MR Diffusion Imaging of the Human Brain
The DOI matches its Crossref record.
Abstract
Magnetic resonance diffusion imaging reflects the water mobility at each point in a tomographic image. We have studied brain water diffusion in 18 normal volunteers to identify the different factors that can influence diffusion measurements in vivo. Our results show that both the measurement accuracy and the measured diffusion coefficient strongly depend on the experimental parameters, in particular, echo and diffusion time, cardiac gating, and diffusion encoding gradient direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
A review of MRI findings in schizophrenia
Shenton, M. E., Dickey, C. C., Frumin, M., & McCarley, R. W. (2001) · Schizophrenia Research · doi:10.1016/s0920-9964(01)00163-3 · Cited by 2,346
“It has also been used to evaluate brain tumors (e.g. Le Bihan et al., 1986; Hajnal et al., 1991) and normal and abnormal white matter via diffusion anisotropy (Chien et al., 1990; Doran et al., 1990; Douek et al., 1991; Le Bihan, 1995; Peled et al., 1998).”
MethodOptimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Sugahara, T., Korogi, Y., Kochi, M., Ikushima, I., Shigematu, Y., Hirai, T., Okuda, T., Liang, L., Ge, Y., Komohara, Y., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199901)9:1<53::aid-jmri7>3.0.co;2-2 · Cited by 1,163
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Self-citationHüppi, P. S., Maier, S. E., Peled, S., Zientara, G. P., Barnes, P. D., Jolesz, F. A., & Volpe, J. J. (1998) · Pediatric Research · doi:10.1203/00006450-199810000-00019 · Cited by 721
A simplified method to measure the diffusion tensor from seven MR images
Basser, P. J., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390610 · Cited by 583
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Greitz, D., Wirestam, R., Franck, A., Nordell, B., Thomsen, C., & St�hlberg, F. (1992) · Neuroradiology · doi:10.1007/bf00596493 · Cited by 416
Makris, N., Worth, A. J., Papadimitriou, G. M., Stakes, J. W., Caviness, V. S., Kennedy, D. N., Pandya, D. N., Kaplan, E., Sorensen, A. G., Wu, O., et al. (1997) · Annals of Neurology · doi:10.1002/ana.410420617 · Cited by 380
Self-citationMR imaging of high-grade cerebral gliomas: value of diffusion-weighted echoplanar pulse sequences.
Tien, R. D., Felsberg, G. J., Friedman, H., Brown, M., & MacFall, J. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.162.3.8109520 · Cited by 368
Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
Jezzard, P., Barnett, A. S., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390518 · Cited by 352
MR diffusion imaging of human intracranial tumours
Krabbe, K., Gideon, P., Wagn, P., Hansen, U., Thomsen, C., & Madsen, F. (1997) · Neuroradiology · doi:10.1007/s002340050450 · Cited by 330
Shimony, J. S., McKinstry, R. C., Akbudak, E., Aronovitz, J. A., Snyder, A. Z., Lori, N. F., Cull, T. S., & Conturo, T. E. (1999) · Radiology · doi:10.1148/radiology.212.3.r99au51770 · Cited by 315
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Sorensen, A. G., Wu, O., Copen, W. A., Davis, T. L., Gonzalez, R. G., Koroshetz, W. J., Reese, T. G., Rosen, B. R., Wedeen, V. J., & Weisskoff, R. M. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se24785 · Cited by 300
Self-citationImaging myocardial fiber architecture in vivo with magnetic resonance
Reese, T. G., Weisskoff, R. M., Smith, R. N., Rosen, B. R., Dinsmore, R. E., & Wedeen, V. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340603 · Cited by 292
Self-citationWater diffusion and exchange as they influence contrast enhancement
Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070114 · Cited by 270
Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo
Tofts, P. S., Lloyd, D., Clark, C. A., Barker, G. J., Parker, G. J. M., McConville, P., Baldock, C., & Pope, J. M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<368::aid-mrm8>3.0.co;2-b · Cited by 265
MR diffusion imaging of cerebral infarction in humans.
(1992) · PubMed Central · Cited by 258
MR Diffusion Tensor Imaging: A Window into White Matter Integrity of the Working Brain
Chanraud, S., Zahr, N., Sullivan, E. V., & Pfefferbaum, A. (2010) · Neuropsychology Review · doi:10.1007/s11065-010-9129-7 · Cited by 252
Alcohol's Effects on the Brain: Neuroimaging Results in Humans and Animal Models
Zahr, N. (2017) · Alcohol Research: Current Reviews · doi:10.35946/arcr.v38.2.04 · Cited by 229
“A number of sources provide extensive descriptions of the principles of DTI (Basser and Jones 2002; Chien et al. 1990; Gerig et al. 2005; Jones 2005; LeBihan 2001, 2003; Pierpaoli et al. 1996; Poupon et al. 1999; Sullivan and Pfefferbaum 2011).”
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Diffusion MRI · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 217
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
Christiansen, P., Gideon, P., Thomsen, C., Stubgaard, M., Henriksen, O., & Larsson, H. B. W. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1993.tb04100.x · Cited by 187
In vivo magnetic resonance diffusion measurement in the brain of patients with multiple sclerosis
Larsson, H. B. W., Thomsen, C., Frederiksen, J., Stubgaard, M., & Henriksen, O. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90367-9 · Cited by 181
Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain
Xing, D., Papadakis, N. G., Huang, C. L.-H., Lee, V. M., Adrian Carpenter, T., & Hall, L. D. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00037-4 · Cited by 181
Diffusion-Weighted MRI in Acute Subcortical Infarction
Singer, M. B., Chong, J., Lu, D., Schonewille, W. J., Tuhrim, S., & Atlas, S. W. (1998) · Stroke · doi:10.1161/01.str.29.1.133 · Cited by 179
Butts, K., Pauly, J., De Crespigny, A., & Moseley, M. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380510 · Cited by 160
(2003) · PubMed Central · Cited by 76
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2014) · Diffusion MRI · doi:10.1016/b978-0-12-396460-1.00008-1 · Cited by 66
40 Years of diffusion MRI in the brain: From history to emerging frontiers
Le Bihan, D. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1365 · Cited by 2
Metadata
- Authors
- Chien, D., Buxton, R. B., Kwong, K. K., Brady, T. J., & Rosen, B. R.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1990-07
- Volume
- 14
- Issue
- 4
- Pages
- 514-520
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1991677258
- Cited by
- 154
- References
- 0
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.