher, A., Brenner, W., Zuhayra, M., Badorff, C., Massoudi, S., Assmus, B., Eckey, T., Henze, E., Zeiher, A. M., & Dimmeler, S. (2003) · Circulation · doi:10.1161/01.cir.0000062649.63838.c9 · Cited by 559
Serial Cardiac Magnetic Resonance Imaging of Injected Mesenchymal Stem Cells
Hill, J. M., Dick, A. J., Raman, V. K., Thompson, R. B., Yu, Z.-X., Hinds, K. A., Pessanha, B. S. S., Guttman, M. A., Varney, T. R., Martin, B. J., et al. (2003) · Circulation · doi:10.1161/01.cir.0000084537.66419.7a · Cited by 458
A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3334 · Cited by 406
Self-citationPositive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles
Cunningham, C. H., Arai, T., Yang, P. C., McConnell, M. V., Pauly, J. M., & Conolly, S. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20477 · Cited by 403
Kim, S.-W., Han, H., Chae, G.-T., Lee, S.-H., Bo, S., Yoon, J.-H., Lee, Y.-S., Lee, K.-S., Park, H.-K., & Kang, K.-S. (2006) · Stem Cells · doi:10.1634/stemcells.2005-0365 · Cited by 237
Instant MR labeling of stem cells using magnetoelectroporation
Walczak, P., Kedziorek, D. A., Gilad, A. A., Lin, S., & Bulte, J. W. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20701 · Cited by 215
Arbab, A. S., Yocum, G. T., Wilson, L. B., Parwana, A., Jordan, E. K., Kalish, H., & Frank, J. A. (2004) · Molecular Imaging · doi:10.1162/15353500200403190 · Cited by 214
Quantitative “magnetic resonance immunohistochemistry” with ligand‐targeted 19F nanoparticles
Morawski, A. M., Winter, P. M., Yu, X., Fuhrhop, R. W., Scott, M. J., Hockett, F., Robertson, J. D., Gaffney, P. J., Lanza, G. M., & Wickline, S. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20287 · Cited by 192
Self-citationMonitoring Cell Therapy Using Iron Oxide MR Contrast Agents
M. Bulte, J., & Kraitchman, D. (2004) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201043376526 · Cited by 172
Arbab, A. S., Frenkel, V., Pandit, S. D., Anderson, S. A., Yocum, G. T., Bur, M., Khuu, H. M., Read, E. J., & Frank, J. A. (2006) · Stem Cells · doi:10.1634/stemcells.2005-0017 · Cited by 167
Daldrup-Link, H. E., Meier, R., Rudelius, M., Piontek, G., Piert, M., Metz, S., Settles, M., Uherek, C., Wels, W., Schlegel, J., et al. (2005) · European Radiology · doi:10.1007/s00330-004-2526-7 · Cited by 167
Eggermann, J. (2003) · Cardiovascular Research · doi:10.1016/s0008-6363(03)00252-9 · Cited by 150
Dardzinski, B. J., & Sotak, C. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320112 · Cited by 150
Identification of hematopoietic stem/progenitor cells: strength and drawbacks of functional assays
Coulombel, L. (2004) · Oncogene · doi:10.1038/sj.onc.1207941 · Cited by 137
Naruse, K., Hamada, Y., Nakashima, E., Kato, K., Mizubayashi, R., Kamiya, H., Yuzawa, Y., Matsuo, S., Murohara, T., Matsubara, T., et al. (2005) · Diabetes · doi:10.2337/diabetes.54.6.1823 · Cited by 123
van den Bos, E. J., Wagner, A., Mahrholdt, H., Thompson, R. B., Morimoto, Y., Sutton, B. S., Judd, R. M., & Taylor, D. A. (2003) · Cell Transplantation · doi:10.3727/000000003108747352 · Cited by 111
Stroh, A., Faber, C., Neuberger, T., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.014 · Cited by 110
Caruthers, S. D., Neubauer, A. M., Hockett, F. D., Lamerichs, R. M. J. N., Winter, P. M., Scott, M. J., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199281.60135.6a · Cited by 101
Self-citation1H/19F Magnetic Resonance Molecular Imaging with Perfluorocarbon Nanoparticles
Lanza, G. M., Winter, P. M., Neubauer, A. M., Caruthers, S. D., Hockett, F. D., & Wickline, S. A. (2005) · Current topics in developmental biology/Current Topics in Developmental Biology · doi:10.1016/s0070-2153(05)70003-x · Cited by 75
Self-citationAoki, M., Yasutake, M., & Murohara, T. (2004) · Stem Cells · doi:10.1634/stemcells.22-6-994 · Cited by 75
Fan, C. L., Li, Y., Gao, P., Liu, J., Zhang, X. J., & Zhu, D. L. (2003) · PubMed · Cited by 48
Temperature dependence of acoustic impedance for specific fluorocarbon liquids
Marsh, J. N., Hall, C. S., Wickline, S. A., & Lanza, G. M. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1517251 · Cited by 47
Self-citationLiu, J. W., Pernod, G., Dunoyer-Geindre, S., Fish, R. J., Yang, H., Bounameaux, H., & Kruithof, E. K. O. (2005) · Stem Cells · doi:10.1634/stemcells.2004-0364 · Cited by 27
Hexafluorobenzene: a Sensitive 19F NMR Indicator of Tumor Oxygenation
Mason, R. P., Rodbumrung, W., & Antich, P. P. (1996) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199605)9:3<125::aid-nbm405>3.0.co;2-f · Cited by 9
Cited by
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Noninvasive cell-tracking methods
Kircher, M. F., Gambhir, S. S., & Grimm, J. (2011) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2011.141 · Cited by 501
Fluorine (19F) MRS and MRI in biomedicine
Ruiz‐Cabello, J., Barnett, B. P., Bottomley, P. A., & Bulte, J. W. M. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1570 · Cited by 489
Nanoparticles for biomedical imaging
Nune, S. K., Gunda, P., Thallapally, P. K., Lin, Y.-Y., Laird Forrest, M., & Berkland, C. J. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240903229031 · Cited by 450
Applications of Nanobiotechnology in Clinical Diagnostics
Jain, K. K. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.090795 · Cited by 381
Metadata
- Authors
- Partlow, K. C., Chen, J., Brant, J. A., Neubauer, A. M., Meyerrose, T. E., Creer, M. H., Nolta, J. A., Caruthers, S. D., Lanza, G. M., & Wicldine, S. A.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 2007-02-06
- Volume
- 21
- Issue
- 8
- Pages
- 1647-1654
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W2157297527
- Cited by
- 306
- References
- 30
- FWCI
- 18.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.