Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness: A “Gray Zone” Approach
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: Respiratory arterial pulse pressure variations (PPV) are the best predictors of fluid responsiveness in mechanically ventilated patients during general anesthesia. However, previous studies were performed in a small number of patients and determined a single cutoff point to make clinical discrimination. The authors sought to test the predictive value of PPV in a large, multicenter study and to express it using a gray zone approach. Methods: The authors studied 413 patients during general anesthesia and mechanical ventilation in four centers. PPV, central venous pressure, and cardiac output were recorded before and after volume expansion (VE). Response to VE was defined as more than 15% increase in cardiac output after VE. The following approaches were used to determine the gray zones: resampled and two-graph receiver operator characteristic curves. The impact of changes in the benefit-risk balance of VE on the gray zone was also evaluated. Results: The authors observed 209 responders (51%) and 204 nonresponders (49%) to VE. The area under receiver operating characteristic curve was 0.89 (95% CI: 0.86-0.92) for PPV, compared with 0.57 (95% CI: 0.54-0.59) for central venous pressure (P < 10). The gray zone approach identified a range of PPV values (between 9% and 13%) for which fluid responsiveness could not be predicted reliably. These PPV values were seen in 98 (24%) patients. Changes in the cost ratio of VE moderately affected the gray zone limits. Conclusion: Despite a strong predictive value, PPV may be inconclusive (between 9% and 13%) in approximately 25% of patients during general anesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
ROCR: visualizing classifier performance in R
Sing, T., Sander, O., Beerenwinkel, N., & Lengauer, T. (2005) · Bioinformatics · doi:10.1093/bioinformatics/bti623 · Cited by 3,200
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Kozek-Langenecker, S. A., Ahmed, A. B., Afshari, A., Albaladejo, P., Aldecoa, C., Barauskas, G., De Robertis, E., Faraoni, D., Filipescu, D. C., Fries, D., et al. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000630 · Cited by 800
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308
Perioperative fluid therapy: a statement from the international Fluid Optimization Group
Navarro, L. H. C., Bloomstone, J. A., Auler, J. O. C., Cannesson, M., Rocca, G. D., Gan, T. J., Kinsky, M., Magder, S., Miller, T. E., Mythen, M., et al. (2015) · Perioperative Medicine · doi:10.1186/s13741-015-0014-z · Cited by 298
Self-citationNoninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
A rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., et al. (2015) · Critical Care · doi:10.1186/s13054-015-0932-7 · Cited by 243
Eskesen, T. G., Wetterslev, M., & Perner, A. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4168-4 · Cited by 225
Fluid responsiveness: an evolution of our understanding
Marik, P. E., & Lemson, J. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aet590 · Cited by 201
Long, E., Oakley, E., Duke, T., & Babl, F. E. (2017) · Shock · doi:10.1097/shk.0000000000000801 · Cited by 200
Arterial Pulse Pressure Variation with Mechanical Ventilation
Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201801-0088ci · Cited by 200
“between 9 and 13%) where no conclusion can be drawn about fluid responsiveness, even when tidal volume is ≥ 8mL/kg (71).”
BackgroundGuidelines for perioperative haemodynamic optimization
Vallet, B., Blanloeil, Y., Cholley, B., Orliaguet, G., Pierre, S., & Tavernier, B. (2013) · Annales Françaises d'Anesthésie et de Réanimation · doi:10.1016/j.annfar.2013.09.010 · Cited by 198
Self-citationFunctional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
“While PPV has a strong predictive value, a recent study has demonstrated that values between 9-13% are inconclusive in patients undergoing general anesthesia [48].”
Background
Metadata
- Authors
- Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B.
- Venue
- Anesthesiology
- Published
- 2011-08-01
- Volume
- 115
- Issue
- 2
- Pages
- 231-241
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1994385356
- Cited by
- 554
- References
- 29
- FWCI
- 38.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.