The ECAT EXACT HR: Performance of a New High Resolution Positron Scanner
The DOI matches its Crossref record.
Abstract
OBJECTIVE: The ECAT EXACT HR is a newly designed CTI-Siemens PET scanner with high spatial resolution. Its physical performance with respect to resolution, count rate efficiency, and scatter was investigated and evaluated with phantom studies. MATERIALS AND METHODS: The new tomograph consists of three rings of 112 BGO block detectors (50 mm x 23 mm x 30 mm deep) each, covering an axial field of view of 15 cm with a patient port of 56 cm diameter. Each block is sawed into an 8 x 7 matrix giving 24 detector rings with 784 crystals each. RESULTS: Total sensitivity for a 20 cm cylinder phantom is 177 kcps/microCi/ml in two-dimensional (2D) mode and increases to 1.46 Mcps/microCi/ml in 3D mode. Count rate performance was investigated for different low energy discriminator thresholds. Smaller detector blocks improve noise equivalent counts by approximately 50% compared with the EXACT system both in 2D and in 3D mode. Scatter fractions vary in 2D from 0.09 to 0.13 for energy thresholds from 450 to 250 keV for line sources in a 20 cm diameter phantom. In 3D mode an increase of scatter by a factor of 3 is observed. Transaxial spatial resolution varies from 3.6 mm full width at half-maximal (FWHM) at the center to 4.5 mm FWHM tangentially and 7.4 mm FWHM radially at R = 20 cm. Average axial resolution changes from 4.0 mm FWHM at center to 6.7 mm FWHM at R = 20 cm. CONCLUSION: Due to its special properties, the EXACT HR can be equally applied to routine clinical brain and whole-body imaging and to noninvasive experimental studies of regional tracer concentrations in medium-sized animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190
Importance of Hemodynamic Factors in the Prognosis of Symptomatic Carotid Occlusion
Grubb, Jr. (1998) · JAMA · doi:10.1001/jama.280.12.1055 · Cited by 807
Cerebral Representation of One’s Own Past: Neural Networks Involved in Autobiographical Memory
Fink, G. R., Markowitsch, H. J., Reinkemeier, M., Bruckbauer, T., Kessler, J., & Heiss, W.-D. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-13-04275.1996 · Cited by 803
“The PET measurements were carried out using a CTI ECAT Exact HR PET scanner (CTI, Knoxville, TN) with a total axial field of view of 15 cm covering the whole brain (Wienhard et al., 1994).”
MethodSelf-citationExact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Self-citationOncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose
Rigo, P., Paulus, P., Kaschten, B. J., Hustinx, R., Bury, T., Jerusalem, G., Benoit, T., & Foidart-Willems, J. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249629 · Cited by 501
Weber, W. A., Petersen, V., Schmidt, B., Tyndale-Hines, L., Link, T., Peschel, C., & Schwaiger, M. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.12.004 · Cited by 493
Differential capacity of left and right hemispheric areas for compensation of poststroke aphasia
Heiss, W.-D., Kessler, J., Thiel, A., Ghaemi, M., & Karbe, H. (1999) · Annals of Neurology · doi:10.1002/1531-8249(199904)45:4<430::aid-ana3>3.0.co;2-p · Cited by 437
Self-citationPesenti, M., Thioux, M., Seron, X., & Volder, A. D. (2000) · Journal of Cognitive Neuroscience · doi:10.1162/089892900562273 · Cited by 429
A gradient-based method for segmenting FDG-PET images: methodology and validation
Geets, X., Lee, J. A., Bol, A., Lonneux, M., & Grégoire, V. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0363-4 · Cited by 419
Pain-related cerebral activation is altered by a distracting cognitive task
Petrovic, P., Petersson, K. M., Ghatan, P. H., Stone-Elander, S., & Ingvar, M. (2000) · Pain · doi:10.1016/s0304-3959(99)00232-8 · Cited by 419
Castro-Caldas, A. (1998) · Brain · doi:10.1093/brain/121.6.1053 · Cited by 395
“Repeated measurements of regional cerebral blood flow (rCBF) were made with a 3D Ecat Exact HR PET scanner (Wienhard et al., 1994) and bolus injections of [ 15 O]butanol (Berridge et al., 1990).”
