Non-invasive Breath Analysis of Pulmonary Nodules
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Introduction: The search for non-invasive diagnostic methods of lung cancer (LC) has led to new avenues of research, including the exploration of the exhaled breath. Previous studies have shown that LC can, in principle, be detected through exhaled-breath analysis. This study evaluated the potential of exhaled-breath analysis for the distinction of benign and malignant pulmonary nodules (PNs). Methods: Breath samples were taken from 72 patients with PNs in a prospective trial. Profiles of volatile organic compounds were determined by (1) gas chromatography/mass spectrometry (GC-MS) combined with solid-phase microextraction and (2) a chemical nanoarray. Results: Fifty-three PNs were malignant and 19 were benign with similar smoking histories and comorbidities. Nodule size (mean ± SD) was 2.7 ± 1.7 versus 1.6 ± 1.3 cm (p = 0.004), respectively. Within the malignant group, 47 were non–small-cell lung cancer and six were small-cell lung cancer. Thirty patients had early-stage disease and 23 had advanced disease. Gas chromatography/mass spectrometry analysis identified a significantly higher concentration of 1-octene in the breath of LC, and the nanoarray distinguished significantly between benign versus malignant PNs (p < 0.0001; accuracy 88 ± 3%), between adeno- and squamous-cell carcinomas [LINE SEPARATOR](p < 0.0001; 88 ± 3%) and between early stage and advanced disease (p < 0.0001; 88 ± 2%). Conclusions: In this pilot study, breath analysis discriminated benign from malignant PNs in a high-risk cohort based on LC-related volatile organic compound profiles. Furthermore, it discriminated adeno- and squamous-cell carcinoma and between early versus advanced disease. Further studies are required to validate this noninvasive approach, using a larger cohort of patients with PNs detected by computed tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064 · cited 1×
“The National Lung Screening Trial demonstrated that LC screening by low-dose computed tomography (LDCT) scans reduced the LC mortality rate by 20%.(3) LDCT screening programs for LC are expected to be launched in many countries in the near future so that a dramatic increase in the detection of pulmonary nodules (PNs)…”
BackgroundSiegel, R., Naishadham, D., & Jemal, A. (2012) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20138 · Cited by 10,679
Cytochrome P-450: Structure, Mechanism, and Biochemistry
de Montellano, O., & Paul, R. (1986) · Medical Entomology and Zoology · Cited by 2,663
Cancer cell metabolism: warburg and beyond
Hsu, P. P., & Sabatini, D. M. (2008) · Cell · doi:10.1016/j.cell.2008.08.021 · Cited by 2,452 · cited 1×
“It would be reasonable to expect a higher quantity and variety of metabolites released by the SCLC, because SCLC cells are rapidly dividing cells that require more adenosine triphosphate, nucleotides, fatty acids, membrane lipids, and proteins.(30) This assumption is based on our previous report of pronounced differen…”
BackgroundDiagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263 · cited 2×
“Previous studies with exhaled breath have compared LC patients with chronic obstructive pulmonary disease patients or with healthy subjects, with either GC-MS(9,10,12,13) or chemical sensors.(4,5,9,10,18,20) In contrast, this study used both techniques and compared exhaled breath of patients with either malignant or b…”
MethodResultSelf-citationVolatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918 · cited 1×
“In general, GC-MS yields a wealth of information for basic research.(9,10,12,13,18) However, this method has several prominent disadvantages for use as a clinical point-of-care application.”
MethodPeng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775 · cited 2×
“Previous studies with exhaled breath have compared LC patients with chronic obstructive pulmonary disease patients or with healthy subjects, with either GC-MS(9,10,12,13) or chemical sensors.(4,5,9,10,18,20) In contrast, this study used both techniques and compared exhaled breath of patients with either malignant or b…”
MethodResultSelf-citationDetection of Lung Cancer by Sensor Array Analyses of Exhaled Breath
Machado, R. F., Laskowski, D., Deffenderfer, O., Burch, T., Zheng, S., Mazzone, P. J., Mekhail, T., Jennings, C., Stoller, J. K., Pyle, J., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1184oc · Cited by 602
Towards high charge-carrier mobilities by rational design of the shape and periphery of discotics
Feng, X., Marcon, V., Pisula, W., Hansen, M. R., Kirkpatrick, J., Grozema, F., Andrienko, D., Kremer, K., & Müllen, K. (2009) · Nature Materials · doi:10.1038/nmat2427 · Cited by 588
Detection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Cited by
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationBiomarkers in Lung Cancer Screening: Achievements, Promises, and Challenges
Seijo, L. M., Peled, N., Ajona, D., Boeri, M., Field, J. K., Sozzi, G., Pio, R., Zulueta, J. J., Spira, A., Massion, P. P., et al. (2019) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2018.11.023 · Cited by 539
Self-citationFlexible Sensors Based on Nanoparticles
Segev-Bar, M., & Haick, H. (2013) · ACS Nano · doi:10.1021/nn402728g · Cited by 511
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citationReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Electronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Self-citationNanomaterial-Based Sensors for Detection of Disease by Volatile Organic Compounds
Broza, Y. Y., & Haick, H. (2013) · Nanomedicine · doi:10.2217/nnm.13.64 · Cited by 358
Self-citationAdvanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Self-citationBreath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Hybrid Volatolomics and Disease Detection
Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A., & Haick, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500153 · Cited by 290
Self-citationExhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Self-citationShehada, N., Brönstrup, G., Funka, K., Christiansen, S., Leja, M., & Haick, H. (2015) · Nano Letters · doi:10.1021/nl504482t · Cited by 255
Hanna, G. B., Boshier, P. R., Markar, S. R., & Romano, A. (2019) · JAMA Oncology · doi:10.1001/jamaoncol.2018.2815 · Cited by 237
“8 4 7 Peled 2012 L u ?”
