Perfusion Imaging Using Arterial Spin Labeling
The DOI matches its Crossref record; 165 of the 165 references it cites were found in a registry or an index.
Abstract
Arterial spin labeling is a magnetic resonance method for the measurement of cerebral blood flow. In its simplest form, the perfusion contrast in the images gathered by this technique comes from the subtraction of two successively acquired images: one with, and one without, proximal labeling of arterial water spins after a small delay time. Over the last decade, the method has moved from the experimental laboratory to the clinical environment. Furthermore, numerous improvements, ranging from new pulse sequence implementations to extensive theoretical studies, have broadened its reach and extended its potential applications. In this review, the multiple facets of this powerful yet difficult technique are discussed. Different implementations are compared, the theoretical background is summarized, and potential applications of various implementations in research as well as in the daily clinical routine are proposed. Finally, a summary of the new developments and emerging techniques in this field is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“One of the original reasons for the development of ASL was the drive to develop a fully noninvasive technique allowing measuring the local changes in CBF related to a functional task.(19,20,112) Indeed, ASL techniques developed in parallel with functional MRI (fMRI) techniques based on the blood oxygen level-dependent…”
MethodKety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS
Kety, S. S., & Schmidt, C. F. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.143.1.53 · Cited by 1,053
Calibrated functional MRI: Mapping the dynamics of oxidative metabolism
Davis, T. L., Kwong, K. K., Weisskoff, R. M., & Rosen, B. R. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1834 · Cited by 1,052
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Quantitative interpretation of magnetization transfer
Henkelman, R. M., Huang, X., Xiang, Q., Stanisz, G. J., Swanson, S. D., & Bronskill, M. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290607 · Cited by 734
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Wong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9403 · Cited by 563
Experimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Powers, W. J., Grubb, R. L., Darriet, D., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.89 · Cited by 425
Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
Alsop, D. C., Detre, J. A., & Grossman, M. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200001)47:1<93::aid-ana15>3.0.co;2-8 · Cited by 409
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Multisection cerebral blood flow MR imaging with continuous arterial spin labeling.
Alsop, D. C., & Detre, J. A. (1998) · Radiology · doi:10.1148/radiology.208.2.9680569 · Cited by 404
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Warmuth, C., Günther, M., & Zimmer, C. (2003) · Radiology · doi:10.1148/radiol.2282020409 · Cited by 364
Localized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Tissue specific perfusion imaging using arterial spin labeling
Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070112 · Cited by 335
Ye, F. Q., Berman, K. F., Ellmore, T., Esposito, G., van Horn, J. D., Yang, Y., Duyn, J., Smith, A. M., Frank, J. A., Weinberger, D. R., et al. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<450::aid-mrm16>3.0.co;2-0 · Cited by 317
Arterial spin labeling perfusion fMRI with very low task frequency
Wang, J., Aguirre, G. K., Kimberg, D. Y., Roc, A. C., Li, L., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10437 · Cited by 316
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Ye, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)
Wang, J., Alsop, D. C., Song, H. K., Maldjian, J. A., Tang, K., Salvucci, A. E., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10559 · Cited by 275
Kim, S.-G., Rostrup, E., Larsson, H. B. W., Ogawa, S., & Paulson, O. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1152::aid-mrm11>3.0.co;2-t · Cited by 268
Sicard, K., Shen, Q., Brevard, M. E., Sullivan, R., Ferris, C. F., King, J. A., & Duong, T. Q. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200304000-00011 · Cited by 263
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400303 · Cited by 250
Kim, S., & Tsekos, N. V. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370321 · Cited by 247
