Perfusion Imaging Using Arterial Spin Labeling
The DOI matches its Crossref record; 165 of the 165 references it cites were found in a registry or an index.
Abstract
Arterial spin labeling is a magnetic resonance method for the measurement of cerebral blood flow. In its simplest form, the perfusion contrast in the images gathered by this technique comes from the subtraction of two successively acquired images: one with, and one without, proximal labeling of arterial water spins after a small delay time. Over the last decade, the method has moved from the experimental laboratory to the clinical environment. Furthermore, numerous improvements, ranging from new pulse sequence implementations to extensive theoretical studies, have broadened its reach and extended its potential applications. In this review, the multiple facets of this powerful yet difficult technique are discussed. Different implementations are compared, the theoretical background is summarized, and potential applications of various implementations in research as well as in the daily clinical routine are proposed. Finally, a summary of the new developments and emerging techniques in this field is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“One of the original reasons for the development of ASL was the drive to develop a fully noninvasive technique allowing measuring the local changes in CBF related to a functional task.(19,20,112) Indeed, ASL techniques developed in parallel with functional MRI (fMRI) techniques based on the blood oxygen level-dependent…”
MethodKety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS
Kety, S. S., & Schmidt, C. F. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.143.1.53 · Cited by 1,053
Cited by
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Self-citationPerfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Causal mapping of human brain function
Siddiqi, S. H., Kording, K. P., Parvizi, J., & Fox, M. D. (2022) · Nature Reviews Neuroscience · doi:10.1038/s41583-022-00583-8 · Cited by 338
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Self-citationA neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Self-citationBarrett, T., Brechbiel, M., Bernardo, M., & Choyke, P. L. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20991 · Cited by 266
Regression algorithm correcting for partial volume effects in arterial spin labeling MRI
Asllani, I., Borogovac, A., & Brown, T. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21670 · Cited by 241
“m P P 1 P M [8]”
Noguchi, T., Yoshiura, T., Hiwatashi, A., Togao, O., Yamashita, K., Nagao, E., Shono, T., Mizoguchi, M., Nagata, S., Sasaki, T., et al. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0903 · Cited by 226
“flow measurement was limited by a low signal intensity-tonoise ratio, which is inherent in ASL-PI.(30,31) This could be serious, especially in the posterior fossa, where signal intensity loss can occur due to the susceptibility effect by the skull base bone.”
BackgroundInfluentialArterial spin labeling in neuroimaging
Petcharunpaisan, S. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.384 · Cited by 225
A signal processing model for arterial spin labeling functional MRI
Liu, T. T., & Wong, E. C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.047 · Cited by 215
“…resonance imaging (fMRI) using arterial spin labeling (ASL) methods has the potential to provide better localization of the functional signal to sites of neural activity as compared to blood oxygenation level dependent (BOLD) contrast fMRI (Duong et al., 2001; Golay et al., 2004; Luh et al., 2000).”
MethodCan arterial spin labeling detect white matter perfusion signal?
van Osch, M. J. P., Teeuwisse, W. M., van Walderveen, M. A. A., Hendrikse, J., Kies, D. A., & van Buchem, M. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22002 · Cited by 204
Self-citationFunctional imaging and related techniques: An introduction for rehabilitation researchers
Crosson, B., Ford, A., McGregor, K. M., Meinzer, M., Cheshkov, S., Li, X., Walker-Batson, D., & Briggs, R. W. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.02.0017 · Cited by 199
“ ASL measures CBF using an endogenous tracer, blood water, to noninvasively measure tissue perfusion to evaluate the tissue viability or functionality [14–15].”
MethodComparative overview of brain perfusion imaging techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J. F., et al. (2005) · Journal of Neuroradiology · doi:10.1016/s0150-9861(05)83159-1 · Cited by 185
Partial volume correction of multiple inversion time arterial spin labeling MRI data
Chappell, M. A., Groves, A. R., MacIntosh, B. J., Donahue, M. J., Jezzard, P., & Woolrich, M. W. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22641 · Cited by 179
“Arterial spin labeling (ASL) MRI provides noninvasive measurements of cerebral blood flow (CBF) using an endogenous tracer generated by radiofrequency inversion of inflowing blood water protons (1,2).”
BackgroundAsllani, I., Habeck, C., Scarmeas, N., Borogovac, A., Brown, T. R., & Stern, Y. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600570 · Cited by 172
“Arterial spin labeling techniques have been used in a variety of applications in both disease and normal brain function (Alsop and Detre, 1998; Golay et al, 2004).”
Physiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
“In an arterial spin labeling (ASL) experiment, a series of control images and tag images in which arterial blood is either fully relaxed or magnetically inverted, respectively, is acquired (Golay et al., 2004).”
BackgroundMarinkovic, K., Rickenbacher, E., Azma, S., & Artsy, E. (2012) · Human Brain Mapping · doi:10.1002/hbm.21213 · Cited by 92
“Future ASL studies are needed to investigate potential dose-related effects of alcohol intoxication on cerebral perfusion and BOLD contrast in order to disambiguate potential vascular confounds from neural activity [Brown et al., 2007; Liu et al., 2004].”
MethodExtraversion and its positive emotional core—further evidence from neuroscience
Hermes, M., Hagemann, D., Naumann, E., & Walter, C. (2011) · Emotion · doi:10.1037/a0021550 · Cited by 39
Schouw, M. L. J., Kaag, A. M., Caan, M. W. A., Heijtel, D. F. R., Majoie, C. B. L. M., Nederveen, A. J., Booij, J., & Reneman, L. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.056 · Cited by 19
“By subtracting labeled and unlabeled images, a CBFmap is generated, which can be used for visualization and quantification of CBF (Golay et al., 2004).”
Brain imaging in stroke: insight beyond diagnosis.
Nour, M., & Liebeskind, D. S. (2011) · Neurotherapeutics · doi:10.1007/s13311-011-0046-0 · Cited by 15
Metadata
- Authors
- Golay, X., Hendrikse, J., & Lim, T. C. C.
- Venue
- Topics in Magnetic Resonance Imaging
- Published
- 2004-02
- Volume
- 15
- Issue
- 1
- Pages
- 10-27
- ISSN
- 0899-3459 (ISSN-L)
- OpenAlex
- W2076212130
- Cited by
- 256
- References
- 165
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.