MethodDementia in Parkinson disease: Functional imaging of cholinergic and dopaminergic pathways
Hilker, R., Thomas, A. V., Klein, J. C., Weisenbach, S., Kalbe, E., Burghaus, L., Jacobs, A. H., Herholz, K., & Heiss, W. D. (2005) · Neurology · doi:10.1212/01.wnl.0000191154.78131.f6 · Cited by 384
Self-citationHypoperfusion without Ischemia Surrounding Acute Intracerebral Hemorrhage
Zazulia, A. R., Diringer, M. N., Videen, T. O., Adams, R. E., Yundt, K., Aiyagari, V., Grubb, R. L., & Powers, W. J. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200107000-00005 · Cited by 367
Mintun, M. A., Lundstrom, B. N., Snyder, A. Z., Vlassenko, A. G., Shulman, G. L., & Raichle, M. E. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.111164398 · Cited by 361
Autoregulation of cerebral blood flow surrounding acute (6 to 22 hours) intracerebral hemorrhage
Powers, W. J., Zazulia, A. R., Videen, T. O., Adams, R. E., Yundt, K. D., Aiyagari, V., Grubb, R. L., & Diringer, M. N. (2001) · Neurology · doi:10.1212/wnl.57.1.18 · Cited by 337
Nakamura, K. (2000) · Brain · doi:10.1093/brain/123.9.1903 · Cited by 324
Winhuisen, L., Thiel, A., Schumacher, B., Kessler, J., Rudolf, J., Haupt, W. F., & Heiss, W. D. (2005) · Stroke · doi:10.1161/01.str.0000174487.81126.ef · Cited by 311
Self-citationHilker, R., Schweitzer, K., Coburger, S., Ghaemi, M., Weisenbach, S., Jacobs, A. H., Rudolf, J., Herholz, K., & Heiss, W.-D. (2005) · Archives of Neurology · doi:10.1001/archneur.62.3.378 · Cited by 293
Self-citationDelineation of Brain Tumor Extent with [11C]l-Methionine Positron Emission Tomography
Kracht, L. W., Miletic, H., Busch, S., Jacobs, A. H., Voges, J., Hoevels, M., Klein, J. C., Herholz, K., & Heiss, W.-D. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0262 · Cited by 292
Self-citationBrain Plasticity in Poststroke Aphasia: What Is the Contribution of the Right Hemisphere?
Karbe, H., Thiel, A., Weber-Luxenburger, G., Herholz, K., Kessler, J., & Heiss, W.-D. (1998) · Brain and Language · doi:10.1006/brln.1998.1961 · Cited by 262
Self-citationActivation of the Right Inferior Frontal Cortex During Assessment of Facial Emotion
Nakamura, K., Kawashima, R., Ito, K., Sugiura, M., Kato, T., Nakamura, A., Hatano, K., Nagumo, S., Kubota, K., Fukuda, H., et al. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.3.1610 · Cited by 259
The role of the striatal dopamine transporter in cognitive aging
Erixon-Lindroth, N., Farde, L., Robins Wahlin, T.-B., Sovago, J., Halldin, C., & Bäckman, L. (2005) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2004.09.005 · Cited by 252
Support for dopaminergic hypoactivity in restless legs syndrome: a PET study on D2-receptor binding
Cervenka, S. (2006) · Brain · doi:10.1093/brain/awl163 · Cited by 252
Nyberg, S., Eriksson, B., Oxenstierna, G., Halldin, C., & Farde, L. (1999) · American Journal of Psychiatry · doi:10.1176/ajp.156.6.869 · Cited by 251
Thiel, A., Herholz, K., Koyuncu, A., Ghaemi, M., Kracht, L. W., Habedank, B., & Heiss, W. (2001) · Annals of Neurology · doi:10.1002/ana.1253 · Cited by 251
Self-citationThe Serotonin System and Spiritual Experiences
Borg, J., Andrée, B., Soderstrom, H., & Farde, L. (2003) · American Journal of Psychiatry · doi:10.1176/appi.ajp.160.11.1965 · Cited by 243
Hilker, R., Klein, C., Ghaemi, M., Kis, B., Strotmann, T., Ozelius, L. J., Lenz, O., Vieregge, P., Herholz, K., Heiss, W., et al. (2001) · Annals of Neurology · doi:10.1002/ana.74 · Cited by 243
“5 mm) in parallel with the canthomeatal line.(17) Images were reconstructed on a 128 3 128 matrix with 2.”