Artificial sensing intelligence with silicon nanowires for ultraselective detection in the gas phase
Wang, B., Cancilla, J. C., Torrecilla, J. S., & Haick, H. (2014) · Nano Letters · doi:10.1021/nl404335p · Cited by 236
Self-citationSilicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
Shehada, N., Cancilla, J. C., Torrecilla, J. S., Pariente, E. S., Brönstrup, G., Christiansen, S., Johnson, D. W., Leja, M., Davies, M. P. A., Liran, O., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b03127 · Cited by 227
Self-citationDynamic Nanoparticle-Based Flexible Sensors: Diagnosis of Ovarian Carcinoma from Exhaled Breath
Kahn, N., Lavie, O., Paz, M., Segev, Y., & Haick, H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b03052 · Cited by 226
Self-citationCurrent Challenges in Volatile Organic Compounds Analysis as Potential Biomarkers of Cancer
Schmidt, K., & Podmore, I. (2015) · Journal of Biomarkers · doi:10.1155/2015/981458 · Cited by 208
“Finally nanomaterialbased chemiresistors have shown the ability to distinguish not only between the breath of patients suffering from different cancer types [143], but also between early and advanced stages of lung cancer, between the types of lung cancer, and between malignant and benign pulmonary nodules [153].”
BackgroundMaterials and Wearable Devices for Autonomous Monitoring of Physiological Markers
Wu, W., & Haick, H. (2018) · Advanced Materials · doi:10.1002/adma.201705024 · Cited by 208
Self-citationAmal, H., Leja, M., Funka, K., Lasina, I., Skapars, R., Sivins, A., Ancans, G., Kikuste, I., Vanags, A., Tolmanis, I., et al. (2016) · International Journal of Cancer · doi:10.1002/ijc.29701 · Cited by 188
Self-citationDetection of cancer through exhaled breath: a systematic review
Krilaviciute, A., Heiss, J. A., Leja, M., Kupcinskas, J., Haick, H., & Brenner, H. (2015) · Oncotarget · doi:10.18632/oncotarget.5938 · Cited by 188
Self-citationElectronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Jin, H., Huynh, T.-P., & Haick, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01066 · Cited by 167
Self-citationTaking your breath away: metabolomics breathes life in to personalized medicine
Rattray, N. J. W., Hamrang, Z., Trivedi, D. K., Goodacre, R., & Fowler, S. J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.08.003 · Cited by 160
Lung cancer chemoprevention: current status and future prospects
Keith, R. L., & Miller, Y. E. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.64 · Cited by 159
Self-citationLekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105
“Recentresearchesshowthatthese chemicalcompoundsactasgoodbio-markersforthedetection ofvariouschronicdiseases[15]suchascancer(whichincludes colorectal,breastandlung)[17],[18],airwayinflammations [19],[20],helicobacterpyloriinfectionandrecentlydiabetes.”
Binson, V. A., & Subramoniam, M. (2022) · Journal of Biomimetics, Biomaterials and Biomedical Engineering · doi:10.4028/p-dab04j · Cited by 14
Metadata
- Authors
- Peled, N., Hakim, M., Bunn, P. A., Miller, Y. E., Kennedy, T. C., Mattei, J., Mitchell, J. D., Hirsch, F. R., & Haick, H.
- Venue
- Journal of Thoracic Oncology
- Publisher
- Elsevier BV
- Published
- 2012-10
- Volume
- 7
- Issue
- 10
- Pages
- 1528-1533
- ISSN
- 1556-0864 (ISSN-L)
- OpenAlex
- W1998960474
- Cited by
- 194
- References
- 30
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.