Nonlinear Finite Element Model Predicts Vertebral Bone Strength and Fracture Site
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
In Brief Study Design. A study on computed tomography (CT)-based finite element (FE) method that predicts vertebral strength and fracture site using human cadaveric specimens. Objective. To evaluate the accuracy of the nonlinear FE method by comparing the predicted data with those of mechanical testing. Summary of Background Data. FE methods may predict vertebral strength and fracture site but the prediction has been difficult because of a complex geometry, elastoplasticity, and thin cortical shell of the vertebra. Methods. FE models of the 12 thoracolumbar vertebral specimens were constructed. Nonlinear FE analyses were performed, and the yield load, the fracture load, the sites where elements failed, and the distribution of minimum principal strain were evaluated. A quasi-static uniaxial compression test for the same specimens was conducted to verify these analyses. Results. The yield loads, fracture loads, minimum principal strains, and fracture sites of the FE prediction significantly correlated with those measured. Conclusions. Nonlinear FE model predicted vertebral strength and fracture site accurately. Nonlinear finite element analysis was evaluated by performing mechanical testing using human cadaveric specimens. Twelve thoracolumbar vertebrae were analyzed, and quasi-static uniaxial compression test was conducted to verify these analyses. Yield loads, fracture loads, minimum principal strains, and fracture sites of the finite element prediction significantly correlated with those measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Prediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682 · cited 6×
“Young’s modulus and yield stress of each tetrahedron element were calculated from the equations proposed by Keyak et al.10 Young’s modulus of human vertebra cancellous tissue was reported as 3.8 to 13.4 GPa25–28; Young’s modulus of each triangular-plate was set as 10 GPa.”
MethodInfluentialPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 1×
“The yield strain of human vertebral trabecular bone was reported 7,000 to 10,000 microstrain.(17,18) Therefore, we adopted minimum strain of 10,000 microstrain as a criterion for element collapse.”
MethodCrawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Femoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432 · cited 1×
“It has been reported that in previous experiments thin cortical shell of the vertebrae contributed approximately 10% to the overall vertebral strength in healthy individuals and the contribution of the cortical shell was estimated to be significantly larger in osteoporotic individuals.(2,30) Thus, the importance of th…”
BackgroundKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330 · cited 1×
“The yield strain of human vertebral trabecular bone was reported 7,000 to 10,000 microstrain.(17,18) Therefore, we adopted minimum strain of 10,000 microstrain as a criterion for element collapse.”
MethodImproved prediction of proximal femoral fracture load using nonlinear finite element models
Keyak, J. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00045-5 · Cited by 314
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309 · cited 1×
“In previous studies, von Mises equivalent stress has been used as the criterion of yield.(8,10,13) For ductile materials such as metals, von Mises criterion would be effective, but for bones it seems more appropriate to use Drucker-Prager equivalent stress.”
MethodBiologically meaningful determinants of the in vitro strength of lumbar vertebrae
Vesterby, A., Mosekilde, L., Gundersen, H. J. G., Melsen, F., Mosekilde, L., Holme, K., & Sørensen, S. (1991) · Bone · doi:10.1016/8756-3282(91)90044-j · Cited by 233
Prevrhal, S., Engelke, K., & Kalender, W. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/017 · Cited by 226 · cited 1×
“The thickness tends to be overestimated and its density to be underestimated.(23,24) Therefore, it would be necessary to construct a thinner part of the cortical shell from data that is independent of QCT data.”
