CoChat

Epidemiology of sedation and sedation adequacy for mechanically ventilated patients in a medical and surgical intensive care unit*

Weinert, Craig R., Calvin, Andrew D. · 2007 · Critical Care Medicine
Cited by 167

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Describe the pharmacoepidemiology of sedative medications and nurse-rated patients' behavior and sedation adequacy. DESIGN: Cohort study, 2001-2003. PATIENTS: Patients ventilated for >36 hrs in a medical or surgical intensive care unit at a university-affiliated hospital. Proxies for 312 eligible subjects were approached for consent, 277 subjects enrolled, and data from 274 subjects were analyzed. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Distribution of Arousal and Motor Activity levels, proportion of inadequate sedation and factors associated with inadequate sedation, variation of sedative therapy intensity, and behavior over time were measured. Sedatives were administered in 85% of 18,050 four-hour intervals during mechanical ventilation. Sedation was judged as adequate in 83% of 12,414 sedation assessments; patients were judged to be undersedated in 13.9% and oversedated in 2.6% of the assessments. Patients were unarousable or minimally arousable 32% of the time and had no spontaneous motor activity (during a 10-min observation period) 21.5% of the time. There was little variation in level of consciousness or motor activity or drug dose over 24 hrs, but daytime caregivers were more likely to judge patients as oversedated (3.7%) compared with nighttime caregivers (1.6%, p<.001). Inadequate sedation was associated with sedative drug intensity and patient behavior as measured by a two-domain sedation scale. Sedative drug intensity and behavior varied during the course of respiratory failure, and survivors received 13% more sedation per 4-hr interval of mechanical ventilation than nonsurvivors (p<.001). CONCLUSIONS: Although patients were minimally arousable or nonarousable in 32% and motionless in 21% of the sedation assessments, surprisingly, an oversedation rating occurred in <3%. This discrepancy, along with findings that time of day influences the interpretation of sedation adequacy and that patients' behavior change over time suggests that collaborative research is needed to define adequate sedation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000254339.18639.1d

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Weinert, C. R., & Calvin, A. D.
Venue
Critical Care Medicine
Published
2007-02
Volume
35
Issue
2
Pages
393-401
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2085533388
Cited by
167
References
31
FWCI
12.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.