Diffuse Optical Tomography of Cerebral Blood Flow, Oxygenation, and Metabolism in Rat during Focal Ischemia
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
Diffuse optical tomography (DOT) is an attractive approach for evaluating stroke physiology. It provides hemodynamic and metabolic imaging with unique potential for continuous noninvasive bedside imaging in humans. To date there have been few quantitative spatial-temporal studies of stroke pathophysiology based on diffuse optical signatures. The authors report DOT images of hemodynamic and metabolic contrasts using a rat middle cerebral artery occlusion (MCAO) stroke model. This study used a novel DOT device that concurrently obtains coregistered images of relative cerebral blood volume (rCBV), tissue-averaged hemoglobin oxygen saturation (Sto 2), and relative cerebral blood flow (rCBF). The authors demonstrate how these hemodynamic measures can be synthesized to calculate an index of the oxygen extraction fraction (OEF) and the cerebral metabolic rate of oxygen consumption (CMRo 2). Temporary (60-minute) MCAO was performed on five rats. Ischemic changes, averaged over the 60 minutes of occlusion, were as follows: rCBF = 0.42 ± 0.04, rCBV = 1.02 ± 0.04, ΔSto 2 = −11 ± 2%, rOEF = 1.39 ± 0.06 and rCMRo 2 = 0.59 ± 0.07. Although rOEF increased in response to decreased blood flow, rCMRo 2 decreased. The sensitivity of this method of DOT analysis is discussed in terms of assumptions about baseline physiology, and the diffuse optical results are compared with positron emission tomography, magnetic resonance imaging, and histology observations in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reversible middle cerebral artery occlusion without craniectomy in rats.
Longa, E. Z., Weinstein, P. R., Carlson, S., & Cummins, R. (1989) · Stroke · doi:10.1161/01.str.20.1.84 · Cited by 7,463 · cited 2×
“Focal ischemia was induced by intraluminal suture occlusion of the middle cerebral artery (Koizumi et al., 1985; Longa et al., 1989).”
MethodPrinciples of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Functional architecture of cortex revealed by optical imaging of intrinsic signals
Grinvald, A., Lieke, E., Frostig, R. D., Gilbert, C. D., & Wiesel, T. N. (1986) · Nature · doi:10.1038/324361a0 · Cited by 1,244
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationRecent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Prospects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Photoacoustic imaging and characterization of the microvasculature
Hu, S., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3281673 · Cited by 427
Retinotopic mapping of adult human visual cortex with high-density diffuse optical tomography
Zeff, B. W., White, B. R., Dehghani, H., Schlaggar, B. L., & Culver, J. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611266104 · Cited by 351
Self-citationDurduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Self-citationChoe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Self-citationResting-state functional connectivity in the human brain revealed with diffuse optical tomography
White, B. R., Snyder, A. Z., Cohen, A. L., Petersen, S. E., Raichle, M. E., Schlaggar, B. L., & Culver, J. P. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.058 · Cited by 287
Self-citationDunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Self-citationImaging of Functional Connectivity in the Mouse Brain
White, B. R., Bauer, A. Q., Snyder, A. Z., Schlaggar, B. L., Lee, J.-M., & Culver, J. P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016322 · Cited by 253
Self-citationOverview of diffuse optical tomography and its clinical applications
Hoshi, Y., & Yamada, Y. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091312 · Cited by 249
“72 To solve these issues, spatial variant regularization 73,74 and high-density source-detector arrangements 68 have been used.”
MethodThe role of photodynamic therapy (PDT) physics
Zhu, T. C., & Finlay, J. C. (2008) · Medical Physics · doi:10.1118/1.2937440 · Cited by 244
Eggebrecht, A. T., White, B. R., Ferradal, S. L., Chen, C., Zhan, Y., Snyder, A. Z., Dehghani, H., & Culver, J. P. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.124 · Cited by 239
“These findings along with parallel studies in rodent models (Bouchard et al., 2009; Culver et al., 2003; Custo et al., 2009; Devor et al., 2003; Dunn et al., 2005; Siegel et al., 2003) and human neonates (Villringer and Chance, 1997) lay the foundation for optical measurements to be used in calculations of metabolic m…”
Self-citationYu, G., Durduran, T., Zhou, C., Wang, H.-W., Putt, M. E., Saunders, H. M., Sehgal, C. M., Glatstein, E., Yodh, A. G., & Busch, T. M. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2582 · Cited by 234
Self-citationZhou, C., Yu, G., Furuya, D., Greenberg, J. H., Yodh, A. G., & Durduran, T. (2006) · Optics Express · doi:10.1364/oe.14.001125 · Cited by 232
Self-citationYu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
“The lack of portable, noninvasive technologies for continuous monitoring of both blood flow and oxygenation in the deep microcirculation~capillary bed! has led us to develop a hybrid instrument combining near-infrared DCS and diffuse reflectance spectroscopy ~DRS!.(19,20)DCS monitors blood flow by effectively measurin…”
BackgroundSelf-citationYu, G., Floyd, T. F., Durduran, T., Zhou, C., Wang, J., Detre, J. A., & Yodh, A. G. (2007) · Optics Express · doi:10.1364/oe.15.001064 · Cited by 223
Self-citationSingle-cell label-free photoacoustic flowoxigraphy in vivo
Wang, L., Maslov, K., & Wang, L. V. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1215578110 · Cited by 218
“To quantify tissue oxygenation in vivo, three primary imaging modalities have been applied: positron emission tomography (PET) (8), functional magnetic resonance imaging (fMRI) (9, 10), and diffuse optical tomography (DOT) (11).”