BackgroundFaulkner, K. G., Cann, C. E., & Hasegawa, B. H. (1991) · Radiology · doi:10.1148/radiology.179.3.2027972 · Cited by 215 · cited 1×
“It has been reported that in previous experiments thin cortical shell of the vertebrae contributed approximately 10% to the overall vertebral strength in healthy individuals and the contribution of the cortical shell was estimated to be significantly larger in osteoporotic individuals.(2,30) Thus, the importance of th…”
BackgroundSilva, M. J., Wang, C., Keaveny, T. M., & Hayes, W. C. (1994) · Bone · doi:10.1016/8756-3282(94)90817-6 · Cited by 210
Human vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S. M., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 197
A model of vertebral trabecular bone architecture and its mechanical properties
Jensen, K. S., Mosekilde, L., & Mosekilde, L. (1990) · Bone · doi:10.1016/8756-3282(90)90137-n · Cited by 180
Prediction of the compressive strength of human lumbar vertebrae
Brinckmann, P., Biggemann, M., & Hilweg, D. (1989) · Clinical Biomechanics · doi:10.1016/0268-0033(89)90071-5 · Cited by 175
Ladd, A. J. C., Kinney, J. H., Haupt, D. L., & Goldstein, S. A. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160516 · Cited by 171
Finite Element Modeling of the Human Thoracolumbar Spine
Liebschner, M. A. K., Kopperdahl, D. L., Rosenberg, W. S., & Keaveny, T. M. (2003) · Spine · doi:10.1097/01.brs.0000049923.27694.47 · Cited by 165
Mosekilde, L., Bentzen, S. M., Ørtoft, G., & Jørgensen, J. (1989) · Bone · doi:10.1016/8756-3282(89)90080-x · Cited by 161
Vertebral structure and strengthIn vivo andIn vitro
Mosekilde, L. (1993) · Calcified Tissue International · doi:10.1007/bf01673420 · Cited by 158
Silva, M. J., Keaveny, T. M., & Hayes, W. C. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160305 · Cited by 143 · cited 1×
“In previous studies, von Mises equivalent stress has been used as the criterion of yield.(8,10,13) For ductile materials such as metals, von Mises criterion would be effective, but for bones it seems more appropriate to use Drucker-Prager equivalent stress.”
MethodFracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895413 · Cited by 115
Katsamanis, F., & Raftopoulos, D. D. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90010-z · Cited by 96 · cited 1×
“2 GPa (static).(32) Young’s modulus of human vertebra cancellous tissue was reported as 3.”
BackgroundMyers, B. S., Arbogast, K. B., Lobaugh, B., Harper, K. D., Richardson, W. J., & Drezner, M. K. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090514 · Cited by 91
Bjarnason, K., Hassager, C., Svendsen, O. L., Stang, H., & Christiansen, C. (1996) · Osteoporosis International · doi:10.1007/bf01626536 · Cited by 73
Edmondston, S. J., Singer, K. P., Day, R. E., Breidahl, P. D., & Price, R. I. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90019-1 · Cited by 52
Overaker, D. W., Langrana, N. A., & Cuitiño, A. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835085 · Cited by 39 · cited 2×
“They concluded that Young’s modulus of 7 GPa precisely correlated with the experimental result.(29) Liebschner et al set the thickness as 0.”
Method
Cited by
Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
Orwoll, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K., Lane, N., Hoffmann, P. R., Kopperdahl, D. L., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 265
Dall’Ara, E., Pahr, D., Varga, P., Kainberger, F., & Zysset, P. (2012) · Osteoporosis International · doi:10.1007/s00198-011-1568-3 · Cited by 181
“The subject-specific QCT-based nonlinear FE models can predict the post-yield behavior of bone and have been shown to predict vertebral stiffness and ultimate load in vitro better than BMD [36–41].”
BackgroundPrediction of incident vertebral fracture using CT-based finite element analysis
Allaire, B. T., Lu, D., Johannesdottir, F., Kopperdahl, D., Keaveny, T. M., Jarraya, M., Guermazi, A., Bredella, M. A., Samelson, E. J., Kiel, D. P., et al. (2019) · Osteoporosis International · doi:10.1007/s00198-018-4716-1 · Cited by 95
Metadata
- Authors
- Imai, K., Ohnishi, I., Bessho, M., & Nakamura, K.
- Venue
- Spine
- Published
- 2006-07
- Volume
- 31
- Issue
- 16
- Pages
- 1789-1794
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2067748909
- Cited by
- 196
- References
- 32
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.