Observation of a fast response in functional MR
Ernst, T., & Hennig, J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320122 · Cited by 240
Pediatric perfusion imaging using pulsed arterial spin labeling
Wang, J., Licht, D. J., Jahng, G., Liu, C., Rubin, J. T., Haselgrove, J., Zimmerman, R. A., & Detre, J. A. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10372 · Cited by 238
Silva, A. C., Lee, S.-P., Yang, G., Iadecola, C., & Kim, S.-G. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199908000-00006 · Cited by 233
Kim Cmrr, S., & Uĝurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380110 · Cited by 220
Single‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1282 · Cited by 206
Parkes, L. M., & Tofts, P. S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10180 · Cited by 202
Nonlinear temporal dynamics of the cerebral blood flow response
Miller, K. L., Luh, W., Liu, T. T., Martinez, A., Obata, T., Wong, E. C., Frank, L. R., & Buxton, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1020 · Cited by 200
Silva, A. C., Lee, S.-P., Iadecola, C., & Kim, S.-G. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200001000-00025 · Cited by 165
Flow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI
Hendrikse, J., van der Grond, J., Lu, H., van Zijl, P. C. M., & Golay, X. (2004) · Stroke · doi:10.1161/01.str.0000120312.26163.ec · Cited by 164
Self-citationWolf, R. L., Alsop, D. C., Levy-Reis, I., Meyer, P. T., Maldjian, J. A., Gonzalez-Atavales, J. B., French, J. A., Alavi, A. A., & Detre, J. A. (2001) · PubMed · Cited by 160
NMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular Spins
Zhang, W., Silva, A. C., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330310 · Cited by 158
Multi‐Slice MRI of Rat Brain Perfusion During Amphetamine Stimulation Using Arterial Spin Labeling
Silva, A. C., Zhang, W., Williams, D. S., & Koretsky, A. P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330210 · Cited by 156
Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
Yang, Y., Frank, J. A., Hou, L., Ye, F. Q., McLaughlin, A. C., & Duyn, J. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390520 · Cited by 155
Perfusion imaging with compensation for asymmetric magnetization transfer effects
Pekar, J., Jezzard, P., Roberts, D. A., Leigh, J. S., Frank, J. A., & McLaughlin, A. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350110 · Cited by 155
Mai, V. M., & Berr, S. S. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3<483::aid-jmri18>3.0.co;2-# · Cited by 154
Moore, D. F., Ye, F., Schiffmann, R., & Butman, J. A. (2003) · PubMed Central · Cited by 145
Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
Zaharchuk, G., Ledden, P. J., Kwong, K. K., Reese, T. G., Rosen, B. R., & Wald, L. L. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4>3.0.co;2-0 · Cited by 141
Zhang, W., Williams, D. S., & Koretsky, A. P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290323 · Cited by 139
Calamante, F., Lythgoe, M. F., Pell, G. S., Thomas, D. L., King, M. D., Busza, A. L., Sotak, C. H., Williams, S. R., Ordidge, R. J., & Gadian, D. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>3.0.co;2-2 · Cited by 138
Zaharchuk, G., Mandeville, J. B., Bogdanov, A. A., Weissleder, R., Rosen, B. R., & Marota, J. J. A. (1999) · Stroke · doi:10.1161/01.str.30.10.2197 · Cited by 136
Luh, W.-M., Wong, E. C., Bandettini, P. A., Ward, B. D., & Hyde, J. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<137::aid-mrm20>3.0.co;2-r · Cited by 136
Brown, G. G., Zorrilla, L. T. E., Georgy, B., Kindermann, S. S., Wong, E. C., & Buxton, R. B. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000071887.63724.b2 · Cited by 132
Stimulus-Dependent BOLD and Perfusion Dynamics in Human V1
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · NeuroImage · doi:10.1006/nimg.1999.0443 · Cited by 130
Detre, J. A., Samuels, O. B., Alsop, D. C., Gonzalez-Atavales, J. B., Kasner, S. E., & Raps, E. C. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199911)10:5<870::aid-jmri36>3.0.co;2-d · Cited by 127
Dynamic imaging of perfusion in human skeletal muscle during exercise with arterial spin labeling
Frank, L. R., Wong, E. C., Haseler, L. J., & Buxton, R. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199908)42:2<258::aid-mrm7>3.0.co;2-e · Cited by 126
Floyd, T. F., Ratcliffe, S. J., Wang, J., Resch, B., & Detre, J. A. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10416 · Cited by 126
