Adverse Tissue Reactions to Bioabsorbable Fixation Devices
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Among 2528 patients operated on using pins, rods, bolts, and screws made of polyglycolic acid or polylactic acid, 108 (4.3%) were affected by a clinically significant local inflammatory, sterile tissue reaction. The three most common indications for the use of these fixation devices were a displaced malleolar fracture, a chevron osteotomy for hallux valgus, and a displaced fracture of the radial head. In 107 patients, the reaction was elicited by a polyglycolic acid implant, and in one patient by a polylactic acid implant. The incidences were 5.3% (107 of 2037) and 0.2% (one of 491), respectively. The adverse tissue responses to polyglycolic acid were seen 11 weeks after the operation, on average, whereas the reaction to polylactic acid occurred 4.3 years after fixation of an ankle fracture. The mild reactions consisted of a painful erythematous papule of a few weeks' duration. Those of medium severity had a sinus that discharged remnants of the implant for up to 6 months. In the patients affected by severe reactions, extensive osteolytic lesions developed at the implant tracks. The histopathologic picture was that of a nonspecific foreign body reaction. In four patients with vigorous reactions, an arthrodesis of the wrist or ankle later was necessary because of severe osteoarthritis. Several markers of increased risk of the occurrence of a foreign body reaction were found. These included a poorly vascularized bone section such as scaphoid, use of a quinone dye as an additive in the polymer, and an implant geometry with large surface area (screw versus pin or rod). For polyglycolic acid implants, the risk of an adverse tissue response in a given clinical situation can be estimated from the findings of this study. For slow degrading polymers like polylactic acid, however, the ultimate biocompatibility still is unsettled, and additional clinical research with long followup is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable poly(lactic acid) polymers
Kulkarni, R. K., Moore, E. G., Hegyeli, A. F., & Leonard, F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050305 · Cited by 799
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
Bostman, O., Hirvensalo, E., Makinen, J., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2199452 · Cited by 526
Biodegradable bone repair materials. Synthetic polymers and ceramics.
Hollinger, J. O., & Battistone, G. C. (1986) · PubMed · Cited by 486
Absorbable implants for the fixation of fractures.
Böstman, O. M. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173010-00022 · Cited by 459
Self-citationBiodegradable Bone Repair Materials: Synthetic Polymers and Ceramics
HOLLINGER, J. O., & BATTISTONE, G. C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198606000-00046 · Cited by 381
Osteolytic changes accompanying degradation of absorbable fracture fixation implants
Bostman, O. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.1649195 · Cited by 294
BIODEGRADABLE IMPLANTS IN FRACTURE FIXATION: EARLY RESULTS OF TREATMENT OF FRACTURES OF THE ANKLE
Rokkanen, P., Vainionpää, S., Törmälä, P., Kilpikari, J., Böstman, O., Vihtonen, K., Laiho, J., & Tamminmäki, M. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91847-1 · Cited by 293
Self-citationFixation with bioabsorbable screws for the treatment of fractures of the ankle.
Bucholz, R. W., Henry, S., & Henley, M. B. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199403000-00001 · Cited by 271
Weiler, A., Helling, H. J., Kirch, U., Zirbes, T. K., & Rehm, K. E. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b3.0780369 · Cited by 187
BÖSTMAN, O. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199205000-00031 · Cited by 185
Self-citationAnkle Fractures Treated Using Biodegradable Internal Fixation
BÖSTMAN, O., HIRENSALO, E., VAINIONPÄÄ, S., MÄKELÄ, A., VIHTONEN, K., TÖRMÄLÄ, P., & ROKKANEN, P. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198901000-00028 · Cited by 182
Self-citationPreliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178
Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies
Pihlajamaki, H., Bostman, O., Hirvensalo, E., Tormala, P., & Rokkanen, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b6.1447246 · Cited by 167
Absorbable polyglycolide devices in trauma and bone surgery
Ashammakhi, N., & Rokkanen, P. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00107-x · Cited by 166
Biodegradable internal fixation for malleolar fractures. A prospective randomised trial
Bostman, O., Vainionpaa, S., Hirvensalo, E., Makela, A., Vihtonen, K., Tormala, P., & Rokkanen, P. (1987) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.69b4.3611169 · Cited by 161
Immune response to polyglycolic acid implants