MethodSelf-citationJamar, F., Barone, R., Mathieu, I., Walrand, S., Labar, D., Carlier, P., Camps, J., Schran, H., Chen, T., Smith, M. C., et al. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1117-1 · Cited by 240
“) [23].”
Jucaite, A., Fernell, E., Halldin, C., Forssberg, H., & Farde, L. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2004.11.009 · Cited by 236
Diringer, M. N., Videen, T. O., Yundt, K., Zazulia, A. R., Aiyagari, V., Dacey, R. G., Grubb, R. L., & Powers, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.96.1.0103 · Cited by 232
Jovanovic, H., Lundberg, J., Karlsson, P., Cerin, Å., Saijo, T., Varrone, A., Halldin, C., & Nordström, A.-L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.016 · Cited by 231
“The PET images were acquired using an ECAT Exact HR 47 scanner (CTI/Siemens, Knoxville, TN) run in 3D mode (Wienhard et al., 1994).”
Heiss, W.-D., Graf, R., Wienhard, K., Löttgen, J., Saito, R., Fujita, T., Rosner, G., & Wagner, R. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.120 · Cited by 230
Self-citationLatest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 223
“The DOI is of particular importance for high-resolution PET scanners with a small-diameter bore, such as dedicated brain scanners or animal PET systems (11,27,39).”
BackgroundSaxena, S., Brody, A. L., Ho, M. L., Alborzian, S., Ho, M. K., Maidment, K. M., Huang, S.-C., Wu, H.-M., Au, S. C., & Baxter, L. R. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(01)01123-4 · Cited by 209
Backman, L. (1997) · Brain · doi:10.1093/brain/120.12.2207 · Cited by 210
“…were performed using an MR Signa Advantage System (General Electric, Signa 1.5 T) at the Karolinska Hospital, providing 124 contiguous slices of the entire brain with a resolution in the axial plane of 1.5 mm. PET studies were performed on a Siemens ECAT Exact HR 47 (Wienhard et al., 1994).”
InfluentialCortical and subcortical blood flow effects of subthalamic nucleus stimulation in PD
Hershey, T., Revilla, F. J., Wernle, A. R., McGee-Minnich, L., Antenor, J. V., Videen, T. O., Dowling, J. L., Mink, J. W., & Perlmutter, J. S. (2003) · Neurology · doi:10.1212/01.wnl.0000083991.81859.73 · Cited by 204
Heiss, W.-D., Grond, M., Thiel, A., von Stockhausen, H.-M., Rudolf, J., Ghaemi, M., Löttgen, J., Stenzel, C., & Pawlik, G. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199812000-00004 · Cited by 192
Self-citationHeiss, W.-D., Kracht, L. W., Thiel, A., Grond, M., & Pawlik, G. (2001) · Brain · doi:10.1093/brain/124.1.20 · Cited by 192
“PET studies were performed in a resting state on an ECAT EXACT HR scanner (Siemens/ CTI, Knoxville, Tenn., USA) in two- or three-dimensional data acquisition mode providing 47 contiguous 3-mm slices at 5 mm full-width, half-maximum, in-plane reconstructed resolution (Wienhard et al., 1994).”
Self-citationBentourkia, M., Bol, A., Ivanoiu, A., Labar, D., Sibomana, M., Coppens, A., Michel, C., Cosnard, G., & De Volder, A. G. (2000) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(00)00396-8 · Cited by 189
“125 mm [13].”