Age Dependence of Total Cerebral Blood Flow Volume from Childhood to Adulthood
Schöning, M., & Hartig, B. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00007 · Cited by 125
In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain
Duong, T. Q., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<393::aid-mrm11>3.0.co;2-k · Cited by 124
Raynaud, J. S., Duteil, S., Vaughan, J. T., Hennel, F., Wary, C., Leroy‐Willig, A., & Carlier, P. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1192 · Cited by 123
Belle, V., Kahler, E., Waller, C., Rommel, E., Voll, S., Hiller, K., Bauer, W. R., & Haase, A. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080610 · Cited by 121
Two-Compartment Exchange Model for Perfusion Quantification Using Arterial Spin Tagging
Zhou, J., Wilson, D. A., Ulatowski, J. A., Traystman, R. J., & van Zijl, P. C. M. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200104000-00013 · Cited by 119
Sickle Cell Disease: Continuous Arterial Spin-labeling Perfusion MR Imaging in Children
Oguz, K. K., Golay, X., Pizzini, F. B., Freer, C. A., Winrow, N., Ichord, R., Casella, J. F., van Zijl, P. C. M., & Melhem, E. R. (2003) · Radiology · doi:10.1148/radiol.2272020903 · Cited by 116
Self-citationMagnetic Resonance Imaging Contrast Enhancement of Brain Tumors at 3 Tesla Versus 1.5 Tesla
Nöebauer-Huhmann, I.-M., Ba‐Ssalamah, A., Mlynárik, V., Barth, M., Schöggl, A., Heimberger, K., Matula, C., Fog, A., Kaider, A., & Trattnig, S. (2002) · Investigative Radiology · doi:10.1097/00004424-200203000-00003 · Cited by 115
Effect of Contrast Dose and Field Strength in the Magnetic Resonance Detection of Brain Metastases
Ba‐Ssalamah, A., Nöebauer-Huhmann, I.-M., Pinker, K., Schibany, N., PROKESCH, R. W., Mehrain, S., Mlynárik, V., Fog, A., Heimberger, K., & Trattnig, S. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000067488.57101.bd · Cited by 113
Darby, D., Nobre, A. C., Thangaraj, V., Edelman, R. R., Mesulam, M. M., & Warach, S. J. (1996) · NeuroImage · doi:10.1006/nimg.1996.0006 · Cited by 111
Silva, A. C., Zhang, W., Williams, D. S., Koretsky, A. P., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370110 · Cited by 109
Imaging blood flow in brain tumors using arterial spin labeling
Silva, A. C., Kim, S., & Garwood, M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<169::aid-mrm1>3.0.co;2-u · Cited by 108
Lawrence, K. S., Frank, J. A., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<440::aid-mrm15>3.0.co;2-6 · Cited by 108
Schwarzbauer, C., Morrissey, S. P., & Haase, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350413 · Cited by 106
Golay, X., Stuber, M., Pruessmann, K. P., Meier, D., & Boesiger, P. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3<454::aid-jmri14>3.0.co;2-b · Cited by 105
Self-citationTsekos, N. V., Zhang, F., Merkle, H., Nagayama, M., ladecola, C., & Kim, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390409 · Cited by 105
Waller, C., Kahler, E., Hiller, K., Hu, K., Nahrendorf, M., Voll, S., Haase, A., Ertl, G., & Bauer, W. R. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap07189 · Cited by 104
Silva, A. C., Williams, D. S., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380211 · Cited by 103
Siewert, B., Schlaug, G., Edelman, R. R., & Warach, S. (1997) · Neurology · doi:10.1212/wnl.48.3.673 · Cited by 101
EPISTAR MRI: Multislice mapping of cerebral blood flow
Edelman, R. R., & Chen, Q. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400603 · Cited by 101
Kim, S.-G., Tsekos, N. V., & Ashe, J. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<191::aid-nbm460>3.0.co;2-r · Cited by 99
Neuroimaging studies in Rett syndrome
Naidu, S., Kaufmann, W. E., Abrams, M. T., Pearlson, G. D., Lanham, D. C., Fredericksen, K., Barker, P. B., Horská, A., Golay, X., Mori, S., et al. (2001) · Brain and Development · doi:10.1016/s0387-7604(01)00381-3 · Cited by 97
Self-citationSilva, A. C., & Kim, S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<425::aid-mrm3>3.0.co;2-s · Cited by 94
The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling
Maccotta, L., Detre, J. A., & Alsop, D. C. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<216::aid-nbm468>3.0.co;2-u · Cited by 93
Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE
Karger, N., Biederer, J., Lüsse, S., Grimm, J., Steffens, J.-C., Heller, M., & Glüer, C.-C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00155-7 · Cited by 89
