The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Haptic feedback in robot-assisted minimally invasive surgery
Open accessAbstract
PURPOSE OF REVIEW: Robot-assisted minimally invasive surgery (RMIS) holds great promise for improving the accuracy and dexterity of a surgeon and minimizing trauma to the patient. However, widespread clinical success with RMIS has been marginal. It is hypothesized that the lack of haptic (force and tactile) feedback presented to the surgeon is a limiting factor. This review explains the technical challenges of creating haptic feedback for robot-assisted surgery and provides recent results that evaluate the effectiveness of haptic feedback in mock surgical tasks. RECENT FINDINGS: Haptic feedback systems for RMIS are still under development and evaluation. Most provide only force feedback, with limited fidelity. The major challenge at this time is sensing forces applied to the patient. A few tactile feedback systems for RMIS have been created, but their practicality for clinical implementation needs to be shown. It is particularly difficult to sense and display spatially distributed tactile information. The cost-benefit ratio for haptic feedback in RMIS has not been established. SUMMARY: The designs of existing commercial RMIS systems are not conducive for force feedback, and creative solutions are needed to create compelling tactile feedback systems. Surgeons, engineers, and neuroscientists should work together to develop effective solutions for haptic feedback in RMIS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Force and Touch Feedback for Virtual Reality
Burdea, G. (1996) · Cited by 1,019
Jones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Hayward, V., Astley, O. R., Cruz‐Hernandez, M., Grant, D., & Robles‐De‐La‐Torre, G. (2004) · Sensor Review · doi:10.1108/02602280410515770 · Cited by 600
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K., Seneviratne, L. D., Murphy, D., & Dasgupta, P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588
Methods for haptic feedback in teleoperated robot‐assisted surgery
Okamura, A. M. (2004) · Industrial Robot: An International Journal · doi:10.1108/01439910410566362 · Cited by 493
Self-citationHaptic rendering: introductory concepts
Salisbury, K., Conti, F., & Barbagli, F. (2004) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2004.1274058 · Cited by 463
Basdogan, C., De Rensselaer, S., Kim, J., Muniyandi, M., Kim, H., & Srinivasan, M. A. (2004) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2004.1274062 · Cited by 357
Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis
Tholey, G., Desai, J. P., & Castellanos, A. E. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000149301.60553.1e · Cited by 330
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
The Importance of the Sense of Touch in Virtual and Real Environments
Robles-De-La-Torre, G. (2006) · IEEE Multimedia · doi:10.1109/mmul.2006.69 · Cited by 311
Howe, R. D., Peine, W. J., Kantarinis, D. A., & Son, J. S. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391770 · Cited by 296
Effect of sensory substitution on suture-manipulation forces for robotic surgical systems
Kitagawa, M., Dokko, D., Okamura, A. M., & Yuh, D. D. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.05.029 · Cited by 278
Self-citationEffects of visual force feedback on robot-assisted surgical task performance
Reiley, C. E., Akinbiyi, T., Burschka, D., Chang, D. C., Okamura, A. M., & Yuh, D. D. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.08.043 · Cited by 228
Self-citationTactile sensing technology for minimal access surgery––a review
Eltaib, M. E. H., & Hewit, J. R. (2003) · Mechatronics · doi:10.1016/s0957-4158(03)00048-5 · Cited by 221
Dargahi, J., Parameswaran, M., & Payandeh, S. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.870059 · Cited by 209
Do it yourself haptics: part I
Hayward, V., & Maclean, K. E. (2007) · IEEE Robotics & Automation Magazine · doi:10.1109/m-ra.2007.907921 · Cited by 208
A compliant tactile display for teletaction
Moy, G., Wagner, C., & Fearing, R. S. (2002) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.845247 · Cited by 180
The benefit of force feedback in surgery: Examination of blunt dissection
Wagner, C. R., Stylopoulos, N., Jackson, P. G., & Howe, R. D. (2007) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.16.3.252 · Cited by 169
A brief taxonomy of tactile illusions and demonstrations that can be done in a hardware store
Hayward, V. (2008) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.01.008 · Cited by 166
Ström, P., Hedman, L., Särnå, L., Kjellin, A., Wredmark, T., & Felländer‐Tsai, L. (2006) · Surgical Endoscopy · doi:10.1007/s00464-005-0545-3 · Cited by 156
Leven, J., Burschka, D., Kumar, R., Zhang, G., Blumenkranz, S., Dai, X., Awad, M., Hager, G. D., Marohn, M., Choti, M., et al. (2005) · Lecture notes in computer science · doi:10.1007/11566465_100 · Cited by 134
Analysis of Suture Manipulation Forces for Teleoperation with Force Feedback
Kitagawa, M., Okamura, A. M., Bethea, B. T., Gott, V. L., & Baumgartner, W. A. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_20 · Cited by 120
Self-citationForce Feedback Benefit Depends on Experience in Multiple Degree of Freedom Robotic Surgery Task
Wagner, C. R., & Howe, R. D. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.904891 · Cited by 111
A dense array stimulator to generate arbitrary spatio-temporal tactile stimuli
Killebrew, J. H., Bensmaïa, S. J., Dammann, J. F., Denchev, P. V., Hsiao, S. S., Craig, J. C., & Johnson, K. O. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.012 · Cited by 99
Artificial tactile sensing in minimally invasive surgery – a new technical approach
Schostek, S., Ho, C., Kalanovic, D., & Schurr, M. O. (2006) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700600836299 · Cited by 91
Force-Feedback Surgical Teleoperator: Controller Design and Palpation Experiments
Mahvash, M., Gwilliam, J. C., Agarwal, R., Vágvölgyi, B., Su, L.-M., Yuh, D. D., & Okamura, A. M. (2008) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptics.2008.4479994 · Cited by 79
Self-citationDo It Yourself Haptics: Part II [Tutorial]
MacLean, K. E., & Hayward, V. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/m-ra.2007.914919 · Cited by 78
Tactile Imaging System for Localizing Lung Nodules during Video Assisted Thoracoscopic Surgery
Miller, A. P., Peine, W. J., Son, J. S., & Hammoud, Z. T. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363927 · Cited by 77
Pneumatic balloon actuators for tactile feedback in robotic surgery
Culjat, M. O., King, C., Franco, M. L., Bisley, J. W., Grundfest, W. S., & Dutson, E. (2008) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439910810893617 · Cited by 74
Vibrotactile force feedback system for minimally invasive surgical procedures
Schoonmaker, R. E., & Cao, C. G. L. (2006) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2006.385233 · Cited by 70
Do Humans Sense Finger Deformation or Distributed Pressure to Detect Lumps in Soft Tissue?
Peine, W. J., & Howe, R. D. (1998) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece1998-0265 · Cited by 34
Verner, L. N., & Okamura, A. M. (2007) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2007.46 · Cited by 29
Self-citationGraphical display of tactile sensing data with application in minimally invasive surgery
Dargahi, J., Najarian, S., & Ramezanifard, R. (2007) · Canadian Journal of Electrical and Computer Engineering · doi:10.1109/cjece.2007.4413126 · Cited by 19
Cited by
A review of tactile sensing technologies with applications in biomedical engineering
Tiwana, M. I., Redmond, S. J., & Lovell, N. H. (2012) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.02.051 · Cited by 721
A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Metadata
- Authors
- Okamura, A. M.
- Venue
- Current Opinion in Urology
- Published
- 2009-01
- Volume
- 19
- Issue
- 1
- Pages
- 102-107
- ISSN
- 0963-0643 (ISSN-L)
- OpenAlex
- W2009180946
- Cited by
- 708
- References
- 33
- FWCI
- 22.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.