In Vivo Three-Dimensional Knee Kinematics Using a Biplanar Image-Matching Technique
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
A biplanar image-matching technique was developed and applied to a study of normal knee kinematics in vivo under weightbearing conditions. Three-dimensional knee models of six volunteers were constructed using computed tomography. Projection images of the models were fitted onto anteroposterior and lateral radiographs of the knees at hyperextension and every 15 degrees from 0 degrees to 120 degrees flexion. Knee motion was reconstructed on the computer. The femur showed a medial pivoting motion relative to the tibia during knee flexion, and the average range of external rotation associated with flexion was 29.1 degrees . The center of the medial femoral condyle translated 3.8 mm anteriorly, whereas the center of the lateral femoral condyle translated 17.8 mm posteriorly. This rotational motion, with a medially offset center, could be interpreted as a screw home motion of the knee around the tibial knee axis and a posterior femoral rollback in the sagittal plane. However, the motion of the contact point differed from that of the center of the femoral condyle when the knee flexion angle was less than 30 degrees. Within this range, medial and lateral contact points translated posteriorly, and a posterior femoral rollback occurred. This biplanar image-matching technique is useful for investigating knee kinematics in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
Banks, S. A., & Hodge, W. A. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.495283 · Cited by 596
The Axes of Rotation of the Knee
HOLLISTER, A. M., JATANA, S., SINGH, A. K., SULLIVAN, W. W., & LUPICHUK, A. G. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199305000-00033 · Cited by 502
The Transepicondylar Axis Approximates the Optimal Flexion Axis of the Knee
Churchill, D. L., Incavo, S. J., Johnson, C. C., & Beynnon, B. D. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199811000-00016 · Cited by 497
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties
Banks, S. A., Markovich, G. D., & Hodge, W. A. (1997) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(97)90026-7 · Cited by 321
Geometry and motion of the knee for implant and orthotic design
Kurosawa, H., Walker, P. S., Abe, S., Garg, A., & Hunter, T. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90663-3 · Cited by 292
Tibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers
Reinschmidt, C., van den Bogert, A. J., Lundberg, A., Nigg, B. M., Murphy, N., Stacoff, A., & Stano, A. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)01110-7 · Cited by 257
Interaction between intrinsic knee mechanics and the knee extensor mechanism
Draganich, L. F., Andriacchi, T. P., & Andersson, G. B. J. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050409 · Cited by 182
A Correlative Study of the Geometry and Anatomy of the Distal Femur
ELIAS, S. G., FREEMAN, M. A. R., & GOKCAY, E. I. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199011000-00018 · Cited by 173
Cited by
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
Johal, P., Williams, A., Wragg, P., Hunt, D., & Gedroyc, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.008 · Cited by 360
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
THREE-DIMENSIONAL MECHANICS, KINEMATICS, AND MORPHOLOGY OF THE KNEE VIEWED IN VIRTUAL REALITY
ECKHOFF, D. G., BACH, J. M., SPITZER, V. M., REINIG, K. D., BAGUR, M. M., BALDINI, T. H., & FLANNERY, N. M. P. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200511002-00009 · Cited by 293
Li, G., Van de Velde, S. K., & Bingham, J. T. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.01.034 · Cited by 246
The Functional Flexion-Extension Axis of the Knee Corresponds to the Surgical Epicondylar Axis
Asano, T., Akagi, M., & Nakamura, T. (2005) · The Journal of Arthroplasty · doi:10.1016/j.arth.2004.08.005 · Cited by 223
Self-citationFeasibility of Using Orthogonal Fluoroscopic Images to Measure In Vivo Joint Kinematics
Li, Wuerz, & DeFrate, L. E. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1691448 · Cited by 192
In vivo tibiofemoral contact analysis using 3D MRI-based knee models
DeFrate, L. E., Sun, H., Gill, T. J., Rubash, H. E., & Li, G. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.01.012 · Cited by 188
Dynamic activity dependence of in vivo normal knee kinematics
Moro‐oka, T., Hamai, S., Miura, H., Shimoto, T., Higaki, H., Fregly, B. J., Iwamoto, Y., & Banks, S. A. (2008) · Journal of Orthopaedic Research · doi:10.1002/jor.20488 · Cited by 188
“Asano et al.1 reported a medial pivot motion pattern during static weight bearing from 08 to 908.”
BackgroundMethodLi, G., DeFrate, L. E., Sun, H., & Gill, T. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262175 · Cited by 182
“manually manipulated in 6 degrees of freedom until its projection matched that of the 2 orthogonal radiograph images.(3,27) Our technique employing the orthogonal images and computer models to measure knee kinematics has been described in detail in our previous publication.”
MethodLi, G., DeFrate, L. E., Park, S. E., Gill, T. J., & Rubash, H. E. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504265577 · Cited by 171
“In most of these studies, CT image–based knee models were used to reproduce in vivo knee positions.(2,8,15,17) Cine MR image techniques have also been extensively used to measure in vivo knee kinematics.”
BackgroundMethodResultInfluentialScrew-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis
Kim, H. Y., Kim, K. J., Yang, D. S., Jeung, S. W., Choi, H. G., & Choy, W. S. (2015) · Clinics in Orthopedic Surgery · doi:10.4055/cios.2015.7.3.303 · Cited by 116
Gamada, K. (2014) · International Journal of Physical Medicine & Rehabilitation · doi:10.4172/2329-9096.1000246 · Cited by 12
“During squatting, the femoral joint surface should glide anteriorly on the tibial joint surface due to the dominance in gliding over rolling, and the lateral femoral condyle moves posteriorly over the tibial plateau (rollback phenomenon) [222-224].”
Metadata
- Authors
- Asano, T., Akagi, M., Tanaka, K., Tamura, J., & Nakamura, T.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2001-07
- Volume
- 388
- Issue
- 388
- Pages
- 157-166
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2060436321
- Cited by
- 224
- References
- 16
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.