Self-citationReactivation of Motor Brain Areas during Explicit Memory for Actions
Nyberg, L., Petersson, K. M., Nilsson, L.-G., Sandblom, J., Åberg, C., & Ingvar, M. (2001) · NeuroImage · doi:10.1006/nimg.2001.0801 · Cited by 189
From the left to the right: How the brain compensates progressive loss of language function
Thiel, A., Habedank, B., Herholz, K., Kessler, J., Winhuisen, L., Haupt, W. F., & Heiss, W.-D. (2006) · Brain and Language · doi:10.1016/j.bandl.2006.01.007 · Cited by 184
Self-citationEffects of Long-term Smoking on Myocardial Blood Flow, Coronary Vasomotion, and Vasodilator Capacity
Campisi, R., Czernin, J., Schöder, H., Sayre, J. W., Marengo, F. D., Phelps, M. E., & Schelbert, H. R. (1998) · Circulation · doi:10.1161/01.cir.98.2.119 · Cited by 181
Iida, A., Okazawa, H., Hayashida, K., Tsuyuguchi, N., Ishii, K., Kuwabara, Y., Senda, M., Ito, H., Kanno, I., Kato, C., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1430-8 · Cited by 179
“[35]; b Iida et al.”
Variability in D2‐dopamine receptor density and affinity: A PET study with [11C]raclopride in man
Farde, L., Hall, H., Pauli, S., & Halldin, C. (1995) · Synapse · doi:10.1002/syn.890200303 · Cited by 175
Blood flow responses to deep brain stimulation of thalamus
Perlmutter, J. S., Mink, J. W., Bastian, A. J., Zackowski, K., Hershey, T., Miyawaki, E., Koller, W., & Videen, T. O. (2002) · Neurology · doi:10.1212/wnl.58.9.1388 · Cited by 175
Diringer, M. N., Yundt, K., Videen, T. O., Adams, R. E., Zazulia, A. R., Deibert, E., Aiyagari, V., Dacey, R. G., Grubb, R. L., & Powers, W. J. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.92.1.0007 · Cited by 175
Bakshi, R., Miletich, R. S., Kinkel, P. R., Emmet, M. L., & Kinkel, W. R. (1998) · Journal of Neuroimaging · doi:10.1111/jon199884228 · Cited by 175
Quantification of [11C]FLB 457 Binding to Extrastriatal Dopamine Receptors in the Human Brain
Olsson, H., Halldin, C., Swahn, C.-G., & Farde, L. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199910000-00013 · Cited by 174
Kessler, J., Thiel, A., Karbe, H., & Heiss, W. D. (2000) · Stroke · doi:10.1161/01.str.31.9.2112 · Cited by 174
Self-citationHilker, R. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.057893 · Cited by 173
Right-lateralised central processing for pain of nitroglycer-induced cluster headache
Hsieh, J.-C., Hannerz, J., & Ingvar, M. (1996) · Pain · doi:10.1016/0304-3959(96)03066-7 · Cited by 173
Fast and robust registration of PET and MR images of human brain
Čı́žek, J., Herholz, K., Vollmar, S., Schrader, R., Klein, J., & Heiss, W.-D. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.01.016 · Cited by 172
Self-citationCerebral Blood Flow and Glucose Metabolism in Hypothyroidism: A Positron Emission Tomography Study
Constant, E. L. (2001) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.86.8.3864 · Cited by 166
A PET activation study of dynamic mechanical allodynia in patients with mononeuropathy
Petrovic, P., Ingvar, M., Stone-Elander, S., Petersson, M. K., & Hansson, P. (1999) · Pain · doi:10.1016/s0304-3959(99)00150-5 · Cited by 165
“Repeated measurements of rCBF (12 scans/subject, 4 scans/state) were made using an Ecat Exact HR PET scanner in 3D-sampling mode and 500 MBq bolus injections of [ 15 O]butanol producing 60 s tracer uptake images (Berridge et al., 1990; Ingvar et al., 1994; Wienhard et al., 1994).”
