Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness: A “Gray Zone” Approach
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: Respiratory arterial pulse pressure variations (PPV) are the best predictors of fluid responsiveness in mechanically ventilated patients during general anesthesia. However, previous studies were performed in a small number of patients and determined a single cutoff point to make clinical discrimination. The authors sought to test the predictive value of PPV in a large, multicenter study and to express it using a gray zone approach. Methods: The authors studied 413 patients during general anesthesia and mechanical ventilation in four centers. PPV, central venous pressure, and cardiac output were recorded before and after volume expansion (VE). Response to VE was defined as more than 15% increase in cardiac output after VE. The following approaches were used to determine the gray zones: resampled and two-graph receiver operator characteristic curves. The impact of changes in the benefit-risk balance of VE on the gray zone was also evaluated. Results: The authors observed 209 responders (51%) and 204 nonresponders (49%) to VE. The area under receiver operating characteristic curve was 0.89 (95% CI: 0.86-0.92) for PPV, compared with 0.57 (95% CI: 0.54-0.59) for central venous pressure (P < 10). The gray zone approach identified a range of PPV values (between 9% and 13%) for which fluid responsiveness could not be predicted reliably. These PPV values were seen in 98 (24%) patients. Changes in the cost ratio of VE moderately affected the gray zone limits. Conclusion: Despite a strong predictive value, PPV may be inconclusive (between 9% and 13%) in approximately 25% of patients during general anesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
ROCR: visualizing classifier performance in R
Sing, T., Sander, O., Beerenwinkel, N., & Lengauer, T. (2005) · Bioinformatics · doi:10.1093/bioinformatics/bti623 · Cited by 3,200
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Statistical Evaluation of a Biomarker
Ray, P., Manach, Y. L., Riou, B., Houle, T. T., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d47604 · Cited by 503
Peyton, P. J., & Chong, S. W. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ee3130 · Cited by 456
Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F. (2007) · Critical Care · doi:10.1186/cc6117 · Cited by 442
Derichard, A., Robin, E., Tavernier, B., Costecalde, M., Fleyfel, M., Onimus, J., Lebuffe, G., Chambón, J. P., & Vallet, B. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep267 · Cited by 393
Self-citationMayer, J., Boldt, J., Mengistu, A., Röhm, K. D., & Suttner, S. W. (2010) · Critical Care · doi:10.1186/cc8875 · Cited by 320
Hofer, C. K., Müller, S. M., Furrer, L., Klaghofer, R., Genoni, M., & Zollinger, A. (2005) · Chest · doi:10.1378/chest.128.2.848 · Cited by 279
Self-citationHofer, C. K., Senn, A., Weibel, L., & Zollinger, A. (2008) · Critical Care · doi:10.1186/cc6933 · Cited by 222
Self-citationCannesson, M., Attof, Y., Rosamel, P., Desebbe, O., Joseph, P., Metton, O., Bastien, O., & Lehot, J.-J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267593.72744.20 · Cited by 216
Self-citationCannesson, M., Musard, H., Desebbe, O., Boucau, C., Simon, R., Hénaine, R., & Lehot, J.-J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318192a36b · Cited by 214
Self-citationBiais, M., Nouette-Gaulain, K., Cottenceau, V., Revel, P., & Sztark, F. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen277 · Cited by 180
Non-invasive prediction of fluid responsiveness during major hepatic surgery † ‡
Solus-Biguenet, H., Fleyfel, M., Tavernier, B., Kipnis, E., Onimus, J., Robin, E., Lebuffe, G., Decoene, C., Pruvot, F. R., & Vallet, B. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael250 · Cited by 169
Self-citationZimmermann, M., Feibicke, T., Keyl, C., Prasser, C., Moritz, S., Graf, B. M., & Wiesenack, C. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e328335fbd1 · Cited by 167
Monnet, X., Anguel, N., Naudin, B., Jabot, J., Richard, C., & Teboul, J. (2010) · Critical Care · doi:10.1186/cc9058 · Cited by 140
Arterial Pressure Variation and Goal-Directed Fluid Therapy
Cannesson, M. P. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.10.008 · Cited by 124
Self-citationCannesson, M. P., Slieker, J. C., Desebbe, O., Bauer, C., Chiari, P. C., Hénaine, R., & Lehot, J. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297291.01615.5c · Cited by 118
Self-citationThe inadequacy of binary models for the clinical reality of three-zone diagnostic decisions
Feinstein, A. R. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90064-v · Cited by 96
Teboul, J., Besbes, M., Andrivet, P., Axler, O., Douguet, D., Zelter, M., Lemaire, F., & Brun‐Buisson, C. (1992) · Journal of Critical Care · doi:10.1016/0883-9441(92)90005-r · Cited by 94
Is It a Bird? Is It a Plane? The Role of Patient Monitors in Medical Decision Making
Feldman, J. M. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318196c7b6 · Cited by 40
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Kozek-Langenecker, S. A., Ahmed, A. B., Afshari, A., Albaladejo, P., Aldecoa, C., Barauskas, G., De Robertis, E., Faraoni, D., Filipescu, D. C., Fries, D., et al. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000630 · Cited by 800
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308
Metadata
- Authors
- Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B.
- Venue
- Anesthesiology
- Published
- 2011-08-01
- Volume
- 115
- Issue
- 2
- Pages
- 231-241
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1994385356
- Cited by
- 554
- References
- 29
- FWCI
- 38.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.