Local perfusion and metabolic demand during exercise: a noninvasive MRI method of assessment
Richardson, R. S., Haseler, L. J., Nygren, A. T., Bluml, S., & Frank, L. R. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.4.1845 · Cited by 87
Yen, Y., Field, A. S., Martin, E. M., Ari, N., Burdette, J. H., Moody, D. M., & Takahashi, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10140 · Cited by 86
Visual cortex reactivity in sedated children examined with perfusion MRI (FAIR)
Born, A. P., Rostrup, E., Miranda, M. J., Larsson, H. B. W., & Lou, H. C. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00469-1 · Cited by 81
Weber, M., Günther, M., Lichy, M. P., Delorme, S., Bongers, A., Thilmann, C., Essig, M., ZUNA, I., Schad, L. R., Debus, J., et al. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000084890.57197.54 · Cited by 81
Forbes, M. L., Hendrich, K. S., Kochanek, P. M., Williams, D. S., Schiding, J. K., Wisniewski, S. R., Kelsey, S. F., DeKoskydagger, S. T., Graham, S. H., Marion, D. W., et al. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199708000-00005 · Cited by 80
Slice profile effects in adiabatic inversion: Application to multislice perfusion imaging
Frank, L. R., Wong, E. C., & Buxton, R. B. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380409 · Cited by 78
Yang, Y., Gu, H., Zhan, W., Xu, S., Silbersweig, D. A., & Stern, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10196 · Cited by 77
Duhamel, G., de BAZELAIRE, C., & Alsop, D. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10510 · Cited by 72
Zhu, X., Kim, S., Andersen, P., Ogawa, S., Uğgurbil, K., & Chen, W. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400510 · Cited by 71
Ewing, J. R., Wei, L., Knight, R. A., Pawa, S., Nagaraja, T. N., Brusca, T., Divine, G., & Fenstermacher, J. D. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000046147.31247.e8 · Cited by 70
Liu, H., Kochunov, P., Hou, J., Pu, Y., Mahankali, S., Feng, C., Yee, S.-H., Wan, Y., Fox, P. T., & Gao, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0.co;2-e · Cited by 68
Yang, Y., Engelien, W., Pan, H., Xu, S., Silbersweig, D. A., & Stern, E. (2000) · NeuroImage · doi:10.1006/nimg.2000.0625 · Cited by 68
Roberts, D. A., Rizi, R. R., Lenkinski, R. E., & LEIGH, J. S. J. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060217 · Cited by 68
St. Lawrence, K. S., Ye, F. Q., Lewis, B. K., Frank, J. A., & McLaughlin, A. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10502 · Cited by 67
Hendrikse, J., Lu, H., van der Grond, J., van Zijl, P. C. M., & Golay, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10525 · Cited by 67
Self-citationNoninvasive perfusion MRI in Alzheimer's disease: A preliminary report
Sandson, T. A., O'Connor, M., Sperling, R. A., Edelman, R. R., & Warach, S. (1996) · Neurology · doi:10.1212/wnl.47.5.1339 · Cited by 67
Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 T
Lee, S., Silva, A. C., & Kim, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10117 · Cited by 65
Ye, F. Q., Smith, A. M., Yang, Y., Duyn, J. H., Mattay, V. S., Ruttimann, U. E., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · NeuroImage · doi:10.1006/nimg.1997.0282 · Cited by 63
Yongbi, M. N., Yang, Y., Frank, J. A., & Duyn, J. H. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1098::aid-mrm14>3.0.co;2-1 · Cited by 62
McLaughlin, A. C., Ye, F. Q., Pekar, J. J., Santha, A. K. S., & Frank, J. A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370406 · Cited by 62
Pharmacological Applications of Magnetic Resonance Imaging
Salmeron, B. J., MD, Stein, A. E. A., & PhD (2025) · Psychopharmacology Bulletin · doi:10.64719/pb.4234 · Cited by 61
Empirical analyses of null-hypothesis perfusion FMRI data at 1.5 and 4 T
Wang, J., Aguirre, G. K., Kimberg, D. Y., & Detre, J. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00255-6 · Cited by 59
Li, T., Neumann‐Haefelin, T., Chan, B., Kastrup, A., Jonsson, T., Glover, G. H., & Moseley, M. E. (2000) · NeuroImage · doi:10.1006/nimg.2000.0634 · Cited by 57
Quantification of cerebral blood flow by bolus tracking and artery spin tagging methods
Li, T., Chen, Z. G., Østergaard, L., Hindmarsh, T., & Moseley, M. E. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00137-5 · Cited by 55
Lu, H., Golay, X., & van Zijl, P. C. M. (2002) · NeuroImage · doi:10.1006/nimg.2002.1206 · Cited by 54