MethodIto, H., Hietala, J., Blomqvist, G., Halldin, C., & Farde, L. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199809000-00003 · Cited by 158
Arno, P., De Volder, A. G., Vanlierde, A., Wanet-Defalque, M.-C., Streel, E., Robert, A., Sanabria-Bohórquez, S., & Veraart, C. (2001) · NeuroImage · doi:10.1006/nimg.2000.0731 · Cited by 148
Activation of human medial prefrontal cortex during autonomic responses to hypoglycemia
Teves, D., Videen, T. O., Cryer, P. E., & Powers, W. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0307048101 · Cited by 138
Heiss, W.-D., Graf, R., Löttgen, J., Ohta, K., Fujita, T., Wagner, R., Grond, M., & Weinhard, K. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199704000-00004 · Cited by 132
Self-citationRENIER, L., COLLIGNON, O., POIRIER, C., TRANDUY, D., VANLIERDE, A., BOL, A., VERAART, C., & DEVOLDER, A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.047 · Cited by 128
“Measurements of local radioactivity uptake were made using an ECAT EXACT-HR PET tomograph (CTI/Siemens), which allows simultaneous imaging of 47 transaxial slices in threedimensional (3D, septa retracted) mode, with an effective resolution of 8-mm full width at half-maximum (FWHM) (Wienhard et al., 1994) and a slice t…”
MethodInfluentialGefvert, O., Eriksson, B., Persson, P., Helldin, L., Björner, A., Mannaert, E., Remmerie, B., Eerdekens, M., & Nyberg, S. (2005) · The International Journal of Neuropsychopharmacology · doi:10.1017/s1461145704004924 · Cited by 119
“At the Karolinska Hospital a Siemens ECAT Exact HR 47 (Knoxville, TN, USA) was used that measures radioactivity in the brain in 47 sections and the radioactivity was measured continuously for 51 min (Wienhart et al., 1994).”
MethodSeneca, N., Finnema, S. J., Farde, L., Gulyás, B., Wikström, H. V., Halldin, C., & Innis, R. B. (2006) · Synapse · doi:10.1002/syn.20238 · Cited by 110
“PET neuroreceptor imaging can be combined with a pharmacological challenge to measure indirectly the extracellular levels of neurotransmitters.”
BackgroundMethodInfluentialGulyás, B., Vas, Á., Tóth, M., Takano, A., Varrone, A., Cselényi, Z., Schain, M., Mattsson, P., & Halldin, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.020 · Cited by 94
“From these histograms the centre of gravity and FWHM (full width at half maximum)-to-peak ratio was calculated for each subject.”
InfluentialAttenuation of Counterregulatory Responses to Recurrent Hypoglycemia by Active Thalamic Inhibition
Arbelaez, A. M., Powers, W. J., Videen, T. O., Price, J. L., & Cryer, P. E. (2008) · Diabetes · doi:10.2337/db07-1329 · Cited by 92
“PET studies were performed with a Siemens/CTI (Knoxville, TN) ECAT EXACT HR 47 tomograph located in the Neurology-Neurosurgery Intensive Care Unit PET Research Facility (24).”
Stenkrona, P., Halldin, C., & Lundberg, J. (2013) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2013.01.002 · Cited by 78
Jucaite, A., Forssberg, H., Karlsson, P., Halldin, C., & Farde, L. (2010) · Neuroscience · doi:10.1016/j.neuroscience.2010.01.034 · Cited by 67
Lange, C., Kracht, L., Herholz, K., Sachsse, U., & Irle, E. (2005) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2005.05.003 · Cited by 63
PET measurement of serotonin transporter occupancy: a comparison of escitalopram and citalopram
Lundberg, J., Christophersen, J. S., Petersen, K. B., Loft, H., Halldin, C., & Farde, L. (2007) · The International Journal of Neuropsychopharmacology · doi:10.1017/s1461145706007486 · Cited by 55
“run in the 3D mode (Wienhard et al., 1994).”
MethodNETO, P. R., LOU, H., CUMMING, P., PRYDS, O., & GJEDDE, A. (2002) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2002.tb04184.x · Cited by 54
Karbe, H., Herholz, K., Weber-Luxenburger, G., Ghaemi, M., & Heiss, W.-D. (1998) · Brain and Language · doi:10.1006/brln.1997.1937 · Cited by 37
Self-citationBrody, A. L., Saxena, S., Stoessel, P., Gillies, L. A., Fairbanks, L. A., Alborzian, S., Phelps, M. E., Huang, S.-C., Wu, H.-M., Ho, M. L., et al. (2001) · Archives of General Psychiatry · doi:10.1001/archpsyc.58.7.631 · Cited by 5
Metadata
- Authors
- Wienhard, K., Dahlbom, M., Eriksson, L., Michel, C., Bruckbauer, T., Pietrzyk, U., & Heiss, W.-D.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1994-01
- Volume
- 18
- Issue
- 1
- Pages
- 110-118
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2089686687
- Cited by
- 561
- References
- 0
- FWCI
- 24.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.