Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Non-invasive self blood pressure monitoring has become increasingly popular. To assure the accuracy of devices used for this purpose, all need to be validated independently prior to marketing. The objective of this study was to assess the accuracy of the HEM-907, a new semi-automatic, non-invasive, oscillometric blood pressure monitoring device specifically designed to be used in the clinic or physician's office setting. METHODS: Blood pressure measurements taken employing this device were compared with the results obtained by two experienced observers using a mercury sphygmomanometer on 100 subjects and patients (384 measurements). The limits of agreement were calculated for the device compared with the results of the two observers according to the standards of the Association for the Advancement of Medical Instrumentation (AAMI). RESULTS: The agreement between the two observers was -0.36+/-2.32mmHg for systolic blood pressure and 0.02+/-2.42mmHg for diastolic blood pressure. The agreement between the device and the observers was 1.56+/-4.42mmHg and 3.49+/-4.61mmHg for systolic and diastolic blood pressure respectively. CONCLUSIONS: The Omron HEM-907 satisfied the AAMI criteria for accuracy for a non-invasive blood pressure monitoring device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Characterization of the oscillometric method for measuring indirect blood pressure
Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F. (1982) · Annals of Biomedical Engineering · doi:10.1007/bf02367308 · Cited by 340
Cited by
Appel, L. J., Sacks, F. M., Carey, V. J., Obarzanek, E., Swain, J. F., Miller, E. R., Conlin, P. R., Erlinger, T. P., Rosner, B. A., Laranjo, N. M., et al. (2005) · JAMA · doi:10.1001/jama.294.19.2455 · Cited by 1,170
Comparative Effectiveness of Weight-Loss Interventions in Clinical Practice
Appel, L. J., Clark, J. M., Yeh, H.-C., Wang, N.-Y., Coughlin, J. W., Daumit, G., Miller, E. R., Dalcin, A., Jerome, G. J., Geller, S., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1108660 · Cited by 783
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Quinn, R. R., Hemmelgarn, B. R., Padwal, R. S., Myers, M. G., Cloutier, L., Bolli, P., McKay, D. W., Khan, N. A., Hill, M. D., Mahon, J., et al. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70378-0 · Cited by 346
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J. (2011) · BMJ · doi:10.1136/bmj.d286 · Cited by 285
Validation of the Omron HEM-907 device for blood pressure measurement
El Assaad, M. A., Topouchian, J. A., Darné, B. M., & Asmar, R. G. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200208000-00006 · Cited by 279
Daskalopoulou, S. S., Khan, N. A., Quinn, R. R., Ruzicka, M., McKay, D. W., Hackam, D. G., Rabkin, S. W., Rabi, D. M., Gilbert, R. E., Padwal, R. S., et al. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.02.018 · Cited by 266
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Sacks, F. M., Carey, V. J., Anderson, C. A. M., Miller, E. R., Copeland, T., Charleston, J., Harshfield, B. J., Laranjo, N., McCarron, P., Swain, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.16658 · Cited by 239
El Assaad, M. A., Topouchian, J. A., & Asmar, R. G. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00006 · Cited by 224
Use of automated office blood pressure measurement to reduce the white coat response
Myers, M. G., Valdivieso, M., & Kiss, A. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32831b9e6b · Cited by 209
Samuel-Hodge, C. D., Keyserling, T. C., Park, S., Johnston, L. F., Gizlice, Z., & Bangdiwala, S. I. (2009) · The Diabetes Educator · doi:10.1177/0145721709333270 · Cited by 199
“Blood pressure was measured with the Omron HEM-907 automated blood pressure monitor (Omron Healthcare, Inc, Vernon Hills, IL).(27,28) Following a 5-minute rest, 3 blood pressure measures were obtained at 60-second intervals and averaged.”
Methodon behalf of Hypertension Objective Treatment Based on Measurement by Electrical Devices of Blood Pressure (HOMED-BP) investigators, Asayama, K., Ohkubo, T., Metoki, H., Obara, T., Inoue, R., Kikuya, M., Thijs, L., Staessen, J. A., & Imai, Y. (2012) · Hypertension Research · doi:10.1038/hr.2012.125 · Cited by 186
Asmar, R. (2011) · Vascular Health and Risk Management · doi:10.2147/vhrm.s27193 · Cited by 163
Topouchian, J. A., El Assaad, M. A., Orobinskaia, L. V., El Feghali, R. N., & Asmar, R. G. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000209078.17246.34 · Cited by 158
Palta, P., Page, G., Piferi, R. L., Gill, J. M., Hayat, M. J., Connolly, A. B., & Szanton, S. L. (2012) · Journal of Urban Health · doi:10.1007/s11524-011-9654-6 · Cited by 142
Agarwal, R. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.116.004536 · Cited by 144
“This device has been validated by several investigators using standardized protocols.(5,6) The monitor was programmed such that the cuff did not start to inflate until the participant rested quietly for 5 minutes in a seated position with the arm at the level of the heart.”
MethodDregan, A., Rayner, L., Davis, K. A. S., Bakolis, I., Arias de la Torre, J., Das-Munshi, J., Hatch, S. L., Stewart, R., & Hotopf, M. (2020) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2019.4712 · Cited by 132
Matsui, Y., O'Rourke, M. F., Hoshide, S., Ishikawa, J., Shimada, K., & Kario, K. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.189217 · Cited by 104
“It was shown that HEM-907 and HEM747IC had the same algorithm for deriving systolic BP (SBP) and diastolic BP from the oscillometric readings.(20,22) The arm circumferences of the subjects ranged between 22 and 32 cm, so a standard arm cuff could be used for BP measurement in all of the cases.”
MethodHara, A., Tanaka, K., Ohkubo, T., Kondo, T., Kikuya, M., Metoki, H., Hashimoto, T., Satoh, M., Inoue, R., Asayama, K., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.174938 · Cited by 79
Zhong, X., Qiang, Y., Wang, L., Zhang, Y., Li, J., Feng, J., Cheng, W., Tan, L., & Yu, J. (2023) · Translational Psychiatry · doi:10.1038/s41398-023-02683-0 · Cited by 55
Amoore, J. N., Vacher, E., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32826fb773 · Cited by 34
Measuring and managing blood pressure in a primary care setting: a pragmatic implementation study
Doane, J., Buu, J., Penrod, M. J., Bischoff, M., Conroy, M. B., & Stults, B. (2018) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2018.03.170450 · Cited by 23
Prevalence of Metabolic Syndrome Risk Factors Among Young Adult Asian Indians
Shah, T., Jonnalagadda, S. S., Kicklighter, J. R., Diwan, S., & Hopkins, B. L. (2005) · Journal of Immigrant Health · doi:10.1007/s10903-005-2645-5 · Cited by 19
Sano, H., Hara, A., Asayama, K., Miyazaki, S., Kikuya, M., Imai, Y., & Ohkubo, T. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-040524 · Cited by 11
Metadata
- Authors
- White, W. B., & Anwar, Y. A.
- Venue
- Blood Pressure Monitoring
- Published
- 2001-04
- Volume
- 6
- Issue
- 2
- Pages
- 107-110
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2047667671
- Cited by
- 213
- References
- 2
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.