Self-citationYongbi, M. N., Fera, F. S., Yang, Y., Frank, J. A., & Duyn, J. H. (2002) · Radiology · doi:10.1148/radiol.2222001697 · Cited by 53
Turbo ASL: Arterial spin labeling with higher SNR and temporal resolution
Wong, E. C., Luh, W., & Liu, T. T. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<511::aid-mrm2>3.0.co;2-6 · Cited by 53
High‐sensitivity single‐shot perfusion‐weighted fMRI†
Duyn, J. H., Tan, C. X., van Gelderen, P., & Yongbi, M. N. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1163 · Cited by 52
Schmitt, P., Kotas, M., Tobermann, A., Haase, A., & Flentje, M. P. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00024-0 · Cited by 52
STAR‐HASTE: Perfusion imaging without magnetic susceptibility artifact
Chen, Q., Siewert, B., Bly, B. M., Warach, S., & Edelman, R. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380308 · Cited by 50
Perfusion imaging using FOCI RF pulses
Yongbi, M. N., Branch, C. A., & Helpern, J. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400622 · Cited by 47
Lythgoe, M. F., Thomas, D. L., Calamante, F., Pell, G. S., King, M. D., Busza, A. L., Sotak, C. H., Williams, S. R., Ordidge, R. J., & Gadian, D. G. (2000) · Magnetic Resonance in Medicine · Cited by 47
Ewing, J. R., Cao, Y., & Fenstermacher, J. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1215 · Cited by 46
Perfusion analysis using dynamic arterial spin labeling (DASL)
Barbier, E., Silva, A. C., Kim, H. J., Williams, D. S., & Koretsky, A. P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2<299::aid-mrm13>3.0.co;2-r · Cited by 44
Mapping cortical columnar structures using fMRI
KIM, S., & Duong, T. Q. (2002) · Physiology & Behavior · doi:10.1016/s0031-9384(02)00901-0 · Cited by 43
Preibisch, C., & Haase, A. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1173 · Cited by 43
Lawrence, K. S., Ye, F. Q., Lewis, B. K., Weinberger, D. R., Frank, J. A., & McLaughlin, A. C. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10111 · Cited by 42
FAIR excluding radiation damping (FAIRER)
Zhou, J., Mori, S., & van Zijl, P. C. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400511 · Cited by 42
Functional MRI using steady‐state arterial water labeling
Talagala, S. L., & Noll, D. C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390203 · Cited by 42
Deferoxamine Improves Early Postresuscitation Reperfusion after Prolonged Cardiac Arrest in Rats
Liachenko, S. M., Tang, P. S., & Xu, Y. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000057742.00152.3f · Cited by 41
Ye, F. Q., Smith, A. M., Mattay, V. S., Ruttimann, U. E., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1998) · NeuroImage · doi:10.1006/nimg.1998.0342 · Cited by 38
Noninvasive perfusion imaging of human brain tumors with EPISTAR
Gaa, J., Warach, S. J., Wen, P. Y., Thangaraj, V., Wielopolski, P. A., & Edelman, R. R. (1996) · European Radiology · doi:10.1007/bf00182486 · Cited by 38
A FAIR Study of Motor Cortex Activation under Normo- and Hypercapnia Induced by Breath Challenge
Li, T., Moseley, M. E., & Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1999.0496 · Cited by 37
Toussaint, J., Kwong, K. K., M’Kparu, F., Weisskoff, R. M., LaRaia, P. J., & Kantor, H. L. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.5.2221 · Cited by 34
Myocardial perfusion imaging using a non-contrast agent MR imaging technique
Waller, C., Hiller, K., Voll, S., Haase, A., Ertl, G., & Bauer, W. R. (2001) · International journal of cardiac imaging · doi:10.1023/a:1010603217785 · Cited by 33
Pulsed arterial spin labeling using TurboFLASH with suppression of intravascular signal
Pell, G. S., Lewis, D. P., & Branch, C. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10373 · Cited by 33
Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions
Crelier, G. R., Hoge, R. D., Munger, P., & Pike, G. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18>3.0.co;2-5 · Cited by 33
Magnetic resonance imaging of perfusion in rat cerebral 9L tumor after nicotinamide administration
Brown, S. L., Ewing, J. R., Kolozsvary, A. J. J., Butt, S., Cao, Y., & Kim, J. H. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00422-2 · Cited by 31
Schulte, A., Speck, O., Oesterle, C., & Hennig, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1109 · Cited by 31
Ye, F. Q., Yang, Y., Duyn, J. H., Mattay, V. S., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199908)42:2<404::aid-mrm23>3.0.co;2-0 · Cited by 25
Measurement of local cerebral blood flow and metabolism in man with positron emission tomography.