Santavirta, S., Konttinen, Y., Saito, T., Gronblad, M., Partio, E., Kemppinen, P., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2166048 · Cited by 160
Böstman, O. M. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b2.0800333 · Cited by 159
Self-citationWeiler, A., Helling, H.-J., Kirch, U., et al. (1996) · PubMed · Cited by 156
Biodegradable implants in traumatology: a review on the state-of-the-art
Hofmann, G. O. (1995) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00443385 · Cited by 155
Biodegradable Pin Fixation of Osteochondral Fragments of the Knee
Matsusue, Y., Nakamura, T., Suzuki, S., & Iwasaki, R. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199601000-00021 · Cited by 155
Late Foreign-Body Reaction to an Intraosseous Bioabsorbable Polylactic Acid Screw. A Case Report*
Böstman, O. M., & PIHLAJAMÄKI, H. K. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199812000-00010 · Cited by 153
Self-citationSevere aseptic synovitis of the knee after biodegradable internal fixation
Fridén, T., & Rydholm, U. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154859 · Cited by 132
Adverse reactions to an absorbable shoulder fixation device
Edwards, D. J., Hoy, G., Saies, A. D., & Hayes, M. G. (1994) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80040-2 · Cited by 124
Majola, A., Vainionp��, S., Rokkanen, P., Mikkola, H., & T�rm�l�, P. (1992) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00702943 · Cited by 121
Böstman, O., Päivärinta, U., Partio, E., Vasenius, J., Manninen, M., & Rokkanen, P. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274070-00008 · Cited by 118
Self-citationFracture fixation with biodegradable rods Forty-one cases of severe ankle fractures
Hirvensalo, E. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909150131 · Cited by 112
Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial
Casteleyn, P., Handelberg, F., & Haentjens, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b6.1332974 · Cited by 108
Metallic or Absorbable Fracture Fixation Devices: A Cost Minimization Analysis
B�stman, O. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199608000-00029 · Cited by 103
Self-citationBiodegradable pin fixation of elbow fractures in children. A randomised trial
Hope, P., Williamson, D., Coates, C., & Cole, W. (1991) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.73b6.1659570 · Cited by 88
Osteolysis after biodegradable pin fixation of fractures in children
Fraser, R., & Cole, W. (1992) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.74b6.1332975 · Cited by 75
Local foreign-body reactions to biodegradable implants
Hoffmann, R. F. G., Weiler, A., Helling, H. J., Krettek, C., & Rehm, K. E. (1997) · Der Unfallchirurg · doi:10.1007/s001130050172 · Cited by 71
Polyglycolide Bioabsorbable Screws in the Treatment of Ankle Fractures
Hovis, W. D., & Bucholz, R. W. (1997) · Foot & Ankle International · doi:10.1177/107110079701800303 · Cited by 66
Absorbable polyglycolide pins in internal fixation of fractures in children.
Böstman, O. M., Mäkelä, E. A., Södergård, J., Hirvensalo, E., Törmälä, P., & Rokkanen, P. (1993) · PubMed · Cited by 59
Self-citationInhibition of the tissue reaction to a biodegradable biomaterial by monoclonal antibodies to IFN-?
Khouw, I. M. S. L., van Wachem, P. B., de Leij, L. F. M. H., & van Luyn, M. J. A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199808)41:2<202::aid-jbm4>3.0.co;2-m · Cited by 53
Biofix fixation techniques and results in foot surgery
Burns, A. E. (1995) · The Journal of Foot & Ankle Surgery · doi:10.1016/s1067-2516(09)80060-4 · Cited by 38
Totally Bioresorbable Composites Systems for Internal Fixation of Bone Fractures
Vert, M., Christel, P., Garreau, H., Audion, M., Chanavaz, M., & Chabot, F. (1986) · Springer eBooks · doi:10.1007/978-1-4613-1809-5_21 · Cited by 32
PIHLAJAMÄKI, H. K., Böstman, O. M., & Rokkanen, P. (1994) · International Orthopaedics · doi:10.1007/bf02484413 · Cited by 28
Self-citationBIODEGRADABLE PIN FIXATION OF ELBOW FRACTURES IN CHILDREN
Hope, P., Williamson, D., & Coates, C. J. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199205000-00068 · Cited by 27
Cited by
da Silva, D., Kaduri, M., Poley, M., Adir, O., Krinsky, N., Shainsky-Roitman, J., & Schroeder, A. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.01.010 · Cited by 863
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Yoshizawa, S., Brown, A., Barchowsky, A., & Sfeir, C. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.002 · Cited by 577
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
Metadata
- Authors
- B??stman, O. M., & Pihlajam??ki, H. K.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2000-02
- Volume
- 371
- Issue
- 371
- Pages
- 216-227
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W127024613
- Cited by
- 476
- References
- 40
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.