MethodDiffuse correlation spectroscopy for measurement of cerebral blood flow: future prospects
Buckley, E. M., Parthasarathy, A. B., Grant, P. E., Yodh, A. G., & Franceschini, M. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011009 · Cited by 216
“Additionally, DCS has been used to extract depth-resolved spatial maps of blood flow.(37,39) In sum, these studies have demonstrated the potential of DCS in preclinical and neuroscience animal studies.”
MethodSelf-citationMicrovascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
Cerebral Oxygen Metabolism in Neonates with Congenital Heart Disease Quantified by MRI and Optics
Jain, V., Buckley, E. M., Licht, D. J., Lynch, J. M., Schwab, P. J., Naim, M. Y., Lavin, N. A., Nicolson, S. C., Montenegro, L. M., Yodh, A. G., et al. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.214 · Cited by 198
Self-citationDurduran, T., Zhou, C., Buckley, E. M., Kim, M. N., Yu, G., Choe, R., Gaynor, J. W., Spray, T. L., Durning, S. M., Mason, S. E., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3425884 · Cited by 196
Self-citationDirect measurement of tissue blood flow and metabolism with diffuse optics
Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0232 · Cited by 195
Self-citationBuckley, E. M., Cook, N. M., Durduran, T., Kim, M. N., Zhou, C., Choe, R., Yu, G., Schultz, S., Sehgal, C. M., Licht, D. J., et al. (2009) · Optics Express · doi:10.1364/oe.17.012571 · Cited by 179
Self-citationDiffuse optical monitoring of hemodynamic changes in piglet brain with closed head injury
Zhou, C., Eucker, S. A., Durduran, T., Yu, G., Ralston, J., Friess, S. H., Ichord, R. N., Margulies, S. S., & Yodh, A. G. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3146814 · Cited by 176
Self-citationThe effect of different anesthetics on neurovascular coupling
Franceschini, M. A., Radhakrishnan, H., Thakur, K., Wu, W., Ruvinskaya, S., Carp, S., & Boas, D. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.060 · Cited by 173
“Previously, we verified that the hemoglobin response measured with this system and probe in rats is co-localized and temporally equivalent to the BOLD response measured with fMRI (Culver et al., 2003b; Siegel et al., 2003).”
MethodResultInfluentialSimple and robust image-based autofocusing for digital microscopy
Yazdanfar, S., Kenny, K. B., Tasimi, K., Corwin, A. D., Dixon, E. L., & Filkins, R. J. (2008) · Optics Express · doi:10.1364/oe.16.008670 · Cited by 171
Optical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
Self-citationHigh-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
Self-citationDurduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200405000-00005 · Cited by 168
“It is also qualitatively similar to other hemodynamic measurements, such as those of diffuse optical tomography (Culver et al., 2003b), functional magnetic resonance imaging (Duong et al., 2000; Hyder et al., 1994; Mandeville et al., 1998), and optical intrinsic signal imaging (Narayan et al.,…”
BackgroundMethodResultInfluentialSelf-citationBoas, D. A., Chen, K., Grebert, D., & Franceschini, M. A. (2004) · Optics Letters · doi:10.1364/ol.29.001506 · Cited by 166
Noninvasive detection of functional brain activity with near-infrared diffusing-wave spectroscopy
Li, J., Dietsche, G., Iftime, D., Skipetrov, S. E., Maret, G., Elbert, T., Rockstroh, B., & Gisler, T. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2007987 · Cited by 166
“The interpretation in terms of increased flow velocity of erythrocytes in the cortical vessels was also supported by parallel NIRS and DWS experiments on a rat brain during focal ischemia.(31) Using motor cortex stimulation by finger opposition, Durduran et al.”
MethodTranscranial optical monitoring of cerebrovascular hemodynamics in acute stroke patients
Durduran, T., Zhou, C., Edlow, B. L., Yu, G., Choe, R., Kim, M. N., Cucchiara, B. L., Putt, M. E., Shah, Q., Kasner, S. E., et al. (2009) · Optics Express · doi:10.1364/oe.17.003884 · Cited by 166
Self-citationWhite, B. R., & Culver, J. P. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3368999 · Cited by 162
“26,27 The inverse problem minimizes the objec-tive function: min (cid:7)(cid:8) y meas − Ax (cid:8) 22 + (cid:2) (cid:8) Ix (cid:8)(cid:9) .”
Self-citationTreatment-Induced Changes in Tumor Oxygenation Predict Photodynamic Therapy Outcome
Wang, H.-W., Putt, M. E., Emanuele, M. J., Shin, D. B., Glatstein, E., Yodh, A. G., & Busch, T. M. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-3632 · Cited by 161
“In addition, validation of our diffuse optical reflectance approach in tissues has been reported in brain activation (33, 45) and tumor studies (46).”
BackgroundSelf-citationGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Gurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
Metadata
- Authors
- Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2003-08
- Volume
- 23
- Issue
- 8
- Pages
- 911-924
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2025941430
- Cited by
- 420
- References
- 57
- FWCI
- 14.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.