Raichle, M. E. (1981) · PubMed · Cited by 25
Perfusion-based event-related functional MRI
Liu, H., & Gao, J. (1999) · Magnetic Resonance in Medicine · Cited by 23
Lai, S., Wang, J., & Jahng, G. (2001) · NMR in Biomedicine · doi:10.1002/nbm.738 · Cited by 22
Doraiswamy, P. M., MacFall, J. R., Krishnan, K. R. R., O’Connor, C. M., Wan, X., Benaur, M., Lewandowski, M., & Fortner, M. (1999) · American Journal of Psychiatry · doi:10.1176/ajp.156.10.1641 · Cited by 21
Yamamoto, T., Pipo, J. R., Akaboshi, S., & Narai, S. (2001) · Brain and Development · doi:10.1016/s0387-7604(01)00177-2 · Cited by 19
Pell, G. S., King, M. D., Proctor, E., Thomas, D. L., Lythgoe, M. F., Gadian, D. G., & Ordidge, R. J. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000063990.19746.58 · Cited by 18
A strategy to optimize the signal-to-noise ratio in one-coil arterial spin tagging perfusion imaging
Lei, H. C., & Peeling, J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199903)41:3<563::aid-mrm20>3.0.co;2-6 · Cited by 15
BASE imaging: A new spin labeling technique for measuring absolute perfusion changes
Schwarzbauer, C., & Heinke, W. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390508 · Cited by 15
Breast tissue differentiation using arterial spin tagging
Zhu, D. C., & Buonocore, M. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10616 · Cited by 15
Skeletal muscle perfusion measurements using adiabatic inversion of arterial water
Marro, K. I., & Kushmerick, M. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380108 · Cited by 13
Blamire, A. M., & Styles, P. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200005)43:5<701::aid-mrm12>3.0.co;2-y · Cited by 12
Kao, Y., Wan, X., & MacFall, J. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390422 · Cited by 12
Wang, Z., Gu, H., Silbersweig, D., et al. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00525-8 · Cited by 11
Robertson, C., Hendrich, K. S., Kochanek, P. M., Jackson, E. K., Melick, J. A., Graham, S. H., Marion, D. W., Williams, D. S., & Ho, C. (2000) · Springer eBooks · doi:10.1007/978-3-7091-6346-7_37 · Cited by 9
Effect of Gossypol on Cultured TM3 Leydig and TM4 Sertoli Cells: 31P and 23Na NMR Study
Hansen, L. L., & Jaroszewski, J. W. (1996) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199604)9:2<79::aid-nbm399>3.0.co;2-4 · Cited by 9
Zhang, W. G. (1995) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1995.1073 · Cited by 8
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Wheeler-Kingshott (2000) · doi:10.1002/1522-2594(200011)44:5
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Self-citation
Metadata
- Authors
- Golay, X., Hendrikse, J., & Lim, T. C. C.
- Venue
- Topics in Magnetic Resonance Imaging
- Published
- 2004-02
- Volume
- 15
- Issue
- 1
- Pages
- 10-27
- ISSN
- 0899-3459 (ISSN-L)
- OpenAlex
- W2076212130
- Cited by
- 256
- References
- 165
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.